You are on page 1of 22
MSRDC MAHARASHTRA STATE ROAD DEVELOPMENT CORPORATION CONSTRUCTION OF NAGPUR - MUMBAI SUPER COMMUNICATION EXPRESSWAY (PACKAGE - 06) FROM KM.259+900 TO KM.296+000 ON EPC MODE. STRUCTURE DRAWINGS (UTILITY DUCT) QQco INFRATECH PVT. LTD. Elvi EM ‘with NTF Ideas* EPC CONTRACTOR DESIGN CONSULTANT APCO INFRATECH PRIVATE LIMITED CIVILMANTRA INFRACON PVT. LTD. INDEX «NO. | CUSHION | STRUCTURE DRAWING NO. REVISION | REMARKS 1 1M &2M___[ UTILITY DUCT | _D1027/CIPL/STR/UD/001 R2 2 3M UTILITY DUCT | _D1027/CIPL/STR/UD/002 R2 3 4M UTILITY DUCT |_D1027/CIPL/STR/UD/003 R2 4 5M UTILITY DUCT |_D1027/CIPL/STR/UD/004 R2 5 6M UTILITY DUCT |_D1027/CIPL/STR/UD/005 R2 ore ES § 1. ALL DIENSIONS ARE iW MELMETERS UNLESS = —_ 2 Ol maTEV ONENSINS Ae 10 BE FOUND SP ils ats Se sn 2 Sr neon aes ere Se eh 5 eo super ane EG eee ee bo a ou ee ea at BE A Gi a Eueaucsey Wace Be TAKEN UP BY ENGNGEKCN Glare Stearate 2. THE STRUCTURES DESIONED FOR SBC 12/2 © Seetet ar Shem Reseect Toa nent me ee SECTION AA 8 cuude oF CONERETE~ 10. Hori » PVG Wet HOLES SPACED at 100/ce Cm cezonra and WERTICALY Sha 8 Rowe BOK WALL 1Somm ABOVE CL BEND RETURL/WG WALL ND BOX WALL 12, THE BACRFL, MATERIAL BEANO ACE BOX /RETLAN le, Sia abe Penton Pores 230 DNSTr=20T/Gow Cmo, AS PER CLAUSE 2082 OF 15, CASE STRUCTURE FOuNOKD ON EREDILE SOL AoSaFeSTeSHoN we SAL Se FOLLOWED, AS Parcine sro-2004 LAURE Re. 70" 1 AS FER I 6-207, 6 LOAN 6 ALSO aNSDERED Stim HE veo nox Ee q oe 4 Bee ise 4 Meal SRGuNo LeveL ee eee ve Pes cane man =e go wu oe sensu 8 ween BEVnawAW/ 22h — my, & ! Hie ] | 500 1, | Pie cow al es ul | al | == 1 ul . 1 oo g jae Ho. \ 7 °_suwe sie —f i. HRP gh Foownorin | EOOD Fe & — os TEAM LEADER SPB of on eae saan fuew =o (ah Cae ee ‘Eapinoers an Consuttanes Pett OA RL ‘TABLE :- 1m CUSHION S.No. |CHAINAGE] STRUCTURE | SPAN | FRL | A(m) | B(m) | a(m) | cm) | d{m) | I/cRL ante aces 1__ | 269+100 |umuTy DUCT] 1x2x2 | sa8.8a7 | 2 2 0.25 02 03 | 546.087 02 0.55 2 | 2694500 [umuty uct] _ax2x2_| 546.837 | 2 2 0.25 02 0.3 | 544.087 0.2 0.55 3 | 274+200 [umuTy Duct 1x2x2 | 545.218[ 2 2 0.25 02 03 | 542.221 0.45 08 4 | 276-400 [umuTy Duct] 1x2x2 | 554.a86[ 2 2 0.25 02 03 | 551.832 1 0.45 s__| 278+320 [unuty uct ax2x2 | 567.571] 2 2 0.25 02 0.3 | 564.755 0.27 0.62 6 | 279+000 [unity buct| 1x2x2 | 561.496| 2 2 0.25 02 03 | 558.746 02 0.55 7__| 280+785 [unuTy uct] 1x2x2 | 560.494[ 2 2 0.25 02 03 | 557.744 02 0.55 | 282+200 |unuybuct| 1xax2_| 553.664] 2 2 0.25 02 03 | 550.914 02 0.55 9 | /283+200 [unity buct| axax2 | 538.389| 2 2 0.25 02 03 | 535.639 02 0.55 10 | 286+800 [uTuTYDuCT| 1x2x2 | 555.755[_ 2 2 0.25 02 0.3 | 553.005 02 0.55 11 __|_289+365 [unity Duct 1x2x2_| s42.689| 2. 2 0.25 02 0.3 | 538.939 02 0.55 12 | 291+300 [Tuy bucT| 1xax2 | 545.613| 2 2 0.25 02 03 | 542.569 0.49 0.84 13 _ | 2924500 [uTiuTyoucT| ax2x2 | 561.956] 2 2 0.25 0.2 03 | 559.206 02 0.55 14__| 2934800 [uTuTy Duct] _1x2x2 | 578.025| 2 2 0.25 0.2 03 | 575.275 02 0.55 15 _|_294+300 [umutyDuct|_1x2x2 | 570.951] 2 2 0.25 0.2 03 | 568.201 0.2 0.55 16 | 295+615 [umuTy DUCT] 1x2x2 | 565.766] 2 2 0.25 0.2 0.3 | 563.016 0.2 0.55 Pree Ae = 2m CUSHION CRUST#CUSHION | |CRUST+CUSHION CHAINAGE| STRUCTURE | SPAN | FRL | A(m) | Bim) | a(m) | elm) | d(m) | I/CRL (Min) (Max) 2614350 [umumy buct| 1x2x2 | 536.015 |__2 2 0.25 0.3 | 532.209 1.26 161 264+100 [uuu DucT| 1x2x2_| 526.336 | 2 2 0.25 03 | 522.968 0.82 117 266+610 [umiuTy DucT| 1x2x2 | 544.957 |__2 2 0.25 03 | 501.382 1.03 1.38 271+300 |uTiuTy oucT| 1x2x2 | 543.988 | 2 2 0.25 0.3 | 540.213 1.23 1.58 272+300 |uTiuTy bucT| axax2 | 542.365 | 2 2 0.25 03 | 538.354 1.46 1.81 275+915 |uTiuTy ucT| 1x2x2 | 555.559 | 2 2 0.25 551.926 1.08 1.43 ICTION a o NNMSCEL-PKG 06 ‘harves Aasocintes architects ea) -NOIES 2 4m mg gat ounce 2 ne SRC EE oe 1 r= =e ‘aw 3: elle lo lo ef 3 |g oF sywueTRY mo Tt | Par ® all {a ' +h © q 11 . Ht Li ch e 7 ® gt te Sp fe ee SRE maeien | SET oS? lo? Le omy @. PINS Re Pet & mal RA nal ES i CUSHION) § ‘CUSHION) Eisno\| we | ver [er 3] Esa \| wa | wa | rar (e = 1 « = sae acu ae = bo 4 = mm = a a fe) = = Se ” = fexsemes ae ee iol 7 2 ee T- = = cq] bf a | | = il 5 e le e jel [1 we | 1 on — = _— = one ia = PROOF OHECKED BY ” [S| * & : Bs 5 ; bp & 7 lol es es = ST = ene pc. DE [GOOD FOR CONSTRUCTION SESE ES = Wefan ieeetbies a Tete ee heel es. SECTION A-A Shumynve’mer oF Ieee a a gnome Se ess "at Puan a ne a ‘Bis tiezaitin ows rn cae Sn Sco ona. fo@-emececeuent Sloman /ate/w/oor sect sore Dlomarsn/oyoce Set fer CUSHION FOR 3M CRUST#CUSHION —[CRUST+CUSHION S.No. |CHAINAGE| sTRUCTURE| SPAN | FRL | A(m) | B(m) | a(m) | cm) | ad(m) | /cRL (min) (max) 1_ | 2624530 [umuybuct| axax2 | 36.717 [2 2 0.25 02 03 | 531.768 24 2.75 2 | 263+300 [umiuty buct| axax2 | 535.962 | 2 2 0.25 02 0.3 | 531.648 176 2.11 3__| 265+000 |uTumty Duct] tx2x2 [532.341 | 2 2 0.25 0.2 0.3 | 527.199 2.59 2.94 4 | 2814000 Jury buct| 1x2x2 [532.341 | 2 2 0.25 02 0.3 | 555.749 18 2.15 te GOOD FOR CONSTRUCTI ee rn : seeRnre I ERE RETLAEP I e BEhT | HREM Sea se smucne en Fm i T Selle le bo parte a on SER IE ST es Sm oe 7 | DeTAL= eee @ yew 2-2 ame nS 0) egal oxma cum 200 10 Sei SPS Fee \| Rie | rie | Se | ~|= lal > [= la lee (a| «|= (ol «|= (a| «|= os CONSTRUCTION} ‘TEAM LEADER NMSCEL-PKG 06 ‘Aarves Associates Arch ‘tec Engingers and Consultante Pits. ‘e Association with T¥C ICSC ODODDP NIA AL SS sss Ts = Meese Se Team taper — bi] eae ‘05 fa Sc CUSHION FOR 4M CRUST#CUSHION | CRUST+CUSHION S.No. |CHAINAGE| STRUCTURE | SPAN | FRL | A(m) | B(m) | atm) | c{m) | d(m) | t/cRL (Min) (MAX) 1___[ 260+400 JuTuTyDuct|_tx2x2 | sa6.138| 2 2 0.25 02 0.3 | 540.768 2.82 3.17 2__| 270+690 JuTuiTy Duct] tx2x2 [| saa.901| 2 2 0.25 02 0.3 | 536.309 3.04 3.39 3 | 2734280 |umuty Duct] ax2x2 [543.717 | 2 2 0.25 02 03 | 537.881 3.29 3.64 4__| 277810 |umutybuct|_1x2x2 | 565.802 | 2 2 0.25 02 0.3 | 560.345 2.91 3.26 5 | 284600 Juriutyouct| axax2 | s36ga5 [2 2 0.25 0.2 03 [531.043 3.29 3.64 ESKED B [GOOD FOR CONSTRUCTION] ra and Consultants Pet-Ltp. imAssociation with 7VC et —s 6 dae a S e680 NMSCEL-PKG 05 ‘Associates Architect inoore and Consultants Pvt ‘im Association with TVe qu smen ‘JOP SLAB R/F PLAN wo ABABA UND NS oT SO Ue . q { NOES, SCHEDULE oF REINFORCEMENT (veaxayium 3.0m 70 Po k 46 CUSHION) pceceaueneeet | BF | Bee | wee | er Sstsemne ani ace a ANDAR VEL = weefere ee] GOOD FOR CONSTRUCT! ‘TEAM LEADER pees — {2 Fk... ees CUSHION FOR 5M CRUST+CUSHION [CRUST+CUSHION S.No, |CHAINAGE) STRUCTURE | SPAN | FRL | A(m) | Bim) | a(m) | elm) | d(m) | I/cRL (Min) (MAX) 1__| 2674600 [umuty uct] axax2 | 552.291 | 2. 2 0.25 02 03 | 544.401 4.34 4.69 2874665 |uTILiTYDUCT| 1x2x2 | 554.395 | 2 2 0.25 0.2 03 | 547.696 4.15 4.50 3 | 2901000 [unity uct] ax2x2_| 542.765 | 2 2 0.25 02 0.3 | 536.638 3.57 3.92 (00D FOR CONSTRUCTION] ‘TEAM LEADER NMSCELPKG 06 vee Associates Architects 8 and Consultants Pvt ‘Association with TVC wees eT 109 of e. yorum i i i T i i i beg! : dlollelo le ‘oP SLAB R/F PLAN (ne A, CET ON AS oT SUK FD norts: $25.58 (1X2K2)(WITH_4.01M TO} lk Sera ‘SM. CUSHION) 5 | BP ie sow NX] MaRS | wie | Bhat ic - C = | ww” | TOES = vo Teton 8S weep HLS hc 4 00/00 Tees Te ara cRAsH BARRIER Bioryepuyamio7ees SHEET» OF ¢ Blomferifsmeua/acs Sur 2 * PROOF ciyECKED BY CUSHION FOR 6M CRUST#CUSHION —[CRUST+CUSHION S.No. |CHAINAGE| STRUCTURE | SPAN | FRL | A(m) | B(m) | alm) | cfm) | d{m) | m/cRL (mane) (MAX) 1__ | 285+600 |umiutybuct|_1x2x2 | 540.787 [2 2 0.25 02 03 | 532.611 5.63 5.98 2___| 288+500 Jumiuty buct| 1x2x2 [ sas.0a6 [2 2 0.25 02 0.3 | 540.879 5.62 5.97 1 = J = (ees es ‘NOTES, oF snmrer . oom 2 mimwacre as ut esas bs 2 G. i T qi 1 : | ) Are 1 | cease eee ee ! Hol TROT Ft Je meee ree re caesar 5 olele lo oP siat (oe ne (BIEL HE FRE LAS 0M PUN) a ow ‘eor somerey je hi =| T nl i I © 06 @ OSS Le Se a oY MEW 2-2 (oawet ne ar 900) Se See =p gal (1x2xay(wirh 5.1m TO} tefaite|* “eM CUSHION) Ho] BoP acue\| BM | arene | Bas ig rales C a jf o— || - el = [= oe cafe - 7 eb gC |- |= pom]: Siam = to = atc Sao weeceeee — & aS U4 lf LJ ee” ss = ee Se

You might also like