MAGDOS LA / LD
Operating instructions
Table of Contents
1 Notes for the Reader...........................................................4 10 Control...............................................................................25
1.1 General non-discrimination....................................................... 4 10.1 Operator controls of the control unit.......................................25
1.2 Explanation of the signal words................................................. 4 10.2 Explanation of the menu icons...............................................25
1.3 Explanation of the warning signs.............................................. 4
1.4 Identification of warnings.......................................................... 4 11 Operation...........................................................................27
1.5 Instruction for action identification............................................ 5 11.1 Commissioning the dosing pump..........................................27
11.2 Operating modes..................................................................28
2 Safety..................................................................................6 11.3 External On / Off via Release input.........................................32
2.1 General warnings...................................................................... 6 11.4 Decommissioning the dosing pump.......................................32
2.2 Hazards due to non-compliance with the safety instructions...... 7 11.5 Shutting down in an emergency............................................32
2.3 Working in a safety-conscious manner...................................... 7 11.6 Storage................................................................................32
2.4 Personal protective equipment.................................................. 7 11.7 Transportation......................................................................32
2.5 Personnel qualification.............................................................. 7 11.8 Disposal of old equipment.....................................................32
8 Hydraulic installations......................................................17
8.1 Design of the system...............................................................17
8.2 System piping.........................................................................17
8.3 Aligning the dosing head.........................................................18
8.4 Hydraulic connections.............................................................18
8.5 Connecting a leakage drain.....................................................19
8.6 Connecting the dosing head venting facility.............................19
8.7 Hydraulic accessories.............................................................20
9 Electrical installation........................................................22
9.1 Principles...............................................................................22
9.2 Description of connection sockets...........................................23
Description of danger.
Refers to a danger which, if ignored, may lead to Consequences if ignored.
NOTE risk to the machine and its function.
ð
The arrow signals a safety precaution to be taken to eliminate
the danger.
Table 1: Explanation of the signal words
è
Separate step with no follow-up action.
1. First step in a series of steps.
2. Second step in a series of steps.
4 Result of the above action.
ü
Action completed, aim achieved.
2 Safety
2.1 General warnings
WARNING
The following warnings are intended to help you to eliminate the dangers
that can arise while handling the dosing pump. Risk prevention measures Caustic burns or other burns through dosing media!
always apply regardless of any specific action.
While working on the dosing head, valves and connections, you may
Safety instructions warning against risks arising from specific activities come into contact with dosing media.
or situations can be found in the respective sub-chapters.
ð
Use sufficient personal protective equipment.
ð
Rinse the dosing pump with a liquid (e.g. water) which does not
DANGER pose any risk. Ensure that the liquid is compatible with the dosing
medium.
Mortal danger from electric shock! ð
Release pressure in hydraulic parts.
Wrongly connected or located cables or damaged ones can injure you. ð
Never look into open ends of plugged pipelines and valves.
ð
Connect the device only to a SCHUKO socket outlet protected by a
ground fault circuit interrupter (GFCI).
ð
Replace damaged cables without delay.
WARNING
ð
Do not use extension cables.
Danger of automatic start up!
ð
Do not bury cables.
After connecting the mains supply, residual dosing media in the
ð
Secure cables to avoid being damaged by other equipment.
dosing head can spray out.
ð
Before connecting the mains supply, connect the dosing lines.
DANGER ð
Check that all the screw connections have been tightened
correctly and are leak-proof.
Danger to life through explosions!
The use of dosing pumps without ATEX certification in a potentially
WARNING
explosive atmospheres can result in potentially-fatal explosions.
ð
Never use the dosing pump in potentially explosive areas.
Danger from electromagnetic radiation!
Solenoid diaphragm dosing pumps In operation, solenoid diaphragm
WARNING dosing pumps emit a stray magnetic field. If you do not keep far
enough away, the function of a pacemaker can be negatively affected.
Protective goggles
2.3 Working in a safety-conscious manner Wear the following personal protective equipment when performing the
following tasks:
Besides the safety instructions specified in this operating manual, further
n Commissioning
safety rules apply and must be followed:
n Working on the dosing pump while running
n Accident prevention regulations n Shutdown
n Safety and operating provisions n Maintenance work
n Safety provisions for handling dangerous substances (mostly the n Disposal
safety data sheets to dosing media)
n Environmental protection provisions 2.5 Personnel qualification
n Applicable standards and legislation Any personnel who work on the dosing pump must have appropriate
special knowledge and skills.
Anybody who works on the dosing pump must meet the conditions below:
n Attendance at all the training courses offered by the owner,
n personal suitability for the respective activity,
n sufficient qualification for the respective activity,
n Training in handling of the dosing pump,
n knowledge of safety equipment and the way this equipment functions,
n knowledge of this operating manual, particularly of safety instructions
and sections relevant for the activity,
n knowledge of fundamental regulations regarding health and safety
and accident prevention.
All persons must generally have the following minimum qualification:
n Training as specialists to carry out work on the dosing pump
unsupervised,
n sufficient training that they can work on the dosing pump under the
supervision and guidance of a trained specialist.
Qualification Activities
3 Intended use
3.1 Notes on product warranty n The materials of the dosing pump and hydraulic parts of the system
must be suitable for the dosing medium that is used. In this connec-
tion, note that the resistance of these components can change in
Any non-designated use of the product can compromise its function or
dependence on the temperature of the media and the operating
intended protection. This leads to invalidation of any warranty claims!
pressure.
Please note that liability is on the side of the user in the following cases:
Information on the suitability of materials combined with
n The dosing pump is operated in a manner which is not consistent with
these operating instructions, particularly safety instructions, handling
i different dosing media can be found in the Compatibility Chart
of Lutz-Jesco GmbH.
instructions and the section "Intended Use".
The information in this resistance list is based on information
n If people operate the product who are not adequately qualified to carry
from the material manufacturers and on expertise obtained by
out their respective activities.
Lutz-Jesco from handling the materials.
n No original spare parts or accessories of Lutz-Jesco GmbH are used. As the durability of the materials depends on many factors,
n Unauthorised changes are made to the device by the user. this list only constitutes initial guidance on selecting material.
n The user uses different dosing media than those indicated in the In all cases, test the equipment with the chemicals you use
order. under operating conditions.
n The user does not use dosing media under the conditions agreed with
the manufacturer such as modified concentration, density, tempera- n The dosing pump is not intended for outdoor use unless appropriate
ture, contamination, etc. protective measures have been taken.
n Avoid leaks of liquids and dust into the casing and avoid direct
3.2 Intended purpose exposure to sunlight.
n You must never operate dosing pumps in a potentially explosive
The dosing pump MAGDOS LA / LD is intended for the following purpose: atmosphere if they do not have corresponding nameplates or an
the conveying and dosing of liquids. appropriate EC Declaration of Conformity for potentially explosive
atmospheres.
3.3 Device revision
3.5 Prohibited dosing media
This operating manual applies to the following devices:
The dosing pump must not be used for these media and substances:
Device Month / year of Firmware n Gaseous media,
manufacture n radioactive media,
MAGDOS LA 11/2016 onwards From 01:59 n solid substances,
n combustible media,
MAGDOS LD 11/2016 onwards From 01:59 n all other media that are not suitable for delivery using this dosing
Table 5: Device revision pump.
Foreseeable misuse is assigned to the individual stages of the product n Delivery of dosing media for which the system is not designed
lifetime: n Delivery of particulate or contaminated dosing media
n Inadequate protective clothing or none at all
3.6.1 Incorrect assembly
3.6.6 Incorrect maintenance
n Unstable or unsuitable bracket
n Dosing pump bolted wrongly or loosely n Carrying out maintenance during ongoing operation
n Carrying out work that is not described in the operating manual
3.6.2 Incorrect hydraulic installation n No adequate or regular inspection of correct functioning
n Suction and pressure lines dimensioned incorrectly n No replacement of damaged parts or cables with inadequate
n Unsuitable connection of the pipes due to wrong material or insulation
unsuitable connections. n No securing against reactivation during maintenance work
n Suction and pressure lines mixed-up n Using cleaning materials that can cause reactions with the dosing
n Damage to threads due to them being tightened too much media
n Bending of pipelines n Inadequate cleaning of the system
n No free return flow of the pressure relief valve n Unsuitable purging medium
n Excessive demand due to the pressure differences between the n Unsuitable cleaning materials
suction and pressure valves n Detergents left in system parts
n Through-suction at installation without back-pressure valves n Using unsuitable cleaning equipment
n Damage due to undamped acceleration mass forces n Using the wrong spares or lubricants
n Exceeding the admissible pressure on the suction and discharge sides n Contaminating the dosing medium with lubricant
n Using damaged parts n Installing spare parts without following the instructions in the
operating manual
3.6.3 Incorrect electrical installation n Blocking venting orifices
n Connecting the mains voltage without a protective earth n Pulling off sections of the plant
n Unsecured mains or one that does not conform to standards n Contamination at installation without a dirt trap
n Not possible to immediately or easily disconnect the power supply n Mixing up the valves
n Wrong connecting cables for mains voltage n Mixing up the sensor lines
n Dosing pump accessories connected to wrong sockets n Not reconnecting all the lines
n Diaphragm monitoring not connected or defective n Damaging or not installing all the seals
n Personnel was not informed before the start-up n Dismantling lines while the dosing pump is running
n System was recommissioned after maintenance without all the n Device not disconnected from the power supply
protective equipment and fixtures, etc. being reconnected. n Using the wrong dismantling tools
n Inadequate protective clothing or none at all n Inadequate protective clothing or none at all
10 Intended use
BA-10010-02-V01 © Lutz-Jesco GmbH 2017
Foreseeable misuse
Solenoid-diaphragm dosing pump MAGDOS LA / LD Operating instructions
4 Product description
4.1 Properties 4.3 Structure of the dosing pump
The MAGDOS is a solenoid diaphragm dosing pump that is used when 4.3.1 General Overview
precise dosing results are required.
No. Description
4.2 Scope of delivery
1 Dosing head
Please compare the delivery note with the scope of delivery. The
following items are part of the scope of delivery: 2 Drive unit
No. Description
7 8 9 10
12 Product description
BA-10010-02-V01 © Lutz-Jesco GmbH 2017
Function description
Solenoid-diaphragm dosing pump MAGDOS LA / LD Operating instructions
5 Technical data
Please note that some of this data only represents guide values. The actual capacity of a dosing pump depends on various factors. For approximate
values of the delivery capacity at different pressures, refer to chapter 15 „Delivery characteristic curves“ on page 38.
MAGDOS LA / LD Size
Information Value
05 1 2 4 6 10 15
MAGDOS LA / LD Size
Information Value
05 – 15
* Use of the dosing pump at ambient temperatures below 5 °C must be checked individually. In such cases, please contact the manufacturer.
** With a viscosity of ~300 mPa∙s and above, you must use spring-loaded valves.
*** If the viscosity is above 1000 mPa∙s, this must be checked individually and the stroke frequency must be between 50 and 100 strokes/min.
MAGDOS LA / LD Size
Information Value
05 1 2 4 6 10 15
Max. current consumption during dosing stroke A 2.0 3.0 3.7 3.8 4.1 3.6
Table 13: Electrical specifications
MAGDOS LA / LD Size
Information Value
05 1 2 4 6 10 15
Insulation class F
14 Technical data
BA-10010-02-V01 © Lutz-Jesco GmbH 2017
Approved media temperature
Solenoid-diaphragm dosing pump MAGDOS LA / LD Operating instructions
6 Dimensions
Fig. 5: Dimensioned drawing of MAGDOS
LA / LD with dosing head made of PVC, PP or PVDF (all dimensions in mm)
Connection Material Scale Nominal width L
4/6 mm DN4 31
6/9 mm DN6 34
6/12 mm DN6 15
Fig. 6: Dimensioned drawing of MAGDOS LA / LD with dosing head made of stainless steel 1.4571 (all dimensions in mm)
CAUTION
8 Hydraulic installations
In this chapter, you will find information about the hydraulic parts of a 8.1 Design of the system
system that you should install or that can install additionally. In many
cases, you must install hydraulic accessories to be able to use all the n The dosing pump s technical data must be taken into account and the
functions that the dosing pump offers, to guarantee functional safety or to plant s layout must be set up appropriately (e.g. pressure loss when
achieve a high level of dosing precision. rating the lines with regard to their nominal diameter and length).
n The entire system and its integrated dosing pump must be designed
WARNING in such a way that an escaping dosing medium (due to the failure of
wearing parts such as the diaphragm, or burst hoses) does not lead to
permanent damage to system parts or the premises.
Caustic burns or other burns through dosing media! n The leakage opening of the dosing head must be visible so that you
A diaphragm rupture, blocked pressure lines or the use of material not can detect a diaphragm rupture. It must be possible for the outflow
suitable for the dosing medium can result in the discharge of dosing from the leakage drain to be on a free downwards gradient.
medium. Depending on the type and hazardousness of the dosing n If you use hazardous dosing media, the installation must be designed
medium, this can result in injury. such that no disproportionately high consequential damages arise
ð
Wear the recommended personal protective equipment. due to dosing media escaping.
n To avoid dosing errors after the end of the process, the dosing pump
ð
Make sure that the materials you are using are suitable for the
must be locked hydraulically.
dosing medium.
n To allow you to easily inspect the pressure conditions in the system,
ð
Make sure that the lubricants, adhesives, sealants, etc. that you you should provide connections for pressure gauges close to the
use are suitable for the dosing medium. suction and pressure valves.
ð
Install a leakage drain.
ð
Install pressure relief valves. 8.2 System piping
n The system piping must not exert any force on the connections and
valves of the dosing pump.
CAUTION
n This means that steel piping should be connected to the dosing pump
by means of flexible pipe sections.
Danger of personal injury and material damage! n The nominal diameters of the pipework and the installed fittings
High peak pressures can lead to piping vibrating and cause them to should be rated the same as or greater than the nominal diameters of
snap. This can result in injury from piping or escaping dosing media. the dosing pump's suction and pressure valves.
n The suction line should be kept as short as possible.
ð
Install pulsation dampeners.
n You should avoid intertwined hoses.
n Avoid loops, since air bubbles can collect.
NOTE
NOTE
Locking of threads
Stainless steel and plastic parts (particularly those made of PVC) that
are bolted together in a detachable connection (e.g. the dosing head
and the valves) can lock. This makes them difficult to release.
ð
Before bolting, grease the corresponding parts with a lubricant
(e.g. PTFE spray). Ensure that the lubricant is compatible with the
dosing medium.
8.3 Aligning the dosing head 2. Place a gasket that is suitable for the dosing medium between the
connection (5) and the valve.
3. Screw the connecting piece e to the dosing pump's valve using the
a (2).
4. Thread the union nut (3) and the clamping ring (4) onto the hose.
5. Plug the hose all the way in to the grommet of connection piece.
6. Push the clamping ring onto the grommet of connection piece and
screw it to the union nut.
b
7. Carry out the same procedure with the connection to the dosing
pump's other valve.
ü
Hose clip connected.
c
8.4.1.2 Size 6/12
8.4.1 Connecting hose clips Size 6/12 hose clips only have a union nut. It clamps the hose onto the
grommet of the connection piece and at the same time fastens on the
Choose the hose connection according to the condition of the hose dosing pump's valve.
(material, inner diameter, wall thickness) in order to ensure maximum
pressure resistance. Perform the following working steps:
8.4.1.1 Size 4/6 and 6/9 1. Cut the hose (1) to the appropriate length neatly and at an exact right
angle.
4/6 6/9 2. Place a gasket that is suitable for the dosing medium between the
a a connection (4) and the valve.
3. Push the union nut (2) and the cutting ring (3) over the hose.
b 4. Press the end of the hose onto the grommet of connection piece. You
can do this more easily by moistening the end of the hose on the
b inside or applying some lubricant to the grommet in the cone area.
c You should push at least two thirds of the hose onto the grommet of
c the connection piece.
d 5. Push the cutting ring over the hose into the cone area on the
d grommet of connection piece.
6. Screw the union nut onto the valve of the dosing pump.
e e
ü
Hose clip connected.
Fig. 10: Hose clips 4/6 and 6/9 (internal and external diameters in mm)
1. Cut the hose (1) to the appropriate length neatly and at an exact right
angle.
18 Hydraulic installations
BA-10010-02-V01 © Lutz-Jesco GmbH 2017
Aligning the dosing head
Solenoid-diaphragm dosing pump MAGDOS LA / LD Operating instructions
ü
Glue-in connection made. Fig. 14: Openings of the leakage drain
Perform the following working steps: 8.6 Connecting the dosing head venting facility
1. Cut the tube to length. MAGDOS LA / LD dosing heads have an integrated dosing head venting
2. Cut the thread (2) onto the end of the tube. facility (except for dosing heads made of stainless steel).
3. Push the union nut (1) onto the tube. For the procedure when venting, refer to chapter 11.1.1 „Venting the
4. Seal the thread. When choosing your sealing material, take into dosing pump“ on page 27.
account its resistance to material, temperature and pressure.
5. Screw the union nut onto the valve of the dosing pump. Use a gasket
that is suitable for the dosing medium.
ü
Cemented connection made.
Perform the following working steps: At an appropriate pressure, a pressure relief valve opens a bypass line
and protects the system in this way from damage caused by over-pres-
1. Connect a 4/6 hose to the dosing head venting facility. sure.
2. Route the other end of the hose into the dosing tank or a collecting
Notes on assembly:
tank.
n The line for returning dosing medium from the pressure relief valve
ü
Dosing head venting facility connected. must be routed to the dosing tank or to a collecting pan.
n The pressure in the dosing tank must not be too high so that it is
possible to accommodate the returned dosing medium.
8.7 Hydraulic accessories n As an alternative, the system can return dosing medium into the
suction line in front of the dosing pump. In this case, there must not be
The following chapter is intended to give you an overview of installation a non-return valve or a foot valve in the suction line.
options. n You should install the pressure relief valve as close as possible to the
Please note that these operating instructions are no substitute for the dosing head.
instructions supplied with the accessories in each case. The correspond-
ing documentation supplied with the product applies to safety informa- 8.7.4 Back-pressure valve
tion and provides exact instructions on assembly.
Back-pressure control valves are necessary if:
8.7.1 Injection nozzle n there are considerably fluctuating system pressures,
n the pressure on the suction side is higher than on the discharge side
If the pressure line enters a main line, it is advisable to install an injection or if you intend to carry out dosing into depressurized lines.
nozzle.
In cases like this, if you do not use a back-pressure valve, imprecise
Injection nozzles have three main functions: dosing results will occur or overloading will result. The back-pressure
valve solves these problems by generating a defined, constant backpres-
n Dosing the medium into a main line,
sure.
n Preventing flowback into the pressure line through a non-return valve.
In some circumstances, a back-pressure valve is unnecessary if you use
Notes on assembly: a hose injection nozzle and if the backpressure that it generates is
n Double-ball injection nozzles must be installed into the main line adequate.
vertically from the bottom. You can install hose and spring-loaded
injection nozzles any way you like. 8.7.5 Pulsation dampener
n With dosing media that tend to crystallize, it is advisable to carry out
installation into the main line from the bottom. This prevents air Pulsation dampeners have the following functions:
bubbles from being trapped. n Damping pulsating delivery flows for processes that require
n Many dosing media tend to contaminate the injection nozzles, which low-pulsation dosing,
can lead to blockages. In cases like this, it is advisable to install an n Reducing the throughflow resistance with long pipelines.
injection nozzle that is easy to dismantle and block off.
When installed on the suction side:
8.7.2 Contact-type water meter n Damping of acceleration mass forces and with this reduction of wear
on the dosing pump.
The contact-type water meter measures the throughflow in a pipe and
n Preventing cavitation (pull-off of the liquid column) due to too high
sends a pulse to the dosing pump, which then starts dosing. This means
acceleration.
that ideal proportional dosing is also possible with large throughflow
fluctuations. However, pulsation dampeners also have important safety functions,
since they prevent pressure peaks from arising that lead to piping
The contact water meter is connected to connection port 2 (see chapter vibrating and cause them to snap.
9.2.2 „Connection socket 3“ on page 24).
This problem can occur:
8.7.3 Pressure-relief valve n with the high amplitudes of the vibrations,
n when using long pipes (the severity of the pulsation increases with the
Pressure relief valves have an important safety function for protecting the length of the pipe),
dosing pump and the associated pipes and fittings. The dosing pump can
n when using rigid piping instead of elastic hoses.
generate a pressure that is many times the rated one. A blocked pressure
line can lead to dosing medium escaping. Notes on assembly:
An improperly high pressure can occur if: n You should carry out assembly in the direct vicinity of the location
where you want to damp the pressure peaks (directly in front of the
n the shut-off valves are closed even though the dosing pump is
suction valve or directly behind the pressure valve).
running,
n Pulsation dampeners should be installed with throttle valves or
n pipes block.
back-pressure valves installed directly behind them. By setting the
valves appropriately, you can further-optimise damping of the
20 Hydraulic installations
BA-10010-02-V01 © Lutz-Jesco GmbH 2017
Hydraulic accessories
Solenoid-diaphragm dosing pump MAGDOS LA / LD Operating instructions
9 Electrical installation
NOTE
Fig. 16: Conductive rubber hoses in the connections 1 and 3 of the MAGDOS LA/LD
9.1 Principles
n The dosing pump is fitted with a 115 V AC or 230 V AC (50 / 60 Hz)
power supply unit.
n The electrical connection comply with local regulations.
n The dosing pump must be plugged into a grounded power outlet.
n To avoid dosing errors at the end of the process, the dosing pump
must be locked electrically.
22 Electrical installation
BA-10010-02-V01 © Lutz-Jesco GmbH 2017
Principles
Solenoid-diaphragm dosing pump MAGDOS LA / LD Operating instructions
Not all versions of the dosing pump provide all the features described
here. Every section heading includes the versions which apply to the
section.
Remove the conductive rubber band before inserting the cable in the
connection socket.
After the cable has been removed, the conductive rubber band must be
reinserted in the connection socket. Insert it between pins 1+2 and 3+4
as shown in Fig. 18.
Connection socket 2
Analogue or pulse signal input 2 n Working resistance: 200 Ohm (because of the electronic fuse), not
potential-free
Level signal input 3
Pin M12x1 Assignments Connection Cable colour
(A-coded)
Table 15: Inputs of the control unit
1 - - Brown BN
2 - - White WH
9.2.1.3 Pulse input (only LD) Removing the conductive rubber band
n Pulse length min. 4 ms Remove the conductive rubber band before inserting the cable in the
connection socket.
Pin M12x1 Assignments Connection Cable colour
(A-coded) After the cable has been removed, the conductive rubber band must be
reinserted in the connection socket. Insert it between pins 1+2 and 3+4
1 Pulses 1 Brown BN as shown in Fig. 19.
4 - - - Black BK
Table 18: Connection port 2 - pulse input
* Applies to cable colours of cables from Lutz-Jesco GmbH. No liability is
accepted for cables from other manufacturers.
Level input
4 - - - Black BK
Table 19: Connection socket 3
24 Electrical installation
BA-10010-02-V01 © Lutz-Jesco GmbH 2017
Description of connection sockets
Solenoid-diaphragm dosing pump MAGDOS LA / LD Operating instructions
10 Control
Symbol Meaning
Manual mode
a
Analogue input (only LA)
Symbol Meaning
Contact open
Contact closed
Table 23: Explanation of the menu symbols – Release input
Symbol Meaning You can set any password you like from 0001 to 9999.
1. Press + and - simultaneously.
Dosing tank full
4 The dosing pump displays the password protection menu.
Dosing tank at minimum (alert)
2. Use the+ and - keys to set a value from 0 to 9 for the first digit of the
code and then press →.
3. Proceed as described under point 2 for the other digits.
4. Choose the last point and press +.
5. Press OK.
4 The dosing pump now displays the corresponding symbol:
0%
ü
Password protection activated.
Once you press any key, you must enter the password. If you enter the
code correctly, you have 120 seconds in which to operate the dosing
pump. When the 120 seconds have elapsed, you must re-enter the code,
even if you are in the middle of making another entry (this does not
include settings in the menus).
4 3 2 1
OK - +
Fig. 23: Entering the Release code
1. Use the+ and - keys to set a value from 0 to 9 for the first digit of the
code and then press →.
2. Proceed as described under point 1 for the other digits.
3. After entering all the digits, press OK.
4 If your input is correct, the dosing pump displays the start screen.
If you have forgotten the code, please contact Lutz-Jesco
i GmbH.
ü
Enter the code.
ü
Password protection deactivated.
26 Control
BA-10010-02-V01 © Lutz-Jesco GmbH 2017
Explanation of the menu icons
Solenoid-diaphragm dosing pump MAGDOS LA / LD Operating instructions
11 Operation
ü
The dosing pump is commissioned.
CAUTION
11.1.1 Venting the dosing pump
Danger of automatic start up! Plastic dosing heads are fitted with a vent screw. Gas bubbles can be
The dosing pump does not have an ON/OFF switch and may start to removed from the dosing head using vent screws, in order to improve the
pump as soon as it is connected to the mains supply. This means that performance of the pump. Whether venting is helpful depends on the
dosing medium can escape. Depending on the type and hazardous- dosing medium and the size of the pump.
ness of the dosing medium, this can result in injury.
ð
Stop the dosing pump before disconnecting it from the mains CAUTION
supply.
ð
Ensure that the dosing pump has been installed correctly before Danger of personal injury and material damage!
connecting it to the mains supply.
Dosing medium can escape if you loosen connections on the dosing
head (e.g. for venting) during operation.
ð
Use sufficient personal protective equipment.
11.1 Commissioning the dosing pump
ð
Follow the safety data sheet of the dosing medium.
Precondition for action: ð
Clean the dosing pump if dosing medium escapes.
ü
The dosing pump was fitted and installed in accordance with the sec- ð
Dispose of the dosing medium correctly.
tions “Fitting the dosing pump”, “Hydraulic installation” and
“Electrical installation”.
ü
All the mechanical fastenings have been inspected to ensure
adequate load-bearing capacity.
ü
The dosing head screws have been tightened with the correct torque.
ü
All the hydraulic sections have been inspected to ensure they are
adequately leak-proof and that the through flow direction is correct.
4. Open the vent screw by one complete turn (looking onto the dosing 11.2.2 External operation
head, anti-clockwise).
5. Press Start. In External mode, the frequency and number of strokes issued by the
4 The dosing pump starts delivery at the highest stroke frequency. MAGDOS LD dosing pump is controlled in dependence on the pulse
frequency and number of pulses applied at the pulse input (see section
6. Press Stop, as soon as there is a continuous throughflow from the
9.2.1.3 „Pulse input (only LD)“ on page 24).
dosing head venting facility with no air bubbles.
4 The dosing pump stops delivery. The MAGDOS LA is controlled via an analogue signal.
7. Close the vent screw.
11.2.2.1 Selecting the operating mode
ü
The dosing pump is vented.
è
Press Ext to select the operating mode.
If you are using strongly effervescent dosing media, allow 4 The dosing pump shows the start display of the operating mode
i them to flow out continuously. Open the vent screw such that External.
about one drop per 1 – 3 strokes escapes, then close the
discharge. 100%
28 Operation
BA-10010-02-V01 © Lutz-Jesco GmbH 2017
Operating modes
Solenoid-diaphragm dosing pump MAGDOS LA / LD Operating instructions
Int - + Start If you have no Internet connection, you can also perform the calculation
yourself.
Fig. 28: Number of pulse signals required (here: 2)
The following parameters are required for this:
Examples for transmission / reduction
n required dosing quantity in ml/pulse
n delivery capacity of the dosing pump in ml/stroke
Number of pulses Setting Dosing strokes
The delivery capacity of the dosing pump can be taken from in the
4 25% 1 technical data and the delivery characteristic curves (see “delivery
capacity data” on page 13 and “delivery characteristic curves” on page
2 50% 1 46). Intermediate values can be interpolated.
The dosing pump MAGDOS LD has a defined stroke volume per dosing
stroke. If a certain dosing quantity is required per pulse, the correspond-
ing transmission factor can be calculated for the external operating
mode.
If you have no Internet connection, you can also perform the calculation
yourself.
You can use the following diagram to determine the necessary size of the
dosing pump depending on the intended dosing quantity and the existing
or selected pulse sequence of the contact-type water meter. Comparison
with the technical data of the dosing pump with regards to the operating
pressure is also necessary (see “Technical data” on page 13). ).
1
ml/stroke of dosing pump
MAGDOS 10, 15
0.7
³
ml/m MAGDOS 6
0.5
00
0.4 10
tity:
0.3
u an ³
ingq l/m
0.2 os m MAGDOS 4
D 000
tity: 1
an ³
u l/m
0.1 gq 00
m MAGDOS 2
sin 0
0.07 Do y: 1
tit ³
uan l/m
0.05
in gq 0 0m MAGDOS 05, 1
s 0
0.04 Do ty :1
0.03 anti
g qu
sin
0.02 Do
0.01
0.1 0.2 0.3 0.5 0.7 1 2 3 4 5 7 10 20 30 50 70 100
l/pulse (water meter)
30 Operation
BA-10010-02-V01 © Lutz-Jesco GmbH 2017
Operating modes
Solenoid-diaphragm dosing pump MAGDOS LA / LD Operating instructions
Calculating the transmission factor n Use of a higher dosing pump model, e.g., MAGDOS LD 10 instead of
required dosing quantity per pulse x 100%
MAGDOS LD 6
The first calculation phase is used to determine the transmission factor n Reduction of the dosing quantity via higher concentration of the
delivery capacity per stroke
which is set in the display of the MAGDOS LD. dosing medium
n Increase of the pulse sequence of the contact-type water meter, e.g.,
The following parameters are required for this:
0.5 l/pulse instead of 1 l/pulse
n Dosing quantity per cubic metre of water in ml/m3
1 ml/pulse x 100
n Pulse sequence of water meter in l/lmp= 159 %
0,63 ml/stroke
n Delivery capacity per stroke of the dosing pump in ml/stroke
required dosing quantity per pulse x 100%
Calculate
delivery the factor
capacity using the following formula:
per stroke
Example:
1 ml/pulse x 100
= 159 %
1000
0,63mlml/stroke
of a dosing medium 1000 should
x 1be dosed per m3 of water in a water
line at 4 bar. The contact-type0,63water = 159 %
x 10meter has an pulse sequence of 1 l/
pulse. The selection table (see 30) can be used to select a MAGDOS LD
6 with 0.63 ml/stroke at 4 bar. A MAGDOS LD 10 would also come into
required dosing consideration
quantity x pulseassequence of water
it dosesdosing
0.88 meter A MAGDOS LD 15 is not suitable
ml/stroke.
required quantity per pulse x 100%
delivery capacity
as dosing per
quantity
it can only stroke x
workinatml/m³10
bar.x nominal
3delivery size of the water meter in m³/h
capacity per stroke
delivery capacity per stroke in ml/stroke
The factor to be set is calculated as follows:
1000 x 1
required dosing=quantity
159 % per pulse x 100%
0,63 x 10
1000 ml/m³ 1x ml/pulse
5 m³/h
delivery capacity per stroke= x7937
100 strokes/h
= 159 %
Calculating the necessary0,63stroke frequency
0,63 ml/stroke ml/stroke
Example:
dosing quantity in ml/m³ x nominal sizexof5 the
1000 ml/m³ water meter in m³/h
For the dosing specified above, am³/h
contact-type water meter with the
= 7937 strokes/h
delivery capacity per
0,63 stroke in
ml/stroke
nominal size of m³/h should be used. ml/stroke
ü
Dosing pump is decommissioned.
32 Operation
BA-10010-02-V01 © Lutz-Jesco GmbH 2017
External On / Off via Release input
Solenoid-diaphragm dosing pump MAGDOS LA / LD Operating instructions
12 Maintenance
The products are produced to the highest quality standards and have a 12.1 Maintenance intervals
long service life. Nevertheless, some of their parts are subject to wear
due to operation (e.g. diaphragms, valve seats, valve balls). This means
This table gives you an overview of maintenance work and the intervals
that regular visual inspections are necessary to ensure a long operating
at which you must carry it out. The next few sections contain instructions
life. Regular maintenance will protect the dosing pump from operation
for carrying out this work.
interruptions.
Mortal danger from electric shock! Check that suction and pressure Regularly
valves are seated firmly
Live parts can inflict fatal injuries.
ð
Before carrying out any maintenance work, always disconnect Clean suction and pressure valves Regularly
the dosing pump from the power supply.
Check that electrical connections are Regularly
ð
Secure the dosing pump from accidental power-up.
not damaged
CAUTION
12.2 Tighten up dosing head bolts
Danger of personal injury and material damage!
è
Tighten the dosing head bolts in diagonally opposite sequence with a
The dosing pump can generate a pressure that is many times the torque wrench.
rated one. The dosing medium can escape in the case of material The necessary torque is 180 Ncm.
failure or wear on the dosing head, the connection pipe or the seals
that are used.
ð
Carry out maintenance work at the recommended intervals.
Fig. 30: Exploded view of the diaphragm and dosing head Contaminated valves affect the dosing preceision and this means that
you should clean the valves on a regular basis.
12.3.1 Remove the old diaphragm With dosing heads made of plastic, when replacing a valve you must
replace the complete dosing head (see chapter 14 „Spare parts“ on
Precondition for action: page 37).
ü
You have disconnected the dosing pump from the mains supply.
ü
You have depressurised the hydraulic sections of the plant.
ü
You have rinsed the dosing pump using a safe medium (e.g. water).
1. Screw out the four screws (5) on the dosing head using a suitable tool
(SW 3 Allen key) and take off the dosing head (4).
2. Use pliers to bend the edge of the diaphragm (3) slightly upwards and
screw it out counter-clockwise.
34 Maintenance
BA-10010-02-V01 © Lutz-Jesco GmbH 2017
Change the diaphragm
Solenoid-diaphragm dosing pump MAGDOS LA / LD Operating instructions
13 Troubleshooting
See below for information about how to rectify faults on the device or the Possible cause Remedy
system. If you cannot eliminate the fault, please consult with the
manufacturer on further measures or return the dosing pump for repair. Conductive rubber bands not è
Insert conductive rubber bands
inserted in connection correctly
sockets or not inserted
13.1 Type of fault correctly
Table 27: Type of fault: Dosing pump not delivering or output too low
13.1.1 Dosing pump not delivering or output too low
13.1.2 Dosing pump does not prime
Possible cause Remedy
Table 29: Type of fault: Delivery rate varies System backpressure too è
Clean blocked injection nozzle.
high (measured at discharge
è
Install pulsation dampeners to
13.1.4 No stroke movement observed connection of dosing pump)
reduce pressure peaks if pipes
are too long.
Possible cause Remedy è
Check function of safety valves.
Diaphragm return spring è
Contact the manufacturer. Media sediment in dosing è
Clean the dosing head.
broken. head
Current supply interrupted è
Reconnect the current supply Table 32: Type of fault: Diaphragm is torn or tears too often
36 Troubleshooting
BA-10010-02-V01 © Lutz-Jesco GmbH 2017
Type of fault
Solenoid-diaphragm dosing pump MAGDOS LA / LD Operating instructions
14 Spare parts
6, 10, 15 38980
c
a
PVDF Type Part No.
6, 10, 15 38986
Diaphragm spare parts set containing: Set of conductive rubber bands (2 pcs) 40036
n 1 Diaphragm (item 1)
Set of covering caps M12x1 (3 pcs) 40319
n 1 set of dosing head screws (item 3),
05, 1 39121
2, 4 39122
6, 10, 15 39123
6, 10, 15 38983
This Chapter is intended to give you an idea of the delivery capacity that
the dosing pump can achieve at specific back pressures. These delivery
capacities were determined on the manufacturer's test stands. They
apply at 20 °C (68 °F) for water, at 100 % stroke frequency. The delivery
capacity depends on the medium (density and viscosity) and tempera-
ture. Since these conditions vary at every installation location, you should
calibrate the dosing pump.
6
Delivery capacity [l/h]
4 2
1
2
1 05
0
0 2 4 6 8 10 12 14 16
Pressure [bar]
16
Delivery capacity [l/h]
15
14
12 10
10
6
8
0
0 2 4 6 8
Pressure [bar]
16 EC Declaration of Conformity
(DE) EU-Konformitätserklärung
Hiermit erklären wir, dass das nachfolgend bezeichnete Gerät aufgrund seiner Konzipierung und Bauart sowie in der von uns in Verkehr gebrachten Ausführung
den einschlägigen grundlegenden Sicherheits- und Gesundheitsanforderungen der aufgeführten EG-Richtlinien entspricht. Bei einer nicht mit uns abgestimmten
Änderung am Gerät verliert diese Erklärung ihre Gültigkeit.
(NL) EU-overeenstemmingsverklaring
Ondergetekende Lutz-Jesco GmbH, bevestigt, dat het volgende genoemde apparaat in de door ons in de handel gebrachte uitvoering voldoet aan de eis van, en in
overeenstemming is met de EU-richtlijnen, de EU-veiligheidsstandaard en de voor het product specifieke standaard. Bij een niet met ons afgestemde verandering
aan het apparaat verliest deze verklaring haar geldigheid.
Typ: MAGDOS LA 05 – 15
Type: MAGDOS LD 05 – 15
17 Declaration of no objection
Please copy the declaration, stick it to the outside of the packaging and
return it with the device.
Declaration of no objection
Please fill out a separate form for each appliance!
..................................................................................................................................................................................................................
..................................................................................................................................................................................................................
Dosing medium
We hereby certify, that the product has been cleaned thoroughly inside and outside before returning, that it is free from hazardous
material (i.e. chemical, biological, toxic, flammable, and radioactive material) and that the lubricant has been drained.
If the manufacturer finds it necessary to carry out further cleaning work, we accept the charge will be made to us.
We assure that the aforementioned information is correct and complete and that the unit is dispatched according to the legal
requirements.
..................................................................................................... Fax:..........................................................................................
..................................................................................................... Email:.......................................................................................
Date, Signature:............................................................................
18 Warranty claim
Warranty claim
Please copy and send it back with the unit!
If the device breaks down within the period of warranty, please return it in a cleaned condition with the complete warranty claim.
Sender
Company: ............................................................................................................... Phone: .................................. Date: ..........................
Address: ....................................................................................................................................................................................................
Contact person: .........................................................................................................................................................................................
Manufacturer order no.: .......................................................................................... Date of delivery: .........................................................
Device type: ............................................................................................................ Serial number: ...........................................................
Nominal capacity / nominal pressure: .........................................................................................................................................................
Description of fault:.....................................................................................................................................................................................
...................................................................................................................................................................................................................
...................................................................................................................................................................................................................
...................................................................................................................................................................................................................
...................................................................................................................................................................................................................
...................................................................................................................................................................................................................
...................................................................................................................................................................................................................
...................................................................................................................................................................................................................
Please describe the specific installation and enclose a simple drawing or picture of the chemical feed system, showing materials of const-
ruction, diameters, lengths and heights of suction and discharge lines.
19 Index
A H
Accessories ......................................................................................20 Handling instructions
Analog input Marking .........................................................................................5
Connection ..................................................................................23 Hazards due to non-compliance with the safety instructions ...............7
Approved media temperature ............................................................14 Hydraulic accessories .......................................................................20
Hydraulic connections .......................................................................18
B Hydraulic installations .......................................................................17
Back-pressure valve .........................................................................20
I
C Injection nozzle .................................................................................20
Inputs of the control unit ...................................................................23
Cemented connection .......................................................................19
Installation ........................................................................................16
Clean suction and pressure valves ....................................................34
hydraulic .....................................................................................17
Commissioning the dosing pump ......................................................27
Installing the Dosing Pump ...............................................................16
Connection sockets ..........................................................................23
Intended purpose ................................................................................9
Contact water meter .........................................................................20
Intended use .......................................................................................9
Control ..............................................................................................25
Control elements ..............................................................................12
L
D Leakage drain ...................................................................................19
Level monitoring ...............................................................................21
Decommissioning the dosing pump ..................................................32
Delivery capacity data ......................................................................13
Delivery characteristic curves ...........................................................38 M
Design of the system ........................................................................17 Maintenance ...............................................................................33, 37
Device revision ...................................................................................9 Maintenance intervals .......................................................................33
Diaphragms
N
Replace .......................................................................................34
Spare parts set ............................................................................37
Notes for the Reader ...........................................................................4
Dimensioned drawings .....................................................................15
Dimensions .......................................................................................15
Disposal of old equipment .................................................................32 O
Dosing head Operating conditions and limits .........................................................13
Alignment ....................................................................................18 Operating modes ..............................................................................28
Design .........................................................................................11 Explanation of the icons ...............................................................25
Spare parts ..................................................................................37 Operation ....................................................................................27, 33
Dosing head venting facility ..............................................................19 Operator controls of the control unit ..................................................25
Dosing media
P
Approved media temperature ......................................................14
Prohibited dosing media ................................................................9
Personnel qualification ........................................................................7
Pressure-relief valve .........................................................................20
E Priming aid .......................................................................................21
EC Declaration of Conformity ............................................................39 Product description ...........................................................................11
Electrical specifications ....................................................................14 Product warranty ................................................................................9
External On / Off via Release input ....................................................32 Prohibited dosing media .....................................................................9
Pulsation dampener ..........................................................................20
F Pulse input
Connection ..................................................................................24
Foreseeable misuse ............................................................................9
Function description .........................................................................12
R
G Rating plate ......................................................................................12
Release code ....................................................................................25
General warnings ................................................................................6
Release input ....................................................................................23
Glue-in connection ............................................................................19
S
Safety .................................................................................................6
Scope of delivery ..............................................................................11
Set up information ............................................................................16
Shutdown ...................................................................................32, 33
Shutting down in an emergency ........................................................32
Signal words
Explanation ...................................................................................4
Spare parts .......................................................................................37
Specialist staff ....................................................................................8
Start-up ......................................................................................22, 27
Storage .............................................................................................32
Structure of the dosing pump ............................................................11
Suction pressure regulator ................................................................21
Suspensions .....................................................................................21
System piping ...................................................................................17
T
Technical data ..................................................................................13
Temperatures
Approved ambient temperature ...................................................13
Approved media temperature ......................................................14
Tighten up dosing head bolts ............................................................33
Transportation ..................................................................................32
Troubleshooting ................................................................................35
V
Venting .............................................................................................27
Venting the dosing pump ..................................................................27
W
Wall bracket .....................................................................................16
Wall mounting ...................................................................................16
Warnings
General warnings ..........................................................................6
Marking .........................................................................................4
Warning sign
Explanation ...................................................................................4
Warranty claim .................................................................................41
Water meter .....................................................................................20
Working in a safety-conscious manner ...............................................7
The Lutz-Jesco App for iPads and iPhones is available from the iTunes App Store.
Additional information can be found at www.lutz-jesco.com
Tel.: +49 5130 5802-0 Tel.: +36 96 419813 Tel.: +43 2256 62180 Tel.: +31 180 499460
Fax: +49 5130 580268 Fax: +36 96 419814 Fax: +43 2256 6218062 Fax: +31 180 497516
Tel.: +44 121 782 2662 Tel.: +1 585 426-0990 Tel.: +603 55692322 Tel.: +971 6 5572205
Fax: +44 121 782 2680 Fax: +1 585 426-4025 Fax: +603 55691322 Fax: +971 6 5572230