METHOD OF INSTALLATION OF
NERVIA A456
FLEXIBLE CEMENTITIOUS WATERPROOFING MEMBRANE
With FIBERGLASS MESH REINFORCEMENT
5. With the second coating thoroughly dry, apply the third coating of U NERVIA
A456 Flexible Cementitious Waterproofing Membrane followed by the fourth
and final coating.
6. Waterproofed area shall be left to dry and cure for at least two (2) days prior
to floodtesting. Foot traffic is not allowed during this
TOPPING:
Except for exposed membrane, after the flood testing and upon approval and
acceptance, all waterproofed areas shall be protected with 2” concrete topping
reinforced with temperature (sloped towards the drain). These shall be done by the
General Contractor/ Owner.
GUARANTEE:
We offer a full five (5) years of guarantee for our works and materials. However,
damages caused by force majeure such as earthquake, fire, explosion, lightning,
settlement, structural failures and movement of metal work use in conjunction with
waterproofing work are not covered by this guarantee.