Professional Documents
Culture Documents
AZUD DISC FILTER 세미나 자료 PDF
AZUD DISC FILTER 세미나 자료 PDF
Our Course
Sistema AZUD S.A was founded more than thirty years ago. AZUD prides in to
be among the world leaders regarding the manufacturing of filtration and
irrigation systems (agricultural, industrial and urban). An achievement
attributed to the innovation of its products and systems, and above all, thanks
to a close co-operation with its clients.
Objective
AZUD filtration systems not only satisfy the objectives set but also they are
reached with the minimum interference in the system and the
minimum volume of water to make the autonomous cleaning.
Technology & advantages: Discs
» Cooling Tower: Footprint saving and reduction of the chemical products cost.
» Process Water: Process line protection (extruders, injectors, mining lines…), avoiding
unnecessary stops in the productive process. .
» Recirculation Process: Saving of water and energy and decreasing of waste water
volume.
Systems
The water goes from outside to the inner of the piled up discs
that have channels in both sides.
- Easy cleaning.
- Surface filtration.
WHAT IS AN AUTOMATIC FILTER: WORKING AND
COMPONENTS OF THE SYSTEM.
Filtration Self-cleaning
During the filtration process the water is driven The three-way valve closes the entrance of
from the inlet manifold to the inner of the filters water to the filter, communicating the inside of
and through the “anti-clogging device”, which the filter with the drainage manifold. The water
generates the HELIX EFFECT. The only filtered by the rest of the filters introduces itself
passage of water is through the channels of to the filter at the opposite direction. This
the stacked discs. The most part of the solids generates the decompression of the stack of
are retained in the filtering element before the discs thanks to the raising of the piston. The
water moves to the outlet manifold. tangential projection of the water from the
inner of the filtering element allows the
evacuation of the solids retained by the discs.
FILTERS
The automatic filter is a device which serves to treat the water LID
DF-DISC
LOCK SYSTEN
BASE
MANIFOLDS.
- Manufactured in High Density Polyethylene (HDPE).
- Easy installation.
- Maximum resistance and durability.
- High resistance to chemical products.
- Inalterability to the microbial aggression.
- High resistance to impacts.
- Suitable to the agricultural and industrial filtration.
- ¾” Auxiliary intakes with metallic reinforcement.
COMPONENTS
BACKFLUSHING VALVES
COMPONENTS
CONTROL UNIT
AZUD FBC Control Unit incorporates a whole set integrating
the detection, control and activation systems of the
Backflushing cycles.
The control unit is in charge of sending the signal to the
filtration equipment to the carrying out of a Backflushing cycle.
It allows to backflush how, when, and during the time according
to the specific needs of each installation. There are available
12V, HP, SW or AA UC, according to the specific needs of each
installation.
EQUIPMENTS
Self-cleaning
The three-way valve closes the entrance of water to the filter,
communicating the inside of the filter with the drainage
manifold. The water filtered by the rest of the filters introduces
itself to the filter at the opposite direction. This generates the
decompression of the stack of discs thanks to the raising of the
piston. The tangential projection of the water from the inner of
the filtering element allows the evacuation of the solids retained
by the discs.
To Different Systems
The hydraulic requirements to make the self-cleaning are given by a external source of pressured air which
allows generating the “propulsion” of accumulated water in the “storage device” and the post-mixture with
the injected air in the auxiliary manifold.
To Different Systems
AZUD HELIX AUTOMATIC DLP
BACKFLUSHING LOW PRESSURE STAGE: The clean water is introduced from the reverse direction
through the filtering element. This decompresses the stack discs, allowing the discs to separate and
backwash efficiently.
The solids are expelled from the discs and evacuated through the backwash manifold.
The filtration process then restarts with the compression of the discs.
To Different Systems
Self-cleaning
The three-way valve closes the entrance of water to the filter,
communicating the inside of the filter with the drainage
manifold. The water filtered by the rest of the filters introduces
itself to the filter at the opposite direction. This generates the
decompression of the stack of discs thanks to the raising of the
piston. The tangential projection of the water from the inner of
the filtering element allows the evacuation of the solids retained
by the discs.
The hydraulic requirements to make the self-cleaning are given by a external source of pressured air which
allows generating the “propulsion” of accumulated water in the “storage device” and the post-mixture with
the injected air in the auxiliary manifold.
BACKFLUSHING LOW PRESSURE STAGE: The clean water is introduced from the reverse direction
through the filtering element. This decompresses the stack discs, allowing the discs to separate and
backwash efficiently.
The solids are expelled from the discs and evacuated through the backwash manifold.
The filtration process then restarts with the compression of the discs.
≤6 bar
4DCL AW DLP
Neumatic 4DCL3 a 4DCL12
2
GOOD m3/h 36 32 24 17 9 7 6
WATER gpm 157 139 101 77 38 31 26
AVERAGE m3/h 32 30 20 14 7 5 4
WATER gpm 139 131 88 61 31 23 18
POOR m3/h 26 24 18 10 5 4 3
WATER gpm 113 105 79 46 23 18 15
pH range 4-11
Is the easiest combination we have. It has only one filtering element with 2” BSP
connection: 201= 1 filter of 2”
Filtering surface
per filter 2S" = 1492 cm2 / 231 in2
SERIE 201 DLP & 201 AW DLP
It is made by one 2” SUPER self-cleaning filter with HELIX system; discs filtering element easily removable without tools.
Is the easiest combination we have. It has only one filtering element with 2” BSP connection: 201= 1 filter of 2”
AZUD HELIX AUTOMATIC DLP allows the reduction of the energetic use of the filtration installations, increasing their
performance, and demanding the minimal pressure consumptions and flow rate on each backwashing, keeping the
maximum efficiency in a wide filtration grades range.
Max. Working pressure 6 bar / 87 psi Furthermore, with the patented HELIX system, the frequency
Min. working pressure 1.2 bar / 17,5 psi and intensity of the maintenance labours of the system are
minimized.
Max. Temperature 60º / 140ºF
The energetic cost is dramatically reduced per filtered m3 in the
pH range 4-11 installation, minimizing the environmental impact.
DLP
Inlet 2"- 50 mm PVC 1.492
24
SERIE
201 1 Outlet 2"- 50 mm BSP Metal
200 106 Filtering surface
Drainage 2"- 50 mm BSP Metal 231
per filter 2S" = 1492 cm2 / 231 in2
SERIE 201 AA & 201 AW AA
It is the easiest combination we have. It has one filtering element with 2” Grooved connection and a
“deposit” filter, which storages the water to inject it with the air in the backflushing process: 201 = 1 filter
of 2”
It is integrated by one 2” SUPER self-cleaning filter with helix system, disc filtering element and one
water deposit (the second filter does not have cartridge on it).
Max. Working 10 bar / 145 psi
pressure. AZUD HELIX AUTOMATIC AA equipments are designed to the
Min. working pressure. 0.8 bar / 11.6 psi installations where minimize the volume of water used in the self-
Max. Temperature 60º / 140º F
cleaning is a priority.
pH range 4-11
They permit to make a whole backflushing cycle making
independent the backflushing system from the filtration circuit, and
minimizing the volume of water used to the backflushing of each
filter.
BACFLUSHING PROCESS
AZUD HELIX AUTOMATIC AW AA are specifically designed to
0.8 bar
Min. Backflushing pressure optimize the filtration in the installations with limited salinity
11.6 psi
conditions, as the exposition to the corrosive action of saline
Backflushing
10 l waters of low salinity, in conditions with slight levels of saline
flow rate per filter
2.64 gpm concentration.
6 bar
Air Injection
87 psi If the application is for aggressive waters, the combination AW AA and its
System
1200 l/minute characteristics are exactly the same, but all the components are perfectly designed to
317 gpm
be in contact with this type of water without getting damaged by this reason.
Max. Flow
N. Diameter Filtering surface
130 micron
Model of filters inlet/outlet Connection cm2
m3/h
manifold in²
gpm
48 2.984
202/3FX Flange
2 3” – 90 mm
202/3VX Grooved
211 463
203/3FX Flange
203/3VX 72 3” – 90 mm Grooved 4.476
3
203/4FX 317 4” – 110 mm Flange 694
203/4VX Grooved
204/4FX Flange
204/4VX 96 4” – 110 mm Grooved 5.968
4
204/6FX 422 6” – 160 mm Flange 925
204/6VX Grooved
SERIE Combinaciones Flange
205/4FX
200 120 de 2 hasta 8 4” – 110 mm Grooved 7.460
205/4VX
filtros
5
205/6FX 528 6” – 160 mm Flange 1.156
205/6VX Grooved
208/6FX Flange
208/6VX 192 6” – 160 mm Grooved 11.936 Filtering surface per filter 2S" = 1492 cm2 / 231 in2
8
208/8FX 845 8” – 200 mm Flange 1.850 Max. Working pressure. 10 bar / 145 psi
208/8VX Grooved
Min. working pressure. 1.5 bar / 22 psi
Drainage manifold of 3”- 90 mm grooved connection elements and / or to glue. Max. Temperature 60º / 140º F
pH range 4-11
MG DISC WALL DISC
BACFLUSHING
PROCESS
400-200-130 -100 micron 130-100-50-20-10-5 micron SERIE 200 DLP & 200 AW DLP
Min. Backflushing
1.5 bar AZUD HELIX AUTOMATIC DLP allows the reduction of the energetic
1.3 bar
pressure
22 psi 19 psi use of the filtration installations, increasing their performance, and
2.5 l/s 2 l/s
demanding the minimal pressure consumptions and flow rate on each
Backflushing flow rate
per filter backwashing, keeping the maximum efficiency in a wide filtration
40 gpm 32 gpm
grades range.
Furthermore, with the patented HELIX system, the frequency and intensity of the maintenance labours of the system are
minimized.
The energetic cost is dramatically reduced per filtered m3 in the installation, minimizing the environmental impact.
AZUD HELIX AUTOMATIC AW are specifically designed to optimize the filtration in the installations with limited salinity
Max. Flow N. Filtering conditions, as the exposition to the
Diameter
Model
130 micron
m /h 3
of
filters
inlet/outlet Connection
surface
cm
corrosive action of saline waters of
2
gpm
manifold
in² low salinity, in conditions with slight
202/3FX
48
Flange
2.984 levels of saline concentration.
2 3” – 90 mm
202/3VX Grooved
211 463
203/3FX Flange
If the application is for aggressive
203/3VX 72 3” – 90 mm Grooved 4.476 waters, the combination AW DLP
3
203/4FX 317 4” – 110 mm Flange 694 and its characteristics are exactly
203/4VX Grooved
the same, but all the components
Flange
204/4FX
204/4VX 96 4” – 110 mm Grooved 5.968 are perfectly designed to be in
204/6FX 422
4
6” – 160 mm Flange 925
contact with this type of water
204/6VX Grooved without getting damaged by this
SERIE
200 205/4FX Flange reason.
DLP 205/4VX 120 4” – 110 mm Grooved 7.460
5
205/6FX 528 6” – 160 mm Flange 1.156
205/6VX Grooved
209/6FX AA Flange
209/6VX AA 6” – 200 mm Grooved
216 13.428
9
950 2.081
209/8FX AA 8” – 200 mm Flange
209/8VX AA Grooved
210/6FX AA Flange
6” – 200 mm Grooved Max. Working pressure. 10 bar / 145 psi
210/6VX AA 240 14.920
10 Filtering surface per filter 2S" = 1492 cm2 / 231 in2
1.056
Flange
2.312 Min. working pressure. 0.8 bar / 11.6 psi
210/8FX AA 8” – 200 mm
210/8VX AA Grooved If the application is for aggressive waters, the
Max. Temperature 60º / 140º F
Drainage manifold of 3”- 90 mm grooved connection elements and / or to
combination AW AA and its characteristics are
glue. exactly the same, but all the components are pH range 4-11
Pressure manifold of 3”- 90 mm grooved connection elements and / or to perfectly designed to be in contact with this type
glue.
of water without getting damaged by this
reason.
SERIE 300
MG DISC WALL DISC
BACFLUSHING
PROCESS
400-200-130 micron 100 micron 130-100 micron Serie 300 is similar to 200, but the filters
2.8 bar 3.5 bar 2.8 bar and the valves are of 3”. The 3” valves are
Min. Backflushing
pressure
40 psi 50 psi 40 psi
able to filter more m3/h per filter.
2.5 l/s 3.1 l/s 2.5 l/s
Backflushing flow rate
per filter
39 gpm 50 gpm 39 gpm
Max. Flow
Filtering surface
130 micron N. Diameter inlet/outlet
Model Connection cm²
m3/h of filters manifold
in2
gpm
307/8FX 224 8” – 200 mm Flange 10.444 Filtering surface per filter 3"= 1492 cm2 / 231 in2
7
307/8VX 986 Grooved 1.619
Max. Working pressure. 10 bar / 145 psi
308/8FX 256 Flange 11.936 Min. working pressure. 1.5 bar / 22 psi
8 8” – 200 mm
308/8VX 1.126 Grooved 1.850
Max. Temperature 60º / 140º F
Drainage manifold of 3”-90 mm grooved connection elements and / or to glue.
pH range 4-11
The serie 300 is similar to 200, but the filters
SERIE 300 DLP
and the valves are of 3”. The 3” valves are
able to filter more m3/h per filter. AZUD HELIX AUTOMATIC DLP allows the reduction of the energetic
use of the filtration installations, increasing their performance, and
MG DISC WALL DISC demanding the minimal pressure consumptions and flow rate on each
BACFLUSHING
400-200-130-100 micron 130-100 micron backwashing, keeping the maximum efficiency in a wide filtration
PROCESS
grades range.
1.5 bar 1.3 bar
Min. Backflushing
pressure
22 psi 19 psi
Furthermore, with the patented HELIX system, the frequency and
intensity of the maintenance labours of the system are minimized.
2.5 l/s 2 l/s
Backflushing flow rate
per filter
The energetic cost is dramatically reduced per filtered m3 in the
40 gpm 32 gpm
installation, minimizing the environmental impact.
Max. Flow
N. Diameter Filtering surface
130 micron
Model of inlet/outlet Connection cm²
m3/h
filters manifold in2
gpm
Max. Flow
N. Filtering surface
130 micron Diameter inlet/outlet
Model of Connection cm²
m3/h manifold
filters in2
gpm
64 Flange 2.984
302/4FE HP 2 4" - 100 mm
282 463
96 Flange 4.476
303/4FE HP 3 4" - 100 mm
422 694
128 5.968
304/6FE HP 4 6" - 150 mm Flange
563 925
SERIE
300 160 7.460
305/6FE HP 5 6" - 150 mm Flange
HP 704 1.156
192 8.952
306/6FE HP 6 6" - 150 mm Flange
845 1.388
224 10.444
307/8FE HP 7 8" - 200 mm Flange
986 1.619
256 Flange 11.936
308/8FE HP 8 8" - 200 mm
1.126 1.850
Drainage manifold 3”- 80 mm of diameter with flange connections. Filtering surface per filter 3" = 1492 cm2 / 231 in2
Max. Flow
filtering surface
130 micron N. Diameter
Model Connection cm²
m3/h of filters inlet/outlet manifold
in2
gpm
144 8.952
4DCL3/6FX 3 Flange 6" - 160 mm
634 1.388
4DCL4/6FX 6" - 160 mm
192 11.936
4 Flange
4DCL4/8FX 845 8" - 200 mm 1.850
pH range 4-11
Drainage manifold 4”- 110 mm manufactured in grooved connection elements and / or to glue.
SERIE 4DCL DLP & 4DCL AW DLP
MG DISC WALL DISC In line equipments with groups of two independent filtering elements with 3”
BACFLUSHING valves.
400-200-130-100 micron 130-100-50-20-10-5 micron
PROCESS
Min. Backflushing
1.5 bar 1.3 bar AZUD HELIX AUTOMATIC DLP allows the reduction of the energetic use of
pressure
22 psi 19 psi the filtration installations, increasing their performance, and demanding the
5 l/s 4 l/s
minimal pressure consumptions and flow rate on each backwashing, keeping
Backflushing
flow rate per filter the maximum efficiency in a wide filtration grades range.
79 gpm 63 gpm
AZUD HELIX AUTOMATIC AW are specifically designed to
Max. Flow
N. Diameter
filtering optimize the filtration in the installations with limited salinity
130 micron surface
Model
m3/h
of Connection inlet/outlet
cm² conditions, as the exposition to the corrosive action of saline
filters manifold
gpm in2 waters of low salinity, in conditions with slight levels of saline
144 8.952
4DCL3/6FX
634
3 Flange 6" - 160 mm
1.388 concentration .
4DCL4/6FX 6" - 160 mm
192 11.936
4DCL4/8FX 845
4 Flange
8" - 200 mm 1.850 If the application is for aggressive
waters, the combination AW DLP
4DCL5/6FX 6" - 160 mm
240
1.056
5 Flange
14.920
2.313
and its characteristics are exactly
4DCL5/8FX 8" - 200 mm
the same, but all the components
4DCL6/8FX
288
6 Flange
8" - 200 mm
17.904 are perfectly designed to be in
1.267 2.775
4DCL6/10FX 10” - 250 mm contact with this type of water
4DCL7/8FX
336
8" - 200 mm
20.888 without getting damaged by this
7 Flange
4DCL7/10FX
1.478
10” - 250 mm
3.238 reason.
SERIE
4DCL 4DCL8/8FX 8" - 200 mm
384 23.872
DLP 8 Flange
1.690 3.700
4DCL8/10FX 10” - 250 mm
BACFLUSHING
SERIE 400
400-200-130 micron 100 micron 130-100 micron
PROCESS
AZUD HELIX AUTOMATIC DLP allows the reduction of the energetic use of the Min. 1.5 bar 1.3 bar
filtration installations, increasing their performance, and demanding the minimal Backflushing
pressure 22 psi 19 psi
pressure consumptions and flow rate on each backwashing, keeping the
maximum efficiency in a wide filtration grades range. Backflushing
2.5 l/s 2 l/s
flow rate per filter
40 gpm 32 gpm
Furthermore, with the patented HELIX system, the frequency and intensity of the
maintenance labours of the system are minimized.
The energetic cost is dramatically reduced per filtered m3 in the installation, PNEUMATIC CONTROL
703/3FX Flange
703/3VX 72 3” – 90 mm Grooved 4.476
3
703/4FX 317 4” – 110 mm Flange 694 DLP
703/4VX Grooved
704/4FX Flange
704/4VX 96 4” – 110 mm Grooved 5.968
4
704/6FX 422 6” – 160 mm Flange 925
704/6VX Grooved
SERIE
700 705/4FX Flange
DLP 705/4VX 120 4” – 110 mm Grooved 7.460
5
705/6FX 528 6” – 160 mm Flange 1.156 Filtering surface per filter 2" = 1492 cm2 / 231 in2
705/6VX Grooved
If the application is for saline water (SW), the combination and its
706/6FX 144 Flange 8.952
706/6VX 634
6 6” – 160 mm
Grooved 1.387 characteristics are exactly the same, but all the components are
707/6FX 168 Flange 10.444
perfectly ready to be in contact with this type of water without wearing
707/6VX 739
7 6” – 160 mm
Grooved 1.619 for this reason, without limiting in the saline concentration
708/6FX Flange
708/6VX 192 6” – 160 mm Grooved 11.936 Max. working 6 bar / 87 Min. Neumatic working pressure
8 pressure psi 6 bar
8” – 200 mm Flange 87 psi
708/8FX 845 1.850 Pneumatic Pressure
708/8VX Grooved Max. Temperature 60º / 140º F
AZUD HELIX AUTOMATIC DLP allows the reduction of the energetic use of the filtration Min. 1.5 bar 1.3 bar
Backflushing
installations, increasing their performance, and demanding the minimal pressure pressure 22 psi 19 psi
consumptions and flow rate on each backwashing, keeping the maximum efficiency in a
wide filtration grades range. Backflushing
2.5 l/s 2 l/s
flow rate per filter
40 gpm 32 gpm
Furthermore, with the patented HELIX system, the frequency and intensity of the
PNEUMATIC CONTROL
maintenance labours of the system are minimized.
The energetic cost is dramatically reduced per filtered m3 in the installation, minimizing
the environmental impact.
Max. Flow N.
Diameter Filtering surface
130 micron of
Model inlet/outlet Connection cm2
m3/h filters
manifold in²
gpm
48 2.984
702/3FX Flange
2 3” – 90 mm
702/3VX Grooved
211 463
703/3FX Flange
703/3VX 72 3” – 90 mm Grooved 4.476
3
703/4FX 317 4” – 110 mm Flange 694
703/4VX Grooved
704/4FX Flange
704/4VX 96 4” – 110 mm Grooved 5.968
4
704/6FX 422 6” – 160 mm Flange 925
704/6VX Grooved
SERIE
700 Flange
705/4FX
CL 120 4” – 110 mm Grooved 7.460
705/4VX
DLP 5
705/6FX 528 6” – 160 mm Flange 1.156
705/6VX Grooved Filtering surface per filter 2" = 1492 cm2 / 231 in2
706/6FX 144 Flange 8.952
706/6VX 634
6 6” – 160 mm
Grooved 1.387 If the application is for aggressive water, as high chlorine concentrations (CL),
the combination and its characteristics are exactly the same, but all the
707/6FX 168 Flange 10.444
707/6VX 739
7 6” – 160 mm
Grooved 1.619
components are perfectly ready to be in contact with this type of water without
wearing for this reason.
708/6FX Flange
708/6VX 192 6” – 160 mm Grooved 11.936 Max. working 6 bar / 87
8 pressure psi Min. Neumatic working pressure 6 bar
8” – 200 mm Flange 87 psi
708/8FX 845 1.850
708/8VX Grooved Max. Temperature 60º / 140º F
Max. Flow N.
Diameter Filtering surface
130 micron of
Model inlet/outlet Connection cm2
m3/h filters
manifold in²
gpm
48 2.984
702/3FX Flange
2 3” – 90 mm
702/3VX Grooved
211 463
703/3FX Flange
703/3VX 72 3” – 90 mm Grooved 4.476
3
703/4FX 317 4” – 110 mm Flange 694
703/4VX Grooved
704/4FX Flange
704/4VX 96 4” – 110 mm Grooved 5.968
4
704/6FX 422 6” – 160 mm Flange 925
704/6VX Grooved
SERIE
700 Flange
705/4FX
DW 120 4” – 110 mm Grooved 7.460
705/4VX
DLP 5
705/6FX 528 6” – 160 mm Flange 1.156
705/6VX Grooved
Filtering surface per filter 2" = 1492 cm2 / 231 in2
706/6FX 144 Flange 8.952
706/6VX 634
6 6” – 160 mm
Grooved 1.387 Especially designed to applications in which it is necessary the
707/6FX 168 Flange 10.444
validation/certification of the filter to its use in waters to human
7 6” – 160 mm
707/6VX 739 Grooved 1.619 consumption.
708/6FX Flange
708/6VX 192 6” – 160 mm Grooved 11.936 Max. working 6 bar / 87 Min. Neumatic working pressure 6 bar
8 pressure psi 87 psi
708/8FX 845 8” – 200 mm Flange 1.850
708/8VX Grooved Max. Temperature 60º / 140º F
MG DISC WALL DISC In line equipments with groups of two independent filtering elements with 3” valves.
BACFLUSHING
PROCESS
400-200-130-100 micron 130-100-50-20-10-5 micron AZUD HELIX AUTOMATIC DLP allows the reduction of the energetic use of the filtration
installations, increasing their performance, and demanding the minimal pressure
1.5 bar 1.3 bar
Min. Backflushing consumptions and flow rate on each backwashing, keeping the maximum efficiency in a
pressure
22 psi 19 psi wide filtration grades range.
5 l/s 4 l/s
Backflushing
flow rate per filter
Furthermore, with the patented HELIX system, the frequency and intensity of the
79 gpm 63 gpm maintenance labours of the system are minimized.
Max. Flow filtering
The energetic cost is dramatically reduced per filtered m3 in the installation, minimizing the
N. Diameter
Model
130 micron
of Connection inlet/outlet
Surface environmental impact.
m3/h cm²
filters manifold
gpm in2
144 8.952
803/6FX 3 Flange 6" - 160 mm PNEUMATIC CONTROL
634 1.388
804/6FX 6" - 160 mm
192 11.936
4 Flange
804/8FX 845 8" - 200 mm 1.850
In line equipments with groups of two independent filtering elements with 3” valves.
MG DISC WALL DISC
BACFLUSHING
PROCESS
AZUD HELIX AUTOMATIC DLP allows the reduction of the energetic use of the filtration
400-200-130-100 micron 130-100-50-20-10-5 micron
installations, increasing their performance, and demanding the minimal pressure
Min. Backflushing
1.5 bar 1.3 bar consumptions and flow rate on each backwashing, keeping the maximum efficiency in a
pressure wide filtration grades range.
22 psi 19 psi
Backflushing
5 l/s 4 l/s Furthermore, with the patented HELIX system, the frequency and intensity of the
flow rate per filter
79 gpm 63 gpm maintenance labours of the system are minimized.
The energetic cost is dramatically reduced per filtered m3 in the installation, minimizing the
Max. Flow
N. Diameter
filtering environmental impact.
130 micron Surface
Model of Connection inlet/outlet
m3/h cm²
filters manifold
gpm in2
144 8.952
803/6FX 3 Flange 6" - 160 mm PNEUMATIC CONTROL
634 1.388
804/6FX 6" - 160 mm
192 11.936
4 Flange
804/8FX 845 8" - 200 mm 1.850 Filtering surface per filter 4"
805/6FX 6" - 160 mm
2984 cm2 / 463 in2
240 14.920
5 Flange
1.056 2.313
805/8FX 8" - 200 mm
Equipment made by 2” SUPER Self-cleaning filters with helix system, disc filtering element 0.8 bar
Min. Backflushing pressure
and water tank (without cartridge). 11.6 psi
Max. Flow Filtering
N. Diameter 10 l
130 micron surface Backflushing
Model of inlet/outlet Connection flow rate per filter
m3/h cm² 2.64 gpm
filters manifold
gpm in2
6 bar
702/3FX AA 48 Flange 2.984 87 psi
2 3” – 90 mm Air Injection
702/3VX AA 211 Grooved 463
System 1200 l/minute
703/3FX AA Flange 317 gpm
703/3VX AA 3” – 90 mm Grooved
72 4.476
3
317 694
703/4FX AA 4” – 110 mm Flange
703/4VX AA Grooved
704/4FX AA Flange
704/4VX AA 4” – 110 mm Grooved
96 5.968
4
422 925
704/6FX AA 6” – 160 mm Flange
704/6VX AA Grooved
705/4FX AA Flange
705/4VX AA 4” – 110 mm Grooved
120 7.460 PNEUMATIC CONTROL
5
528 1.150
705/6FX AA 6” – 160 mm Flange
705/6VX AA Grooved
SERIE
706/6FX AA 144 Flange 8.952
700 6 6” – 160 mm
706/6VX AA 634 Grooved 1.387
AA
707/6FX AA 168 Flange 10.444
7 6” – 160 mm
707/6VX AA 739 Grooved 1.619
708/6FX AA Flange
708/6VX AA 6” – 200 mm Grooved
192 11.936
8
845 1.850
8” – 200 mm Flange
708/8FX AA
Grooved
AZUD HELIX AUTOMATIC AA equipments are designed to the installations where
708/8VX AA
minimize the volume of water used in the self-cleaning is a priority.
Flange
709/6FX AA
6” – 200 mm Grooved
They permit to make a whole backflushing cycle making independent the
709/6VX AA 216 13.428
950
9
2.081
backflushing system from the filtration circuit, and minimizing the volume of water
8” – 200 mm Flange
709/8FX AA
Grooved
used to the backflushing of each filter.
709/8VX AA
710/6FX AA Flange If the application is for saline water (SW), Max. Working pressure. 10 bar / 145 psi
710/6VX AA 6” – 200 mm Grooved
240
10
14.920 the combination and its characteristics are Min. working pressure. 0.8 bar / 11.6 psi
1.056 2.312
710/8FX AA 8” – 200 mm Flange exactly the same, but all the components
710/8VX AA Grooved Max. Temperature 60º / 140º F
are perfectly ready to be in contact with this
Drainage manifold of 3”- 90 mm grooved connection elements and / or to glue. type of water without wearing for this pH range 4-11
Pressure manifold of 3”- 90 mm grooved connection elements and / or to glue.
reason.