Conversion from Cu150 to Cu200

Project Specification
2.7.2 Concrete Mix Design
Table - Concrete Class, Compressive Strength and Point-of-use Cu150
Class Age Compressive Strength Point-of-use
Cu 150
Class K-125 7 day 85 kg/cm 2
No use
28 day 125 kg/cm2
Cu150 Class K-175 7 day 120 kg/cm2 Slab on Grade
28 day 175 kg/cm2
Cu150 Class K-225 7 day 150 kg/cm2 Structural Body
28 day 225 kg/cm2

Now our test Cu150


Cu150 Class K-250 7 day ???? kg/cm2 Trial mix
28 day 250 kg/cm 2

Cu150 Class K-275 7 day ???? kg/cm2 Trial mix


28 day 275 kg/cm2

Result Judgement (28 days) by PBI-1971


I. Average of 3 samples should be same or over nominal value Is correct??
II. None of 3 should be below 95% of nominal value Is correct??
(95 % of designed value)
Conversion from PSI to N/mm2
Basic
π 3.1415927
Area of Cylinder 28.2743 inch2 ← (3" x 3" x π)
(6"x12) 18,241.5 mm2 ← (3 x 25.4/2) x (3 x 25.4/2 ) x π
Conversion
1 PSI = 0.00689476 N/mm2
1 pounds (lb) = 0.00444822 kN Actual practice
1 kN/mm2= 1,000 N/mm2 PSI (Pound(lb)/inch2) (Surface of Cylinder)
Load 6"x 12"
Unit 112,650.0 lb ÷ 28.2743
PSI [Pound(lb)/inch2] Load(lb) ÷ Area (inch2) ⇒
N/mm2 (Surface of Cylinder)
Load 6"x 12"
501.0919830 KN ÷ 18,241.5
kN/mm2 Load(kN) ÷ Area (mm2) ⇒

By Direct Conversion
3984.2 PSI x 0.00689476

PSI to N/mm2 Conversion method to be used


example)
3000 PSI x 0.00689476
Result Judgement (28 days) by JIS A 5308
I. Average of 3 samples ≧ 27.00 N/mm2
II. Each sample ≧ 22.95 N/mm2 ← (27.00 N/mm2 x 85%)
(85 % of designed value)
ace of Cylinder)

inch2 = 3984.2 PSI

ace of Cylinder)

mm2 = 0.027470 KN/mm2


↓ x 1000
27.469935 N/mm2
effective
= 27.469956 N/mm2

= 20.68428 N/mm2
↑ no rounding