You are on page 1of 1

FOOTING EXCAVATION LAYOUT

NOTE:
* This structural drawing is the Sole property of
P.K.Ashwathnarayana Gupta & Asso., Hubli. It should not
be reproduced, copied or reused without the permission of
this firm in any circumstances.
A B C D E * This drawing should be read in conjunction with all
Architectural, Structural & other relevant Engg. Drawings.
45' SITE * Any Discrepencies in the drawing should be brought to
32'-6" O/O the notice of the structural engineer before starting the
31'-9" C/C execution of work.
31 2 " * All Dimension are to be read & not to be measured. All
5'-41 2" 15' 4'-9" 11'-9" 7'-101 2 "
Dimensions are in feet & inches.
C2
3'-41 2"

C1 C3

2'-9"

2'-9"
3'
General Notes:
1 1. CONCRETE GRADE USED IS M20 (1:1.5:3)
3'-3"

3'-3"
3'
C1,F1 C2,F3 C1,F1 UNLESS OTHERWISE SPECIFIED.
2'-6" 2'-6" 3'-6" 3'-6" 2'-6" 2'-6"
2. ALL STEEL EXCEPT 6MM DIA IS TMT OF GRADE
Fe 500 N/ Sqmm.
14'-9"

3. COLUMNS AND FOOTINGS ARE DESIGNED FOR


GROUND+1 FLOORS ONLY.
2'-9" 2'-9" 3'-9" 3'-9" 2'-9" 2'-9" 4. THE BUILDING IS DESIGNED AS PER IS CODES
C4 C5 C6 OF PRACTISE CONSIDERING SBC AS 20 T/M2.
3'-6"

3'-6"
3'-3"

5. LAPPING OR ANCHORAGE LENGTH FOR


2 a) BEAM AND SLAB = 60 x DIA OF THE BAR,
3'-3"
3'

3'
C1,F2 C1,F2 b) COLUMN = 50 x DIA OF THE BAR.
C2,F4
6. CLEAR COVER TO RENFORCEMENT
a) FOOTING = 50 MM, c) BEAM = 25 MM,
b) COLUMN = 40 MM, d) SLAB = 15 MM.
7. DO NOT CAST ANY R.C.C WORK UNLESS IT IS
CHECKED & CONFIRMED BY STRUCTURAL ENGNR.
22'-71 2"
56'-6" O/O

55'-9" C/C

8. DESIGN OF CENTRING, SHUTTERING, AND


CONCRETE MIX IS ENGINEER'S RESPONSIBLITY.
9. DESHUTTERING/CURING FOR RCC SLABS AS PER
IS CODES ARE
i) For Spans less than 5m- 14 days
2'-9" 2'-9" 2'-9" 2'-9" ii) For Spans more than 5m - 21days.
C7 C8 C9
80' SITE

3'

3'

3'

10)THE STRUCTURAL CONSULTANT IS NOT


3 RESPONSIBLE FOR ANY OF THE FOLL-
3'-6"

3'-6"
3'

a) Any accident due to insufficient &


C1,F2 C2,F3 C1,F2 improper shuttering & centering.
3'-101 2"
1
3'-1 2"
b) Stability of adjoining structures.
c) Settlement of bed concrete.
d) Quality of materials used for
18'-41 2"

construction purpose.
e) Cracks in walls.

C10 C11 C12


3'-3"

3'-3"
3'

4
2'-9"

2'-9"
3'

C1,F1 C2,F3 C1,F1 NO. REVISION DATE


2'-6" 2'-6" 3'-6" 3'-6" 2'-6" 2'-6"
20'-101 2 "

Project:
Proposed Residential building for
Dr.Pavan at Raichur.
Architect:

Ar Satrasala Veerandranath.
Dwg. Title:
Notes: Total number of columns 12 Nos.
1.C1 TYPE- 9" x 15",F1 TYPE 5'0"x6'0" FOOTING EXCAVATION LAYOUT
Dwg.No.: WD-02 Scale: N.T.S
COL. NOS- C1,C3,C10 & C12 - 04 nos.
Date: 11/02/2019 Dealt:Guru
2.C1 TYPE- 9" x 15",F2 TYPE 5'6"X6'6" Structural Consultant:

COL. Nos- C4,C6,C7 & C9 -04 nos. Er.Adarsh A Gupta


M.TechStr,fiv,mie,mise,mici,migs,acce(i-lm),p.e,ce
3.C2 TYPE- 9" x 18",F3 TYPE 6'0"X7'0" P.K.Ashwathnarayana Gupta & Associates,
COL. Nos- C2,C8 & C11 -03 nos. H.O:# 32 & 33, GROUND FLOOR, ANKUSH ARCADE,
BESIDE SHRINGARTALKIES,STATION ROAD,HBL-20.
4.C2 TYPE- 9" x 18",F4 TYPE 6'6"X7'6" Mob: (+91) 94485-85171.

COL. Nos- C5 -01 no. Email ID: gupt123ady@rediffmail.com

COPYRIGHT WARNING : THIS DRAWING & CONNECTED DESIGN IS THE PROPERTY OF P K ASHWATHNARYANA GUPTA & ASSOCIATES. USE OF THIS DRAWING IN PART OR WHOLE OR REUSE AT OTHER SITE WITHOUT THE WRITTEN PERMISSION IS ILLEGAL& ATTRACTS LEGAL ACTION.