Tabel Hasil
Tabel Hasil
Hot Flow Cold Flow Hot Water Cold Water Hot Water Temperature Cold Water Temperature
(ft3/jam) (ft3/jam) Temperature (oF) Temperature (oF) (oF) (oF)
5,297 5,9328 115,88 115,16 74,12 90,86 141,44 125,78 86,36 101,3
Time Flowrate Hot Water Cold Water Hot Water Cold Water
(s) (ft3/jam) Temperature (oF) Temperature (oF) Temperature (oF) Temperature(oF)
Tabel 2.7 Hasil Perhitungan Kecepatan Perpindahan Panas Cold Fluid pada Concentric Cocurrent
Cold Flow TC1 TC2 TC avg ρ Cp mc qc
No,
(ft3/jam) (oF) (oF) (oF) (lb/ft3) ( Btu/lb oF) (lb/jam) (Btu/jam)
1 7,2042 85,64 99,68 92,66 62,0811 0,9986 447,2415 6270,4177
2 6,5685 73,94 98,06 86 62,1603 0,9986 408,2995 9834,2978
3 5,9328 74,12 90,86 82,49 62,1944 0,9987 368,9889 6168,7396
4 5,2972 82,94 109,04 95,99 62,0415 0,9993 328,6442 8571,4410
5 4,4496 85,1 101,48 93,29 62,0736 0,9994 276,2041 4521,2908
Tabel 2.8 Hasil Perhitungan Koefisien Perpindahan Panas Overall pada Concentric Cocurrent
LMTD Uo Ui Um
No,
(oF) (Btu /jam ft2 oF) (Btu /jam ft2 oF) (Btu /jam ft2 oF)
1 9,8571 -8,8518 1109,7444 -6,2162
2 28,5022 131,2706 601,9199 92,1844
3 32,2460 10,7977 333,7299 7,5827
4 21,8669 298,0513 683,8179 209,3057
5 33,1460 308,9312 237,9613 216,9461
Tabel 2.9 Hasil Perhitungan Keefektifan Heat Exchanger pada Concentric Cocurrent
Rf
(mxCp)hot (mxCp)cold (mxCp)min q actual Thavg - Tcavg
No, Keefektifan (∈) (jam ft2
(Btu/jam oF) (Btu/jam oF) (Btu/jam oF) (Btu/jam) (oF) o
F/Btu)
1 327,6707 446,6110 327,6707 -58,9807 6,3500 -0,0283 0,0026
2 326,7648 407,7238 326,7648 2529,1597 17,4500 0,4436 0,0027
3 326,8934 368,5030 326,8934 235,3632 18,3500 0,0392 0,0027
4 326,3434 328,4077 328,4077 4405,6356 15,3000 0,8768 0,0026
5 325,8874 276,0251 276,0251 4521,2908 20,3500 0,8049 0,0026
Tabel 2.10 Hasil Perhitungan Kecepatan Perpindahan Panas Hot Fluid pada Concentric Counter Current
TH1 TH2 ρ Cp mh qh
No, Hot Flow (ft3/jam) THavg (oF)
(oF) (oF) (lb/ft3) ( Btu/lb oF) (lb/jam) (Btu/jam)
1 135,5 127,04 131,27 61,5299 0,9996 325,9345 2756,1920
2 144,68 129,92 137,3 61,4289 0,9999 325,3994 4802,3181
3 5,297 141,44 125,78 133,61 61,4907 0,9997 325,7269 5099,2706
4 152,6 145,22 148,91 60,7489 1,0006 321,7975 2376,3241
5 154,4 146,84 150,62 60,6271 1,0007 321,1522 2429,6772
Tabel 2.11 Hasil Perhitungan Kecepatan Perpindahan Panas Cold Fluid pada Concentric Counter Current
Cold Flow TC1 TC2 TC avg ρ Cp mc qc
No,
(ft3/jam) (oF) (oF) (oF) (lb/ft3) ( Btu/lb oF) (lb/jam) (Btu/jam)
1 0,0034 68,36 102,74 85,55 62,1647 0,9986 447,8438 15375,3451
2 0,0031 86,72 102,74 94,73 62,1306 0,9986 408,1046 6530,2254
3 0,0028 86,36 101,3 93,83 62,1603 0,9986 368,7866 5501,9037
4 0,0025 84,2 92,12 88,16 62,0571 0,9986 328,7269 2599,8464
5 0,0022 86,36 93,74 90,05 62,1121 0,9986 289,5363 2133,7653
Tabel 2.12 Hasil Perhitungan Koefisien Perpindahan Panas Overall pada Concentric Counter Current
LMTD Uo Ui Um
No,
(oF) (Btu /jam ft2 oF) (Btu /jam ft2 oF) (Btu /jam ft2 oF)
1 44,4680 91,6921 292,5280 64,3905
2 42,5669 166,8973 68,2580 117,2031
3 39,7789 189,6380 50,6130 133,1728
4 60,7496 57,8672 78,3772 40,6371
5 60,5700 59,3419 62,7277 41,6727
Tabel 2.13 Hasil Perhitungan Keefektifan Heat Exchanger pada Concentric Counter Current
(mxCp)hot (mxCp)cold (mxCp)min Q actual Thavg - Tcavg Rf
No, Keefektifan (∈)
(Btu/jam oF) (Btu/jam oF) (Btu/jam oF) (Btu/jam) (oF) (jam ft2 oF/Btu)
1 325,7910 447,2177 325,7910 15375,3451 67,1400 0,7029
2 325,3603 407,6296 325,3603 4802,3181 57,9600 0,2547
3 325,6239 368,2666 325,6239 5099,2706 55,0800 0,2843 0,0013
4 321,9951 328,2634 321,9951 2376,3241 68,4000 0,1079
5 321,3859 289,1281 289,1281 2133,7653 68,0400 0,1085
Tabel 2.14 Hasil Perhitungan Kecepatan Transfer Panas pada Jacket Batch Operation 0 rpm Hot Fluid
Time Flowrate TH1 TH2 THavg ρ Cp mh qh
(s) (ft3/jam) (oF) (oF) (oF) (lb/ft3) ( Btu/lb oF) (lb/jam) (Btu/jam)
0 154,22 154,58 154,4 61,0840 1,0010 323,5626 -116,5965
1 163,76 176,72 170,24 60,7794 1,0024 321,9492 -4182,2846
2 5,297 144,32 156,74 150,53 61,1645 1,0007 323,9892 -4026,8499
3 145,04 139,82 142,43 60,6827 1,0002 321,4369 1678,2099
4 145,76 152,78 149,27 60,9084 1,0006 322,6325 -2266,3251
5 136,04 160,52 148,28 61,2450 1,0005 324,4152 -7945,3575
Tabel 2.15 Hasil Perhitungan Kecepatan Transfer Panas pada Jacket Batch Operation 0 rpm Cold Fluid
Cp
TC5 ρ mc TC5n-TC5n-1 qc
Time(s) Volume (ft3) ( Btu/lb
(oF) (lb/ft3) o (lb/jam) (oF) (Btu/jam)
F)
0 91,94 62,1401 0,9989 4,8283 8,82 -
1 100,76 62,1101 0,9987 4,8260 3,02 2552,3445
2 103,784 62,0999 0,9986 4,8252 6,16 874,4624
0,0777
3 109,94 62,0035 0,9987 4,8177 3,96 1779,7180
4 113,9 61,8990 0,9989 4,8096 5,94 1143,2457
5 119,84 61,7422 0,9990 4,7974 8,82 1712,1580
Tabel 2.16 Hasil Perhitungan Kecepatan Transfer Panas pada Jacket Batch Operation 300 rpm Hot Fluid
Time Flowrate TH1 TH2 THavg ρ Cp mh Qh
(s) (ft3/jam) (oF) (oF) (oF) (lb/ft3) ( Btu/lb oF) (lb/jam) (Btu/jam)
0 142,52 149 145,76 61,2638 1,0072 324,5150 -2118,0535
1 154,4 138,56 146,48 61,2488 1,0069 324,4356 5174,3813
2 5,297 157,1 150,98 154,04 61,0915 1,0032 323,6023 1986,7071
3 169,16 173,48 171,32 60,7592 1,0025 321,8419 -1393,7695
4 163,94 157,64 160,79 60,9510 0,9998 322,8582 2033,6967
5 141,08 140,18 140,63 61,3706 1,0097 325,0805 295,4236
Tabel 2.17 Hasil Perhitungan Kecepatan Transfer Panas pada Jacket Batch Operation 300 rpm Cold Fluid
Time Volume TC5 ρ Cp mc TC5n-TC5n-1 qc
(s) (ft3/jam) (oF) (lb/ft3) ( Btu/lb oF) (lb/jam) (oF) (Btu/jam)
0 126,68 61,9783 0,9991 4,8157 5,94 -
1 132,62 61,9697 0,9991 4,8150 4,32 116883,5377
2 136,94 61,9279 0,9992 4,8118 -29,16 84954,9329
0,0777
3 107,78 61,8783 0,9992 4,8079 -22,14 -573014,0671
4 85,64 61,9890 0,9991 4,8165 0,90 -435781,8905
5 86,54 61,9804 0,9991 4,8159 5,94 17712,2632
Tabel 2.18 Hasil Perhitungan Kecepatan Transfer Panas pada Jacket Continuous Operation 0 rpm Hot Fluid
Time Flowrate qh mh ρ Cp TH1 TH2 TH avg
(s) (ft3/jam) (Btu/jam) (lb/jam) (lb/ft3) (Btu/lb oF) (oF) (oF) (oF)
0 232,2991 321,8316 60,7572 1,0025 172,22 171,5 171,86
1 9123,4044 319,1615 60,2531 1,0051 208,76 180,32 194,54
2 3776,4654 322,0194 60,7927 1,0023 176 164,3 170,15
5,297
3 -173,7881 320,6792 60,5397 1,0036 181,58 182,12 181,85
4 7926,5617 320,0997 60,4303 1,0042 199,04 174,38 186,71
5 1846,7582 318,8853 60,2010 1,0054 199,58 193,82 196,7
Tabel 2.19 Hasil Perhitungan Kecepatan Transfer Panas pada Jacket Continuous Operation 0 rpm Cold Fluid
Time Flowrate TC1 TC4 TCavg ρ Cp mc qc
(s) (ft3/jam (oF) (oF) (oF) (lb/ft3) (Btu/lb oF) (lb/jam) (Btu/jam)
0 68,36 75,92 72,14 62,2865 0,9992 329,9321 2492,3305
1 69,08 86,18 77,63 62,2416 0,9988 329,6943 5631,0758
2 77,36 80,06 78,71 62,2311 0,9988 329,6387 888,9419
5,297
3 86,36 102,02 94,19 62,0629 0,9986 328,7476 5140,9294
4 89,96 89,78 89,87 62,1143 0,9986 329,0199 -59,1401
5 86,72 98,24 92,48 62,0832 0,9986 328,8554 3783,0727
Tabel 2.20 Hasil Perhitungan Kecepatan Transfer Panas pada Jacket Continuous Operation 300 rpm Hot Fluid
Time Flowrate qh mh ρ Cp TH1 TH2 TH avg
(s) (ft3/jam) (Btu/jam) (lb/jam) (lb/ft3) (Btu/lb oF) (oF) (oF) (oF)
0 -14616,4743 309,0519 58,3446 1,0029 159,08 206,24 182,66
1 4494,8696 324,0636 61,1786 1,0007 157,82 143,96 150,89
2 3732,6754 313,5320 59,1904 1,0021 177,62 165,74 171,68
5,297
3 5155,5740 321,6274 60,7187 1,0006 156,74 140,72 148,73
4 6998,8621 321,1195 60,6228 1,0007 161,06 139,28 150,17
5 16722,4072 315,4368 59,5500 1,0018 192,74 139,82 166,28
Tabel 2.21 Hasil Perhitungan Kecepatan Transfer Panas pada Jacket Continuous Operation 300 rpm Cold Fluid
Time Flowrate TC1 TC4 TCavg ρ Cp mc qc
(s) (ft3/jam) (oF) (oF) (oF) (lb/ft3) (Btu/lb oF) (lb/jam) (Btu/jam)
0 77,36 100,4 88,88 62,1260 329,0823 7571,3649
1 87,8 87,62 87,71 62,1400 329,1560 -59,1645
2 5,297 96,26 100,22 98,24 62,0147 0,9986 328,4924 1298,9959
3 87,62 100,22 93,92 62,0661 328,7647 4136,5941
4 91,4 86,9 89,15 62,1228 329,0652 -1478,7057
5 90,14 88,52 89,33 62,1207 329,0539 -532,3157
Tabel 2.22 Hasil Perhitungan Keefektifan Jacket Batch Operation 0 dan 300 rpm
0 rpm 300 rpm
Time
Flowrate
(s) Hot Water (oF) Cold Water (oF) Hot Water (oF) Cold Water (oF) hj
(ft3/jam)
∈ ∈ (Btu/hr ft2 °F)
TH1 TH2 TC5 TH1 TH2 161,5913
0 154,22 154,58 91,94 - 142,52 149 155,2995 - 161,5913
1 163,76 176,72 100,76 0,8772 154,4 138,56 150,9283 0,7857 155,2995
2 144,32 156,74 103,784 0,7739 157,1 150,98 157,1931 0,6627 150,9283
5,297
3 145,04 139,82 109,94 0,6610 169,16 173,48 142,6581 1,4449 157,1931
4 145,76 152,78 113,9 0,5920 163,94 157,64 144,4120 2,1014 142,6581
5 136,04 160,52 119,84 0,3673 141,08 140,18 86,54 3,7875 144,4120