Ok as you can see from bellow figure that to reach 100G capacity we need to cut it to 4 different
wave lengths each can carry up to 25G.
You can see that we have 4 readings with mW (milliWatt) which is (0.82100 mW & 0.74000 mW
& 0.69990 mW & 0.45910 mW) for Rx
So to get that total Rx we will do the following:
Total Rx mw= 0.82100 + 0.74000 + 0.69990 + 0.45910 = 2.7 mW
Then to get value in dBm will use this equation (dBm=10*logP where P = power
in milliWatts.)
So in our case dBm = 10*log2.7= 4.31 dBm