Panasonic {& Designing of air conditioning system is simple, no water pump, no cooling tower and no cooling/chilled water piping Simple control system, built in controls for VRF outdoor unit plus field installed LMCP for AHU/PAU Integrated package with VRF system Easy installation and maintenance Simple cable and refrigerant pipe connection Max 168kW (60HP) cooling capacity available for each AHU/PAU Built-in back-up, interlock and heat pump operation Long pipe run available for greater design flexibility Excellent full load COP for VRF outdoor unit (10HP) is 3.6, 50% COP is 4.3 Custom design of AHU/PAU arrangement to improve IAQ Flexible Design Exhaust Air Fan Heat wheel or heat pipe VRF AHU/PAU: EEY Control Unit Humidifier (Option) Variable refrigerant flow outdoor unit g Supply Air, Return Air Excellent Energy Saving cop “| IB) VRF outdoor (10HP) gj Outdoor with 2 scroll compressor (10HP) 40 3.0 20 10 00 . 100% Part Load (50%) Simple Installation VRFAHU/PAU system Chiller with AHU system VRF Chiller with AHU/PAU Simple design Easy installation * Easy maintenance Low running cost System integration Better Fresh Air Treatment VRE PAU - Up to 6,000 d's or even more - Large cooling capacity (up to 60HP) - Large external static pressure provided (up to 1,800Pa) __- Lots of IAQ options (eg. dehumidifier, UV light, PCO, heat pipe or heat wheel) ‘Traditional VRF system for Fresh ait - Small air flow rate (Max. 1800 /s) - Small cooling capacity (Max. 20HP) - Limited external static pressure (Max. 150Pa) - No space to install [AQ components Comfort Temperature Control + Preventive of temperature hunting vere ne sopysngnneesmta suspen west Seon coe PAPAS — tine With VED compressor With scroll compressor Interlock an Fun: Interlock function - When AHU started operation, it activates PAU to run automatically. sooo AHU“ON" PAU“ON" Automatic mode ‘Standby function - If the duty AHU have fault, the standby AHU will be cut-in automatically in 30 seconds ease Alarm occured Unit “ON” (Duty unit) (Standby unit) Duty & standby mode Control Systems AHU/PAU Timer wired remote controller Function ON/OFF Mode setting ‘Temperature setting (AHU only) Weekly program System Controller Individual control is possible for max. 30 groups, 30 indoor units Control of 30 AHUs / PAUs divided into 4 zones. (One zone can have up to 16 groups, and one group can have up to 8 units) Control is possible for ON/OFF, operation mode, operation monitoring, alarm monitoring, remote controller local operation prohibition, etc... Serial Interface for LonWorks Network This interface is a communication converter for connecting LonWorks to the control network. * From the host connected to LonWorks, basic settings of status ~ monitoring is possible for up to 30 nos. of AHU/PAU, LonWorks Interface ™ > AHU/PAU Interface with BMS LonWorks Interface Systerh Controller ‘LonWorks Center Control (Max. 64n0s AHU/PAU) ‘Communication Line Device (Field Supply) System Overview AHL kit controller box (with control PCB) : AHU unit (Field supplied) Remote controller for AHU kit (Option accessory) Outdoor unit : Gas piping (Field supplied) Liquid piping (Field supplied) Electronic expansion valve + Thetmistor for Gas pipe ‘Thermistor for Liquid pipe ‘Thermistor for Suction air : Thermistor for Discharge air nom mommuaED> Refri Level difference between PAU/AHU & outdoor unit 50m (outdoor unit above) 40m, (outdoor unit below) Equivalent tubing length available up to 120m VRF Outdoor Unit Performance Data Ponecamcins So — Sf ms = os JOHP: U-IOMELH7 frre Aezebteeret cl campeon 2 Fone ates pete 704 ab a Bossi Ss i] 8 Sale 7 svete s : Av dage ceca npr A894 Dnglloen hole pe. ~T pte ion soll et © reste en ilies a EEE ethan pn te Terie 6 7 18-20HP: U-ISMEIH8 igs irda cial coroner U-20ME1H8 - os > © olelee :Seeeeerigee (© 730 (mellem hele ich Brute oo : = " Seataset 1540 - veo } VRF AHU/ PAU. io AHU Performance Data Senn Oey Cr ‘AI-I1TOH-I050W ‘U-1OMELHT 149) se | 985 | 1595 | 25/55 | 13 8 ‘Al-14509T1350W ‘U-20MELLIS 290 | 144s | 1290) 595 | 25/58 | 15 56 ‘AL-IT7OH-1650W| UEIGMEIIIS + U-LMMEIN® | 447 | 1748 | 1595 | 1595 | 25/55 | 13 5 ‘AL-ITTOM19s0W| _ U20MEIH6x2 592, [ime | 1990 | 1990 | s/s) 3 us "Al-19301/-2250W |U-IBMEIHS+U-I6MEIH8x2) 745 | 1900 | 2005 | 2205 | 25/55 | 13 10 ‘ALz2s0H2250W| _ U20METH®x3 as4 | 2205. | 2208) 2205 | 2s/ss | 3 168 PAU Performance Data ST eS ee Ts Total Ses - PAU Model No en en mee tort SS Pee ie us Pa Po: Exon) vam op fm tim ap || [aicirenosow| CiowEInR UME | so [re [oes | iss foam | is | as | [aicor.nsow Meine UieEie2| 250 [wo [aw | iss [ave [as [ae _| Remarks 1 Height doesnot include the unit base 100mm* 2 Standard lengh include coil and fan. External mounted Pre Filter is Somm** Specifications are subjected to change without prior noice. Welcome Air-Tech (Malaysia) Sdn Bhd Welcome Air-Tech Sales & Services Sdn Bhd Septet eee Pe Email: eabstesivrsiolso.somny Website vnnsalcenchyo.com my cemmevimsmnsaniat Cte he CES

You might also like