You are on page 1of 2

TEST PILE DRIVING DATA

Name of Project: DAGO-OK BRIDGE


Location: Lumbatan, Lanao del Sur Pile Type: H Beam
Type of Equipment: SD 30 Ground Elevation: 806.090
Location of Test Pile: Abutment A Size of Pile: Steel H-Pile (14 x 117)
Date Driven 11/12/2019 Length of Pile: 18
Allowable Bearing Capacity 750 kN
Pall = Allowable Pile Bearing capacity
(KN)
eh = Hammer Efficiency 0.70
Eh = Hammer Energy Rating (Kn-m) 74.18 [167eh EH] [Wr + 0.16 Wp]
Wp = Weight of Pile & Other Driven Pall =
30.72 S + 2..54 Wr + Wp
Weights (KN)
Wr = Weight of RAM 33.72
S = Average Penetration per Blow for the
2.69
last 150mm of Driving (mm)

TOTAL AVERAGE ALLOWABLE


TIP OF PILE DEPTH OF PILE HEIGHT OF NO. OF BLOWS/
PENETRATION PENETRATION BEARING REMARKS
ELEVATION ON GROUND (m) FALL (m) PENETRATION
(m) (mm) CAPACITY (KN)
806.09 0.00 Bottom of Footing
807.09 1.00 Failure
808.09 2.00 Failure
809.09 3.00 1.50 1.00 5.00 200.00 25.67 Failure
810.09 4.00 1.50 1.00 6.00 166.67 30.73 Failure
811.09 5.00 1.50 1.00 20.00 50.00 98.96 Failure
812.09 6.00 2.00 1.00 19.00 52.63 94.24 Failure
813.09 7.00 2.00 1.00 17.00 58.82 84.73 Failure
814.09 8.00 2.00 1.00 25.00 40.00 122.22 Failure
815.09 9.00 2.00 1.00 39.00 25.64 184.49 Failure
816.09 10.00 2.00 1.00 29.00 34.48 140.43 Failure
817.09 11.00 2.00 1.00 38.00 26.32 180.18 Failure
818.09 12.00 2.00 1.00 52.00 19.23 238.81 Failure
819.09 13.00 2.00 1.00 41.00 24.39 193.06 Failure
820.09 14.00 2.00 0.30 52.00 5.77 625.70 Failure
821.09 15.00 2.00 1.00 32.00 31.25 153.87 Failure
822.09 16.00 2.00 1.00 12.00 83.33 60.54 Failure
823.09 17.00 2.00 1.00 52.00 19.23 238.81 Failure
824.09 18.00 2.20 1.00 73.00 13.70 320.17 Failure
825.09 19.00 2.20 1.00 55.00 18.18 250.90 Failure
826.09 20.00 2.20 1.00 110.00 9.09 447.01 Failure
827.09 21.00 2.20 1.00 135.00 7.41 522.66 Failure
828.09 22.00 2.20 1.00 129.00 7.75 505.16 Failure
828.69 22.60 2.20 0.60 223.00 2.69 993.98 Refusal

Test Pile Length : 22.60 m.


Recommended Pile Length : 23.00 m.

Prepared by: Evaluation by: Witnessed by:

LANI ROHANI M. KOUZBARY FAHAD A. ABBAS RAZUL B. DARANGINA


Contractor, Kouzbary Builders Resident Engineer, DPWH PDD-Representative, DPWH

Checked and Reviewed by: Submitted by: Data Verified and Checked:

MIKUNUG R. MACABANTOG VIRGIE G. NAYVE SABENIANO D. CALIAO, JR.


Project Engineer, DPWH Chief, Construction Division Chief, Planning & Design Division

Approved by:

ZENAIDA T. TAN
Regional Director
DPWH Region X
TEST PILE DRIVING DATA

Name of Project: DAGO-OK BRIDGE


Location: Lumbatan, Lanao del Sur Pile Type: H Beam
Type of Equipment: SD 30 Ground Elevation: 806.090
Location of Test Pile: Abutment B Size of Pile: Steel H-Pile (14 x 117)
Date Driven 10/26/2019 Length of Pile: 18
Allowable Bearing Capacity 750 kN
Pall = Allowable Pile Bearing capacity
(KN)
eh = Hammer Efficiency 0.70
Eh = Hammer Energy Rating (Kn-m) 74.18 [167eh EH] [Wr + 0.16 Wp]
Wp = Weight of Pile & Other Driven Pall =
30.72 S + 2..54 Wr + Wp
Weights (KN)
Wr = Weight of RAM 33.72
S = Average Penetration per Blow for the
2.47
last 150mm of Driving (mm)

TOTAL AVERAGE ALLOWABLE


TIP OF PILE DEPTH OF PILE HEIGHT OF NO. OF BLOWS/
PENETRATION PENETRATION BEARING REMARKS
ELEVATION ON GROUND (m) FALL (m) PENETRATION
(m) (mm) CAPACITY (KN)
806.09 0.00 Bottom of Footing
807.09 1.00 Failure
808.09 2.00 1.50 1.00 1.00 1,000.00 5.19 Failure
809.09 3.00 1.50 1.00 3.00 333.33 15.48 Failure
810.09 4.00 1.50 1.00 2.00 500.00 10.35 Failure
811.09 5.00 1.50 1.00 7.00 142.86 35.76 Failure
812.09 6.00 2.00 1.00 15.00 66.67 75.12 Failure
813.09 7.00 2.00 1.00 22.00 45.45 108.33 Failure
814.09 8.00 2.00 1.00 28.00 35.71 135.91 Failure
815.09 9.00 2.00 1.00 15.00 66.67 75.12 Failure
816.09 10.00 2.00 1.00 39.00 25.64 184.49 Failure
817.09 11.00 2.00 1.00 55.00 18.18 250.90 Failure
818.09 12.00 2.00 1.00 68.00 14.71 301.47 Failure
819.09 13.00 2.00 1.00 60.00 16.67 270.69 Failure
820.09 14.00 2.00 0.30 55.00 5.45 650.33 Failure
821.09 15.00 2.00 1.00 68.00 14.71 301.47 Failure
822.09 16.00 2.00 1.00 35.00 28.57 167.11 Failure
823.09 17.00 2.00 1.00 51.00 19.61 234.75 Failure
824.09 18.00 2.20 1.00 81.00 12.35 349.27 Failure
825.09 19.00 2.20 1.00 65.00 15.38 290.05 Failure
826.09 20.00 2.20 1.00 139.00 7.19 534.10 Failure
827.09 21.00 2.20 1.00 290.00 3.45 868.21 Pass
828.09 21.23 2.20 0.23 93.00 2.47 1,037.10 Pass

Test Pile Length : 21.23 m.


Recommended Pile Length : 22.00 m.

Prepared by: Evaluation by: Witnessed by:

LANI ROHANI M. KOUZBARY FAHAD A. ABBAS RAZUL B. DARANGINA


Contractor, Kouzbary Builders Resident Engineer, DPWH PDD-Representative, DPWH

Checked and Reviewed by: Submitted by: Data Verified and Checked:

MIKUNUG R. MACABANTOG VIRGIE G. NAYVE SABENIANO D. CALIAO, JR.


Project Engineer, DPWH Chief, Construction Division Chief, Planning & Design Division

Approved by:

ZENAIDA T. TAN
Regional Director
DPWH Region X

You might also like