JSW Steel Ltd.

Dolvi Works
Department Kaizen No Date
OXYGEN 03-02-2020

Kaizen Theme:(Should indicate improvement/reduction of the problem) Kaizen Idea: (Solution or How to overcome the problem)
Safety improvement while operating blow down valve Platform with railing provided
Kaizen Impact Source of Kaizen
Safety DWM
Improvement Parameter UOM Before(Value) After(Value)
safety SO nos. 1.0 0.0
Before (Situation) Root Cause Analysis Countermeasure Implemented After (Situation)
NA NA
No platform with railing available Proper platform with railing
while operating blow down valve provided

Intangible gains Tangible gains:(Rs. per annum) Standardization Horizontal Deployment Opportunities
Safety improved 0 Not Applicable Yes
S.No Emp Name Emp Code Grade Organization
1 Satish Yadav 18956 L11 JSW
2 Damaji Mhatre 2052 technician Associates
Kaizen Expert Status Remarks Champion Status Remarks Kaizen Kaizen Category
Implementation
Date
GURU DUTT Pending with SHARAD Pending with 27-12-2019 A category
SINGH Kaizen Expert KUMAR Champion
MISHRA
Note:We Certify that this improvement has not been executed or registered earlier in any categories of improvement (i.e. Kaizen, QCC, QIP, DMAIC, etc.)