You are on page 1of 37

BIPV & its applications

Example CII-Green Business centre, Hyderabad


Founder, Chairman and CTO Andreas Molin
Net Zero Energy Building at CII-GBC
• CII GBC’s a Net Zero Energy Building
• 125 kWp solar PV system, with PPAM Transparium
bifacial solar PV modules

• PPAM Transparium – unique features:


Solar PV System
• Bifacial solar PV module (360 Wp & 300 Wp);
transparent & frameless

• Bifacial – backside has a power rating of at least 90%


of front side

• Energy boost – 20-30 % with an elevation of 1.5 m


above roof surface

• Reflective paint coating (high albedo)

• Solar panel with undisturbed reflection can yield


+57%
Multifunctional solar power
Bifacial solar panel PPAM Transparium

.
Transparium at Luleå Energy
Vertical transparium at CII GBC
Vertical solar

No land use
Higher hosting capacity
Fence, Noise barrier, Visual barrier

Experimental yield study of bifacial PV


modules in Nordic conditions
Elin Molina,c*, Bengt Stridhb, Andreas Molinc,d, Ewa Wäckelgårda
Smart solar generation @ peak spot price
Electricty spot price vs Generation profile
40 12 May 2016 0.9

35 0.8

0.7
30

GENERATION [KWH/KWP]
0.6
PRICE [€/MWH]

25
0.5
20
0.4
15
0.3
10
0.2

5 0.1

0 0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
TIME

Sweden Area Price Nordpoolspot Transparium vertical EW 90 Onyxium 40 S


Higher solar implementation-higher value

Related literature:
Smart city- Vision

Generation and consumption


Elevated roof – decreases cooling demand
PPAM Transparium solar shield – decreases
cooling
Sound Barrier Effect
PPAM
Transparium

~
34db
Fall protection

http://ppam.se/ppam-transparium-krocktestad/
Multifinctional Benefits
• Bifacial elevated panels will reduce chilling demand
• Reflective coating and shaded with elevated panels
• Shading windows will reduce chilling demand

• Other multifunctionality:
• Fence / parapet
• Noise barrier
• Visual barrier
Bifacial studies
ALBEDO IS IMPORTANT

• Vertical E-W
• Simulations show that the
annual specific energy yield
would be increased to to 1.47
MWh/kWp, compared 0.98
MWh/kWp.
South at 40°tilt, Nordic conditions.
• Moreover, simulations show that
the annual specific energy yield
would be increased to 1.50
MWh/kWp compared 1.01
MWh/kWp
• The annual specific yield increased
with 32 %. The BGE increased from
3 % to 26 %
• Albedo change from 0.05 to 0.80.
Albedo: Specific yield increase 48% .
Bangalore: Albedo increase
The Case at CII-GBC
CII: Demand and Solar Supply
Net-zero Building Smart or Microgrid

Active Demand Management

Supply Management

Multifunctional solar => higher building energy efficiency

No new Land-use
Trimming the supply

Vertical and
elevated solar panels
Vertical E-W panels

Transparium at CII GBC


Elevated panels in low tilt
(optimise summer demand)
Energy Balance without grid-export
Smart system
• Activation of loads-
• Cooling- pre-chilling
• UPS battery charging
• Future EV
• Solar Curtailment, if a need to limit Feed-in
• Smart Active Demand & Supply Management
• Eventually => sanctioned load of 10 kW compared to
todays 85 kW.
• Net-metering scheme Telangana
• 80% of Sanctioned load can be fed in
Thank you

andreas.molin@ppamsolkraft.se

You might also like