BSC MAINTENANCE: 4.BSC MAINTENANCE (b).

Alarms & Commands to Handle Alarms:-


ZEEI; // To see the status of the site.
ZEEP; // To see all the site & its BCF IDs.
ZEEL:BL; // To see the Blocked TRX in whole BSC.
ZEOL:BCF NO; // To check the current alarm in the site.
ZEOH::BCF=BCF NO; // To check history of alarm.
ZEOR:BCF NO:ALARM NO(10001-65534); // To cancel an alarm.
ZEFS:BCF NO:L/U; // To give site reset.
ZEFR:BCF NO:SITE/OMU; // To give site reset in safe mode also OMU reset.
ZEQS:BTS=BTS NO:L/U; // To give sector reset.
ZERS:BTS=BTS NO,TRX=TRX NO:L/U; // To give TRX reset.
ZERM:BTS=BTS NO,TRX=TRX NO:GTRX=Y/N; // To give reset if TRX is blocked by system.
ZERM:BTS=BTS NO,TRX=TRX NO:PREF=P/N; // To change preference for ACTIVE TRX.
ZWAT; // To check BSC alarm TEXT ID.
ZAHO::NR=4000-4007; // To check BSC alarm.
ZAHO:ET,ET NO; // To check ET alarm.
ZAHP; // To check ET & BSC history alarms.
ZYEF:ET,ET NO; // To check PCM service state. Alarm Indicator

Alarms from BTS : Alarms from BTS


ZDTI:::PCM=ET NO; // To check signalling link for a site.
ZDSB:::PCM=ET NO; // To check TIE value & BIT rate.
ZUSC:ET,ET NO:BL/WO; // To give ET reset.
ZDTC:LAPD NAME:BL/WO; // To give LAPD reset.
ZYMO:ET,ET NO; // To check SLIPS.
ZUSI:ET,ET NO; // To check ET status.
ZWUP:ET NO; // To check the type of ET (ABIS or SIGNALLING).
ZERO:BCF=BCF NO; // To check traffic of the TRX.
ZEUO:BTS=BTS NO; // To check BTS POWER.
ZEUG:BTS=BTS NO:PMAX1=(1,2�43); // To change BTS POWER.
ZEQV:BTS=BTS NO:GENA=Y/N; // To enable/disable GPRS.
ZEQO:BTS=BTS NO:GPRS; // To check GPRS ENABLED OR NOT for BTS.
ZFWO:BCSU=0&&6; // To check GPRS for particular BSC.
ZACC:CONSECUTIVE NO(XXXX); // To delete BSC Alarm.

BTS UNITS:
OMU OPERATION & MAINTENANCE UNIT
MCMU MARKER AND CELLULAR MANAGEMENT UNIT
BCSU BASE STATION CONTROLLER SIGNALLING UNIT
CLS CLOCK & SYNCHRONIZATION UNIT
MB MESSAGE BUS
ET EXCHANGE TERMINAL
TCSM TRANSCODER SUBMULTIPLEXER
GENA GPRS ENABLED