You are on page 1of 1

Supplemental material for the manuscript

“Stray Loss Model for Induction Motors with Using Equivalent Circuit
Parameters”
Appendix-A:
Rs Lls RR LR Lm RC
Motor (mΩ) (mH) (mΩ) (mH) (mH) (Ω)
M1 37.12 0.36 23.40 0.48 17.56 180.49
M2 8.65 0.17 10.76 0.32 6.28 137.41
M3 6.01 0.13 8.82 0.27 10.29 122.81
M4 21.74 0.26 29.61 0.59 12.94 177.40
M5 9.87 0.17 18.34 0.39 9.06 118.18
M6 6.71 0.11 13.57 0.30 6.55 97.63
M7 4.45 0.07 6.30 0.23 4.64 63.57
M8 2.33 0.09 4.20 0.42 3.14 51.78
M9 19.90 0.34 27.52 0.57 12.59 267.92
M10 7.83 0.17 18.16 0.36 6.66 85.40
M11 6.60 0.11 10.86 0.29 5.12 80.09
M12 2.58 0.09 6.81 0.13 3.71 53.38
M13 2.33 0.09 4.20 0.42 3.14 51.78
M14 19.99 0.34 27.82 0.57 10.99 126.92
M15 16.19 0.31 14.96 0.55 9.07 131.60
M16 8.97 0.24 11.21 0.35 7.66 98.37
M17 6.51 0.17 9.95 0.24 3.08 82.00
M18 7.36 0.21 12.88 0.40 7.87 53.25

Appendix-B:
Measurement data of various losses in the 18 motors:

Stray No-load Test Blocked-rotor test


Motor
loss (W) V (V) I (A) P (W) V (V) I (A) P (W)
M1 556 400 42.3 1273 61.94 130 3191
M2 1089 400 66.7 1641 56.7 220 5720
M3 1247 400 85.9 2266 56.2 275 7512
M4 450 400 46.1 1110 69.7 132 3990
M5 735 400 75.1 1590 69 200 6410
M6 940 400 103 1940 64.9 282 8540
M7 1463 400 148 3050 65 435 13580
M8 2289 400 224 4770 74.1 660 19420
M9 453 400 58.7 1406 68.9 160 4760
M10 708 400 100 2070 63.6 240 7088
M11 1553 400 129 2608 64.3 355 10894
M12 2406 400 199 3843 71.8 560 16620
M13 2816 400 224 4770 74.1 660 19420
M14 231 400 68.4 1231 73.1 145 4270
M15 478 400 76 1305 76.7 170 4764
M16 1014 400 100 1733 79.4 245 6218
M17 1197 400 117 2078 80.1 295 7404
M18 1084 400 176 2963 73.94 380 8960

You might also like