You are on page 1of 1

Observation and Calculations:

For reading 1st and 2nd


Hot stream Flow rate=qh=1L/min=1.6667*10^-5 (m^3/s)
Cold stream Flow rate=qc=2L/min=3.3333*10^-5 (m^3/s)
For reading 3rd and 4th
Hot stream Flow rate=qh= 2L/min=3.3333*10^-5 (m^3/s)
Cold stream Flow rate=qc= 1L/min=1.6667*10^-5 (m^3/s)
Note: 1st and 3rd readings are for Co-Current flow while 2nd and 4th readings are for
Counter-Current flow.

No. THin THout TCin TCout TH(mean) TC(mean) ph (at mean pc (at mean Cph (at mean Cpc (at mean
(℃) (℃) (℃) (℃) (℃) (℃) temperature) temperature) temperature) temperature)
(kg/m^3) (kg/m^3) (kJ/kgK) (kJ/kgK)
1 61 47 24 29 54 26.5 985.69 997.05 4.18 4.18
2 61 46 24 30 53.5 27 985.69 997.05 4.18 4.18
3 61 54 22 33 57.5 27.5 985.69 995.65 4.18 4.18
4 61 55 22 32 58 27 985.69 995.65 4.18 4.18

Calculations Results summary:


∆Th ∆Tc Qh Qc ∆θin ∆θout LMTD Uh Uc Power
(K) (K) (kJ/s) (kJ/s) (K) K) (K) (kW/m^2K) (kW/m^2K) loss Efficiency
14 5 0.961395541 0.694605 37 18 26.36889 0.544171 0.393162 0.266791 72.24961
15 6 1.030066651 0.833525 31 22 26.24329 0.585831 0.474052 0.196541 80.91957
7 11 0.9613667 0.763015 39 21 29.07732 0.493469 0.391655 0.198352 79.36774
6 10 0.8240286 0.69365 29 33 30.95694 0.397292 0.334432 0.130379 84.17791