You are on page 1of 117

HDR-FX7/FX7E RMT-831

Ver. 1.4 2008.06 SECTION 6 ADJ


Revision History ADJUSTMENTS

Link
Before starting adjustments VIDEO SECTION ADJUSTMENTS
Adjusting items when replacing main parts and boards PREPARATIONS BEFORE ADJUSTMENTS

List of service tools SYSTEM CONTROL SYSTEM ADJUSTMENTS

SERVO AND RF SYSTEM ADJUSTMENTS


CAMERA SECTION ADJUSTMENTS
VIDEO SYSTEM ADJUSTMENTS
PREPARATIONS BEFORE ADJUSTMENTS
AUDIO SYSTEM ADJUSTMENTS
INITIALIZATION OF EVR DATA

CAMERA SYSTEM ADJUSTMENTS SERVICE MODE


ELECTRONIC VIEWFINDER SYSTEM ADJUSTMENT REMOTE COMMANDER (RM-95)
ADJUSTMENTS
ADJUSTMENT REMOTE COMMANDER
LCD SYSTEM ADJUSTMENTS (NEW LANC JIG)

DATA PROCESS
MECHANISM SECTION ADJUSTMENTS SERVICE MODE
HOW TO ENTER RECORD MODE WITHOUT
CASSETTE

HOW TO ENTER PLAYBACK MODE WITHOUT


CASSETTE

TAPE PATH ADJUSTMENT

NTSC MODEL: HDR-FX7


PAL MODEL: HDR-FX7E

2008F0500-1
HDR-FX7/FX7E_ADJ © 2008.6
9-852-154-54 Sony EMCS Co. Published by Kohda TEC
Ver. 1.4 2008.06

TABLE OF CONTENTS
Section Title Page
6. ADJUSTMENTS
1. Before Starting Adjustments ··········································· 6-1
1-1. Adjusting Items when Replacing Main Parts and
Boards ·············································································· 6-2
1-2. List of Service Tools ························································ 6-4
6-1. Camera Section Adjustments ··········································· 6-5
1-1. Preparations before Adjustments (CAMERA Section) ··· 6-5
1-2. Initialization of EVR Data ··············································· 6-7
1-3. Camera System Adjustments ········································· 6-32
1-4. Electronic Viewfinder System Adjustments ·················· 6-77
1-5. LCD System Adjustments ············································· 6-82
6-2. Mechanism Section Adjustments ·································· 6-86
2-1. How To Enter Record Mode Without Cassette ·············· 6-86
2-2. How To Enter Playback Mode Without Cassette ·········· 6-86
2-3. Tape Path Adjustment ···················································· 6-86
6-3. Video Section Adjustments ··········································· 6-87
3-1. Preparations Before Adjustments ·································· 6-87
3-2. System Control System Adjustments ···························· 6-89
3-3. Servo and RF System Adjustments ······························· 6-91
3-4. Video System Adjustments ············································ 6-94
3-5. Audio System Adjustments ··········································· 6-99
6-4. Service Mode ······························································· 6-100
4-1. Adjustment Remote Commander (RM-95) ················· 6-100
4-2. Adjustment Remote Commander (New Lanc Jig) ······ 6-101
4-3. Data Process ································································ 6-102
4-4. Service Mode ······························································· 6-103

* The camera color reproduction frame is shown on page


6-111 to 114.

HDR-FX7/FX7E_ADJ
—2—
SECTION 6
ADJUSTMENTS

1. Before starting adjustments

EVR Data Re-writing Procedure When Replacing Board


The data that is stored in the repair board, is not necessarily correct.
Perform either procedure 1 or procedure 2 or procedure 3 when replacing board.

Procedure 1
Save the EVR data of the machine in which a board is going to be replaced. Download the saved data after a
board is replaced.
(Machine before starting repair) PC PC (Machine after a board is replaced)

Save the EVR data Download the saved


to a personal computer. data to a machine.

Procedure 2
Remove the EEPROM from the board of the machine that is going to be repaired. Install the removed
EEPROM to the replaced board.
Remove the EEPROM and install it.

(Former board) (New board)

Procedure 3
When the data cannot be saved due to defective EEPROM, or when the EEPROM cannot be removed or
installed, save the data from the same model of the same destination, and download it.
(Machine to be repaired) (Machine to be repaired)
PC

Download the data.

Save the data.

(The same model of the same destination)

After the EVR data is saved and downloaded, check the


respective items of the EVR data.
(Refer to page 6-3 for the items to be checked)

HDR-FX7/FX7E_ADJ
6-1
1-1. Adjusting items when replacing main par ts and boar ds
• Adjusting items when replacing main par ts
When replacing main parts, adjust the items indicated by z in the following table.
Note 1: When replacing the drum assy or the mechanism deck, reset the data of page: 7, address: A8 to AB to “00”. (Refer to “Record of
Use check” of “6-4. SERVICE MODE”)
Replaced part
Block replacement Mounted part replacement

(Base band signal process, etc.)


(Drum assembly) (Note 1)

(Timing generator (EVF))


PRISM assy (Inclding EE-006 board and CMOS imager)

(Component out AMP)


(PITCH, YAW sensor)

(CDS, A/D converter)

(DV signal process)

(Back light (EVF))


(REC/PB AMP)
(LCD panel)

(LCD panel)

(LCD drive)
(EVF drive)
(Back light)

(Video out)
(Oscillator)
Adjustment Section Adjustment

TT-003 board IC1201, 1203


Mechanism deck MD block
JJ-004 board SE8001, 8002
Mechanism deck (Note 1)
Mechanism deck M901

NN-003 board IC5202


OO-003 board IC6601
OO-003 board IC6602
TT-003 board IC1801
TT-003 board IC2802
TT-003 board IC3001
TT-003 board IC2001

UU-003 board D8601


PP-003 board IC9002
TT-003 board X1401
LCD block LCD901

EVF block LCD902


LCD block D901
Lens device

Initialization of Initialization of A, B, D, 1A, 1B page data


EVR data Initialization of 8, 9, C, 13, 18, 1C, 1D page data
Initialization of camera control page data
Initialization of 7C, 7E, 7F page data
Camera Origin oscillation check z
PSD sensor gradient adj. z
HALL adj. z
MR adj. z
Differential gain adj. z z
Flange back adj. z z
Optical axis adj. z z
Linearity adj. z z
F No. & ND light quality standard data input z
Linear matrix adj. z z
Auto white balance standard data input z z
LV standard data input z z
Auto white balance adj. z z
Color reproduction adj. z z
MAX GAIN adj. z z
White defect adj. z
Black defect adj. z z
Angular velocity sensor sensitivity adj. z z
EVF VCO adj. z z
Back Light adj. z z
PSIG level adj. z
V-COM level adj. z
RGB AMP adj. z
Contrast adj. z z
White balance adj. z z z
LCD LCD automatic adj. z z
V-COM adj. z z
Transmissive mode white balance adj. z z z
Reflective mode white balance adj. z z
Sample hold phase adj. z z
Mechanism Tape path adj. z z z
System control Node uniqe ID No. input
Servo, RF CAP FG duty adj. z z
Switching position adj. z z z
Error rate check z z z z z
Video S VIDEO OUT Y level adj. z z
S VIDEO OUT chroma level adj. z z
COMPONENT OUT Y level adj. z z
COMPONENT OUT Pr level adj. z z
COMPONENT OUT Pb level adj. z z

Table 6-1-1 (1)

HDR-FX7/FX7E_ADJ
6-2
• Adjusting items when replacing a boar d or EEPROM
When replacing a board or EEPROM, adjust the items indicated by z in the following table.
Replaced part Note 2: When the repair is finished,
confirm the following items.
1. Shoot the all black subject (Attach
the lens cap and shoot), and con-
firm that a vertical line is not dis-
played in the center of the screen,
and that there is no difference in
left-right brightness level of the
screen.

(COMPLETE)
(COMPLETE)
(COMPLETE)
(COMPLETE)
(COMPLETE)
(COMPLETE)
(EEPROM)
(EEPROM)
2. Shoot a subject of low light, and
confirm that a vertical line is not
displayed in the center of the
Adjustment Section Adjustment
screen, and that there is no differ-
ence in left-right brightness level
of the screen.

RadarW
TT-003 board IC3805
TT-003 board IC4202
3. Shoot a subject of normal light, and
confirm that a vertical line is not

NN-003 board
OO-003 board
UU-003 board
TT-003 board
displayed in the center of the

PP-003 board
JJ-004 board

Supporting
screen, and that there is no differ-
ence in left-right brightness level
of the screen.
Initialization of Initialization of A, B, D, 1A, 1B page data z z When the above symptom occurs,
EVR data Initialization of 8, 9, C, 13, 18, 1C, 1D page data z perform the whole process of
Initialization of camera control page data z z
“Differencal Gain Adjustment”.
Initialization of 7C, 7E, 7F page data z z
Camera Origin oscillation check z
PSD sensor gradient adj. z z z Note 3: IC2402, IC3804 (Flash
HALL adj. z z z memory) on the TT-003
MR adj. z z z board cannot be replaced.
Differential gain adj. z z z
Flange back adj. z z z
Optical axis adj. z z
Linearity adj. z z
F No. & ND light quality standard data input z z z
Linear matrix adj. z z z
Auto white balance standard data input z z z
LV standard data input z z z
Auto white balance adj. z z z
Color reproduction adj. z z z
MAX GAIN adj. z z z
White defect adj. z z z
Black defect adj. z z z
Angular velocity sensor sensitivity adj. z z z
EVF VCO adj. z z
Back Light adj. z z z
PSIG level adj. z z
V-COM level adj. z z
RGB AMP adj. z z
Contrast adj. z z
White balance adj. z z z
LCD LCD automatic adj. z z z
V-COM adj. z z
Transmissive mode white balance adj. z z
Reflective mode white balance adj. z z z
Sample hold phase adj. z z
Mechanism Tape path adj.
System control Node uniqe ID No. input z
Servo, RF CAP FG duty adj. z z
Switching position adj. z z
Error rate check z z z
Video S VIDEO OUT Y level adj. z
S VIDEO OUT chroma level adj. z
COMPONENT OUT Y level adj. z
COMPONENT OUT Pr level adj. z
COMPONENT OUT Pb level adj. z

Table 6-1-1 (2)

HDR-FX7/FX7E_ADJ
6-3
1-2. List of ser vice tools
• Oscilloscope • Color monitor • Vectorscope
• Digital voltmeter • Frequency counter • Audio level meter
• Calculating machine capable of calculating hexadecimal numbers

J-1 J-2 J-3


Adjustment remote Adjustment remote
commander commander LANC cable
(RM-95) (NEW LANC JIG) J-6082-442-A
J-6082-053-B J-6082-565-A

J-4 J-5 J-6

Small pattern box Color bar chart Clear chart


PTB-1450 For PTB-1450: For PTB-1450:
J-6082-557-A J-6082-559-A J-6082-560-A

J-7 J-8 J-9

Flange back
Minipattern box adjustment jig Siemens star chart
J-6082-353-B J-6082-563-A J-6080-875-A

J-10 J-11 J-12


ND filter 1.0
J-6080-808-A
Filter for color
temperature correction ND filter 0.4 Camera table
(C14) J-6080-806-A J-6082-384-A
J-6080-058-A ND filter 0.1
J-6080-807-A

J-13 J-14 J-15


Audio operation check

Tracking standard SW/OL standard for NTSC (XH5-3)


(XH2-1) (XH2-3) 8-967-997-51
8-967-997-01 8-967-997-11
for PAL (XH5-3P)
8-967-997-55

J-16 J-17 J-18


System operation check

for NTSC (XH5-5) CPC-7 jig


8-967-997-61 AC power adaptor
J-6082-382-A
AC-L15A
for PAL (XH5-5P) 1-479-283-13
8-967-997-66

Fig. 6-1-1

HDR-FX7/FX7E_ADJ
6-4
6-1. CAMERA SECTION ADJUSTMENTS

1-1. PREPARATIONS BEFORE ADJUSTMENTS


(CAMERA SECTION)

1-1-1. Preparations
Note: Before perform the adjustment, check that the data of page: L = 40 cm (PTB-1450)
0, address: 10 is “00”.
If not, select page: 0, address: 10, and set data “00”. Pattern box
Front of the lens

1) Connect the equipment for adjustments according to Fig. 6-1-3. L Camera

Fig. 6-1-2

Adjustment remote
commander
(NEW LANC JIG)
NEW LANC JIG
(J-6082-565-A)
LANC cable
(J-6082-442-A)
TT-003 board

(RM-95)
LANC jack RM-95
16 (J-6082-053-B)

CN1014 1
S Video
(Black)

Color monitor
Video Vectorscope
(Yellow) Terminated
75 Ω

Audio L
(White)

16
Audio R
CPC-7 jig
DC IN jack (Red)
(J-6082-382-A) 1
A/V jack

AC IN

EVF system adjustment AC adaptor


AC-L15A
(1-479-283-13)

Fig. 6-1-3

HDR-FX7/FX7E_ADJ
6-5
1-1-2. Precaution
1. Setting the Switc h
Unless otherwise specified, set the switches as follows and perform adjustments without loading cassette.

1. POWER switch ...................................................... CAMERA 7. AT IRIS LMT (MENU setting) ....................................... F11
2. FOUCS switch ...................................................... MANUAL 8. BACK LIGHT (MENU setting) .................................... OFF
3. ND FILTER switch ............................................... MANUAL 9. D.EXTENDER (MENU setting) ................................... OFF
4. AUTO LOCK switch ....................................... AUTO LOCK 10. STEADYSHOT (MENU setting) ................................... OFF
5. AE SHIFT (MENU setting) ................................................. 0 11. REC FORMAT (MENU setting) ................................... 1080i
6. AGC LIMIT (MENU setting) ........................................ OFF

2. Order of Adjustments
Basically carry out adjustments in the order given.

Color bar c hart (Color reproduction adjustment frame)


H
Electronic beam scanning frame
Yellow

Magenta
White
Cyan

C=D=0
Green

C D
Red
Blue

Magenta
Yellow

Green
White
Cyan

Blue
Red
CRT picture frame

V
A B A=B B A
Fig. b (monitor TV picture)
Enlargement
Fig. a
(VIDEO terminal of A/V jack
output waveform)
Difference in level

Adjust the camera zoom and direction to


B A obtain the output waveform shown in Fig. a and
the monitor TV display shown in Fig. b.

Fig. 6-1-4

3. Subjects
1) Color bar chart (Color reproduction adjustment frame)
When performing adjustments using the color bar chart, ad-
just the picture frame as shown in Fig. 6-1-4. (Color reproduc-
tion adjustment frame)
2) Clear chart (Color reproduction adjustment frame)
White
Remove the color bar chart from the pattern box and insert a
841 mm
clear chart in its place. (Do not perform zoom operations during
this time) Black
3) Chart for flange back adjustment
Join together a piece of white A0 size paper (1189 mm × 841
mm) and a piece of black paper to make the chart shown in
Fig. 6-1-5. 1189 mm

Note: Use a non-reflecting and non-glazing vellum paper. The Fig. 6-1-5
size must be A0 or larger and the joint between the white
and black paper must not have any undulations.

HDR-FX7/FX7E_ADJ
6-6
1-2. INITIALIZATION OF EVR DATA 2. Modification of A, B, D, 1A, 1B Page Data
Note 1: Pages used for the EVR consists of 39 pages. There are If the A, B, D, 1A, 1B page data has been initialized, change the
8, 9, A, B, C, D, 13, 18, 1A, 1B, 1C, 1D, 6D, 6E, 6F, 7B, data of the “Fixed data-2” address shown in the following table by
7C, 7E, 7F, 8D, 8E, 8F, 9D, 9E, 9F, AD, AE, AF, BE, BF, manual input.
C2, C3, C4, C5, C6, CC, CD, CE, CF pages.
Note 2: If 2-digit page is selected, set higher-order digit to page: Modifying Method:
0, address: 10 as data, and then select lower-order digit 1) Before changing the data, select page: 0, address: 01, and set
by a usual method. data: 01.
e.g.: Set data: 06 to page: 0, address: 10, and then select 2) If modification of data on pages A, B, D, set data: 00 to page:
page: D. Thus, the page 6D can be selected. 0, address: 10, and then select pages A, B, D.
3) If modification of data on pages 1A, 1B, set data: 01 to page:
1-2-1. Initialization of A, B, D, 1A, 1B Page Data 0, address: 10, and then select pages A, B.
Note: Check that the data of page: 0, address: 10 is “00”. After the modification of data finished, return the data on page:
0, address: 10 to “00”.
1. Initializing of A, B, D, 1A, 1B Page Data 4) New data for changing are not shown in the tables because
Note: If the A, B, D, 1A, 1B page data has been initialized, the they are different in destination. When changing the data, copy
following adjustments need to be performed again. the data built in the same model.
1) Modification of A, B, D, 1A, 1B page data Note 1: If copy the data built in the different model, the
camcorder may not operate.
Adjustment Page A 5) When changing the data, press the PAUSE (Write) button of
Adjustment Address 10 to FF the adjustment remote commander each time when setting new
Adjustment Page B data to write the data in the non-volatile memory.
6) Check that the data of adjustment addresses is the initial value.
Adjustment Address 00 to FF
If not, change the data to the initial value.
Adjustment Page D
Adjustment Address 10 to FF Processing after Completing Modification A, B, D, 1A, 1B
page data:
Adjustment Page 1A
Adjustment Address 00 to FF Order Page Address Data Procedure
Adjustment Page 1B 1 0 10 00
Adjustment Address 00 to FF 2 2 00 29
3 2 01 29 Press PAUSE (Write) button.
Initializing method: Note 2: If following symptoms occur after completing of the
“Modification A, B, D, 1A, 1B page data”, check that
Order Page Address Data Procedure
the data of the “Fixed data-2” address of A, B, D, 1A, 1B
1 0 01 01 page are same as those of same model of same destina-
2 0 10 00 tion.
1) The power is shut off so that unit cannot operate.
Set the following data
3 7 04 00: NTSC model
01: PAL model
Set the following data
20: Initializing A page
21: Initializing B page
22: Initializing D page
23: Initializing 1A page
4 7 01 24: Initializing 1B page
25: Initializing A and 1A
page
26: Initializing B and 1B
page
28: Initializing A, B, D, 1A
and 1B page
5 7 00 01 Press PAUSE (Write) button.

6 7 02 Check the data changes to


“01”.

7 Perform “Modification of A,
B, D, 1A, 1B Page Data”

HDR-FX7/FX7E_ADJ
6-7
Ver. 1.4 2008.06

3. A Page table 5. D Page table


Note 1: Check that the data of page: 0, address: 10 is“00”. Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Fixed data-1: Initialized data. (Refer to“1. Initializing the Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
A, B, D, 1A, 1B Page Data”) the A, B, D, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to“2. Modification Fixed data-2: Modified data. (Refer to “2. Modification
of A, B, D, 1A, 1B Page Data”) of A, B, D, 1A, 1B Page Data”)

Initial value Initial value


Address Remark Address Remark
NTSC PAL NTSC PAL
10 00 00 Test mode 10 to 15 Fixed data-1 (Initialized data)
11 to 17 Fixed data-1 (Initialized data) 16 Fixed data-2
18 Fixed data-2 17 to 4B Fixed data-1 (Initialized data)
19 to 2E Fixed data-1 (Initialized data) 4C Fixed data-2
2F Fixed data-2 4D to 56 Fixed data-1 (Initialized data)
30 Fixed data-1 (Initialized data) 57 Fixed data-2
31 Fixed data-2 58 to 79 Fixed data-1 (Initialized data)
32 to EF Fixed data-1 (Initialized data) 7A Fixed data-2
F0 7B to FF Fixed data-1 (Initialized data)
F1
Fixed data-2
F2 6. 1A Page table
F3 Note 1: If reading/writing data on pages 1A, set data: 01 to page:
0, address: 10, and then select pages: A. By this data set-
F4 to FF Fixed data-1 (Initialized data) ting, the pages 1A can be selected.
After the data reading/writing finished, return the data
4. B Page table on page: 0, address: 10 to “00”.
Note 1: Check that the data of page: 0, address: 10 is “00”. Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing the A, B, D, 1A, 1B Page Data”)
the A, B, D, 1A, 1B Page Data”) Fixed data-2: Modified data. (Refer to “2. Modification
Fixed data-2: Modified data. (Refer to “2. Modification of A, B, D, 1A, 1B Page Data”)
of A, B, D, 1A, 1B Page Data”) Initial value
Address Remark
Initial value NTSC PAL
Address Remark
NTSC PAL 00 to 5E Fixed data-1 (Initialized data)
00 to FF Fixed data-1 (Initialized data) 5F Fixed data-2
60 to FF Fixed data-1 (Initialized data)

7. 1B Page table
Note 1: If reading/writing data on pages 1B, set data: 01 to page:
0, address: 10, and then select pages: B. By this data set-
ting, the pages 1B can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the A, B, D, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, B, D, 1A, 1B Page Data”)

Initial value
Address Remark
NTSC PAL
00 to FF Fixed data-1 (Initialized data)

HDR-FX7/FX7E_ADJ
6-8
1-2-2. Initialization of 8, 9, C, 13, 18, 1C, 1D Page Data 2. Modification of 8, 9, C, 13, 18, 1C, 1D Page Data
If the 8, 9, C, 13, 18, 1C, 1D page data has been initialized, change
1. Initializing of 8, 9, C, 13, 18, 1C, 1D Page Data the data of the “Fixed data-2” address shown in the following table
Note 1: If “Initialization of Pages 8, 9, C, 13, 18, 1C, 1D” is ex- by manual input.
ecuted, all data on pages 8, 9, C, 13, 18, 1C, 1D are ini-
tialized. (Only an individual page cannot be initialized) Processing bef ore Modification 8, 9, C, 13, 18, 1C, 1D
Note 2: If the 8, 9, C, 13, 18, 1C, 1D page data has been initial- page data:
ized, the following adjustments need to be performed
Order Page Address Data Procedure
again.
1) Modification of 8, 9, C, 13, 18, 1C, 1D page data 1 0 01 01
2) Electronic viewfinder system adjustments (if all ar- 2 0 10 00
eas were initialized)
3 3 71 01 Press PAUSE (Write) button.
3) LCD system adjustments (if all areas were initial-
ized)
4) Node unique ID No. input (if all areas were initial- Modifying Method:
ized) 1) If modification of data on pages 8, 9, C, set data: 00 to page: 0,
5) Servo, RF system adjustments (if all areas were ini- address: 10, and then select pages 8, 9, C.
tialized) 2) If modification of data on pages 13, 18, 1C, 1D, set data: 01
6) Video system adjustments (if all areas were initial- to page: 0, address: 10, and then select pages 3, 8, C, D.
ized) After the modification of data finished, return the data on page:
0, address: 10 to “00”.
Adjustment Page 8
3) New data for changing are not shown in the tables because
Adjustment Address 00 to FF they are different in destination. When changing the data, copy
Adjustment Page 9 the data built in the same model.
Note: If copy the data built in the different model, the
Adjustment Address 00 to FF
camcorder may not operate.
Adjustment Page C 4) When changing the data, press the PAUSE (Write) button of
Adjustment Address 10 to FF the adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Adjustment Page 13
5) If all areas were initialized, check that the data at the addresses
Adjustment Address 00 to FF for adjustment are initial values (adjustment initial values)
Adjustment Page 18 listed in the table.
Adjustment Address 00 to FF If different, change them to the adjustment initial values.

Adjustment Page 1C Processing after Completing Modif ication 8, 9, C, 13, 18, 1C, 1D
Adjustment Address 00 to FF page data:
Adjustment Page 1D Order Page Address Data Procedure
Adjustment Address 00 to FF 1 0 01 01
2 0 10 00
Initializing method: 3 3 70 10 Press PAUSE (Write) button.
Order Page Address Data Procedure Check the data changes to
4 3 70
1 0 01 01 “11”.
2 0 10 00 5 2 00 29
Set the following data, and 6 2 01 29 Press PAUSE (Write) button.
press PAUSE (Write) button.
(Note 3)
3 3 81 00: Initializing all areas
01: Initializing other than
adjustment address
4 3 80 0C Press PAUSE (Write) button.

5 3 80 Check the data changes to


“1C”.
Perform “Modification of 8,
6 9, C, 13, 18, 1C, 1D Page
Data”
Note 3: If other than adjustment address was initialized, the ad-
justed data is not initialized.

HDR-FX7/FX7E_ADJ
6-9
3. 8 Page table
Note 1: Check that the data of page: 0, address: 10 is“00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, 9, C, 13, 18, 1C, 1D Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, 9, C, 13, 18, 1C, 1D Page Data”)

Initial value
Address Remark
NTSC PAL
00 to 92 Fixed data-1 (Initialized data)
93
Fixed data-2
94
95 Fixed data-1 (Initialized data)
96
97 Fixed data-2
98
99 to A0 Fixed data-1 (Initialized data)
A1
A2
Fixed data-2
A3
A4
A5, A6 Fixed data-1 (Initialized data)
A7 Fixed data-2
A8 to AE Fixed data-1 (Initialized data)
AF
Fixed data-2
B0
B1 Fixed data-1 (Initialized data)
B2
Fixed data-2
B3
B4 Fixed data-1 (Initialized data)
B5
B6 Fixed data-2
B7
B8 to C2 Fixed data-1 (Initialized data)
C3 Fixed data-2
C4 to CA Fixed data-1 (Initialized data)
CB Fixed data-2
CC to E7 Fixed data-1 (Initialized data)
E8 Fixed data-2
E9 to FF Fixed data-1 (Initialized data)

4. 9 Page table
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, 9, C, 13, 18, 1C, 1D Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, 9, C, 13, 18, 1C, 1D Page Data”)

Initial value
Address Remark
NTSC PAL
00 to FF Fixed data-1 (Initialized data)

HDR-FX7/FX7E_ADJ
6-10
Ver. 1.4 2008.06

5. C Page table Initial value


Note 1: Check that the data of page: 0, address: 10 is “00”. Address Remark
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing NTSC PAL
the 8, C, 13, 18, 1C Page Data”) 72 to 75 Fixed data-1 (Initialized data)
Fixed data-2: Modified data. (Refer to “2. Modification 76 5C 5C LCD automatic adj. (Contrast)
of 8, C, 13, 18, 1C Page Data”)
77 38 38 Contrast adj. (EVF)
Initial value 78 to 84 Fixed data-1 (Initialized data)
Address Remark
NTSC PAL Fixed data-1 (NTSC)/
85 − 70
10 EE EE S VIDEO OUT Y level adj. (PAL)
11 00 00
Switching position adj. 86 − 8A Fixed data-1 (NTSC)/
12 00 00
S VIDEO OUT chroma level adj.
13 00 00
87 − 61 (PAL)
14, 15 Fixed data-1 (Initialized data)
16 E0 E0 CAP FG duty adj. 88 to 92 Fixed data-1 (Initialized data)
17 to 24 Fixed data-1 (Initialized data) 93 79 79 COMPONENT OUT Y level adj.
S VIDEO OUT Y level adj. (NTSC)/ 94 31 31 COMPONENT OUT Pb level adj.
25 70 −
Fixed data-1 (PAL) 95 32 32 COMPONENT OUT Pr level adj.
26 8A − S VIDEO OUT chroma level adj. 96 to F3 Fixed data-1 (Initialized data)
27 61 − (NTSC)/Fixed data-1 (PAL) F4 00 00
28 to 31 Fixed data-1 (Initialized data) F5 00 00
32 4D 4D F6 00 00
Back light adj. (EVF)
33 98 98 F7 00 00
34 80 80 F8 00 00
VCO adj. (EVF) Emergence memory address
35 80 80 F9 00 00
(Mechanism section)
36 29 29 V-COM level adj. (EVF) FA 00 00
37 B1 B1 RGB AMP adj. (EVF) FB 00 00
38 Fixed data-1 (Initialized data) FC 00 00
39 4E 4E PSIG level adj. (EVF) FD 00 00
3A 80 80 FE 00 00
White balance adj. (EVF)
3B 80 80 FF 00 00
3C 38 38 Contrast adj. (EVF)
3D to 41 Fixed data-1 (Initialized data)
42 Fixed data-2
43, 44 Fixed data-1 (Initialized data)
45 8C 8C
LCD automatic adj. (VCO)
46 AA AA
47 BC BC V-COM adj. (LCD)
48 to 4A Fixed data-1 (Initialized data)
4B 79 79 Transmissive mode white balance adj.
4C 7D 7D (LCD)
4D 5C 5C LCD automatic adj. (Contrast)
4E to 51 Fixed data-1 (Initialized data)
52 Fixed data-2
53 Fixed data-1 (Initialized data)
54 9F 9F Sample hold phase adj. (LCD)
55 to 6D Fixed data-1 (Initialized data)
6E
Fixed data-2
6F
70 8E 8E Reflective mode white balance adj.
71 87 87 (LCD)

HDR-FX7/FX7E_ADJ
6-11
Ver. 1.4 2008.06

6. 13 Page table 8. 1C Page table


Note 1: If reading/writing data on pages 13, set data: 01 to page: Note 1: If reading/writing data on pages 1C, set data: 01 to page:
0, address: 10, and then select pages: 3. By this data set- 0, address: 10, and then select pages: C. By this data set-
ting, the pages 13 can be selected. ting, the pages 1C can be selected.
After the data reading/writing finished, return the data After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”. on page: 0, address: 10 to“00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, C, 13, 18, 1C Page Data”) the 8, C, 13, 18, 1C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification Fixed data-2: Modified data. (Refer to “2. Modification
of 8, C, 13, 18, 1C Page Data”) of 8, C, 13, 18, 1C Page Data”)

Initial value Initial value


Address Remark Address Remark
NTSC PAL NTSC PAL
00 to 03 Fixed data-1 (Initialized data) 00 to B2 Fixed data-1 (Initialized data)
04 08 08 B3 00 00
05 00 00 B4 00 00
06 46 46 B5 00 00
07 01 01 B6 00 00
Node unique ID No. input
08 02 02 B7 00 00
09 00 00 B8 80 80
0A 00 00 B9 00 00
0B 00 00 BA 00 00
0C to 12 Fixed data-1 (Initialized data) BB 00 00
13 Fixed data-2 BC 00 00
14 to 23 Fixed data-1 (Initialized data) BD 00 00
Error rate check
24 BE 00 00
Fixed data-2
25 BF 00 00
26 to FF Fixed data-1 (Initialized data) C0 00 00
C1 00 00
7. 18 Page table
C2 00 00
Note 1: If reading/writing data on pages 18, set data: 01 to page:
0, address: 10, and then select pages: 8. By this data set- C3 80 80
ting, the pages 18 can be selected. C4 00 00
After the data reading/writing finished, return the data
C5 00 00
on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing C6 00 00
the 8, C, 13, 18, 1C Page Data”) C7 00 00
Fixed data-2: Modified data. (Refer to “2. Modification
C8 00 00
of 8, C, 13, 18, 1C Page Data”)
C9 to FF Fixed data-1 (Initialized data)
Initial value
Address Remark
NTSC PAL
9. 1D Page table
00 to FF Fixed data-1 (Initialized data) Note 1: If reading/writing data on pages 1D, set data: 01 to page:
0, address: 10, and then select pages: D. By this data
setting, the pages 1D can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, 9, C, 13, 18, 1C, 1D Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, 9, C, 13, 18, 1C, 1D Page Data”)

Initial value
Address Remark
NTSC PAL
00 to FF Fixed data-1 (Initialized data

HDR-FX7/FX7E_ADJ
6-12
1-2-3. Initialization of Camera Contr ol Page Data Adjustment Page CD

1. Initializing of Camera Contr ol Page Data Adjustment Address 00 to FF


Note 1: If “Initialization of Camera Control Page Data” is ex- Adjustment Page CE
ecuted, all data on camera control page are initialized. Adjustment Address 00 to FF
(Only an individual page cannot be initialized)
Adjustment Page CF
Note 2: If the camera control page data has been initialized, the
following adjustments need to be performed again. Adjustment Address 00 to FF
1) Modification of camera control page data
2) Camera system adjustment (if all areas were initial- Initializing method:
ized)
Order Page Address Data Procedure
Adjustment Page 6D
1 0 01 01
Adjustment Address 00 to F9
2 0 10 00
Adjustment Page 6E
Set the following data, and
Adjustment Address 00 to FF
press PAUSE (Write) button.
Adjustment Page 6F (Note 3)
Adjustment Address 10 to FF NTSC model:
Adjustment Page 7B 2D: Initializing all areas
Adjustment Address 00 to 4F 3 6 01 31: Initializing other than
Adjustment Page 8D adjustment address
Adjustment Address 00 to FF PAL model
Adjustment Page 8E 2F: Initializing all areas
Adjustment Address 00 to FF 33: Initializing other than
adjustment address
Adjustment Page 8F
4 6 03 01 Press PAUSE (Write) button.
Adjustment Address 00 to FF
Check the data changes to
Adjustment Page 9D 5 6 02
“01”.
Adjustment Address 00 to 4F
6 6 01 00 Press PAUSE (Write) button.
Adjustment Page 9E
Perform “Modification of
Adjustment Address 00 to FF 7
Camera Control Data”.
Adjustment Page 9F Note 3: If other than adjustment address was initialized, the ad-
Adjustment Address 00 to F3 justed data is not initialized.
Adjustment Page AD
Adjustment Address 00, 01
Adjustment Page AE
Adjustment Address 00 to 8F
Adjustment Page AF
Adjustment Address 00 to FF
Adjustment Page BE
Adjustment Address 00 to FF
Adjustment Page BF
Adjustment Address 00 to FF
Adjustment Page C2
Adjustment Address 00 to FF
Adjustment Page C3
Adjustment Address 00 to FF
Adjustment Page C4
Adjustment Address 00 to FF
Adjustment Page C5
Adjustment Address 00 to FF
Adjustment Page C6
Adjustment Address 00 to DF
Adjustment Page CC
Adjustment Address 00 to FF

HDR-FX7/FX7E_ADJ
6-13
2. Modification of Camera Contr ol Page Data 3. 6D Page table
If the camera control page data has been initialized, change the Note 1: If reading/writing data on pages 6D, set data: 06 to page:
data of the “Fixed data-2” address shown in the following table by 0, address: 10, and then select pages: D. By this data
manual input. setting, the pages 6D can be selected.
After the data reading/writing finished, return the data
Modifying Method: on page: 0, address: 10 to “00”.
1) Before changing the data, select page: 0, address: 01, and set Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
data: 01. the Camera Control Data”)
2) If 2-digit page is selected, set higher-order digit to page: 0, Fixed data-2: Modified data. (Refer to “2. Modification
address: 10 as data, and then select lower-order digit by a usual of Camera Control Data”)
method.
e.g.: Set data: 06 to page: 0, address: 10, and then select page: Initial value
Address Remark
D. Thus, the page 6D can be selected. NTSC PAL
After the modification of data finished, return the data on page: 00 00 00
0, address: 10 to “00”.
3) New data for changing are not shown in the tables because 01 00 00
they are different in destination. When changing the data, copy 02 00 00
the data built in the same model. 03 00 00
Note: If copy the data built in the different model, the camcorder
may not operate. 04 00 00
4) When changing the data, press the PAUSE button of the ad- 05 00 00
justment remote commander each time when setting new data 06 00 00
to write the data in the non-volatile memory.
5) If all areas were initialized, check that the data at the addresses 07 00 00
for adjustment are initial values (adjustment initial values) 08 00 00
listed in the table. If different, change them to the adjustment 09 00 00
initial values.
0A 00 00
Processing after Completing Modification Camera Control 0B 00 00
Data: 0C 00 00
Order Page Address Data Procedure 0D 00 00 Differential gain adj.
1 0 10 00 0E 00 00
2 2 00 29 0F 00 00
3 2 01 29 Press PAUSE button. 10 00 00
11 00 00
12 00 00
13 00 00
14 00 00
15 00 00
16 00 00
17 00 00
18 00 00
19 00 00
1A 00 00
1B 00 00
1C 00 00
1D 00 00
1E to 4F Fixed data-1 (Initialized data)
50 58 58
HALL adj.
51 76 76
52, 53 Fixed data-1 (Initialized data)
54 28 28
HALL adj.
55 D8 D8
56, 57 Fixed data-1 (Initialized data)
58 19 19 HALL adj.
59 to 5B Fixed data-1 (Initialized data)
5C 35 35
LV standard data input
5D 00 00
HDR-FX7/FX7E_ADJ
6-14
6D Page table Initial value
Address Remark
Initial value NTSC PAL
Address Remark
NTSC PAL 8D 42 42
5E 3E 3E MAX GAIN adj. 8E 5F 5F Color reproduction adj. (ND 1)
5F Fixed data-1 (Initialized data) 8F 6A 6A
60 00 00 90 EF EF
61 00 00 91 CE CE
62 00 00 92 40 40
63 00 00 93 50 50
64 00 00 94 F9 F9
65 00 00 95 36 36
66 00 00 F No. and ND light quality standard 96 5E 5E
67 00 00 data input 97 60 60
68 00 00 98 EF EF
69 00 00 99 CD CD
6A 00 00 9A 3F 3F
6B 00 00 9B 50 50
6C 00 00 9C FF FF
6D 00 00 9D 42 42
6E 00 00 9E 5F 5F Color reproduction adj. (ND 2)
6F 00 00 9F 6A 6A
70 EF EF A0 EF EF
71 CE CE A1 CE CE
72 40 40 A2 40 40
73 50 50 A3 50 50
74 F9 F9 A4 F9 F9
75 36 36 A5 36 36
76 5E 5E A6 5E 5E
77 60 60 A7 60 60
78 EF EF A8 EF EF
79 CD CD A9 CD CD
7A 3F 3F AA 3F 3F
7B 50 50 AB 50 50
7C FF FF AC FF FF
7D 42 42 Color reproduction adj. (ND 1) AD 42 42
7E 5F 5F AE 5F 5F
7F 6A 6A AF 6A 6A
80 EF EF B0 04 04
81 CE CE B1 00 00
82 40 40 B2 00 00
83 50 50 B3 00 00
84 F9 F9 B4 00 00
85 36 36 B5 00 00 Linear matrix adj.
86 5E 5E B6 00 00
87 60 60 B7 00 00
88 EF EF B8 04 04
89 CD CD B9 00 00
8A 3F 3F BA 00 00
8B 50 50 BB 00 00
8C FF FF

HDR-FX7/FX7E_ADJ
6-15
6D Page table Initial value
Address Remark
Initial value NTSC PAL
Address Remark
NTSC PAL EB 0D 0D
BC 00 00 EC FF FF
BD 00 00 ED DF DF
BE 00 00 EE 04 04
BF 00 00 EF B6 B6
C0 04 04 F0 FF FF
C1 00 00 F1 1B 1B Linear matrix adj.
C2 04 04 F2 FF FF
C3 00 00 F3 F0 F0
C4 00 00 F4 FF FF
C5 00 00 F5 F2 F2
C6 00 00 F6 04 04
C7 00 00 F7 21 21
C8 00 00 F8, F9 Fixed data-1 (Initialized data)
C9 00 00
CA 04 04
CB 00 00
CC 00 00
CD 00 00
CE 00 00
CF 00 00
D0 00 00
D1 00 00 Linear matrix adj.
D2 04 04
D3 00 00
D4 04 04
D5 01 01
D6 FF FF
D7 FA FA
D8 FF FF
D9 E8 E8
DA FF FF
DB F5 F5
DC 04 04
DD 3E 3E
DE FF FF
DF AD AD
E0 00 00
E1 07 07
E2 00 00
E3 02 02
E4 04 04
E5 2E 2E
E6 05 05
E7 9D 9D
E8 FF FF
E9 01 01
EA 00 00

HDR-FX7/FX7E_ADJ
6-16
4. 6E Page table Initial value
Note 1: If reading/writing data on pages 6E, set data: 06 to page: Address Remark
0, address: 10, and then select pages: E. By this data set- NTSC PAL
ting, the pages 6E can be selected. 29 00 00
After the data reading/writing finished, return the data 2A 00 00
on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing 2B 00 00
the Camera Control Data”) 2C 00 00
Fixed data-2: Modified data. (Refer to “2. Modification 2D 00 00
of Camera Control Data”)
2E 00 00
Initial value 2F 00 00
Address Remark
NTSC PAL 30 00 00
00 00 00 31 00 00
01 00 00 32 00 00
02 00 00 33 00 00
03 00 00 34 00 00
04 00 00 35 00 00
05 00 00 36 00 00
06 00 00 37 00 00
07 00 00 38 00 00
08 00 00 39 00 00
09 00 00 3A 00 00
0A 00 00 3B 00 00
0B 00 00 3C 00 00
0C 00 00 3D 00 00 Differential gain adj.
0D 00 00 3E 00 00
0E 00 00 3F 00 00
0F 00 00 40 00 00
10 00 00 41 00 00
11 00 00 42 00 00
12 00 00 43 00 00
13 00 00 Differential gain adj. 44 00 00
14 00 00 45 00 00
15 00 00 46 00 00
16 00 00 47 00 00
17 00 00 48 00 00
18 00 00 49 00 00
19 00 00 4A 00 00
1A 00 00 4B 00 00
1B 00 00 4C 00 00
1C 00 00 4D 00 00
1D 00 00 4E 00 00
1E 00 00 4F 00 00
1F 00 00 50 00 00
20 00 00 51 00 00
21 00 00 52 00 00
22 00 00 53 00 00
23 00 00 54 00 00
24 00 00 55 00 00
25 00 00 56 00 00
26 00 00 57 00 00
27 00 00
28 00 00
HDR-FX7/FX7E_ADJ
6-17
6E Page table Initial value
Address Remark
Initial value NTSC PAL
Address Remark
NTSC PAL 87 00 00
58 00 00 88 00 00
59 00 00 89 00 00
5A 00 00 8A 00 00
5B 00 00 8B 00 00
5C 00 00 8C 00 00
5D 00 00 8D 00 00
5E 00 00 8E 00 00
5F 00 00 8F 00 00
60 00 00 90 00 00
61 00 00 91 00 00
62 00 00 92 00 00
63 00 00 93 00 00
64 00 00 94 00 00
65 00 00 95 00 00
66 00 00 96 00 00
67 00 00 97 00 00
68 00 00 98 00 00
69 00 00 99 00 00
6A 00 00 9A 00 00
6B 00 00 9B 00 00
6C 00 00 9C 00 00
6D 00 00 9D 00 00
6E 00 00 Differential gain adj. 9E 00 00 Differential gain adj.
6F 00 00 9F 00 00
70 00 00 A0 00 00
71 00 00 A1 00 00
72 00 00 A2 00 00
73 00 00 A3 00 00
74 00 00 A4 00 00
75 00 00 A5 00 00
76 00 00 A6 00 00
77 00 00 A7 00 00
78 00 00 A8 00 00
79 00 00 A9 00 00
7A 00 00 AA 00 00
7B 00 00 AB 00 00
7C 00 00 AC 00 00
7D 00 00 AD 00 00
7E 00 00 AE 00 00
7F 00 00 AF 00 00
80 00 00 B0 00 00
81 00 00 B1 00 00
82 00 00 B2 00 00
83 00 00 B3 00 00
84 00 00 B4 00 00
85 00 00 B5 00 00
86 00 00

HDR-FX7/FX7E_ADJ
6-18
6E Page table Initial value
Address Remark
Initial value NTSC PAL
Address Remark
NTSC PAL E5 00 00
B6 00 00 E6 00 00
B7 00 00 E7 00 00
B8 00 00 E8 00 00
B9 00 00 E9 00 00
BA 00 00 EA 00 00 Differential gain adj.
BB 00 00 EB 00 00
BC 00 00 EC 00 00
BD 00 00 ED 00 00
BE 00 00 EE 00 00
BF 00 00 EF 00 00
C0 00 00 F0 00 00
C1 00 00 F1 00 00
C2 00 00 F2 00 00
C3 00 00 F3 00 00 Linearity adj.
C4 00 00 F4 00 00
C5 00 00 F5 00 00
C6 00 00 F6 00 00
C7 00 00 F7 00 00
C8 00 00 F8 to FF Fixed data-1 (Initialized data)
C9 00 00
CA 00 00
CB 00 00
CC 00 00 Differential gain adj.
CD 00 00
CE 00 00
CF 00 00
D0 00 00
D1 00 00
D2 00 00
D3 00 00
D4 00 00
D5 00 00
D6 00 00
D7 00 00
D8 00 00
D9 00 00
DA 00 00
DB 00 00
DC 00 00
DD 00 00
DE 00 00
DF 00 00
E0 00 00
E1 00 00
E2 00 00
E3 00 00
E4 00 00

HDR-FX7/FX7E_ADJ
6-19
5. 6F Page table Initial value
Note 1: If reading/writing data on pages 6F, set data: 06 to page: Address Remark
0, address: 10, and then select pages: F. By this data set- NTSC PAL
ting, the pages 6F can be selected. 46 40 40
After the data reading/writing finished, return the data 47 C0 C0
on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing 48 40 40
MR adj.
the Camera Control Data”) 49 C0 C0
Fixed data-2: Modified data. (Refer to “2. Modification 4A 40 40
of Camera Control Data”)
4B C0 C0
Initial value 4C 00 00
Address Remark Flange back adj.
NTSC PAL 4D 00 00
10 Fixed data-1 (Initialized data) 4E to 5F Fixed data-1 (Initialized data)
11 80 80 Flange back adj. 60 20 20
12 to 1F Fixed data-1 (Initialized data) 61 00 00
20 15 15 62 00 00
21 48 48 63 00 00
22 A8 A8 64 00 00
23 A1 A1 65 00 00
24 29 29 66 00 00
25 62 62 67 00 00 Linear matrix adj.
26 00 00 68 20 20
27 00 00 69 00 00
Flange back adj.
28 00 00 6A 00 00
29 00 00 6B 00 00
2A E5 E5 6C 00 00
2B 19 19 6D 00 00
2C 19 19 6E 00 00
2D 26 26 6F 00 00
2E 00 00 70 20 20
2F 06 06 71 00 00
30 00 00 MR adj./Flange back adj. 72 to 83 Fixed data-1 (Initialized data)
31 00 00 84 2D 2D
32 00 00 85 44 44
Auto white balance adj. (ND OFF)
33 00 00 86 5C 5C
34 00 00 87 C7 C7
35 00 00 88 1B 1B
36 00 00 89 DF DF Auto white balance standard data in
37 00 00 8A 05 05 put (ND OFF)
38 00 00 Flange back adj. 8B 29 29
39 00 00 8C 1B 1B
3A 00 00 8D DF DF Auto white balance standard data in
3B 00 00 8E 05 05 put (ND 1)
3C 00 00 8F 29 29
3D 00 00 90 1B 1B
3E 00 00 91 DF DF Auto white balance standard data in
3F 00 00 92 05 05 put (ND 2)
40 80 80 93 29 29
41 80 80 94 to 97 Fixed data-1 (Initialized data)
42 80 80 98 10 10
MR adj. Auto white balance adj. (ND OFF)
43 80 80 99 6B 6B
44 40 40
45 C0 C0
HDR-FX7/FX7E_ADJ
6-20
Ver. 1.4 2008.06

6F Page table 6. 7B Page table


Note 1: If reading/writing data on pages 7B, set data: 07 to page:
Initial value 0, address: 10, and then select pages: B. By this data set-
Address Remark
NTSC PAL ting, the pages 7B can be selected.
9A 08 08 After the data reading/writing finished, return the data
Auto white balance adj. (ND OFF) on page: 0, address: 10 to “00”.
9B D4 D4 Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
9C 10 10 the Camera Control Data”)
9D 6B 6B Fixed data-2: Modified data. (Refer to “2. Modification
Auto white balance adj. (ND 1) of Camera Control Data”)
9E 08 08
9F D4 D4 Initial value
Address Remark
A0 10 10 NTSC PAL
A1 6B 6B 00 to 4F Fixed data-1 (Initialized data)
Auto white balance adj. (ND 2)
A2 08 08
A3 D4 D4 7. 8D Page table
Note 1: If reading/writing data on pages 8D, set data: 08 to page:
A4 to A7 Fixed data-1 (Initialized data) 0, address: 10, and then select pages: D. By this data
A8 00 00 setting, the pages 8D can be selected.
A9 C4 C4 After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
AA 47 47 Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
AB 47 47 the Camera Control Data”)
AC 0C 0C Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
AD B4 B4
AE 47 47 Initial value
Address Remark
AF 4A 4A NTSC PAL
B0 00 00 00 to 22 Fixed data-1 (Initialized data)
B1 C4 C4 23
B2 47 47 24
B3 47 47 25 Fixed data-2
B4 0C 0C 26
B5 B4 B4 27
B6 47 47 Color reproduction adj. (ND OFF) 28, 29 Fixed data-1 (Initialized data)
B7 4A 4A 2A
B8 FD FD 2B
B9 B9 B9 2C
Fixed data-2
BA 45 45 2D
BB 47 47 2E
BC 03 03 2F
BD AC AC 30 to 34 Fixed data-1 (Initialized data)
BE 40 40 35
Fixed data-2
BF 41 41 36
C0 FD FD 37, 38 Fixed data-1 (Initialized data)
C1 B9 B9 39
Fixed data-2
C2 45 45 3A
C3 47 47 3B to 4B Fixed data-1 (Initialized data)
C4 03 03 4C
C5 AC AC 4D
C6 40 40 4E
Fixed data-2
C7 41 41 4F
C8 to FF Fixed data-1 (Initialized data) 50
51
52 to 57 Fixed data-1 (Initialized data)

HDR-FX7/FX7E_ADJ
6-21
Ver. 1.4 2008.06

8D Page table Initial value


Address Remark
Initial value NTSC PAL
Address Remark
NTSC PAL C8
58 C9
59 CA
Fixed data-2
5A CB
Fixed data-2
5B CC
5C CD
5D CE to D9 Fixed data-1 (Initialized data)
5E to 69 Fixed data-1 (Initialized data) DA
6A DB Fixed data-2
6B Fixed data-2 DC
6C DD to DF Fixed data-1 (Initialized data)
6D to 6F Fixed data-1 (Initialized data) E0
70 E1 Fixed data-2
71 Fixed data-2 E2
72 E3 to F3 Fixed data-1 (Initialized data)
73 to 83 Fixed data-1 (Initialized data) F4
Fixed data-2
84 F5
85 F6 to FB Fixed data-1 (Initialized data)
86 FC
Fixed data-2 Fixed data-2
87 FD
88 FE Fixed data-1 (Initialized data)
89 FF Fixed data-2
8A to 8F Fixed data-1 (Initialized data)
90
91
92
Fixed data-2
93
94
95
96 to A1 Fixed data-1 (Initialized data)
A2
A3 Fixed data-2
A4
A5 to A7 Fixed data-1 (Initialized data)
A8
A9 Fixed data-2
AA
AB to BB Fixed data-1 (Initialized data)
BC
BD
BE
Fixed data-2
BF
C0
C1
C2 to C7 Fixed data-1 (Initialized data)

HDR-FX7/FX7E_ADJ
6-22
8. 8E Page table 9. 8F Page table
Note 1: If reading/writing data on pages 8E, set data: 08 to page: Note 1: If reading/writing data on pages 8F, set data: 08 to page:
0, address: 10, and then select pages: E. By this data set- 0, address: 10, and then select pages: F. By this data set-
ting, the pages 8E can be selected. ting, the pages 8F can be selected.
After the data reading/writing finished, return the data After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”. on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”) the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”) of Camera Control Data”)

Initial value Initial value


Address Remark Address Remark
NTSC PAL NTSC PAL
00 to 50 Fixed data-1 (Initialized data) 00 to 17 Fixed data-1 (Initialized data)
51 18 Fixed data-2
Fixed data-2
52 19 to 1F Fixed data-1 (Initialized data)
53 Fixed data-1 (Initialized data) 20 Fixed data-2
54 21 Fixed data-1 (Initialized data)
Fixed data-2
55 22
56, 57 Fixed data-1 (Initialized data) 23 Fixed data-2
58 24
59 25, 26 Fixed data-1 (Initialized data)
5A 27 Fixed data-2
5B Fixed data-2 28 to 73 Fixed data-1 (Initialized data)
5C 74
Fixed data-2
5D 75
5E 76 to 82 Fixed data-1 (Initialized data)
5F 83
60 to B7 Fixed data-1 (Initialized data) 84
Fixed data-2
B8 Fixed data-2 85
B9 to BF Fixed data-1 (Initialized data) 86
C0 Fixed data-2 87, 88 Fixed data-1 (Initialized data)
C1 to FF Fixed data-1 (Initialized data) 89 Fixed data-2
8A to 8E Fixed data-1 (Initialized data)
8F Fixed data-2
90 to 93 Fixed data-1 (Initialized data)
94 Fixed data-2
95 to 97 Fixed data-1 (Initialized data)
98 Fixed data-2
99 to F7 Fixed data-1 (Initialized data)
F8 Fixed data-2
F9 to FB Fixed data-1 (Initialized data)
FC
FD Fixed data-2
FE
FF Fixed data-1 (Initialized data)

HDR-FX7/FX7E_ADJ
6-23
10. 9D Page table 13. AD Page table
Note 1: If reading/writing data on pages 9D, set data: 09 to page: Note 1: If reading/writing data on pages AD, set data: 0A to page:
0, address: 10, and then select pages: D. By this data 0, address: 10, and then select pages: D. By this data
setting, the pages 9D can be selected. setting, the pages AD can be selected.
After the data reading/writing finished, return the data After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”. on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”) the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”) of Camera Control Data”)

Initial value Initial value


Address Remark Address Remark
NTSC PAL NTSC PAL
00 to 4F Fixed data-1 (Initialized data) 00, 01 Fixed data-1 (Initialized data)

11. 9E P age table 14. AE Page table


Note 1: If reading/writing data on pages 9E, set data: 09 to page: Note 1: If reading/writing data on pages AE, set data: 0A to page:
0, address: 10, and then select pages: E. By this data set- 0, address: 10, and then select pages: E. By this data set-
ting, the pages 9E can be selected. ting, the pages AE can be selected.
After the data reading/writing finished, return the data After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”. on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”) the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”) of Camera Control Data”)

Initial value Initial value


Address Remark Address Remark
NTSC PAL NTSC PAL
00 to 7C Fixed data-1 (Initialized data) 00 to 53 Fixed data-1 (Initialized data)
7D Fixed data-2 54
Fixed data-2
7E to FF Fixed data-1 (Initialized data) 55
56 to 83 Fixed data-1 (Initialized data)
12. 9F Page table 84 Fixed data-2
Note 1: If reading/writing data on pages 9F, set data: 09 to page: 85 to 8F Fixed data-1 (Initialized data)
0, address: 10, and then select pages: F. By this data set-
ting, the pages 9F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)

Initial value
Address Remark
NTSC PAL
00 to F3 Fixed data-1 (Initialized data)

HDR-FX7/FX7E_ADJ
6-24
15. AF Page table 17. BF Page table
Note 1: If reading/writing data on pages AF, set data: 0A to page: Note 1: If reading/writing data on pages BF, set data: 0B to page:
0, address: 10, and then select pages: F. By this data set- 0, address: 10, and then select pages: F. By this data set-
ting, the pages AF can be selected. ting, the pages BF can be selected.
After the data reading/writing finished, return the data After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”. on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”) the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”) of Camera Control Data”)

Initial value Initial value


Address Remark Address Remark
NTSC PAL NTSC PAL
00 Fixed data-2 00 to 07 Fixed data-1 (Initialized data)
01 to 37 Fixed data-1 (Initialized data) 08 Fixed data-2
38 09 to 3D Fixed data-1 (Initialized data)
39 3E Fixed data-2
3A Fixed data-2 3F to 44 Fixed data-1 (Initialized data)
3B 45 Fixed data-2
3C 46 to 64 Fixed data-1 (Initialized data)
3D to 4E Fixed data-1 (Initialized data) 65 Fixed data-2
4F Fixed data-2 66 Fixed data-1 (Initialized data)
50 to FF Fixed data-1 (Initialized data) 67 Fixed data-2
68 Fixed data-1 (Initialized data)
16. BE Page table 69
Note 1: If reading/writing data on pages BE, set data: 0B to page: Fixed data-2
6A
0, address: 10, and then select pages: E. By this data set-
ting, the pages BE can be selected. 6B to 71 Fixed data-1 (Initialized data)
After the data reading/writing finished, return the data 72
on page: 0, address: 10 to “00”. Fixed data-2
73
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”) 74 to AC Fixed data-1 (Initialized data)
Fixed data-2: Modified data. (Refer to “2. Modification AD
of Camera Control Data”) AE
Fixed data-2
Initial value AF
Address Remark
NTSC PAL B0
00 to 7D Fixed data-1 (Initialized data) B1 to BF Fixed data-1 (Initialized data)
7E Fixed data-2 C0
Fixed data-2
7F to FF Fixed data-1 (Initialized data) C1
C2 to FF Fixed data-1 (Initialized data)

HDR-FX7/FX7E_ADJ
6-25
18. C2 Page table 21. C5 Page table
Note 1: If reading/writing data on pages C2, set data: 0C to page: Note 1: If reading/writing data on pages C5, set data: 0C to page:
0, address: 10, and then select pages: 2. By this data set- 0, address: 10, and then select pages: 5. By this data set-
ting, the pages C2 can be selected. ting, the pages C5 can be selected.
After the data reading/writing finished, return the data After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”. on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”) the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”) of Camera Control Data”)

Initial value Initial value


Address Remark Address Remark
NTSC PAL NTSC PAL
00 to FF Fixed data-1 (Initialized data) 00 to FF Fixed data-1 (Initialized data)

19. C3 Page table 22. C6 Page table


Note 1: If reading/writing data on pages C3, set data: 0C to page: Note 1: If reading/writing data on pages C6, set data: 0C to page:
0, address: 10, and then select pages: 3. By this data set- 0, address: 10, and then select pages: 6. By this data set-
ting, the pages C3 can be selected. ting, the pages C6 can be selected.
After the data reading/writing finished, return the data After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”. on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”) the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”) of Camera Control Data”)

Initial value Initial value


Address Remark Address Remark
NTSC PAL NTSC PAL
00 to FF Fixed data-1 (Initialized data) 00 to DF Fixed data-1 (Initialized data)

20. C4 Page table 23. CC Page table


Note 1: If reading/writing data on pages C4, set data: 0C to page: Note 1: If reading/writing data on pages CC, set data: 0C to page:
0, address: 10, and then select pages: 4. By this data set- 0, address: 10, and then select pages: C. By this data set-
ting, the pages C4 can be selected. ting, the pages CC can be selected.
After the data reading/writing finished, return the data After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”. on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”) the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”) of Camera Control Data”)

Initial value Initial value


Address Remark Address Remark
NTSC PAL NTSC PAL
00 to FF Fixed data-1 (Initialized data) 00 to FF Fixed data-1 (Initialized data)

HDR-FX7/FX7E_ADJ
6-26
24. CD Page table Initial value
Note 1: If reading/writing data on pages CD, set data: 0C to page: Address Remark
0, address: 10, and then select pages: D. By this data NTSC PAL
setting, the pages CD can be selected. 77
After the data reading/writing finished, return the data 78
on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing 79
the Camera Control Data”) 7A
Fixed data-2: Modified data. (Refer to “2. Modification 7B
of Camera Control Data”)
7C
Initial value 7D Fixed data-2
Address Remark
NTSC PAL 7E
00 to 0C Fixed data-1 (Initialized data) 7F
0D Fixed data-2 80
0E to 2F Fixed data-1 (Initialized data) 81
30 Fixed data-2 82
31 Fixed data-1 (Initialized data) 83
32 84 Fixed data-1 (Initialized data)
33 85
Fixed data-2
34 86
35 87
36, 37 Fixed data-1 (Initialized data) 88 Fixed data-2
38 Fixed data-2 89
39 Fixed data-1 (Initialized data) 8A
3A 8B
3B 8C, 8D Fixed data-1 (Initialized data)
Fixed data-2
3C 8E
3D 8F
3E to 4F Fixed data-1 (Initialized data) Fixed data-2
90
50 Fixed data-2 91
51 to 57 Fixed data-1 (Initialized data) 92, 93 Fixed data-1 (Initialized data)
58 94
59 95
Fixed data-2 Fixed data-2
5A 96
5B 97
5C, 5D Fixed data-1 (Initialized data) 98 to 9F Fixed data-1 (Initialized data)
5E A0
5F A1
Fixed data-2
60 A2
61 A3
62, 63 Fixed data-1 (Initialized data) A4
64 A5
65 A6
Fixed data-2
66 A7 Fixed data-2
67 A8
68 to 6F Fixed data-1 (Initialized data) A9
70 AA
71 AB
72 AC
73 Fixed data-2 AD
74 AE
75
76
HDR-FX7/FX7E_ADJ
6-27
CD Page table

Initial value
Address Remark
NTSC PAL
AF
B0
B1 Fixed data-2
B2
B3
B4 Fixed data-1 (Initialized data)
B5
B6 Fixed data-2
B7
B8 to F5 Fixed data-1 (Initialized data)
F6 Fixed data-2
F7 Fixed data-1 (Initialized data)
F8 Fixed data-2
F9 to FF Fixed data-1 (Initialized data)

HDR-FX7/FX7E_ADJ
6-28
25. CE Page table Initial value
Note 1: If reading/writing data on pages CE, set data: 0C to page: Address Remark
0, address: 10, and then select pages: E. By this data set- NTSC PAL
ting, the pages CE can be selected. 6F to 83 Fixed data-1 (Initialized data)
After the data reading/writing finished, return the data 84
on page: 0, address: 10 to “00”. Fixed data-2
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing 85
the Camera Control Data”) 86 to 92 Fixed data-1 (Initialized data)
Fixed data-2: Modified data. (Refer to “2. Modification 93 Fixed data-2
of Camera Control Data”)
94 to 9B Fixed data-1 (Initialized data)
Initial value 9C
Address Remark
NTSC PAL 9D
00 to 07 Fixed data-1 (Initialized data) Fixed data-2
9E
08 Fixed data-2 9F
09 to 10 Fixed data-1 (Initialized data) A0 to BC Fixed data-1 (Initialized data)
11 Fixed data-2 BD
12 Fixed data-1 (Initialized data) BE Fixed data-2
13 Fixed data-2 BF
14, 15 Fixed data-1 (Initialized data) C0, C1 Fixed data-1 (Initialized data)
16 C2 Fixed data-2
Fixed data-2
17 C3 Fixed data-1 (Initialized data)
18 Fixed data-1 (Initialized data) C4
19 Fixed data-2
Fixed data-2 C5
1A C6 Fixed data-1 (Initialized data)
1B to 1E Fixed data-1 (Initialized data) C7 Fixed data-2
1F Fixed data-2 C8 to CA Fixed data-1 (Initialized data)
20 Fixed data-1 (Initialized data) CB Fixed data-2
21 Fixed data-2 CC, CD Fixed data-1 (Initialized data)
22 Fixed data-1 (Initialized data) CE Fixed data-2
23 CF to FE Fixed data-1 (Initialized data)
Fixed data-2
24 FF Fixed data-2
25 Fixed data-1 (Initialized data)
26 Fixed data-2 26. CF Page table
27 to 2E Fixed data-1 (Initialized data) Note 1: If reading/writing data on pages CF, set data: 0C to page:
2F 0, address: 10, and then select pages: F. By this data set-
ting, the pages CF can be selected.
30 After the data reading/writing finished, return the data
31 on page: 0, address: 10 to “00”.
Fixed data-2 Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
32
the Camera Control Data”)
33 Fixed data-2: Modified data. (Refer to “2. Modification
34 of Camera Control Data”)
35 Fixed data-1 (Initialized data) Initial value
36 Fixed data-2 Address Remark
NTSC PAL
37 Fixed data-1 (Initialized data) 00 to FF Fixed data-1 (Initialized data)
38 Fixed data-2
39 to 62 Fixed data-1 (Initialized data)
63
Fixed data-2
64
65 to 68 Fixed data-1 (Initialized data)
69
Fixed data-2
6A
6B, 6C Fixed data-1 (Initialized data)
6D
Fixed data-2
6E
HDR-FX7/FX7E_ADJ
6-29
1-2-4. Initialization of 7C, 7E, 7F Page Data 2. Modification of 7C, 7E, 7F Page Data
If the 7C, 7E, 7F page data has been initialized, change the data of
Note 1: If “Initialization of Pages 7C, 7E, 7F” is executed, all the “Fixed data-2” address shown in the following table by manual
data on pages 7C, 7E, 7F are initialized. input.
(Only an individual page cannot be initialized)
Note 2: If the 7C, 7E, 7F page data has been initialized, the fol- Modifying Method:
lowing adjustments need to be performed again. 1) Before changing the data, select page: 0, address: 01, and set
1) Modification of 7C, 7E, 7F page data data: 01.
2) PSD sensor gradient adjustment (if all areas were ini- 2) If modification of data on pages 7C, 7E, 7F, set data: 01 to
tialized) page: 0, address: 10, and then select pages C, E, F.
3) Optical axis adjustment (if all areas were initialized) After the modification of data finished, return the data on page:
4) Angular velocity sensor sensitivity adjustment (if all 0, address: 10 to “00”.
areas were initialized) 3) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
Adjustment Page 7C
the data built in the same model.
Adjustment Address 00 to FF Note: If copy the data built in the different model, the camcorder
Adjustment Page 7E may not operate.
4) When changing the data, press the PAUSE button of the ad-
Adjustment Address 00 to FF
justment remote commander each time when setting new data
Adjustment Page 7F to write the data in the non-volatile memory.
Adjustment Address 00 to FF 5) If all areas were initialized, check that the data at the addresses
for adjustment are initial values (adjustment initial values)
listed in the table. If different, change them to the adjustment
Initializing method: initial values.
Order Page Address Data Procedure
Processing after Completing Modification Camera Control
1 0 01 01
Data:
2 0 10 07
Order Page Address Data Procedure
Set the following data, and
press PAUSE (Write) button. 1 0 10 00
2 (Note 3) 2 2 00 29
3 (72) 01 2D: Initializing all areas 3 2 01 29 Press PAUSE button.
31: Initializing other than
adjustment address
2 Check the data changes to
4 02
(72) “01”.
2
5 01 00 Press PAUSE (Write) button.
(72)
6 0 10 00
Perform “Modification of
7
7C, 7E, 7F Page Data”.
Note 3: If other than adjustment address was initialized, the ad-
justed data is not initialized.

HDR-FX7/FX7E_ADJ
6-30
Ver. 1.4 2008.06

3. 7C Page table Initial value


Note 1: If reading/writing data on pages 7C, set data: 07 to page: Address Remark
NTSC PAL
0, address: 10, and then select pages: C. By this data set-
ting, the pages 7C can be selected. F0
After the data reading/writing finished, return the data F1
on page: 0, address: 10 to “00”. Fixed data-2
F2
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the 7C, 7E, 7F Page Data”) F3
Fixed data-2: Modified data. (Refer to “2. Modification F4 to FF Fixed data-1 (Initialized data)
of 7C, 7E, 7F Page Data”)

Initial value 5. 7F Page table


Address Remark Note 1: If reading/writing data on pages 7F, set data: 07 to page:
NTSC PAL
0, address: 10, and then select pages: F. By this data set-
00 to FF Fixed data-1 (Initialized data) ting, the pages 7F can be selected.
After the data reading/writing finished, return the data
4. 7E Page table on page: 0, address: 10 to “00”.
Note 1: If reading/writing data on pages 7E, set data: 07 to page: Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
0, address: 10, and then select pages: E. By this data set- the 7C, 7E, 7F Page Data”)
ting, the pages 7E can be selected. Fixed data-2: Modified data. (Refer to “2. Modification
After the data reading/writing finished, return the data of 7C, 7E, 7F Page Data”)
on page: 0, address: 10 to “00”.
Initial value
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing Address Remark
the 7C, 7E, 7F Page Data”) NTSC PAL
Fixed data-2: Modified data. (Refer to “2. Modification 00 to 03 Fixed data-1 (Initialized data)
of 7C, 7E, 7F Page Data”)
04 80 80
PSD sensor gradient adj.
Initial value 05 80 80
Address Remark
NTSC PAL 06 to 0D Fixed data-1 (Initialized data)
00 to 10 Fixed data-1 (Initialized data) 0E 02 02
11 Fixed data-2 0F C2 C2
12 to 23 Fixed data-1 (Initialized data) PSD sensor gradient adj.
10 02 02
24 11 C2 C2
25 12 40 40 Angular velocity sensor sensitivity
26 Fixed data-2 13 40 40 adj.
27 14 to 4F Fixed data-1 (Initialized data)
28 50 00 00
29 to 3A Fixed data-1 (Initialized data) 51 00 00
Optical axis adj.
3B 52 00 00
3C 53 00 00
Fixed data-2
3D 54 to FF Fixed data-1 (Initialized data)
3E
3F Fixed data-1 (Initialized data)
40 Fixed data-2
41 to 5F Fixed data-1 (Initialized data)
60
Fixed data-2
61
62 to B8 Fixed data-1 (Initialized data)
B9 Fixed data-2
BA, BB Fixed data-1 (Initialized data)
BC
Fixed data-2
BD
BE to C0 Fixed data-1 (Initialized data)
C1 Fixed data-2
C2 Fixed data-1 (Initialized data)
C3 Fixed data-2
C4 to EF Fixed data-1 (Initialized data)

HDR-FX7/FX7E_ADJ
6-31
Ver. 1.1 2007.05

1-3. CAMERA SYSTEM ADJUSTMENTS 2. PSD Sensor Gradient Adjustment RadarW


Before perform the camera system adjustments, check that the Adjust the gradient of the PSD sensor.
specified values of “VIDEO SYSTEM ADJUSTMENTS” are sat- Subject Not required
isfied. (Except Origin Oscillation Check”)
Check that the data of page: 0, address: 10 is “00”. Measurement Point
Adjusting remote commander
If not, select page: 0, address: 10, and set the data “00”. Measuring Instrument
Adjustment Page 7F
1. Origin Oscillation Check (TT-003 board)
Check the frequency of the clock for synchronization. Adjustment Address 04, 05, 0E to 11
If deviated, the synchronization will be disrupted and the color Data of page: 7F address: 00 is “00”
will become inconsistent. Specified value Data of page: 7F address: 01 is “00”
Subject Not required Note 1: If reading/writing data on pages 7F, set data: 07 to page:
Measurement Point R1414 (CHCK) on TT-003 board 0, address: 10, and then select pages: F. By this data set-
ting, the pages 7F can be selected.
Measuring Instrument Frequency counter After the data reading/writing finished, return the data
Specified value f = 41538461 ± 835 Hz (NTSC) on page: 0, address: 10 to “00”.
f = 41580000 ± 835 Hz (PAL) Note 2: Perform this adjustment only when replacing the lens
block. When the microprocessor, circuit etc. is damaged,
don't perform this adjustment but check the steady shot
Switch setting
operations only.
1) POWER ......................................................... CAMERA mode
Note 3: Perform the adjustment with the camcorder in horizontal
state.
Checking method:
1) Check that the frequency (f) satisfies the specified value.
Switch setting
1) POWER ......................................................... CAMERA mode
TT-003 BOARD (SIDE A)
R1414 Adjusting method:
Order Page Address Data Procedure
1 0 01 01
2 0 10 07
3 2 01 97 Press PAUSE (Write) button.
(72) (Note 4)
4 2 02 Check the data changes to
(72) “01”.
5 F 00 Check the data is “00”.
(7F) (Note 5)
IC1401 F Check the data is “00”.
6 01
(7F) (Note 5).
Note 4: The adjustment data will be automatically input to page:
7F, address: 04, 05, 0E to 11.
Note 5: If the data is other than “00”, perform readjustment.

Processing after Completing Adjustment:


Order Page Address Data Procedure
1 2 01 00 Press PAUSE (Write) button.
(72)
2 0 10 00
3 0 01 00
Turn off the power and turn
Fig. 6-1-6 4
on again.
Shake the camcorder
5 vertically and horizontally to
check that the steady shot
function operates normally.

HDR-FX7/FX7E_ADJ
6-32
3. HALL Adjustment RadarW 4. MR Adjustment RadarW
For detecting the position of lens iris and ND filter, adjust the hall The inner focus lens MR adjustment is carried out automatically.
AMP gain and offset. In whichever case, the focus will be deviated during auto focus-
ing/manual focusing.
Subject Not required
Measurement Point Subject Not required
Adjusting remote commander Measurement Point
Measuring Instrument Adjusting remote commander
Adjustment Page 6D Measuring Instrument
Adjustment Address 50, 51, 54, 55, 58 Adjustment Page 6F
Specified value Data of page: 6, address: 0C is “00” Adjustment Address 30, 40 to 4B
Specified value Data of page: 6, address: 0C is “00”.
Note 1: If reading/writing data on pages 6D, set data: 06 to
page: 0, address: 10, and then select pages D. By this Note 1: Perform the adjustment with the lens in horizontal
data setting, the pages 6D can be selected. state.
After the data reading/writing finished, return the data Note 2: Perform “Flange Back Adjustment” after this adjustment.
on page: 0, address: 10 to “00”. Note 3: If reading/writing data on pages 6F, set data: 06 to page:
Note 2: Check that the data of page: 6, address: 02 is “00” 0, address: 10, and then select pages F. By this data set-
If not, select page: 6, address: 01, set data: 00, and press ting, the pages 6F can be selected.
the PAUSE (Write) button. After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Switch setting Note 4: Check that the data of page: 6, address: 02 is “00”.
1) POWER ......................................................... CAMERA mode If not, select page: 6, address: 01, set data: 00, and press
the PAUSE (Write) button.
Adjusting method:
Switch setting
Order Page Address Data Procedure 1) POWER ........................................................ CAMERA mode
1 0 01 01
Adjusting method:
2 6 D0 22
Press PAUSE (Write) button. Order Page Address Data Procedure
3 6 01 6D
(Note 3) 1 0 01 01
4 6 02 Check the data changes to “01”. Press PAUSE (Write) button.
2 6 01 BD
5 6 0C Check the data is “00”. (Note 5)
Check the data changes to
Note 3: The adjustment data will be automatically input to page: 3 6 02
“01”.
6D, address: 50, 51, 54, 55, 58.
4 6 0C Check the data is “00”.
Processing after Completing Adjustment: Note 5: The adjustment data will be automatically input to page:
Order Page Address Data Procedure 6F, address: 30, 40 to 4B.
1 6 01 00 Press PAUSE (Write) button.
Processing after Completing Adjustment:
2 0 01 00
Order Page Address Data Procedure
1 6 01 00 Press PAUSE (Write) button.
2 6 01 25 Press PAUSE (Write) button.
Check the data changes to
3 6 02
“01”.
4 6 01 00 Press PAUSE (Write) button.
5 0 01 00

HDR-FX7/FX7E_ADJ
6-33
Ver. 1.1 2007.05

5. Differential Gain Adjustment 5-2. Differential Gain Adjustment (2) RadarW


Correct the dispersion of between the channels of CMOS imager.
5-1. Differential Gain Adjustment (1)
Subject Clear chart (All white) (Note 1)
(Temporary Adjustment of F No.) RadarW
Perform the F No. compensation before “Differential Gain Ad- Adjustment Page 6D 6E
justment (2)”. Adjustment Address 00 to 1D 00 to EF
Subject Clear chart (All white) (Note 1) Note 1: Shoot the clear chart with the zoom TELE end.
Adjustment Page 6D Note 2: If reading/writing data on pages 6D, 6E set data: 06 to
page: 0, address: 10, and then select pages: D, E. By this
Adjustment Address 60 to 6F
data setting, the pages 6D, 6E can be selected.
Note 1: Shoot the clear chart with the zoom TELE end. After the data reading/writing finished, return the data
Note 2: If reading/writing data on pages 6D, set data: 06 to page: on page: 0, address: 10 to “00”.
0, address: 10, and then select pages: D. By this data Note 3: Check that the data of page: 6, address: 02 is “00”. If
setting, the pages 6D can be selected. not, select page: 6, address: 01, set data: 00, and press
After the data reading/writing finished, return the data PAUSE (Write) button.
on page: 0, address: 10 to “00”.
Note 3: Check that the data of page: 6, address: 02 is “00”. Switch setting
If not, select page: 6, address: 01, set data: 00, and press 1) POWER ......................................................... CAMERA mode
PAUSE (Write) button. 2) ND FILTER ...................................................................... OFF
3) ZOOM ..................................................................... TELE end
Switch setting 4) REC FORMAT (Menu setting) ............................. HDV1080i
1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF Adjusting method:
3) FOCUS ................................................................... MANUAL
Order Page Address Data Procedure
4) ZOOM ..................................................................... TELE end
5) REC FORMAT (Menu setting) ............................. HDV1080i 1 0 01 01
6) STEADY SHOT (Menu setting) ..................................... OFF 2 6 2C 01
7) D. EXTENDER (Menu setting) ...................................... OFF
3 6 40 01
Adjusting method: 4 6 D0 60

Order Page Address Data Procedure 5 6 D2 01


6 6 D3 01
1 0 01 01
2 6 17 10 7 6 D6 10

3 6 C9 10 Press PAUSE (Write) button.


8 6 01 F5
(Note 4)
4 6 10 80
9 6 02 Check the data changes to
5 6 D2 60 “01”.
6 6 D3 40
Note 4: The adjustment data will be automatically input to page:
Press PAUSE button. (Note 6D, address: 00 to 1D and page: 6E, address: 00 to EF.
7 6 01 BB
4)
Check the data changes to Processing after Completing Adjustment:
8 6 02
“01”. Order Page Address Data Procedure
Note 4: The adjustment data will be automatically input to page: 1 6 01 00 Press PAUSE (Write) button.
6D, address: 60 to 6F.
2 6 2C 00
Processing after Completing Adjustment: 3 6 40 00
Order Page Address Data Procedure 4 0 01 00
1 6 17 00
2 6 C9 00
3 6 10 00
4 6 01 00 Press PAUSE button.
5 0 01 00

HDR-FX7/FX7E_ADJ
6-34
6. Flange Back Adjustment RadarW Preparation (Using the minipattern box)
(Using the minipattern box or flange back adjust 1) The minipattern box is installed as shown in the following fig-
ment jig) ure.
The inner focus lens flange back adjustment is carried out auto- Note 8: The attachment lenses are not used.
matically. In whichever case, the focus will be deviated during 2) Install the minipattern box so that the distance between it and
auto focusing/manual focusing. the front of lens of camera is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
Subject Siemens star chart with ND filter for
4) Check the output voltage of the regulated power supply is the
minipattern box (Note 1) or flange
specified voltage ± 0.01 Vdc.
back adjustment jig
5) Check that the center of Siemens star chart meets the center of
Measurement Point shot image screen with the zoom lens at TELE end and WIDE
Adjusting remote commander
Measuring Instrument end respectively.
Adjustment Page 6F
Specified voltage: The specified voltage varies according to the
Adjustment Address 11, 20 to 3F, 4C, 4D minipattern box, so adjustment the power sup-
Specified value Data of page: 6F, address: 2F is ply output voltage to the specified voltage writ-
“00” to “0E” ten on the sheet which is supplied with the
Data of pege: 6, address: 0C is “00” minipattern box.
Below 3 cm
Note 1: Dark Siemens star chart.
Note 2: Perform “HALL Adjustment”, “MR Adjustment” and Minipattern box
“Differential Gain Adjustment” before this adjustment.
Note 3: Perform the adjustment with the lens in horizontal state. Camera
Note 4: If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
Regulated power supply
on page: 0, address: 10 to “00”. Output voltage : Specified voltage ± 0.01 Vdc
Note 5: Check that the data of page: 6, address: 02 is “00”. If Output current : more than 3.5 A
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 6: Don't touch the zoom lever during adjustment. Red (+)
Note 7: After adjustment, if the focusing to a subject located at
infinity failed, increase the illuminance of the chart and Black (–)
perform readjustment. Yellow (SENS +)

Switch setting White (SENS –) Need not connected


1) POWER ......................................................... CAMERA mode Black (GND)
2) ND FILTER ...................................................................... OFF
3) REC FORMAT (Menu setting) ............................. HDV1080i Fig. 6-1-7

Preparation (Using the flange back adjustment jig)


(Luminance: 300 to 400 lux)
1) Install the flange back adjustment jig so that the distance be-
tween it and the front of lens of camera is less than 3 cm.
2) Make the height of flange back adjustment jig and the camera
equal.
3) Check that the center of chart meets the center of shot image
screen with the zoom lens at TELE end and WIDE end respec-
tively.

Below 3 cm
Flange back adjustment jig

Camera

Fig. 6-1-8

HDR-FX7/FX7E_ADJ
6-35
Adjusting method:
Order Page Address Data Procedure
1 0 01 01
2 6 64 04
3 0 10 0A
4 E 8C 01 Press PAUSE (Write) button.
(AE)
5 0 10 00
6 6 01 13 Press PAUSE (Write) button.
7 Wait for 2 seconds.
Press PAUSE (Write) button.
8 6 01 27
(Note 9)
9 6 02 Check the data changes to “01”.
10 6 0C Check the data is “00”.
11 0 10 06
12 F 2F Check the data is “00” to “0E”.
(6F)
13 0 10 00
Note 9: The adjustment data will be automatically input to page:
6F, address: 11, 20 to 3F, 4C, 4D.

Processing after Completing Adjustment:


Order Page Address Data Procedure
1 6 01 00 Press PAUSE (Write) button.
2 6 01 25 Press PAUSE (Write) button.
3 6 02 Check the data changes to “01”.
4 6 01 00 Press PAUSE (Write) button.
5 6 64 00
6 0 10 0A
7 E 8C 00 Press PAUSE (Write) button.
(AE)
8 0 10 00
9 0 01 00

10 Perform “Flange Back


Check”.

HDR-FX7/FX7E_ADJ
6-36
7. Flange Back Adjustment Adjusting method:
(Using the flange back adjustment chart and
Order Page Address Data Procedure
subject more than 500 m away)
The inner focus lens flange back adjustment is carried out auto- 1 0 01 01
matically. In whichever case, the focus will be deviated during 2 6 64 04
auto focusing/manual focusing.
3 0 10 0A
7-1. Flange Back Adjustment (1) RadarW 4 E 8C 01 Press PAUSE (Write) button.
(AE)
Subject Flange back adjustment chart
5 0 10 00
(2.0 m from the front of lens)
(Luminance: 300 to 400 lux) 6 6 01 13 Press PAUSE (Write) button.
Measurement Point 7 Wait for 2 seconds.
Adjusting remote commander
Measuring Instrument Press PAUSE (Write) button.
8 6 01 15
(Note 7)
Adjustment Page 6F
9 6 02 Check the data changes to
Adjustment Address 11, 20 to 3F, 4C, 4D
“01”.
Specified value Data of page: 6F, address: 2F is
10 6 0C Check the data is “00”.
“00” to “0E”
Data of page: 6, address: 0C is “00” 11 0 10 06
Note 1: Perform “HALL Adjustment”, “MR Adjustment” and 12 F 2F Check the data is “00” to
“Differential Gain Adjustment” before this adjustment. (6F) “0E”.
Note 2: Perform the adjustment with the lens in horizontal state. 13 0 10 00
Note 3: If reading/writing data on pages 6F, set data: 06 to page:
Note 7: The adjustment data will be automatically input to page:
0, address: 10, and then select pages F. By this data set-
6F, address: 11, 20 to 3F, 4C, 4D.
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
Processing after Completing Adjustment:
on page: 0, address: 10 to “00”.
Note 4: Check that the data of page: 6, address: 02 is “00”. If Order Page Address Data Procedure
not, select page: 6, address: 01, set data: 00, and press 1 6 01 00 Press PAUSE (Write) button.
PAUSE (Write) button.
Note 5: Don't touch the zoom lever during adjustment. 2 6 01 25 Press PAUSE (Write) button.
Note 6: After adjustment, if the focusing to a subject located at 3 6 02 Check the data changes to “01”.
infinity failed, increase the illuminance of the chart and 4 6 01 00 Press PAUSE (Write) button.
perform readjustment.
5 6 64 00
Switch setting 6 0 10 0A
1) POWER ......................................................... CAMERA mode E
7 8C 00 Press PAUSE (Write) button.
2) ND FILTER ...................................................................... OFF (AE)
3) REC FORMAT (Menu setting) ............................. HDV1080i
8 0 10 00
Preparations before adjustments: 9 0 01 00
1) Check that the center of Flange back adjustment chart meets Perform “Flange Back
10
the center of shot image screen with the zoom lens at TELE Adjustment (2)”.
end and WIDE end respectively.

HDR-FX7/FX7E_ADJ
6-37
7-2. Flange Back Adjustment (2) RadarW Adjusting method:
Perform this adjustment after performing “Flange Back Adjust-
Order Page Address Data Procedure
ment (1)”.
1 0 01 01
Subject Subject more than 500 m away
(Subject with clear contrast such as 2 6 64 04
buildings, etc.) 3 0 10 0A
Measurement Point 4 E 8C 01 Press PAUSE (Write) button.
Adjusting remote commander (AE)
Measuring Instrument
Adjustment Page 6F 5 0 10 00

Adjustment Address 11, 20 to 3F, 4C, 4D 6 6 01 13 Press PAUSE (Write) button.

Specified value Data of page: 6F, address: 2F is 7 Wait for 2 seconds.


“00” to “0E” Place ND filter on the lens so
Data of page: 6, address: 0C is“00” 8 that the optimum image is
obtain.
Note 1: Perform the adjustment with the lens in horizontal state.
Note 2: If reading/writing data on pages 6F, set data: 06 to page: Press PAUSE (Write) button.
9 6 01 29
0, address: 10, and then select pages F. By this data set- (Note 5)
ting, the pages 6F can be selected. 10 6 02 Check the data changes to “01”.
After the data reading/writing finished, return the data 11 6 0C Check the data is “00”.
on page: 0, address: 10 to “00”.
Note 3: Check that the data of page: 6, address: 02 is “00”. If 12 0 10 06
not, select page: 6, address: 01, set data: 00, and press 13 F 2F Check the data is “00” to “0E”.
PAUSE (Write) button. (6F)
Note 4: Don’t touch the zoom lever during adjustment. 14 0 10 00

Switch setting Note 5: The adjustment data will be automatically input to page:
1) POWER ......................................................... CAMERA mode 6F, address: 11, 20 to 3F, 4C, 4D.
2) ND FILTER ...................................................................... OFF
3) REC FORMAT (Menu setting) ............................. HDV1080i Processing after Completing Adjustment:
Order Page Address Data Procedure
Preparations before adjustments:
1) Set the zoom lens to the TELE end and expose a subject that is 1 6 01 00 Press PAUSE (Write) button.
more than 500 m away. 2 6 01 25 Press PAUSE (Write) button.
(subjects with clear contrast such as building, etc.) 3 6 02 Check the data changes to “01”.
(Nearby subjects less than 500 m away should not be in the
screen) 4 6 01 00 Press PAUSE (Write) button.
5 6 64 00
6 0 10 0A
7 E 8C 00 Press PAUSE (Write) button.
(AE)
8 0 10 00
9 0 01 00

10 Perform “Flange Back


Check”.

HDR-FX7/FX7E_ADJ
6-38
8. Flange Back Check 9. Flange Back Check (Using the Siemens star)
(Using the flange back adjustment jig)
Subject Siemens star
Subject Flange back adjustment jig (2.0 m from the front of the lens)
(Luminance: approx. 200 lux) (Luminance: approx. 200 lux)
Measurement Point Measurement Point
Check operation on monitor TV Check operation on monitor TV
Measuring Instrument Measuring Instrument
Specified value Focused at the TELE end and WIDE Specified value Focused at the TELE end and WIDE
end end
Note: Check that the data of page: 0, address: 10 is “00”. Note 1: Check that the data of page: 0, address: 10 is “00”.

Switch setting Switch setting


1) POWER ......................................................... CAMERA mode 1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF 2) ND FILTER ...................................................................... OFF
3) REC FORMAT (Menu setting) ............................. HDV1080i 3) REC FORMAT (Menu setting) ............................. HDV1080i

Preparations before adjustments: Note 2: When the auto focus is ON, the lens can be checked if it
1) Install the flange back adjustment jig so that the distance be- is focused or not by observing the data on the page: 1 of
tween it and the front of lens of camera is less than 3 cm. the adjusting remote commander.
2) To open the IRIS, decrease the luminous intensity to the chart 1 : 00 : XX
of the flange back adjustment jig up to a point before noise Odd: Focused
appear on the image. (approx. 200 lux) Even: Unfocused
3) Check that the center of chart meets the center of shot image
screen with the zoom lens at TELE end and WIDE end respec- Preparations before adjustments:
tively. 1) Place the Siemens star 2.0 m from the front of the lens.
2) To open the IRIS, decrease the luminous intensity to the Si-
Checking method: emens star up to a point before noise appear on the image.
Order Page Address Data Procedure
Checking method:
1 6 40 01
Order Page Address Data Procedure
2 6 41 01
1 6 40 01
3 6 4D 40
2 6 41 01
Shoot the chart with the
4 3 6 4D 40
zoom TELE end.
5 6 2C 02 4 Shoot the Siemens star with
the zoom TELE end.
Check that the lens is
6 5 Turn on the auto focus.
focused.
Shoot the chart with the 6 0 03 0F
7
zoom WIDE end. 7 Check that the lens is
1
Check that the lens is focused. (Note 2)
8
focused. 8 6 21 10

9 Shoot the Siemens star with


Processing after Completing Adjustment: the zoom WIDE end.
Observe the TV monitor and
Order Page Address Data Procedure
10 check that the lens is
1 6 2C 00 focused.
2 6 40 00
3 6 41 00 Processing after Completing Adjustment:
4 6 4D 00 Order Page Address Data Procedure
1 6 21 00
2 6 40 00
3 6 41 00
4 6 4D 40
5 0 03 00

HDR-FX7/FX7E_ADJ
6-39
10. Optical Axis Adjustment
Correct a deviation of optical axis between the lens and the imager.
If deviated, the screen center will be shifted when the lens is zoomed
from TELE end to WIDE end.
Note 1: Perform this adjustment only when replacing the lens
block. When the microprocessor, circuit etc. is damaged,
don't perform this adjustment but check the optical axis.
Note 2: When performing this adjustment, place the camcorder
on a level place, and take care not to move the camcorder
during the adjustment.

Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF
3) FOCUS ................................................................... MANUAL
4) STEADY SHOT (Menu setting) ..................................... OFF
5) TV TYPE (Menu setting) ............................................... 16 : 9

HDR-FX7/FX7E_ADJ
6-40
10-1. Optical Axis Adjustment (1) Adjusting method:
Subject Pattern A Order Page Address Data Procedure
(1.2 m from the front of lens) 1 0 01 01
Measurement Point Video terminal of A/V jack 2 6 40 01
Measuring Instrument Oscilloscope (V period) 3 0 10 07
Adjustment Page 7F (Note 1) 4 F 50 00 Press PAUSE (Write) button.
Adjustment Address 50, 51 (7F)
5 F 51 00 Press PAUSE (Write) button.
Note 1: If reading/writing data on pages 7F, set data: 07 to page:
(7F)
0, address: 10, and then select pages: F. By this data set-
ting, the pages 7F can be selected. Set the zoom to TELE end,
6
After the data reading/writing finished, return the data and shoot the pattern A.
on page: 0, address: 10 to “00”. 7 Adjust the focus.
Measure the SV1 (msec),
Pattern A
8 SV2 (msec) and SV3
(msec).(Fig. 6-1-10)
White Set the zoom to WIDE end,
9 and shoot the pattern A.
25 mm Black (Note 2)
10 Adjust the focus. (Note 2)
White
Measure the SV1’ (msec),
11 SV2’ (msec) and SV3’
A0 size (841 x 1189 mm) (msec).(Fig. 6-1-10)
Fig. 6-1-9 12 Calculate D50, D51. (Note 3)
13 F 50 D50 Press PAUSE (Write) button.
SV1 or SV1’
(7F)
14 F 51 D51 Press PAUSE (Write) button.
(7F)
Note 2: Using the adjustment remote commander (HOLD switch
in NOR position), operate the zoom and focus without
touching the camcorder.
Note 3: Calculate D50 and D51 through the procedure given be-
low.
1) Calculate P using following equations. (decimal calculation)
P = (19.6 ÷ 18.6) × (SV2 + SV3) ÷ (SV1 × 2) × 1080
– (1 ÷ 18.6) × (SV2’ + SV3’) ÷ (SV1’ × 2) × 1080 – 540
2) Calculate Vadj using following equations. (decimal calculation)
Vadj = (P ÷ 1080) × 2214 ÷ 0.85 ÷ 0.1831
SV2 or SV2’ 3) Convert Vadj into 4-digit hexadecimal Vadj’ (signed short type),
and assume higher-order 1byte as D50 and lower-order 1byte
SV3 or SV3’
as D51.
If Vadj is a positive value: Convert as it is.
When the zoom at TELE end: SV1, SV2, SV3 (msec)
e.g.: When Vadj = 20
When the zoom at WIDE end: SV1’, SV2’, SV3’ (msec)
Vadj’ = 0014
Fig. 6-1-10 D50 = 00, D51 = 14
If Vadj is a negative value: Add 65536 and then convert it.
e.g.: When Vadj = –20
(–20) + 65536 = 65516
Vadj’ = FFEC
D50 = FF, D51 = EC

Processing after Completing Adjustment:


Order Page Address Data Procedure
1 0 10 00
2 6 40 00
3 0 01 00

HDR-FX7/FX7E_ADJ
6-41
10-2. Optical Axis Adjustment (2) Adjusting method:
Subject Pattern B Order Page Address Data Procedure
(1.2 m from the front of lens) 1 0 01 01
Measurement Point Video terminal of A/V jack 2 6 40 01
Measuring Instrument Oscilloscope (H period) 3 0 10 07
Adjustment Page 7F (Note 1) F
4 52 00 Press PAUSE (Write) button.
Adjustment Address 52, 53 (7F)
Note 1: If reading/writing data on pages 7F, set data: 07 to page: 5 F 53 00 Press PAUSE (Write) button.
0, address: 10, and then select pages: F. By this data set- (7F)
ting, the pages 7F can be selected. Set the zoom to TELE end,
After the data reading/writing finished, return the data 6
and shoot the pattern B.
on page: 0, address: 10 to “00”.
7 Adjust the focus.

Pattern B
Measure the SH1 (µsec), SH2
Black 8 (µsec) and SH3 (µsec). (Fig.
6-1-12)
Set the zoom to WIDE end,
9 and shoot the pattern B.
White

White

(Note 2)
10 Adjust the focus. (Note 2)
Measure the SH1’ (µsec),
11 SH2’ (µsec) and SH3’ (µsec).
25 mm (Fig. 6-1-12)
A0 size (841 x 1189 mm) 12 Calculate D52, D53. (Note 3)
13 F 52 D52 Press PAUSE (Write) button.
Fig. 6-1-11 (7F)
14 F 53 D53 Press PAUSE (Write) button.
SH1 or SH1’ (7F)
Note 2: Using the adjustment remote commander (HOLD switch
in NOR position), operate the zoom and focus without
touching the camcorder.
Note 3: Calculate D52 and D53 through the procedure given be-
low.
1) Calculate Y using following equations. (decimal calculation)
Y = 960 – (19.6 ÷ 18.6) × (SH2 + SH3) ÷ (SH1 × 2) × 1920
+ (1 ÷ 18.6) × (SH2’ + SH3’) ÷ (SH1’ × 2) × 1920
SH2 or
2) Calculate Hadj using following equations. (decimal calculation)
SH2’ Hadj = (Y ÷ 1920) × 3916 ÷ 0.85 ÷ 0.1831
3) Convert Hadj into 4-digit hexadecimal Hadj’ (signed short type),
SH3 or and assume higher-order 1byte as D52 and lower-order 1byte
SH3’ as D53.
When the zoom at TELE end: SH1, SH2, SH3 (µsec) If Hadj is a positive value: Convert as it is.
When the zoom at WIDE end: SH1’, SH2’, SH3’ (µsec) e.g.: When Hadj = 20
Hadj’ = 0014
Fig. 6-1-12 D50 = 00, D51 = 14
If Hadj is a negative value: Add 65536 and then convert it.
e.g.: When Hadj = –20
(–20) + 65536 = 65516
Hadj’ = FFEC
D50 = FF, D51 = EC

Processing after Completing Adjustment:


Order Page Address Data Procedure
1 0 10 00
2 6 40 00
3 0 01 00

HDR-FX7/FX7E_ADJ
6-42
10-3. Optical Axis Check
Subject Pattern C
(1.2 m from the front of lens)
Measurement Point Video terminal of A/V jack
Measuring Instrument TV monitor
Specified value Below 8%

Pattern C

10 mm

Black
White

A4 size (210 x 297 mm)

Fig. 6-1-13

Adjusting method:
Order Page Address Data Procedure
1 0 01 01
2 6 40 01
Set the zoom to TELE end,
3
and shoot the pattern C.
Adjust the camcorder
4 direction so that a dot in the
pattern C is displayed in the
center of monitor screen.
Set the zoom to WIDE end,
5 and shoot the pattern C.
(Note 1)
Measure the moving amount
of a dot (difference in
6 position between TELE end
and WIDE end), and assume
it as C (mm).
Measure vertical length of
7 the monitor screen, and
assume it as H (mm).
Make sure that C is within
8 8% of H. (Note 2)
Note 1: Using the adjustment remote commander (HOLD switch
in HOR position), operate the zoom and focus without
touching the camcorder.
Note 2: If out of specification, perform readjustment.

Processing after Completing Adjustment:


Order Page Address Data Procedure
1 6 40 00
2 0 01 00

HDR-FX7/FX7E_ADJ
6-43
11. Picture Frame Setting How to reset the zoom and focus when they deviated:
(Color reproduction adjustment frame) If the zoom and focus deviated due to some reason, reset them in
the following method.
Subject Color bar chart
(Color reproduction adjustment Order Page Address Data Procedure
frame) 1 6 40 01
40 cm (PTB-1450) from the front of
lens) 2 6 90 XL

Measurement Point Video terminal of A/V jack 3 6 91 XH


(75 Ω terminated) 4 6 92 YL
Measuring Instrument Oscilloscope and monitor TV (16:9) 5 6 93 YH
Specified Value A=B, C=D, E=F 6 6 01 79 Press PAUSE (Write) button.
Note 1: Perform “Hall Adjustment” and “Flange Back Adjust-
ment” before this adjustment. How to release the picture frame setting:
Note 2: Check that the data of page: 0, address: 10 is “00”.
Order Page Address Data Procedure
Switch setting 1 6 40 00
1) POWER ......................................................... CAMERA mode 2 6 01 00 Press PAUSE (Write) button.
2) FOCUS ................................................................... MANUAL 3 6 90 00
3) D.EXTENDER (Menu setting) ....................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF 4 6 91 00
5) REC FORMAT (Menu setting) ............................. HDV1080i 5 6 92 00
6 6 93 00
Setting method:
Order Page Address Data Procedure
Check on the oscilloscope
1 6 40 01 1. Horizontal period
Adjust the zoom and the
A B C D
2 camera direction, and set the
A=B C=D
specified position.
Mark the position of the
picture frame on the monitor
TV, and adjust the picture
H
3 frame to this position in
following adjustment using
Fig. 6-1-14
“Color reproduction
adjustment frame”.
2. Vertical period

How to read the XH, XL, YH and YL data: E E=F=0 F


Order Page Address Data Procedure
1 0 03 18

2 1 Read XH data and XL data.


(Note 3)
V
3 0 03 22

4 1 Read YH data and YL data. Fig. 6-1-15


(Note 3)
Note 3: The right four digits of the page: 1 displayed data of the Check on the monitor TV (Underscanned mode)
adjusting remote commander.
1:XX : XX A=B C=D
A B C D
XL or YL data E
XH or YH data

E=F=0

Color bar chart picture frame Monitor TV picture frame

Fig. 6-1-16

HDR-FX7/FX7E_ADJ
6-44
12. Linearity Adjustment Order Page Address Data Procedure
Correct the linearity of AFE (analog Front End).
11 0 10 00
Subject Clear chart
12 6 CA 07
(Color reproduction adjustment
13 6 15 92
frame)
14 6 01 0B Press PAUSE (Write) button.
Adjustment Page 6E
Check the data changes to
Adjustment Address F0 to F7 15 6 02
“01”.
Note 1: If reading/writing data on pages 6E, set data: 06 to page: 16 6 01 00 Press PAUSE (Write) button.
0, address: 10, and then select pages: E. By this data set-
ting, the pages 6E can be selected. 17 6 C9 10
After the data reading/writing finished, return the data 18 0 10 0C
on page: 0, address: 10 to “00”. D
Note 2: Check that the data of page: 6, address: 02 is “00”. 19 0E 0F Press PAUSE (Write) button.
(CD)
If not, select page: 6, address: 01, set data: 00, and press
20 0 10 00
PAUSE (Write) button.
21 6 14 87
Switch setting 22 6 9D 10
1) POWER ......................................................... CAMERA mode
23 0 03 29
2) ND FILTER ............................................................................ 2
3) REC FORMAT (Menu setting) ............................. HDV1080i 24 0 10 0A
4) STEADY SHOT (Menu setting) ..................................... OFF Set the bit value of bit6 is “1”,
5) D. EXTENDER (Menu setting) ...................................... OFF F
25 1E and press PAUSE (Write)
(AF)
button. (Note 3)
Address
F0 F1 F2 F3 F4 F5 F6 F7 26 0 10 06
Type
From Table 6-1-2, set the type
A 00 00 00 00 00 00 00 00 E
27 F0 to F7 A data, and press PAUSE
(6E)
B E1 E1 EE F2 F6 FA FC FD (Write) button.
C C2 C2 DC E4 EB F3 F7 F9 28 0 10 00
D A3 A3 C9 D6 E1 EC F2 F5 29 6 01 0F Press PAUSE (Write) button.
E 83 83 B7 C8 D6 E5 ED F2 Check the data changes to
30 6 02
F 80 80 A5 BA CB DE E8 EE “01”.

G 80 80 92 AC C1 D7 E4 EA Read the displayed data


31 1
(Note 4) and write it down.
Table 6-1-2 For the type B to type G,
32 perform order 26 - 31, same
Adjusting method: as type A.
Order Page Address Data Procedure Select the type of which data
1 0 01 01 33 read in the order 31 is nearest
to 0. (Note 5, 6)
2 0 10 0A
34 0 10 06
3 E
8C 01 Press PAUSE (Write) button. Set the data of the type
(AE) E
35 F0 to F7 selected in the order 33 and
4 0 10 06 (6E)
press PAUSE button.
F
5 90 Note down the data. 36 0 10 00
(6F)
F Note 3: For the bit values, refer to “6-4. SERVICE MODE”, “4-
6 91 Note down the data. 3. 3. Bit value discrimination”.
(6F)
Note 4: The upper two digits of the page: 1 displayed data of the
F adjusting remote commander (RM-95).
7 92 Note down the data.
(6F) 1 : XX : XX
F Displayed data
8 93 Note down the data.
(6F) Read the “Data Section” of adjustment remote com-
D mander (New LANC jig).
9 5E Note down the data. P : 01 a: XX d: XX
(6D)
Data Section
D
10 5E 5C Press PAUSE (Write) button. Note 5: Data is displayed in the signed chart form. (Data: FF
(6D)
becomes –1.)
Note 6: If there are multiple types of which data is nearest to 0,
select the type in the center.

HDR-FX7/FX7E_ADJ
6-45
Processing after Completing Adjustment:
Order Page Address Data Procedure
1 6 01 00 Press PAUSE (Write) button.
2 0 10 06

F Set data noted down at step 5,


3 90 and press PAUSE (Write)
(6F)
button.

F Set data noted down at step 6,


4 91 and press PAUSE (Write)
(6F)
button.

F Set data noted down at step 7,


5 92 and press PAUSE (Write)
(6F)
button.

F Set data noted down at step 8,


6 93 and press PAUSE (Write)
(6F)
button.

D Set data noted down at step 9,


7 5E and press PAUSE (Write)
(6D)
button.
8 0 10 0C
D
9 90 Press PAUSE (Write) button.
(CD)
10 0 10 00
11 6 14 00
12 6 15 00
13 6 9D 00
14 6 C9 00
15 6 CA 00
16 6 40 00
17 6 41 00
18 0 10 0A
E
19 8C 00 Press PAUSE (Write) button.
(AE)

F Set the bit value of bit6 is


20 1E “0”, and press PAUSE
(AF)
(Write) button. (Note 3)
21 0 10 00
22 0 03 00
23 0 01 00

HDR-FX7/FX7E_ADJ
6-46
Ver. 1.4 2008.06

13. Picture Frame Setting (Center frame) 14. F No. & ND Light Quality Standard Data Input
Subject Clear chart (Center frame) RadarW
40 cm (PTB-1450) from the front of Correct the lens iris and dispersion of the ND filter light quantity.
lens)
Subject Clear chart (Center frame)
Measurement Point Video terminal of A/V jack (75 Ω
Adjustment Page 6D
terminated)
Adjustment Address 60 to 6F
Measuring Instrument Monitor TV
Specified Value A clear chart must be shot in larger Note 1: Perform “LV Standard Data Input” after this adjustment.
size than nine grids in the center of Note 2: If reading/writing data on pages 6D, set data: 06 to page:
frame shown on the screen. 0, address: 10, and then select pages: D. By this data
(Fig. 6-1-17) setting, the pages 6D can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Switch setting Note 3: Check that the data of page: 6, address: 02 is “00”.
1) POWER ......................................................... CAMERA mode If not, select page: 6, address: 01, set data: 00, and press
2) FOCUS ................................................................... MANUAL PAUSE (Write) button.
3) ZOOM .................................................................... WIDE end
4) D. EXTENDER (Menu setting) ...................................... OFF Switch setting
5) STEADY SHOT (Menu setting) ..................................... OFF 1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF
Setting method: 3) FOCUS ................................................................... MANUAL
Order Page Address Data Procedure 4) ZOOM .................................................................... WIDE end
5) REC FORMAT (Menu setting) ............................. HDV1080i
Shoot a clear chart in the 6) STEADY SHOT (Menu setting) ..................................... OFF
1 center of screen with the 7) D. EXTENDER (Menu setting) ...................................... OFF
zoom at WIDE end.
2 0 01 01 Adjusting method:
3 0 10 09 Order Page Address Data Procedure
4 F 4A 08 Press PAUSE (Write) button. Check that the picture frame
(9F) is “Center Frame”. If not,
1
F Perform “13. Picture Frame
5 4B 81 Press PAUSE (Write) button.
(9F) Setting (Center Frame)”
Check that a clear chart is 2 0 01 01
shot in larger size than nine 3 6 17 10
6
grids in the center of frame
4 6 C9 10
shown on the screen.
5 6 10 80
7 F 4A 00 Press PAUSE (Write) button.
(9F) 6 6 D2 C0
F 7 6 D3 40
8 4B 00 Press PAUSE (Write) button.
(9F) Press PAUSE button. (Note
8 6 01 BB
9 0 10 00 4)
10 0 01 00 Check the data changes to
9 6 02
“01”.
In the following adjustment,
if the “Center frame” is used, 10 6 0C Check the data is “00”.
11
adjust the clear chart to this Note 4: The adjustment data will be automatically input to page:
position. 6D, address: 60 to 6F.

Processing after Completing Adjustment:


Order Page Address Data Procedure
1 6 17 00
2 6 C9 00
3 6 10 00
4 6 01 00 Press PAUSE button.
5 0 01 00

A clear chart must be shot in larger size


than central nine grids.

Fig.6-1-17

HDR-FX7/FX7E_ADJ
6-47
15. Linear Matrix Adjustment (1) RadarW 16. Linear Matrix Adjustment (2) RadarW
Adjust the matrix coefficient for compensating the variation in Adjust the matrix coefficient for compensating the variation in
spectral sensitivity. spectral sensitivity.
Adjustment Page 6D Adjustment Page 6F
Adjustment Address B0 to F7 Adjustment Address 60 to 71

Adjusting method: Adjusting method:


1) Select page: 0, address: 01, and set data: 01. 1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 06. 2) Select page: 0, address: 10, and set data: 06.
3) Input the following data to page: D (6D), address: B0 to F7. 3) Input the following data to page: F (6F), address: 60 to 71.
Note: Press the PAUSE (Write) button of the adjustment remote com- Note: Press the PAUSE (Write) button of the adjustment remote com-
mander each time to set data. mander each time to set data.

Address Data Address Data Address Data


B0 03 D4 04 60 20
B1 FD D5 01 61 2D
B2 FF D6 FF 62 00
B3 F8 D7 FA 63 33
B4 00 D8 FF 64 FE
B5 13 D9 E8 65 E9
B6 00 DA FF 66 00
B7 25 DB F5 67 0E
B8 03 DC 04 68 1F
B9 E7 DD 3E 69 7E
BA FF DE FF 6A 01
BB EB DF AD 6B 6C
BC FF E0 00 6C 00
BD FA E1 07 6D 2F
BE 00 E2 00 6E FF
BF 0A E3 02 6F F6
C0 03 E4 04 70 1F
C1 EC E5 2E 71 9F
C2 04 E6 05 4) Select page: 0, address: 10, and set data: 00.
C3 02 E7 9D 5) Select page: 0, address: 01, and set data: 00.
C4 00 E8 FF
C5 0A E9 02
C6 FF EA 00
C7 EE EB 0D
C8 FF EC FF
C9 DC ED E0
CA 04 EE 04
CB 19 EF B6
CC 00 F0 FF
CD 17 F1 1C
CE 00 F2 FF
CF 08 F3 F1
D0 FF F4 FF
D1 F7 F5 F3
D2 04 F6 04
D3 14 F7 21
4) Select page: 0, address: 10, and set data: 00.
5) Select page: 0, address: 01, and set data: 00.

HDR-FX7/FX7E_ADJ
6-48
17. Auto White Balance Standard Data Input 18. Auto White Balance Standard Data Input
(ND OFF) RadarW (ND 1) RadarW
Adjust the white balance reference at 3200K, and adjust the nor- Adjust the white balance reference at 3200K, and adjust the nor-
mal coefficient of the light value. mal coefficient of the light value.
Subject Clear chart (Color reproduction Subject Clear chart (Color reproduction
adjustment frame) adjustment frame)
Adjustment Page 6F Adjustment Page 6F
Adjustment Address 88 to 8B Adjustment Address 8C to 8F
Note 1: If reading/writing data on pages 6F, set data: 06 to page: Note 1: If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set- 0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected. ting, the pages 6F can be selected.
After the data reading/writing finished, return the data After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”. on page: 0, address: 10 to “00”.
Note 2: Check that the data of page: 6, address: 02 is “00”. If Note 2: Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button. PAUSE (Write) button.

Switch setting Switch setting


1) POWER ......................................................... CAMERA mode 1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF 2) ND FILTER ............................................................................ 1
3) D.EXTENDER (Menu setting) ....................................... OFF 3) D.EXTENDER (Menu setting) ....................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF 4) STEADY SHOT (Menu setting) ..................................... OFF
5) REC FORMAT (Menu setting) ............................. HDV1080i 5) REC FORMAT (Menu setting) ............................. HDV1080i

Adjusting method: Adjusting method:


Order Page Address Data Procedure Order Page Address Data Procedure
1 0 01 01 1 0 01 01
2 0 10 0A 2 0 10 0A
E E
3 8C 01 Press PAUSE (Write) button. 3 8C 01 Press PAUSE (Write) button.
(AE) (AE)
4 0 10 00 4 0 10 00
Press PAUSE (Write) button. Press PAUSE (Write) button.
5 6 01 0B 5 6 01 0B
(Note 3) (Note 3)
Check the data changes to Check the data changes to
6 6 02 6 6 02
“01”. “01”.
Note 3: The adjustment data will be automatically input to page: Note 3: The adjustment data will be automatically input to page:
6F, address: 88 to 8B. 6F, address: 8C to 8F.

Processing after Completing Adjustment: Processing after Completing Adjustment:


Order Page Address Data Procedure Order Page Address Data Procedure
1 6 01 00 Press PAUSE (Write) button. 1 6 01 00 Press PAUSE (Write) button.
2 0 10 0A 2 0 10 0A
E E
3 8C 00 Press PAUSE (Write) button. 3 8C 00 Press PAUSE (Write) button.
(AE) (AE)
4 0 10 00 4 0 10 00
5 0 01 00 5 0 01 00

HDR-FX7/FX7E_ADJ
6-49
19. Auto White Balance Standard Data Input 20. LV Standard Data Input
(ND 2) RadarW Adjust the normal coefficient of the light value at 3200K.
Adjust the white balance reference at 3200K, and adjust the nor-
Subject Clear chart (Color reproduction
mal coefficient of the light value.
adjustment frame)
Subject Clear chart (Color reproduction Measurement Point Adjusting remote commander
adjustment frame)
Measuring Instrument
Adjustment Page 6F
Adjustment Page 6D
Adjustment Address 90 to 93
Adjustment Address 5C, 5D
Note 1: If reading/writing data on pages 6F, set data: 06 to page: Specified Value Data of page: 6 address: 0C is “00”
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected. Note 1: Perform “Auto White Balance Standard Data Input” be-
After the data reading/writing finished, return the data fore this adjustment.
on page: 0, address: 10 to “00”. Note 2: If reading/writing data on pages 6D, set data: 06 to page:
Note 2: Check that the data of page: 6, address: 02 is “00”. If 0, address: 10, and then select pages: D. By this data
not, select page: 6, address: 01, set data: 00, and press setting, the pages 6D can be selected.
PAUSE (Write) button. After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Switch setting Note 3: Check that the data of page: 6, address: 02 is “00”.
1) POWER ......................................................... CAMERA mode If not, select page: 6, address: 01, set data: 00, and press
2) ND FILTER ............................................................................ 2 PAUSE (Write) button.
3) D.EXTENDER (Menu setting) ....................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF Switch setting
5) REC FORMAT (Menu setting) ............................. HDV1080i 1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF
Adjusting method: 3) D. EXTENDER (Menu setting) ...................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
Order Page Address Data Procedure 5) REC FORMAT (Menu setting) ............................. HDV1080i
1 0 01 01
2 0 10 0A Adjusting method:
E Order Page Address Data Procedure
3 8C 01 Press PAUSE (Write) button.
(AE) 1 0 01 01
4 0 10 00 2 6 C9 10
Press PAUSE (Write) button. Press PAUSE (Write) button.
5 6 01 0B 3 6 01 0D
(Note 3) (Note 4)
Check the data changes to Check the data changes to
6 6 02 4 6 02
“01”. “01”.
Note 3: The adjustment data will be automatically input to page: 5 6 0C Check the data is “00”.
6F, address: 90 to 93.
Note 4: The adjustment data will be automatically input to page:
Processing after Completing Adjustment: 6D, address: 5C, 5D.

Order Page Address Data Procedure Processing after Completing Adjustment:


1 6 01 00 Press PAUSE (Write) button. Order Page Address Data Procedure
2 0 10 0A 1 6 01 00 Press PAUSE (Write) button.
E 2 6 C9 00
3 8C 00 Press PAUSE (Write) button.
(AE)
3 0 01 00
4 0 10 00
5 0 01 00

HDR-FX7/FX7E_ADJ
6-50
21. Auto White Balance Adjustment (ND OFF) RadarW Adjusting method:
Adjust to the proper auto white balance output data.
Order Page Address Data Procedure
If it is not correct, auto white balance and color reproducibility
will be poor. 1 Place the C14 filter on the
lens.
Subject Clear chart
(Color reproduction adjustment 2 0 01 01
frame) 3 0 10 0A
Filter Filter C14 for color temperature 4 E 8C 01 Press PAUSE (Write) button.
correction (AE)
Adjustment Page 6F 5 0 10 06
Adjustment Address 84 to 87, 98 to 9B 6 F 84 2B Press PAUSE (Write) button.
(6F)
Note 1: Perform “F No. & ND Light Quality Standard Data In-
put” and “Auto White Balance Standard Data Input” be- 7 F 85 D7 Press PAUSE (Write) button.
fore this adjustment. (6F)
Note 2: If reading/writing data on pages 6F, set data: 06 to page: F
8 86 5D Press PAUSE (Write) button.
0, address: 10, and then select pages: F. By this data set- (6F)
ting, the pages 6F can be selected. F
After the data reading/writing finished, return the data 9 87 DC Press PAUSE (Write) button.
(6F)
on page: 0, address: 10 to “00”.
Note 3: Check that the data of page: 6, address: 02 is “00”. If 10 0 10 00
not, select page: 6, address: 01, set data: 00, and press Press PAUSE (Write) button.
11 6 01 81
PAUSE (Write) button. (Note 4)

12 6 02 Check the data changes to


Switch setting “01”.
1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF Note 4: The adjustment data will be automatically input to page:
3) D. EXTENDER (Menu setting) ...................................... OFF 6F, address: 98 to 9B.
4) STEADY SHOT (Menu setting) ..................................... OFF
5) REC FORMAT (Menu setting) ............................. HDV1080i Processing after Completing Adjustment:
Order Page Address Data Procedure
1 6 01 00 Press PAUSE (Write) button.
2 0 10 0A

3 E 8C 00 Press PAUSE (Write) button.


(AE)
4 0 10 00
5 0 01 00

6 Remove the C14 filter on the


lens.

HDR-FX7/FX7E_ADJ
6-51
22. Auto White Balance Adjustment (ND 1) RadarW 23. Auto White Balance Adjustment (ND 2) RadarW
Adjust to the proper auto white balance output data. Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility If it is not correct, auto white balance and color reproducibility
will be poor. will be poor.
Subject Clear chart Subject Clear chart
(Color reproduction adjustment (Color reproduction adjustment
frame) frame)
Filter Filter C14 for color temperature Filter Filter C14 for color temperature
correction correction
Adjustment Page 6F Adjustment Page 6F
Adjustment Address 9C to 9F Adjustment Address A0 to A3
Note 1: Perform “F No. & ND Light Quality Standard Data In- Note 1: Perform “F No. & ND Light Quality Standard Data In-
put” and “Auto White Balance Standard Data Input” be- put” and “Auto White Balance Standard Data Input” be-
fore this adjustment. fore this adjustment.
Note 2: If reading/writing data on pages 6F, set data: 06 to page: Note 2: If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set- 0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected. ting, the pages 6F can be selected.
After the data reading/writing finished, return the data After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”. on page: 0, address: 10 to “00”.
Note 3: Check that the data of page: 6, address: 02 is “00”. If Note 3: Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button. PAUSE (Write) button.

Switch setting Switch setting


1) POWER ......................................................... CAMERA mode 1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 1 2) ND FILTER ............................................................................ 2
3) D. EXTENDER (Menu setting) ...................................... OFF 3) D. EXTENDER (Menu setting) ...................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF 4) STEADY SHOT (Menu setting) ..................................... OFF
5) REC FORMAT (Menu setting) ............................. HDV1080i 5) REC FORMAT (Menu setting) ............................. HDV1080i

Adjusting method: Adjusting method:


Order Page Address Data Procedure Order Page Address Data Procedure
Place the C14 filter on the Place the C14 filter on the
1 1
lens. lens.
2 0 01 01 2 0 01 01
3 0 10 0A 3 0 10 0A
E E
4 8C 01 Press PAUSE (Write) button. 4 8C 01 Press PAUSE (Write) button.
(AE) (AE)
5 0 10 00 5 0 10 00
Press PAUSE (Write) button. Press PAUSE (Write) button.
6 6 01 81 6 6 01 81
(Note 4) (Note 4)
Check the data changes to Check the data changes to
7 6 02 7 6 02
“01”. “01”.
Note 4: The adjustment data will be automatically input to page: Note 4: The adjustment data will be automatically input to page:
6F, address: 9C to 9F. 6F, address: A0 to A3.

Processing after Completing Adjustment: Processing after Completing Adjustment:


Order Page Address Data Procedure Order Page Address Data Procedure
1 6 01 00 Press PAUSE (Write) button. 1 6 01 00 Press PAUSE (Write) button.
2 0 10 0A 2 0 10 0A
E E
3 8C 00 Press PAUSE (Write) button. 3 8C 00 Press PAUSE (Write) button.
(AE) (AE)
4 0 10 00 4 0 10 00
5 0 01 00 5 0 01 00
Remove the C14 filter on the Remove the C14 filter on the
6 6
lens. lens.

HDR-FX7/FX7E_ADJ
6-52
24. Color Reproduction Adjustment (ND OFF) RadarW 25. Color Reproduction Adjustment (ND 1) RadarW
Adjust the color separation matrix coefficient so that proper color Adjust the color separation matrix coefficient so that proper color
reproduction is produced. reproduction is produced.
Subject Color bar chart Subject Color bar chart
(Color reproduction adjustment (Color reproduction adjustment
frame) frame)
Adjustment Page 6F Adjustment Page 6D
Adjustment Address A8 to C7 Adjustment Address 70 to 8F
Note 1: If reading/writing data on pages 6F, set data: 06 to page: Note 1: If reading/writing data on pages 6D, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set- 0, address: 10, and then select pages: D. By this data
ting, the pages 6F can be selected. setting, the pages 6D can be selected.
After the data reading/writing finished, return the data After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”. on page: 0, address: 10 to “00”.
Note 2: Check that the data of page: 6, address: 02 is “00”. If Note 2: Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button. PAUSE (Write) button.

Switch setting Switch setting


1) POWER ......................................................... CAMERA mode 1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF 2) ND FILTER ............................................................................ 1
3) D. EXTENDER (Menu setting) ...................................... OFF 3) D. EXTENDER (Menu setting) ...................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF 4) STEADY SHOT (Menu setting) ..................................... OFF
5) REC FORMAT (Menu setting) ............................. HDV1080i 5) REC FORMAT (Menu setting) ............................. HDV1080i

Adjusting method: Adjusting method:


Order Page Address Data Procedure Order Page Address Data Procedure
1 0 01 01 1 0 01 01
2 0 10 0A 2 0 10 0A
E E
3 8C 01 Press PAUSE (Write) button. 3 8C 01 Press PAUSE (Write) button.
(AE) (AE)
4 0 10 00 4 0 10 00
5 6 C9 10 5 6 C9 10
6 6 CA 04 6 6 CA 04
7 6 D0 49 7 6 D0 48
Press PAUSE (Write) button. Press PAUSE (Write) button.
8 6 01 61 8 6 01 61
(Note 3) (Note 3)
Check the data changes to Check the data changes to
9 6 02 9 6 02
“01”. “01”.
Note 3: The adjustment data will be automatically input to page: Note 3: The adjustment data will be automatically input to page:
6F, address: A8 to C7. 6D, address: 70 to 8F.

Processing after Completing Adjustment: Processing after Completing Adjustment:


Order Page Address Data Procedure Order Page Address Data Procedure
1 6 01 00 Press PAUSE button. 1 6 01 00 Press PAUSE button.
2 6 C9 00 2 6 C9 00
3 6 CA 00 3 6 CA 00
4 0 10 0A 4 0 10 0A
E E
5 8C 00 Press PAUSE (Write) button. 5 8C 00 Press PAUSE (Write) button.
(AE) (AE)
6 0 10 00 6 0 10 00
7 0 01 00 7 0 01 00

HDR-FX7/FX7E_ADJ
6-53
Ver. 1.1 2007.05

26. Color Reproduction Adjustment (ND 2) RadarW 27. MAX GAIN Adjustment RadarW
Adjust the color separation matrix coefficient so that proper color Setting the minimum illumination.
reproduction is produced. If it is not consistent, the image level required for taking subjects
in low illuminance will not be produced (dark).
Subject Color bar chart
(Color reproduction adjustment Subject Clear chart (Center frame)
frame) Adjustment Page 6D
Adjustment Page 6D Adjustment Address 5E
Adjustment Address 90 to AF
Note 1: Perform “Flange Back Adjustment” before this adjust-
Note 1: If reading/writing data on pages 6D, set data: 06 to page: ment.
0, address: 10, and then select pages: D. By this data Note 2: If reading/writing data on pages 6D, set data: 06 to page:
setting, the pages 6D can be selected. 0, address: 10, and then select pages D. By this data set-
After the data reading/writing finished, return the data ting, the pages 6D can be selected.
on page: 0, address: 10 to “00”. After the data reading/writing finished, return the data
Note 2: Check that the data of page: 6, address: 02 is “00”. If on page: 0, address: 10 to “00”.
not, select page: 6, address: 01, set data: 00, and press Note 3: Check that the data of page: 6, address: 02 is “00”. If
PAUSE (Write) button. not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode Switch setting
2) ND FILTER ............................................................................ 2 1) POWER ......................................................... CAMERA mode
3) D. EXTENDER (Menu setting) ...................................... OFF 2) ND FILTER ...................................................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF 3) FOCUS ................................................................... MANUAL
5) REC FORMAT (Menu setting) ............................. HDV1080i 4) ZOOM .................................................................... WIDE end
5) D. EXTENDER (Menu setting) ...................................... OFF
Adjusting method: 6) STEADY SHOT (Menu setting) ..................................... OFF
7) REC FORMAT (Menu setting) ............................. HDV1080i
Order Page Address Data Procedure
1 0 01 01 Adjusting method:
2 0 10 0A Order Page Address Data Procedure
E Check that the picture frame
3 8C 01 Press PAUSE (Write) button.
(AE) is “Center Frame”. If not,
1
4 0 10 00 perform “23. Picture Frame
5 6 15 86 Setting (Center Frame)”
6 6 C9 10 2 0 01 01
7 6 CA 04 3 6 C9 10
8 6 D0 47 Set the following data
4 6 D0 2A:NTSC model
Press PAUSE (Write) button.
9 6 01 61 14: PAL model
(Note 3)
Set the following data
Check the data changes to
10 6 02 5 6 D1 00: NTSC model
“01”.
80: PAL model
Note 3: The adjustment data will be automatically input to page: Press PAUSE (Write) button.
6D, address: 90 to AF. 6 6 01 6F
(Note 4)

7 6 02 Check the data changes to


Processing after Completing Adjustment:
“01”.
Order Page Address Data Procedure
Note 4: The adjustment data will be automatically input to page:
1 6 01 00 Press PAUSE button. 6D, address: 5E.
2 6 C9 00
3 6 CA 00 Processing after Completing Adjustment:

4 6 15 00 Order Page Address Data Procedure


5 0 10 0A 1 6 C9 00
E 2 6 01 00 Press PAUSE (Write) button.
6 8C 00 Press PAUSE (Write) button.
(AE) 3 0 01 00
7 0 10 00
8 0 01 00

HDR-FX7/FX7E_ADJ
6-54
28. White Defect & HS Defect Adjustment RadarW 29. White Defect Adjustment (FD white point) RadarW
Detect white defective pixels of CMOS image sensor. Detect white defective pixels (FD white point) of CMOS image
sensor.
Subject Not required
Measurement Point Adjusting remote commander Subject Not required
Measuring Instrument Note 1: Perform “White Defect & HS Defect Adjustment” be-
Specified value Data of page: 6 address: D3 is “00” fore this adjustment.
Note 2: Check that the data of page: 0, address: 10 is “00”.
Note 1: Perform “Auto White Balance Adjustment” before this Note 3: Check that the data of page: 6, address: 02 is “00”.
adjustment. If not, select page: 6, address: 01, set data: 00, and press
Note 2: Check that the data of page: 0, address: 10 is “00”. PAUSE (Write) button.
Note 3: Check that the data of page: 6, address: 02 is “00”.
If not, select page: 6, address: 01, set data: 00, and press Switch setting
PAUSE (Write) button. 1) POWER ......................................................... CAMERA mode

Switch setting Adjusting method:


1) POWER ......................................................... CAMERA mode
Order Page Address Data Procedure
Adjusting method: 1 0 01 01
Order Page Address Data Procedure 2 6 07 Check the data is “04”.
1 0 01 01 3 6 D0 0C
2 6 07 Check the data is “04”. 4 6 01 21 Press PAUSE (Write) button.
3 6 D0 06 5 6 02 Check the data changes to
“01”.
4 6 01 21 Press PAUSE (Write) button.

5 6 02 Check the data changes to


Processing after Completing Adjustment:
“01”.
6 6 D3 Check the data is “00”. Order Page Address Data Procedure
1 6 01 00 Press PAUSE (Write) button.
Processing after Completing Adjustment: 2 0 01 00
Order Page Address Data Procedure
1 6 01 00 Press PAUSE (Write) button.
2 0 01 00

HDR-FX7/FX7E_ADJ
6-55
30. White Defect Check RadarW 31. Black Defect Adjustment RadarW
Detect black defective pixels of CMOS image sensor.
Subject Not required
Measurement Point Adjusting remote commander Subject Clear chart (All white) (Note 1)
Measuring Instrument Note 1: Shoot the clear chart with the zoom TELE end.
Specified value 1 Data of page: 6 address: D1 is “00” Note 2: Perform “White Defect Check” before this adjustment.
Note 3: Check that the data of page: 0, address: 10 is “00”.
Specified value 2 Data of page: 6, address: D2 is “00” Note 4: Check that the data of page: 6, address: 02 is “00”.
to “05” If not, select page: 6, address: 01, set data: 00, and press
Note 1: Perform “White Defect Adjustment (FD white point)” PAUSE (Write) button.
before this adjustment.
Note 2: Check that the data of page: 0, address: 10 is “00”. Switch setting
Note 3: Check that the data of page: 6, address: 02 is “00”. 1) POWER ......................................................... CAMERA mode
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button. Adjusting method:
Order Page Address Data Procedure
Switch setting
1 0 01 01
1) POWER ......................................................... CAMERA mode
2 6 07 Check the data is “04”
Adjusting method: 3 6 2C 01
Order Page Address Data Procedure 4 6 90 00
1 0 01 01 5 6 91 04
2 6 07 Check the data is “04”. 6 6 92 00
3 6 D0 04 7 6 93 10
4 6 01 21 Press PAUSE (Write) button. 8 6 01 79 Press PAUSE (Write) button.

5 6 02 Check the data changes to 9 Wait for 1 second.


“01”. Check that the entire screen
10
6 6 D1 Check the data is “00”. is white.

7 6 D2 Check the data is “00” to 11 6 D0 01


“05”. 12 6 01 21 Press PAUSE (Write) button.

13 6 02 Check the data changes to


Processing after Completing Adjustment: “01”.
Order Page Address Data Procedure
1 6 01 00 Press PAUSE (Write) button. Processing after Completing Adjustment:
2 0 01 00 Order Page Address Data Procedure
1 6 01 00 Press PAUSE (Write) button.
2 6 90 00
3 6 91 00
4 6 92 00
5 6 93 00
6 6 01 79 Press PAUSE (Write) button.
7 Wait for 1 second.
8 6 01 00 Press PAUSE (Write) button.
9 6 2C 00
10 0 01 00

HDR-FX7/FX7E_ADJ
6-56
32. Angular Velocity Sensor Sensitivity Adjustment
• Perform the angular velocity sensor sensitivity adjustment only
when replacing the angular velocity sensor or lens block. When
the microprocessor, circuit, etc. malfunctions, do not perform
this adjustment but check operations only.
• Record the sensitivity label of the angular velocity sensor (re-
pair part), including to which side of the board it was attached
to, etc. If it has been attached incorrectly, the image will move
up and down or to the left and right during steady shot opera-
tion. Be sure to take note of this.

Precautions on the Parts Replacement


There are two types of repair parts.
Type A ENC03RC
Type B ENC03RD
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations. After replacing,
readjust according to the adjusting method after replacement.

Precautions on Angular Velocity Sensor


The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.

HDR-FX7/FX7E_ADJ
6-57
Ver. 1.4 2008.06

32-1. Angular Velocity Sensor Sensitivity Adjustment (1) Preparation:


1) Read the PITCH sensor (SE8001 of JJ-004 board) sensitivity
Subject Pattern A
written on repair parts, and named this as S12.
(1.5 m from the front of lens)
Measurement Point Video terminal of A/V jack
JJ-004 BOARD (SIDE A)
Measuring Instrument Oscilloscope (V period)
Adjustment Page 7F (Note 1)

2
Adjustment Address 12

SE8002

YY
3
Note 1: If reading/writing data on pages 7F, set data: 07 to page: 4

0, address: 10, and then select pages: F. By this data set-


ting, the pages 7F can be selected.
PP

1
1 2
After the data reading/writing finished, return the data SE8001
on page: 0, address: 10 to “00”.
Note 2: The PITCH sensor (SE8001 of JJ-004 board) sensitivity
is labeled only the repair parts. PITCH sensor
sensitivity t S12
Switch setting
1) POWER ......................................................... CAMERA mode YAW sensor
2) ND FILTER ...................................................................... OFF sensitivity t S13
3) ZOOM ..................................................................... TELE end
How to read the sensitivity data of angular velocity sen-
sor
Pattern A
With the pins 1 and 2 of angular velocity sensor placed in the
lower position, read the data value.
White
Description example :
For the sensor sensitivity value 60
Black
4 3
White

A4 size (297 x 210 mm) 6 0


Fig. 6-1-18 1 2

Hand Writing

HDR-FX7/FX7E_ADJ
6-58
Adjusting method:
Order Page Address Data Procedure V
1 0 01 01
2 Set the zoom to TELE end,
and shoot the pattern A.
3 Adjust the focus.
4 0 10 07
D
5 (7D) 46 F0 Press PAUSE (Write) button.
D Press PAUSE (Write) button.
6 (7D) 48 01 (Note 5)
Measure the falling edge of
7 waveform, SV1 (msec).
Falling edge of Falling edge of
(Fig. 6-1-19) waveform when waveform when
D data is “F0” data is “10”
8 (7D) 48 00 Press PAUSE (Write) button.
D
9 (7D) 46 10 Press PAUSE (Write) button.
SV2–SV1
D Press PAUSE (Write) button.
10 (7D) 48 01 (Note 5) SV2 (msec)
SV1 (msec)
Measure the falling edge of
11 waveform, SV2 (msec).
(Fig. 6-1-19) Fig. 6-1-19
D
12 (7D) 48 00 Press PAUSE (Write) button.
Calculate D12’ using
following equations.
(decimal calculation)
13 (Note 3)
D12’ = ((SV2 – SV1) ÷ 13.8)
× S12 × 61
Convert D12’ to a hexadeci-
14 mal number, and obtain D12.
(Note 4)
F
15 (7F) 12 D12 Press PAUSE (Write) button.
16 0 10 00
Note 3: S12 is read in “Preparation”.
Note 4: Refer to table 6-4-1. “Hexadecimal-decimal conversion
table”.
Note 5: Finish this operation within 10 seconds. If it is likely to
take more than 10 seconds, set page: D (7D), address:
48, data: 00, and then retry.

Processing after Completing Adjustment:


Order Page Address Data Procedure
1 0 01 00
Check that the steady shot
2
function operates normally.

HDR-FX7/FX7E_ADJ
6-59
Ver. 1.4 2008.06

32-2. Angular Velocity Sensor Sensitivity Adjustment (2) Preparation:


1) Read the YAW sensor (SE8002 of JJ-004 board) sensitivity
Subject Pattern B
written on repair parts, and named this as S13.
(1.5 m from the front of lens)
Measurement Point Video terminal of A/V jack JJ-004 BOARD (SIDE A)
Measuring Instrument Oscilloscope (H period)
Adjustment Page 7F (Note 1)

2
Adjustment Address 13

SE8002

YY
4 3
Note 1: If reading/writing data on pages 7F, set data: 07 to page:
0, address: 10, and then select pages: F. By this data set- PP
ting, the pages 7F can be selected.

1
1 2
After the data reading/writing finished, return the data SE8001
on page: 0, address: 10 to “00”.
Note 2: The YAW sensor (SE8002 of JJ-004 board) sensitivity is
labeled only the repair parts. PITCH sensor
sensitivity t S12
Switch setting YAW sensor
1) POWER ......................................................... CAMERA mode sensitivity t S13
2) ND FILTER ...................................................................... OFF
3) ZOOM. .................................................................... TELE end
How to read the sensitivity data of angular velocity sen-
Preparation sor
1) Read the YAW sensor (SE8002 of JJ-004 board) sensitivity With the pins 1 and 2 of angular velocity sensor placed in the
written on repair parts, and named this as S13. lower position, read the data value.
Description example :
Pattern B For the sensor sensitivity value 60

4 3

6 0
White

White
Black

1 2

Hand Writing
A4 size (297 x 210 mm)

Fig. 6-1-20

HDR-FX7/FX7E_ADJ
6-60
Adjusting method:
H
Order Page Address Data Procedure
1 0 01 01
Set the zoom to TELE end,
2
and shoot the pattern B.
3 Adjust the focus.
4 0 10 07
D
5 (7D) 47 F0 Press PAUSE (Write) button.
D Press PAUSE (Write) button.
6 49 01
(7D) (Note 5)
Measure the falling edge of
7 waveform, SH1 (µsec). Falling edge of Falling edge of
(Fig. 6-1-21) waveform when waveform when
data is “10” data is “F0”
D
8 49 00 Press PAUSE (Write) button.
(7D)
D SH1–SH2
9 47 10 Press PAUSE (Write) button.
(7D)
D Press PAUSE (Write) button. SH1 (µsec)
10 49 01 SH2 (µsec)
(7D) (Note 5)
Measure the falling edge of
11 waveform, SH2 (µsec). Fig. 6-1-21
(Fig. 6-1-21)
D
12 49 00 Press PAUSE (Write) button.
(7D)
Calculate D13’ using
following equations.
(decimal calculation)
13 (Note 3)
D13’ = ((SH2 – SH1) ÷ 30) ×
S13 × 61
Convert D13’ to a hexadeci-
14 mal number, and obtain D13.
(Note 4)
F
15 13 D13 Press PAUSE (Write) button.
(7F)
16 0 10 00
Note 3: S13 is read in “Preparation”.
Note 4: Refer to table 6-4-1. “Hexadecimal-decimal conversion
table”.
Note 5: Finish this operation within 10 seconds. If it is likely to
take more than 10 seconds, set page: D (7D), address:
49, data: 00, and then retry.

Processing after Completing Adjustment:


Order Page Address Data Procedure
1 0 01 00
Check that the steady shot
2 function operates normally.

HDR-FX7/FX7E_ADJ
6-61
Ver. 1.1 2007.05

33. Auto White Balance Check (ND OFF) RadarW Checking method:
Subject Clear chart (Color reproduction Order Page Address Data Procedure
adjustment frame) 1 0 01 01
Filter ND filter 1.0, 0.4 and 0.1 2 6 CA 05
Measurement Point Adjusting remote commander 3 6 C9 10
Measuring Instrument 4 0 10 0A
Specified Value Data of page: 6, address: 0C is “00” E
5 8C 01 Press PAUSE (Write) button.
Note 1: Perform “Auto White Balance Adjustment” before this (AE)
adjustment. 6 0 10 00
Note 2: Check that the data of page: 6, address: 02 is “00”. OUTDOOR white balance check
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button. 7 6 01 4F Press PAUSE (Write) button.
Check the data changes to
8 6 02
Switch setting “01”.
1) POWER ......................................................... CAMERA mode 9 6 0C Check the data is “00”.
2) ND FILTER ...................................................................... OFF
3) D. EXTENDER (Menu setting) ...................................... OFF 10 6 01 00 Press PAUSE (Write) button.
4) STEADY SHOT (Menu setting) ..................................... OFF INDOOR white balance check
5) REC FORMAT (Menu setting) ............................. HDV1080i 11 6 01 0F Press PAUSE (Write) button.
Check the data changes to
12 6 02
“01”.
13 6 0C Check the data is “00”.
14 6 01 00 Press PAUSE (Write) button.
InOut check
15 0 10 0A
E
16 8C 00 Press PAUSE (Write) button.
(AE)
17 0 10 00
Place the ND filter 1.5 (1.0 +
18
0.4 + 0.1) on the lens.
19 6 C9 11
20 6 01 4B Press PAUSE (Write) button.
Check the data changes to
21 6 02 “01”.
22 6 0C Check the data is “00”.
23 6 01 00 Press PAUSE (Write) button.
Remove the ND filter 1.5
24
(1.0 + 0.4 + 0.1) on the lens.

Processing after Completing Adjustment:


Order Page Address Data Procedure
1 6 CA 00
2 6 C9 00
3 0 01 00

HDR-FX7/FX7E_ADJ
6-62
Ver. 1.1 2007.05

34. Auto White Balance Check (ND 1) RadarW Checking method:


Subject Clear chart (Color reproduction Order Page Address Data Procedure
adjustment frame) 1 0 01 01
Filter ND filter 1.0, 0.4 and 0.1 2 6 CA 05
Measurement Point Adjusting remote commander 3 6 C9 10
Measuring Instrument 4 0 10 0A
Specified Value Data of page: 6, address: 0C is “00” E
5 8C 01 Press PAUSE (Write) button.
Note 1: Perform “Auto White Balance Adjustment” before this (AE)
adjustment. 6 0 10 00
Note 2: Check that the data of page: 6, address: 02 is “00”. OUTDOOR white balance check
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button. 7 6 01 4F Press PAUSE (Write) button.
Check the data changes to
8 6 02
Switch setting “01”.
1) POWER ......................................................... CAMERA mode 9 6 0C Check the data is “00”.
2) ND FILTER ............................................................................ 1
3) D. EXTENDER (Menu setting) ...................................... OFF 10 6 01 00 Press PAUSE (Write) button.
4) STEADY SHOT (Menu setting) ..................................... OFF INDOOR white balance check
5) REC FORMAT (Menu setting) ............................. HDV1080i 11 6 01 0F Press PAUSE (Write) button.
Check the data changes to
12 6 02
“01”.
13 6 0C Check the data is “00”.
14 6 01 00 Press PAUSE (Write) button.
InOut check
15 0 10 0A
E
16 8C 00 Press PAUSE (Write) button.
(AE)
17 0 10 00
Place the ND filter 1.5 (1.0 +
18
0.4 + 0.1) on the lens.
19 6 C9 11
20 6 01 4B Press PAUSE (Write) button.
Check the data changes to
21 6 02
“01”.
22 6 0C Check the data is “00”.
23 6 01 00 Press PAUSE (Write) button.
Remove the ND filter 1.5
24
(1.0 + 0.4 + 0.1) on the lens.

Processing after Completing Adjustment:


Order Page Address Data Procedure
1 6 CA 00
2 6 C9 00
3 0 01 00

HDR-FX7/FX7E_ADJ
6-63
Ver. 1.1 2007.05

35. Auto White Balance Check (ND 2) RadarW Checking method:


Subject Clear chart (Color reproduction Order Page Address Data Procedure
adjustment frame) 1 0 01 01
Filter ND filter 1.0, 0.4 and 0.1 2 6 CA 05
Measurement Point Adjusting remote commander 3 6 C9 10
Measuring Instrument 4 0 10 0A
Specified Value Data of page: 6, address: 0C is “00” E
5 8C 01 Press PAUSE (Write) button.
Note 1: Perform “Auto White Balance Adjustment” before this (AE)
adjustment. 6 0 10 00
Note 2: Check that the data of page: 6, address: 02 is “00”. OUTDOOR white balance check
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button. 7 6 01 4F Press PAUSE (Write) button.
Check the data changes to
8 6 02
Switch setting “01”.
1) POWER ......................................................... CAMERA mode 9 6 0C Check the data is “00”.
2) ND FILTER ............................................................................ 2
3) D. EXTENDER (Menu setting) ...................................... OFF 10 6 01 00 Press PAUSE (Write) button.
4) STEADY SHOT (Menu setting) ..................................... OFF INDOOR white balance check
5) REC FORMAT (Menu setting) ............................. HDV1080i 11 6 01 0F Press PAUSE (Write) button.
Check the data changes to
12 6 02
“01”.
13 6 0C Check the data is “00”.
14 6 01 00 Press PAUSE (Write) button.
InOut check
15 0 10 0A
E
16 8C 00 Press PAUSE (Write) button.
(AE)
17 0 10 00
Place the ND filter 1.5 (1.0 +
18
0.4 + 0.1) on the lens.
*19 6 13 BF (* PAL model only)
20 6 C9 11
21 6 01 4B Press PAUSE (Write) button.
Check the data changes to
22 6 02
“01”.
23 6 0C Check the data is “00”.
24 6 01 00 Press PAUSE (Write) button.
Remove the ND filter 1.5
25
(1.0 + 0.4 + 0.1) on the lens.

Processing after Completing Adjustment:


Order Page Address Data Procedure
1 6 CA 00
2 6 C9 00
*3 6 13 00 (* PAL model only)
4 0 01 00

HDR-FX7/FX7E_ADJ
6-64
36. Color Reproduction Check (Indoor HD: ND OFF) Checking method:
RadarW Order Page Address Data Procedure
Subject Color bar chart (Color reproduction 1 0 01 01
adjustment frame) 2 0 10 0A
Measurement Point Video terminal of Adjusting remote E
A/V jack commander 3 8C 01 Press PAUSE (Write) button.
(AE)
(75 Ω terminated)
4 0 10 00
Measuring Instrument Vectorscope
5 6 C9 10
Specified Value All color Data of page: 6
luminance address: 0C is 6 6 CA 04
points should “00” 7 6 D0 49
settle within each 8 6 01 4D Press PAUSE (Write) button.
color
reproduction Check the data changes to
9 6 02
frame. “01”.
10 6 0C Check the data is “00”.
Note 1: Perform “Color Reproduction Adjustment” before this
adjustment. Adjust the GAIN and
Note 2: Check that the data of page: 6, address: 02 is “00”. PHASE of the vectorscope,
If not, select page: 6, address: 01, set data: 00, and press 11 and set to the burst lumi-
PAUSE (Write) button. nance point to the burst
position of color reproduc-
Switch setting tion frame.
1) POWER ......................................................... CAMERA mode Check that the each color
2) ND FILTER ...................................................................... OFF 12 luminance point is in each
3) D. EXTENDER (Menu setting) ...................................... OFF color reproduction frame.
4) STEADY SHOT (Menu setting) ..................................... OFF
5) REC FORMAT (Menu setting) ............................. HDV1080i
Processing after Completing Adjustment:
NTSC model (Indoor HD) Order Page Address Data Procedure
R-Y
1 6 01 00 Press PAUSE (Write) button.
2 6 CA 00
R MG
3 6 C9 00
4 0 10 0A
YE E
5 8C 00 Press PAUSE (Write) button.
B-Y (AE)
B 6 0 10 00
7 0 01 00
G
CY

Burst position

PAL model (Indoor HD)

R-Y
Burst position

R MG

YE
B-Y
B

G
CY

Fig. 6-1-22

HDR-FX7/FX7E_ADJ
6-65
37. Color Reproduction Check (Indoor HD: ND 1) Checking method:
RadarW Order Page Address Data Procedure
Subject Color bar chart (Color reproduction 1 0 01 01
adjustment frame) 2 0 10 0A
Measurement Point Video terminal of Adjusting remote E
A/V jack commander 3 8C 01 Press PAUSE (Write) button.
(AE)
(75 Ω terminated)
4 0 10 00
Measuring Instrument Vectorscope
5 6 C9 10
Specified Value All color Data of page: 6
luminance address: 0C is 6 6 CA 04
points should “00” 7 6 D0 48
settle within each 8 6 01 4D Press PAUSE (Write) button.
color
reproduction Check the data changes to
9 6 02
frame. “01”.
10 6 0C Check the data is “00”.
Note 1: Perform “Color Reproduction Adjustment” before this
adjustment. Adjust the GAIN and
Note 2: Check that the data of page: 6, address: 02 is “00”. PHASE of the vectorscope,
If not, select page: 6, address: 01, set data: 00, and press 11 and set to the burst lumi-
PAUSE (Write) button. nance point to the burst
position of color reproduc-
Switch setting tion frame.
1) POWER ......................................................... CAMERA mode Check that the each color
2) ND FILTER ............................................................................ 1 12 luminance point is in each
3) D. EXTENDER (Menu setting) ...................................... OFF color reproduction frame.
4) STEADY SHOT (Menu setting) ..................................... OFF
5) REC FORMAT (Menu setting) ............................. HDV1080i
Processing after Completing Adjustment:
Order Page Address Data Procedure
1 6 01 00 Press PAUSE (Write) button.
2 6 CA 00
3 6 C9 00
4 0 10 0A
E
5 8C 00 Press PAUSE (Write) button.
(AE)
6 0 10 00
7 0 01 00

HDR-FX7/FX7E_ADJ
6-66
Ver. 1.1 2007.05

38. Color Reproduction Check (Indoor HD: ND 2) Checking method:


RadarW Order Page Address Data Procedure
Subject Color bar chart (Color reproduction 1 0 01 01
adjustment frame) 2 0 10 0A
Measurement Point Video terminal of Adjusting remote E
A/V jack commander 3 8C 01 Press PAUSE (Write) button.
(AE)
(75 Ω terminated)
4 0 10 00
Measuring Instrument Vectorscope
5 6 15 86
Specified Value All color Data of page: 6
luminance address: 0C is 6 6 C9 10
points should “00” 7 6 CA 04
settle within each 8 6 D0 47
color
reproduction 9 6 01 4D Press PAUSE (Write) button.
frame. Check the data changes to
10 6 02
“01”.
Note 1: Perform “Color Reproduction Adjustment” before this
adjustment. 11 6 0C Check the data is “00”.
Note 2: Check that the data of page: 6, address: 02 is “00”. Adjust the GAIN and
If not, select page: 6, address: 01, set data: 00, and press PHASE of the vectorscope,
PAUSE (Write) button. 12 and set to the burst lumi-
nance point to the burst
Switch setting position of color reproduc-
1) POWER ......................................................... CAMERA mode tion frame.
2) ND FILTER ............................................................................ 2 Check that the each color
3) D. EXTENDER (Menu setting) ...................................... OFF 13 luminance point is in each
4) STEADY SHOT (Menu setting) ..................................... OFF color reproduction frame.
5) REC FORMAT (Menu setting) ............................. HDV1080i

Processing after Completing Adjustment:


Order Page Address Data Procedure
1 6 01 00 Press PAUSE (Write) button.
2 6 CA 00
3 6 C9 00
4 6 15 00
5 0 10 0A
E
6 8C 00 Press PAUSE (Write) button.
(AE)
7 0 10 00
8 0 01 00

HDR-FX7/FX7E_ADJ
6-67
39. Color Reproduction Check (Indoor SD: ND OFF) Checking method:
RadarW Order Page Address Data Procedure
Subject Color bar chart (Color reproduction 1 0 01 01
adjustment frame) 2 0 10 0A
Measurement Point Video terminal of Adjusting remote E
A/V jack commander 3 8C 01 Press PAUSE (Write) button.
(AE)
(75 Ω terminated)
4 0 10 00
Measuring Instrument Vectorscope
5 6 C9 10
Specified Value All color Data of page: 6
luminance address: 0C is 6 6 CA 04
points should “00” 7 6 D0 49
settle within each 8 6 01 4D Press PAUSE (Write) button.
color
reproduction Check the data changes to
9 6 02
frame. “01”.
10 6 0C Check the data is “00”.
Note 1: Perform “Color Reproduction Adjustment” before this
adjustment. Adjust the GAIN and
Note 2: Check that the data of page: 6, address: 02 is “00”. PHASE of the vectorscope,
If not, select page: 6, address: 01, set data: 00, and press 11 and set to the burst lumi-
PAUSE (Write) button. nance point to the burst
position of color reproduc-
Switch setting tion frame.
1) POWER ......................................................... CAMERA mode Check that the each color
2) ND FILTER ...................................................................... OFF 12 luminance point is in each
3) D. EXTENDER (Menu setting) ...................................... OFF color reproduction frame.
4) STEADY SHOT (Menu setting) ..................................... OFF
5) REC FORMAT (Menu setting) ......................................... DV
Processing after Completing Adjustment:
NTSC model (Indoor SD) Order Page Address Data Procedure
R-Y 1 6 01 00 Press PAUSE (Write) button.
2 6 CA 00
R MG
3 6 C9 00
4 0 10 0A
E
YE 5 8C 00 Press PAUSE (Write) button.
(AE)
B-Y
6 0 10 00
B
7 0 01 00

G
CY
Burst position

PAL model (Indoor SD)


R-Y
Burst position
R MG

YE
B-Y

G
CY

Fig. 6-1-23

HDR-FX7/FX7E_ADJ
6-68
40. Color Reproduction Check (Indoor SD: ND 1) Checking method:
RadarW Order Page Address Data Procedure
Subject Color bar chart (Color reproduction 1 0 01 01
adjustment frame) 2 0 10 0A
Measurement Point Video terminal of Adjusting remote E
A/V jack commander 3 8C 01 Press PAUSE (Write) button.
(AE)
(75 Ω terminated)
4 0 10 00
Measuring Instrument Vectorscope
5 6 C9 10
Specified Value All color Data of page: 6
luminance address: 0C is 6 6 CA 04
points should “00” 7 6 D0 48
settle within each 8 6 01 4D Press PAUSE (Write) button.
color
reproduction Check the data changes to
9 6 02
frame. “01”.
10 6 0C Check the data is “00”.
Note 1: Perform “Color Reproduction Adjustment” before this
adjustment. Adjust the GAIN and
Note 2: Check that the data of page: 6, address: 02 is “00”. PHASE of the vectorscope,
If not, select page: 6, address: 01, set data: 00, and press 11 and set to the burst lumi-
PAUSE (Write) button. nance point to the burst
position of color reproduc-
Switch setting tion frame.
1) POWER ......................................................... CAMERA mode Check that the each color
2) ND FILTER ............................................................................ 1 12 luminance point is in each
3) D. EXTENDER (Menu setting) ...................................... OFF color reproduction frame.
4) STEADY SHOT (Menu setting) ..................................... OFF
5) REC FORMAT (Menu setting) ......................................... DV
Processing after Completing Adjustment:
Order Page Address Data Procedure
1 6 01 00 Press PAUSE (Write) button.
2 6 CA 00
3 6 C9 00
4 0 10 0A
E
5 8C 00 Press PAUSE (Write) button.
(AE)
6 0 10 00
7 0 01 00

HDR-FX7/FX7E_ADJ
6-69
Ver. 1.1 2007.05

41. Color Reproduction Check (Indoor SD: ND 2) Checking method:


RadarW Order Page Address Data Procedure
Subject Color bar chart (Color reproduction 1 0 01 01
adjustment frame) 2 0 10 0A
Measurement Point Video terminal of Adjusting remote E
A/V jack commander 3 8C 01 Press PAUSE (Write) button.
(AE)
(75 Ω terminated)
4 0 10 00
Measuring Instrument Vectorscope
5 6 15 86
Specified Value All color Data of page: 6
luminance address: 0C is 6 6 C9 10
points should “00” 7 6 CA 04
settle within each 8 6 D0 47
color
reproduction 9 6 01 4D Press PAUSE (Write) button.
frame. Check the data changes to
10 6 02
“01”.
Note 1: Perform “Color Reproduction Adjustment” before this
adjustment. 11 6 0C Check the data is “00”.
Note 2: Check that the data of page: 6, address: 02 is “00”. Adjust the GAIN and
If not, select page: 6, address: 01, set data: 00, and press PHASE of the vectorscope,
PAUSE (Write) button. 12 and set to the burst lumi-
nance point to the burst
Switch setting position of color reproduc-
1) POWER ......................................................... CAMERA mode tion frame.
2) ND FILTER ............................................................................ 2 Check that the each color
3) D. EXTENDER (Menu setting) ...................................... OFF 13 luminance point is in each
4) STEADY SHOT (Menu setting) ..................................... OFF color reproduction frame.
5) REC FORMAT (Menu setting) ......................................... DV

Processing after Completing Adjustment:


Order Page Address Data Procedure
1 6 01 00 Press PAUSE (Write) button.
2 6 CA 00
3 6 C9 00
4 6 15 00
5 0 10 0A
E
6 8C 00 Press PAUSE (Write) button.
(AE)
7 0 10 00
8 0 01 00

HDR-FX7/FX7E_ADJ
6-70
42. Color Reproduction Check (Outdoor HD: ND OFF) Checking method:
RadarW Order Page Address Data Procedure
Subject Color bar chart (Color reproduction Place the C14 filter on the
1
adjustment frame) lens.
Filter ND filter 1.0, 0.4 and 0.1 2 0 01 01
Measurement Point Video terminal of Adjusting remote 3 0 10 0A
A/V jack commander E
(75 Ω terminated) 4
(AE)
8C 01 Press PAUSE (Write) button.
Measuring Instrument Vectorscope 5 0 10 00
Specified Value All color Data of page: 6, 6 6 C9 10
luminance address: 0C is
points should “00” 7 6 CA 04
settle within each 8 6 D0 49
color 9 6 01 3D Press PAUSE (Write) button.
reproduction
frame. Check the data changes to
10 6 02
“01”.
Note 1: Perform “Color Reproduction Adjustment” before this 11 6 0C Check the data is “00”.
adjustment.
Note 2: Check that the data of page: 6, address: 02 is “00”. If Adjust the GAIN and
not, select page: 6, address: 01, set data: 00, and press PHASE of the vectorscope,
PAUSE (Write) button. and set to the burst lumi-
12 nance point to the burst
Switch setting position of color reproduc-
1) POWER ......................................................... CAMERA mode tion frame.
2) ND FILTER ...................................................................... OFF Check that the each color
3) D. EXTENDER (Menu setting) ...................................... OFF 13 luminance point is in each
4) STEADY SHOT (Menu setting) ..................................... OFF color reproduction frame.
5) REC FORMAT (Menu setting) ............................. HDV1080i
Processing after Completing Adjustment:
NTSC model (Outdoor HD)
R-Y Order Page Address Data Procedure
1 6 01 00 Press PAUSE (Write) button.
R MG 2 6 CA 00
3 6 C9 00
4 0 10 0A
YE

B-Y
E
5 8C 00 Press PAUSE (Write) button.
B
(AE)
6 0 10 00
7 0 01 00
G
CY Remove the C14 filter on the
8
Burst position lens.

PAL model (Outdoor HD)


R-Y
Burst position

R MG

YE

B-Y
B

G
CY

Fig. 6-1-24

HDR-FX7/FX7E_ADJ
6-71
43. Color Reproduction Check (Outdoor HD: ND 1) Checking method:
RadarW Order Page Address Data Procedure
Subject Color bar chart (Color reproduction Place the C14 filter on the
1
adjustment frame) lens.
Filter ND filter 1.0, 0.4 and 0.1 2 0 01 01
Measurement Point Video terminal of Adjusting remote 3 0 10 0A
A/V jack commander E
(75 Ω terminated) 4
(AE)
8C 01 Press PAUSE (Write) button.
Measuring Instrument Vectorscope 5 0 10 00
Specified Value All color Data of page: 6, 6 6 C9 10
luminance address: 0C is
points should “00” 7 6 CA 04
settle within each 8 6 D0 48
color 9 6 01 3D Press PAUSE (Write) button.
reproduction
frame. Check the data changes to
10 6 02
“01”.
Note 1: Perform “Color Reproduction Adjustment” before this 11 6 0C Check the data is “00”.
adjustment.
Note 2: Check that the data of page: 6, address: 02 is “00”. If Adjust the GAIN and
not, select page: 6, address: 01, set data: 00, and press PHASE of the vectorscope,
PAUSE (Write) button. and set to the burst lumi-
12 nance point to the burst
Switch setting position of color reproduc-
1) POWER ......................................................... CAMERA mode tion frame.
2) ND FILTER ............................................................................ 1 Check that the each color
3) D. EXTENDER (Menu setting) ...................................... OFF 13 luminance point is in each
4) STEADY SHOT (Menu setting) ..................................... OFF color reproduction frame.
5) REC FORMAT (Menu setting) ............................. HDV1080i
Processing after Completing Adjustment:
Order Page Address Data Procedure
1 6 01 00 Press PAUSE (Write) button.
2 6 CA 00
3 6 C9 00
4 0 10 0A
E
5 8C 00 Press PAUSE (Write) button.
(AE)
6 0 10 00
7 0 01 00
Remove the C14 filter on the
8
lens.

HDR-FX7/FX7E_ADJ
6-72
44. Color Reproduction Check (Outdoor HD: ND 2) Checking method:
RadarW Order Page Address Data Procedure
Subject Color bar chart (Color reproduction Place the C14 filter on the
1
adjustment frame) lens.
Filter ND filter 1.0, 0.4 and 0.1 2 0 01 01
Measurement Point Video terminal of Adjusting remote 3 0 10 0A
A/V jack commander E
(75 Ω terminated) 4
(AE)
8C 01 Press PAUSE (Write) button.
Measuring Instrument Vectorscope 5 0 10 00
Specified Value All color Data of page: 6, 6 6 C9 10
luminance address: 0C is
points should “00” 7 6 CA 04
settle within each 8 6 D0 47
color *9 0 10 06 (*PAL model only)
reproduction
frame. D (*PAL model only)
*10 5E
(6D) Note down the data.
Note 1: Perform “Color Reproduction Adjustment” before this D (*PAL model only)
adjustment. *11 5E 5C
(6D) Press PAUSE (Write) button.
Note 2: Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press *12 0 10 00 (*PAL model only)
PAUSE (Write) button. 13 6 01 3D Press PAUSE (Write) button.
Check the data changes to
Switch setting 14 6 02
“01”.
1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 2 15 6 0C Check the data is “00”.
3) D. EXTENDER (Menu setting) ...................................... OFF Adjust the GAIN and
4) STEADY SHOT (Menu setting) ..................................... OFF PHASE of the vectorscope,
5) REC FORMAT (Menu setting) ............................. HDV1080i and set to the burst lumi-
16 nance point to the burst
position of color reproduc-
tion frame.
Check that the each color
17 luminance point is in each
color reproduction frame.

Processing after Completing Adjustment:


Order Page Address Data Procedure
1 6 01 00 Press PAUSE (Write) button.
2 6 CA 00
3 6 C9 00
4 0 10 0A
E
5 8C 00 Press PAUSE (Write) button.
(AE)
*6 0 10 06 (*PAL model only)
(*PAL model only)
D Set data noted down at step
*7 5E
(6D) 10, and press PAUSE (Write)
button.
8 0 10 00
9 0 01 00
Remove the C14 filter on the
10
lens.

HDR-FX7/FX7E_ADJ
6-73
45. Color Reproduction Check (Outdoor SD: ND OFF) Checking method:
RadarW Order Page Address Data Procedure
Subject Color bar chart (Color reproduction Place the C14 filter on the
1
adjustment frame) lens.
Filter ND filter 1.0, 0.4 and 0.1 2 0 01 01
Measurement Point Video terminal of Adjusting remote 3 0 10 0A
A/V jack commander E
(75 Ω terminated) 4
(AE)
8C 01 Press PAUSE (Write) button.
Measuring Instrument Vectorscope 5 0 10 00
Specified Value All color Data of page: 6, 6 6 C9 10
luminance address: 0C is
points should “00” 7 6 CA 04
settle within each 8 6 D0 49
color 9 6 01 3D Press PAUSE (Write) button.
reproduction
frame. Check the data changes to
10 6 02
“01”.
Note 1: Perform “Color Reproduction Adjustment” before this 11 6 0C Check the data is “00”.
adjustment.
Note 2: Check that the data of page: 6, address: 02 is “00”. If Adjust the GAIN and
not, select page: 6, address: 01, set data: 00, and press PHASE of the vectorscope,
PAUSE (Write) button. and set to the burst lumi-
12 nance point to the burst
Switch setting position of color reproduc-
1) POWER ......................................................... CAMERA mode tion frame.
2) ND FILTER ...................................................................... OFF Check that the each color
3) D. EXTENDER (Menu setting) ...................................... OFF 13 luminance point is in each
4) STEADY SHOT (Menu setting) ..................................... OFF color reproduction frame.
5) REC FORMAT (Menu setting) ......................................... DV
Processing after Completing Adjustment:
NTSC model (Outdoor SD)
R-Y
Order Page Address Data Procedure
1 6 01 00 Press PAUSE (Write) button.
R MG 2 6 CA 00
3 6 C9 00
4 0 10 0A
YE
E
B-Y 5 8C 00 Press PAUSE (Write) button.
(AE)
B
6 0 10 00
7 0 01 00
G CY
Remove the C14 filter on the
8
Burst position lens.

PAL model (Outdoor SD)


R-Y
Burst position
R MG

YE

B-Y

G CY

Fig. 6-1-25

HDR-FX7/FX7E_ADJ
6-74
Ver. 1.1 2007.05

46. Color Reproduction Check (Outdoor SD: ND 1) Checking method:


RadarW Order Page Address Data Procedure
Subject Color bar chart (Color reproduction Place the C14 filter on the
1
adjustment frame) lens.
Filter ND filter 1.0, 0.4 and 0.1 2 0 01 01
Measurement Point Video terminal of Adjusting remote 3 0 10 0A
A/V jack commander E
(75 Ω terminated) 4
(AE)
8C 01 Press PAUSE (Write) button.
Measuring Instrument Vectorscope 5 0 10 00
Specified Value All color Data of page: 6, 6 6 C9 10
luminance address: 0C is
points should “00” 7 6 CA 04
settle within each 8 6 D0 48
color 9 6 01 3D Press PAUSE (Write) button.
reproduction
frame. Check the data changes to
10 6 02
“01”.
Note 1: Perform “Color Reproduction Adjustment” before this 11 6 0C Check the data is “00”.
adjustment.
Note 2: Check that the data of page: 6, address: 02 is “00”. If Adjust the GAIN and
not, select page: 6, address: 01, set data: 00, and press PHASE of the vectorscope,
PAUSE (Write) button. and set to the burst lumi-
12 nance point to the burst
Switch setting position of color reproduc-
1) POWER ......................................................... CAMERA mode tion frame.
2) ND FILTER ............................................................................ 1 Check that the each color
3) D. EXTENDER (Menu setting) ...................................... OFF 13 luminance point is in each
4) STEADY SHOT (Menu setting) ..................................... OFF color reproduction frame.
5) REC FORMAT (Menu setting) ......................................... DV
Processing after Completing Adjustment:
Order Page Address Data Procedure
1 6 01 00 Press PAUSE (Write) button.
2 6 CA 00
3 6 C9 00
4 0 10 0A
E
5 8C 00 Press PAUSE (Write) button.
(AE)
6 0 10 00
7 0 01 00
Remove the C14 filter on the
8
lens.

HDR-FX7/FX7E_ADJ
6-75
47. Color Reproduction Check (Outdoor SD: ND 2) Checking method:
RadarW Order Page Address Data Procedure
Subject Color bar chart (Color reproduction Place the C14 filter on the
1
adjustment frame) lens.
Filter ND filter 1.0, 0.4 and 0.1 2 0 01 01
Measurement Point Video terminal of Adjusting remote 3 0 10 0A
A/V jack commander E
(75 Ω terminated) 4
(AE)
8C 01 Press PAUSE (Write) button.
Measuring Instrument Vectorscope 5 0 10 00
Specified Value All color Data of page: 6, 6 6 C9 10
luminance address: 0C is
points should “00” 7 6 CA 04
settle within each 8 6 D0 47
color *9 0 10 06 (*PAL model only)
reproduction
frame. D (*PAL model only)
*10 5E
(6D) Note down the data.
Note 1: Perform “Color Reproduction Adjustment” before this D (*PAL model only)
adjustment. *11 5E 5C
(6D) Press PAUSE (Write) button.
Note 2: Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press *12 0 10 00 (*PAL model only)
PAUSE (Write) button. 13 6 01 3D Press PAUSE (Write) button.
Check the data changes to
Switch setting 14 6 02
“01”.
1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 2 15 6 0C Check the data is “00”.
3) D. EXTENDER (Menu setting) ...................................... OFF Adjust the GAIN and
4) STEADY SHOT (Menu setting) ..................................... OFF PHASE of the vectorscope,
5) REC FORMAT (Menu setting) ......................................... DV and set to the burst lumi-
16 nance point to the burst
position of color reproduc-
tion frame.
Check that the each color
17 luminance point is in each
color reproduction frame.

Processing after Completing Adjustment:


Order Page Address Data Procedure
1 6 01 00 Press PAUSE (Write) button.
2 6 CA 00
3 6 C9 00
4 0 10 0A
E
5 8C 00 Press PAUSE (Write) button.
(AE)
*6 0 10 06 (*PAL model only)
(*PAL model only)
D Set data noted down at step
*7 5E
(6D) 10, and press PAUSE (Write)
button.
8 0 10 00
9 0 01 00
Remove the C14 filter on the
10
lens.

HDR-FX7/FX7E_ADJ
6-76
1-4. ELECTRONIC VIEWFINDER SYSTEM
ADJUSTMENTS
Before perform the viewfinder system adjustments, check the data
of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”.

Note 1: Taken an extreme care not to destroy the liquid crystal


display module by static electricity when replacing it.
Note 2: Perform the following data setting before the viewfinder
system adjustments.
1) Select page: 3, address: C4, and set data: 67.
2) Select page: 3, address: C5, and set data: 01.
Reset the data after completing adjustment.
1) Select page: 3, address: C4, and set data: 00.
2) Select page: 3, address: C5, and set data: 00.

Switch setting
1) REC FORMAT (Menu setting) ............................ HDV 1080i

[Adjusting connector]
Most of the measuring points for adjusting the viewfinder system
are concentrated in CN1014 of the TT-003 board.
Connect the Measuring Instruments via the CPC-7 jig (J-6082-
382-A).
The following table shown the Pin No. and signal name of CN1014.
Pin No. Signal Name Pin No. Signal Name
1 EVF_COM_DC 9 RF_MON
2 REG_GND 10 REG_GND
3 EXT_DA 11 SWP
4 EVF_VCO 12 FRRV
5 EVF_VG 13 REC_CRRT1_S
6 PSIG 14 REC_CRRT0_S
7 REG_GND 15 REC_CRRT1_C
8 REG_GND 16 REC_CRRT0_C

Adjustment remote
commander
TT-003 board
(NEW LANC JIG)

16

CN1014 1
(RM-95)

LANC jack

16
CPC-7 jig
(J-6082-382-A) 1

DC IN jack
AC IN
AC adaptor

Fig. 6-1-26

HDR-FX7/FX7E_ADJ
6-77
1. VCO Adjustment (OO-003 board)
Set the VCO free-run frequency. If deviated, the EVF screen will
be blurred.
Mode CAMERA
Subject Not required
Measurement Point Pin 4 of CN1014 (EVF_VCO) on
TT-003 board
Measuring Instrument Frequency counter
Adjustment Page C
Adjustment Address 34, 35
Specified Value f = 15734 ± 30 Hz (NTSC)
f = 15625 ± 30 Hz (PAL)
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Refer to Table 6-4-1. “Hexadecimal-decimal conversion
table”
Note 3: If D35’ > 255, then D35 = FF (NTSC model)
If D34’ < 0, then D34 = 00 (PAL model)

Adjusting method for NTSC model: Adjusting method for PAL model:
Order Page Address Data Procedure Order Page Address Data Procedure
1 0 01 01 1 0 01 01
2 3 71 01 Press PAUSE (Write) button. 2 3 71 01 Press PAUSE (Write) button.
Change the data and set the Change the data and set the
3 C 34 frequency (f) to the specified 3 C 35 frequency (f) to the specified
value. value.
4 C 34 Press PAUSE (Write) button. 4 C 35 Press PAUSE (Write) button.
Read the data and this data is Read the data and this data is
5 C 34 5 C 35
named D34. named D35.
Convert D34 to decimal Convert D35 to decimal
6 notation, and obtain D34’. 6 notation, and obtain D35’.
(Note 2) (Note 2)
Calculate D35’ using Calculate D34’ using
7 following equations. following equations.
(decimal calculation) 7 (decimal calculation)
D35’ = D34’ + 21 D34’ = D35’ – 21
Convert D35’ to a hexadeci- Convert D34’ to a hexadeci-
8 mal number, and obtain D35. 8 mal number, and obtain D34.
(Note 2, 3) (Note 2, 3)
9 C 35 D35 Press PAUSE (Write) button. 9 C 34 D34 Press PAUSE (Write) button.
10 3 70 10 Press PAUSE (Write) button. 10 3 70 10 Press PAUSE (Write) button.

11 3 70 Check the data changes to Check the data changes to


11 3 70
“11”. “11”.
12 0 01 00 12 0 01 00

HDR-FX7/FX7E_ADJ
6-78
2. Back Light Adjustment (OO-003 board) 3. PSIG Level Adjustment (OO-003 board)
Set the back light luminance. Set the uniformity improvement signal level to an appropriate level.
If deviated, the image may become dark or bright.
Mode CAMERA
Mode CAMERA Subject Not required
Subject Not required Measurement Point Pin 6 of CN1014 (PSIG) on TT-
Measurement Point Pin 3 of CN1014 (EXT_DA) on 003 board
TT-003 board Measuring Instrument Oscilloscope
Measuring Instrument Digital voltmeter Adjustment Page C
Adjustment Page C Adjustment Address 39
Adjustment Address 32, 33 Specified Value A = 6.00 ± 0.05 Vp-p
Specified Value NORMAL mode:
Note: Check that the data of page: 0, address: 10 is “00”.
A = 0.94 ± 0.05 Vdc
BRIGHT mode:
Adjusting method:
B = 1.73 ± 0.05 Vdc
Order Page Address Data Procedure
Note: Check that the data of page: 0, address: 10 is “00”.
1 0 01 01
Adjusting method: 2 3 71 01 Press PAUSE (Write) button.
Order Page Address Data Procedure Change the data and set the
1 0 01 01 PSIG signal level (A) to the
3 C 39 specified value.
2 3 71 01 Press PAUSE (Write) button. (The data should be “00” to
Change the data and set the “7F”.)
DC voltage (A) to the 4 C 39 Press PAUSE (Write) button.
3 C 32
specified value of NORMAL
mode. 5 3 70 10 Press PAUSE (Write) button.

4 C 32 Press PAUSE (Write) button. 6 3 70 Check the data changes to


“11”.
Change the data and set the
DC voltage (B) to the 7 0 01 00
5 C 33
specified value of BRIGHT
mode.
6 C 33 Press PAUSE (Write) button.
7 3 70 10 Press PAUSE (Write) button.

8 3 70 Check the data changes to A


“11”.
9 0 01 00

2H

Fig. 6-1-27

HDR-FX7/FX7E_ADJ
6-79
4. V-COM Level Adjustment (OO-003 board) 5. RGB AMP Adjustment (OO-003 board)
Set the opposed voltage to drive LCD panel to an appropriate level. Set the D Range of the RGB decoder for driving the LCD to the
specified value.
Mode CAMERA
If deviated, the EVF screen image will be blackish or saturated
Subject Not required (whitish).
Measurement Point Pin 1 of CN1014 (EVF_COM_DC) Mode CAMERA
on TT-003 board
Subject Not required
Measuring Instrument Digital voltmeter
Measurement Point Pin 5 of CN1014 (EVF_VG) on
Adjustment Page C TT-003 board
Adjustment Address 36 Measuring Instrument Oscilloscope
Specified Value A = 6.65 ± 0.05 Vdc Adjustment Page C
Note: Check that the data of page: 0, address: 10 is “00”. Adjustment Address 37
Specified Value A = 7.00 ± 0.10 Vp-p
Adjusting method:
Note: Check that the data of page: 0, address: 10 is “00”.
Order Page Address Data Procedure
1 0 01 01 Adjusting method:
2 3 71 01 Press PAUSE (Write) button. Order Page Address Data Procedure
Change the data and set the 1 0 01 01
DC voltage (A) to the
3 C 36 2 3 71 01 Press PAUSE (Write) button.
specified value. (The data
should be “00” to “3F”.) Change the data and set the
4 C 36 Press PAUSE (Write) button. 3 C 37 voltage (A) to the specified
value.
5 3 70 10 Press PAUSE (Write) button.
4 C 37 Press PAUSE (Write) button.
6 3 70 Check the data changes to
“11”. 5 3 70 10 Press PAUSE (Write) button.
7 0 01 00 6 3 70 Check the data changes to
“11”.
7 0 01 00

Pedestal

2H
Pedestal

A: Between the reversed waveform pedestal


and non-reversed waveform pedestal

Fig. 6-1-28

HDR-FX7/FX7E_ADJ
6-80
6. Contrast Adjustment (OO-003 board) 7. White Balance Adjustment (OO-003 board)
Set the video signal level for driving the LCD to the specified Correct the white balance.
value. If deviated, the EVF screen color cannot be reproduced.
If deviated, the EVF screen image will be blackish or saturated
Mode CAMERA
(whitish).
Subject Not required
Mode CAMERA
Measurement Point Check on EVF screen
Subject Not required
Measuring Instrument
Measurement Point Pin 5 of CN1014 (EVF_VG) on
TT-003 board Adjustment Page C

Measuring Instrument Oscilloscope Adjustment Address 3A, 3B

Adjustment Page C Specified Value EVF screen must not be colored

Adjustment Address 3C, 77 Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Check the white balance only when replacing the fol-
Specified Value A = 2.30 ± 0.05 Vp-p
lowing parts. If necessary, adjust them.
Note: Check that the data of page: 0, address: 10 is “00”. 1. LCD panel
2. Light induction plate
Adjusting method: 3. IC6601
Order Page Address Data Procedure
Adjusting method:
1 0 01 01
Order Page Address Data Procedure
2 3 71 01 Press PAUSE (Write) button.
1 0 01 01
Change the data and set the
voltage (A) to the specified 2 3 71 01 Press PAUSE (Write) button.
3 C 77
value. (The data should be 3 C 3A 80 Press PAUSE (Write) button.
“00” to “7F”.) 4 C 3B 80 Press PAUSE (Write) button.
4 C 77 Press PAUSE (Write) button. Check that the EVF screen is
Read the data and this data is 5 not colored. If not colored,
5 C 77
named D77. proceed to step 6.
6 C 3C D77 Press PAUSE (Write) button. 3A Change the data so that the
7 3 70 10 Press PAUSE (Write) button. 6 C EVF screen is not colored.
3B
(Note 3)
8 3 70 Check the data changes to
“11”. 7 3 70 10 Press PAUSE (Write) button.
9 0 01 00 8 3 70 Check the data changes to
“11”.
9 0 01 00
Note 3: To write in the non-volatile memory (EEPROM), press
the PAUSE (Write) button each time to set the data.
The data of page: C, address: 3A should be “66” to “B2”.
The data of page: C, address: 3B should be “60” to “A6”.

3 steps peak

2H
Pedestal

A: Between the pedestal and 3 steps peak

Fig. 6-1-29

HDR-FX7/FX7E_ADJ
6-81
1-5. LCD SYSTEM ADJUSTMENTS Adjusting method for NTSC model:
Before perform the LCD system adjustments, check that the data Order Page Address Data Procedure
of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”. 1 0 01 01
2 3 03 FF
Note 1: Taken an extreme care not to destroy the liquid crystal 3 3 71 01 Press PAUSE (Write) button.
display module by static electricity when replacing it.
Note 2: Set the “LCD BRIGHT”, “LCD COLOR” to the center 4 C 65 00 Press PAUSE (Write) button.
with the menu settings of the touch panel. 5 3 01 5A Press PAUSE (Write) button.
Note 3: Open the LCD panel during the LCD system adjustment. (Note 4)
6 3 02 Check the data changes to “00”.
1. LCD Automatic Adjustment (PP-003 board)
7 3 03 Check the data is “00”. (Note 2)
RadarW
8 C 45 Read the data and this data is
This adjustment does the following items automatically.
named D45.
VCO Adjustment
Contrast Adjustment Convert D45 to decimal
9 notation, and obtain D45’.
Mode VTR stop (VCR mode) (Note 3)
Signal No signal Calculate D46’ using
Adjustment Page C 10 following equations.
Adjustment Address 45, 46 (VCO Adjustment) (decimal calculation)
D46’ = D45’ + 10
4D, 76 (Contrast Adjustment)
Convert D46’ to a hexadeci-
Note 1: Check that the data of page: 0, address: 10 is “00”. 11 mal number, and obtain D46.
Note 2: If the data change to “01”, adjustment has error. Con- (Note 3)
tents of error is written into page: 3, address: C6. See the
12 C 46 D46 Press PAUSE (Write) button.
following table.
13 C 4D Read the data and this data is
Data of page: 3, address: C6 Contents of error named D4D.
58 VCO adjustment error 14 C 76 D4D Press PAUSE (Write) button.
60 Contrast adjustment error 15 3 70 10 Press PAUSE (Write) button.
Note 3: Refer to Table 6-4-1. “Hexadecimal-decimal conversion 16 3 70 Check the data changes to “11”.
table”. 17 0 01 00
Note 4: The adjustment data will be automatically input to page:
C, address: 45 and 4D.

HDR-FX7/FX7E_ADJ
6-82
Adjusting method for PAL model: 2. V-COM Adjustment (PP-003 board)
Set the DC bias of the common electrode drive signal of LCD to
Order Page Address Data Procedure
the specified value.
1 0 01 01 If deviated, the LCD display will be move, producing flicker and
2 3 03 FF conspicuous vertical lines.
3 3 71 01 Press PAUSE (Write) button. Mode VTR stop (VCR mode)
4 C 65 00 Press PAUSE (Write) button. Signal No signal
5 3 01 5A Press PAUSE (Write) button. Measurement Point Check on LCD screen
(Note 5) Measuring Instrument
6 3 02 Check the data changes to “00”. Adjustment Page C
7 3 03 Check the data is “00”. (Note 2) Adjustment Address 47
8 C 46 Read the data and this data is Specified Value The brightness difference between
named D46. the section-A and section-B is
Convert D46 to decimal minimum
9 notation, and obtain D46’.
Note 1: Perform “LCD Automatic Adjustment” before this ad-
(Note 3)
justment.
Calculate D45’ using Note 2: Check that the data of page: 0, address: 10 is “00”.
10 following equations.
(decimal calculation) Switch setting
D45’ = D46’ − 10 LCD BACKLIGHT .................................................................. ON
Convert D45’ to a hexadeci-
11 mal number, and obtain D45. Adjusting method:
(Note 3)
Order Page Address Data Procedure
12 C 45 D45 Press PAUSE (Write) button.
1 0 01 01
13 C 4D Read the data and this data is
2 3 71 01 Press PAUSE (Write) button.
named D4D.
3 C 56 0D Press PAUSE (Write) button.
14 C 76 D4D Press PAUSE (Write) button.
Change the data so that
15 3 70 10 Press PAUSE (Write) button.
4 C 47 brightness of the section A
16 3 70 Check the data changes to “11”. and section B is equal.
17 0 01 00 5 C 47 Press PAUSE (Write) button.
Note 5: The adjustment data will be automatically input to page: 6 C 56 C5 Press PAUSE (Write) button.
C, address: 46 and 4D. 7 3 70 10 Press PAUSE (Write) button.
8 3 70 Check the data changes to “11”.
9 0 01 00

B A

A B

B A

A B

Fig. 6-1-30

HDR-FX7/FX7E_ADJ
6-83
3. Transmissive Mode White Balance Adjustment 4. Reflective Mode White Balance Adjustment RadarW
(PP- 003 board) (PP-003 board)
Correct the white balance at transmissive mode. Correct the white balance at reflective mode.
If deviated, the LCD screen color cannot be reproduced. If deviated, the LCD screen color cannot be reproduced.
Mode VTR stop (VCR mode) Mode VTR stop (VCR mode)
Signal No signal Signal No signal
Measurement Point Check on LCD screen Adjustment Page C
Measuring Instrument Adjustment Address 70, 71
Adjustment Page C Note 1: Check that the data of page: 0, address: 10 is “00”.
Adjustment Address 4B, 4C
Specified Value LCD screen must not be colored Adjusting method:

Note 1: Check that the data of page: 0, address: 10 is “00”. Order Page Address Data Procedure
Note 2: Check the white balance only when replacing the fol- 1 0 01 01
lowing parts. If necessary, adjust them. 2 3 C4 59
1. LCD block
3 3 C5 02
2. Light induction plate
3. IC9002 4 3 0C 20 Press PAUSE (Write) button.
5 3 22 0F Press PAUSE (Write) button.
Adjusting method:
6 3 71 01 Press PAUSE (Write) button.
Order Page Address Data Procedure 7 3 03 FF
1 0 01 01 Press PAUSE (Write) button.
8 3 01 66
2 3 71 01 Press PAUSE (Write) button. (Note 2)
3 C 4B 8F Press PAUSE (Write) button. 9 3 02 Check the data changes to
4 C 4C 79 Press PAUSE (Write) button. “00”.
Check that the LCD screen is 10 3 03 Check the data is “00”. (Note 4)
5 not colored. If not colored, 11 3 03 FF
proceed to step 7. Press PAUSE (Write) button.
12 3 01 67
Change the data so that the (Note 3)
4B
6 C LCD screen is not colored. Check the data changes to
4C 13 3 02
(Note 3) “00”.
7 3 70 10 Press PAUSE (Write) button. 14 3 03 Check the data is “00”. (Note 4)
8 3 70 Check the data changes to “11”. 15 3 C4 00
9 0 01 00 16 3 C5 00
Note 3: To write in the non-volatile memory (EEPROM), press 17 3 0C 00 Press PAUSE (Write) button.
the PAUSE (Write) button each time to set the data. 18 3 22 00 Press PAUSE (Write) button.
The data of page: C, address: 4B should be “5C” to “A6”.
The data of page: C, address: 4C should be “51” to “97”. 19 3 70 10 Press PAUSE (Write) button.

20 3 70 Check the data changes to


“11”.
21 0 01 00
Note 2: The adjustment data will be automatically input to page:
C, address: 70.
Note 3: The adjustment data will be automatically input to page:
C, address: 71.
Note 4: If the data is “01”, adjustment has error.

HDR-FX7/FX7E_ADJ
6-84
5. Sample Hold Phase Adjustment (PP-003 board)
Set the sampling hold timing of the LCD panel to optimum tim-
ing.
Mode VTR stop (VCR mode)
Signal No signal
Measurement Point Check on LCD screen
Measuring Instrument
Adjustment Page C
Adjustment Address 54
Specified Value The LCD screen is brightest
Note 1: Perform “LCD Automatic Adjustment” and “V-COM
Adjustment” before this adjustment.
Note 2: Check that the data of page: 0, address: 10 is “00”.

Switch setting
LCD BACKLIGHT .................................................................. ON

Adjusting method:
Order Page Address Data Procedure
1 0 01 01
2 3 71 01 Press PAUSE (Write) button.
3 3 0C 20 Press PAUSE (Write) button. A
4 3 22 0F Press PAUSE (Write) button.
5 C 55 01 Press PAUSE (Write) button. B
Set the following data, one
by one, and investigate which
6 C 54 data makes the LCD screen
the brightest.
1F, 3F, 5F, 7F, 9F, BF Fig. 6-1-31
Set the data which made the
7 C 54 LCD screen the brightest.
This data named Dadj.
8 C 54 Press PAUSE (Write) button.
9 C 55 03 Press PAUSE (Write) button.
Set the data which subtracted
10 C 54 20 from Dadj.
(hexadecimal calculation)
(Note 3)
Check that the 2nd position
11 A or 3rd position B of the
LCD screen is the brightest.
(Fig. 6-1-31)
12 C 54 Dadj Press PAUSE (Write) button.
13 3 0C 00 Press PAUSE (Write) button.
14 3 22 00 Press PAUSE (Write) button.
15 C 55 CC Press PAUSE (Write) button.
16 3 70 10 Press PAUSE (Write) button.

17 3 70 Check the data changes to


“11”.
18 0 01 00
Note 3: For example.
When Dadj is “BF”, data is “9F”.
When Dadj is “5F”, data is “3F”.
However, when Dadj is “1F”, data is “BF”.

HDR-FX7/FX7E_ADJ
6-85
6-2. MECHANISM SECTION ADJUSTMENTS

On the mechanism section adjustment


For details of mechanism section adjustments, checks, and replace-
ment of mechanism parts, refer to the separate volume “DV ME-
CHANICAL ADJUSTMENT MANUAL IX N Mechanism ”.

2-1. HOW TO ENTER RECORD MODE CN1014 of TT-003 board


WITHOUT CASSETTE Pin No. Signal Name Pin No. Signal Name
1) Connect the adjustment remote commander to the LANC jack. 1 EVF_COM_DC 9 RF_MON
2) Turn the HOLD switch of the adjustment remote commander 2 REG_GND 10 REG_GND
to the ON position. 3 EXT_DA 11 SWP
3) Close the cassette compartment without the cassette.
4) Select page: 3, address: 01, set data: 0C, and press the PAUSE 4 EVF_VCO 12 FRRV
(Write) button of the adjustment remote commander. 5 EVF_VG 13 REC_CRRT1_S
(The mechanism enters the record mode automatically.) 6 PSIG 14 REC_CRRT0_S
Note: The function buttons become inoperable.
7 REG_GND 15 REC_CRRT1_C
5) To quit the record mode, select page: 3, address: 01, set data:
00, and press the PAUSE (Write) button of the adjustment re- 8 REG_GND 16 REC_CRRT0_C
mote commander. (Whenever you want to quit the record
mode, be sure to quit following this procedure.) 2. Procedure after operations
1) Connect the adjustment remote commander to the LANC jack
2-2. HOW TO ENTER PLAYBACK MODE and set the HOLD switch to the ON position.
WITHOUT CASSETTE 2) Select page: 3, address: 26, set data: 00, and press the PAUSE
(Write) button.
1) Connect the adjustment remote commander to the LANC jack. 3) Select page: 3, address: 33, and set data: 00.
2) Turn the HOLD switch of the adjustment remote commander
to the ON position.
Entrance side Check this section Exit side
3) Close the cassette compartment without the cassette. (Normal waveform)
4) Select page: 3, address: 01, set data: 0B, and press the PAUSE
(Write) button of the adjustment remote commander.
(The mechanism enters the playback mode automatically.)
Note: The function buttons become inoperable.
5) To quit the playback mode, select page: 3, address: 01, set CH1
data: 00, and press the PAUSE (Write) button of the adjust-
ment remote commander. (Whenever you want to quit the play-
back mode, be sure to quit following this procedure.)

2-3. TAPE PATH ADJUSTMENT

1. Preparation for Adjustment CH2


1) Clean the tape running side (tape guide, drum, capstan shaft, (Trigger)
pinch roller, etc.). 3.3 msec
2) Connect the adjustment remote commander to the LANC jack.
3) Turn the HOLD switch of the adjustment remote commander Fig. 6-2-1
to the ON position.
4) Connect an oscilloscope to TT-003 board CN1014 via the CPC-
7 jig (J-6082-382-A).
Channel 1: TT-003 board, CN1014 Pin 9 (Note)
External trigger: TT-003 board, CN1014 Pin qa
Note: Connect a 75 Ω resistor between pins 9 of CN7005
and 8 (GND).
75 Ω resistor (Parts code: 1-247-804-11)
5) Playback the alignment tape for tracking. (XH2-1)
6) Select page: 3, address: 33, and set data: 08.
7) Select page: 3, address: 26, set data: 31, and press the PAUSE
(Write) button.
8) Check that the oscilloscope RF waveform is normal at the en-
trance and exit.
If not normal, adjust according to the separate volume
“DV MECHANICAL ADJUSTMENT MANUAL IX
N Mechanism ” .

HDR-FX7/FX7E_ADJ
6-86
6-3. VIDEO SECTION ADJUSTMENTS

3-1. PREPARATIONS BEFORE ADJUSTMENTS

3-1-1. Precautions on Adjusting 3-1-2. Adjusting Connectors


Note: Before performing the adjustment, check the data of page: The measuring point of the playback RF signal is CN1014 of TT-
0, address: 10 is “00”. If not, select page: 0, address: 00, 003 board. Connect the measuring instruments via the CPC-7 jig
and set data “00”. (J-6082-382-A). Refer to “MECHANISM SECTION ADJUST-
MENT” for the measuring method. The following table lists the
1) The adjustments of this unit are performed in the VTR mode pin numbers and signal names of CN1014.
(PLAY/EDIT mode) or camera mode (CAMERA-TAPE
Pin No. Signal Name Pin No. Signal Name
mode).
1 EVF_COM_DC 9 RF_MON
2 REG_GND 10 REG_GND
3 EXT_DA 11 SWP
4 EVF_VCO 12 FRRV
5 EVF_VG 13 REC_CRRT1_S
6 PSIG 14 REC_CRRT0_S
7 REG_GND 15 REC_CRRT1_C
8 REG_GND 16 REC_CRRT0_C
Table 6-3-1

3-1-3. Connecting the Equipment


Connect the measuring instruments as shown in Fig. 6-3-1, and
perform the adjustments.

Adjustment remote commander

NEW LANC JIG RM-95 VIDEO system adjustment (COMPONENT OUT)


(J-6082-565-A) (J-6082-053-B)
Osilloscope
LANC cable
(J-6082-442-A) Y (Green)
Terminated
Pr (Red) 75 Ω

Pb (Blue)
TT-003 board

VIDEO system adjustment (S VIDEO, VIDEO)


16
Osilloscope
CN1014 1 S Video
(Black)
Terminated
75 Ω
Video
(Yellow)

LANC jack

16
CPC-7 jig COMPONENT
(J-6082-382-A) OUT jack
1
A/V jack Audio L (White)
DC IN jack
Audio R (Red)

AC IN
AC adaptor
AC-L15A
(1-479-283-13)

Fig. 6-3-1

HDR-FX7/FX7E_ADJ
6-87
3-1-4. Alignment Tapes
Use the alignment tapes shown in the following table.
Use tapes specified in the signal column of each adjustment.
Name Use
Tracking standard (XH2-1) Tape path adjustment
Switching position adjust-
SW/OL standard (XH2-3)
ment
Audio operation check
Audio system adjustment
(XH5-3 (NTSC), XH5-3P (PAL))
System operation check
Operation check
(XH5-5 (NTSC), XH5-5P (PAL))
Fig. 6-3-2 shows the 75% color bar signals recorded on the align-
ment tape for Audio Operation Check.

Note: Measure with video terminal (Terminated at 75 Ω)

For NTSC model White (100%)


Yellow

Cyan

Magenta
Green

White (75%)

Magenta
Red

White
Blue

Burst signal

Yellow

Green
Cyan

Red

Blue
0.714 V
(75%)
1V
0.286 V
0.286 V Q I Black
Q I

White
Horizontal sync signal (100%)

Color bar signal waveform Color bar pattern

For PAL model

White (100%)
Yellow

Green
Cyan

Magenta
Red
Blue

0.7 V
Magenta
Green
Yellow

1V
Cyan
White

Red
Blue
Black

0.3 V
0.3 V (100%)

Burst signal
Horizontal sync signal
Color bar signal waveform Color bar pattern

Fig. 6-3-2 Color bar signal of alignment tapes

3-1-5. Output Level and Impedance


Audio/Video output COMPONENT OUT jack
10-pin connector Y: 1 Vp-p, 75 Ω (ohms), unbalanced PB/PR, CB/CR: +/- 350 mVp-p
Video signal: 1 Vp-p, 75 Ω (ohms), unbalanced
Luminance si gnal : 1 Vp-p, 75 Ω (ohms), unbalanced
Chrominance signal: 0.286 Vp-p, 75 Ω (ohms), unbalanced (NTSC)
Chrominance signal: 0.3 Vp-p, 75 Ω (ohms), unbalanced (PAL)
Audio si gna l: 327 mV (at load impedance 47 kΩ (kilohms)),
Output impedance with less than 2.2 kΩ (kilohms)

HDR-FX7/FX7E_ADJ
6-88
3-2. SYSTEM CONTROL SYSTEM ADJUSTMENTS D1 (decimal) D2 (decimal) H1 (hexadecimal)
(Service model code)
1. Initialization of EEPROM Data
00001 to 65535 D1 FE
If the EEPROM data is erased due to some reason, perform “1-2.
INITIALIZATION OF EEPROM DATA ”, of “6-1. CAMERA 65536 to 131071 D1 − 65536 FE
SECTION ADJUSTMENTS” 131072 to196607 D1 − 131072 FE
196608 to 262143 D1 − 196608 FE
2. Node Unique ID No. Input
Note 1: Perform “2-2. Input of Serial No.” if the data on page 13 262144 to 327679 D1 − 262144 FE
has been cleared and original node unique ID No. is un- 327680 to 393215 D1 − 327680 FE
certain. 393216 to 458751 D1 − 393216 FE
Usually, read the data on page 13 before repair, and write
it after repair. 458752 to 524287 D1 − 458752 FE
Note 2: If reading/writing data on pages 13, set data: 01 to page: 524288 to 589823 D1 − 524288 FE
0, address: 10, and then select pages: 3. By this data set- 589824 to 655359 D1 − 589824 FE
ting, the pages 13 can be selected.
After the data reading/writing finished, return the data 655360 to 720895 D1 − 655360 FE
on page: 0, address: 10 to “00”. 720896 to 786431 D1 − 720896 FE
786432 to 851967 D1 − 786432 FE
2-1. Input of Company ID
Write the company ID to the EEPROM (nonvolatile memory). 851968 to 917503 D1 − 851968 FE
917504 to 983039 D1 − 917504 FE
Page 13
983040 to 999999 D1 − 983040 FE
Address 04, 05, 06, 07, 08
Table 6-3-2
Input method:
1) Select page: 0, address: 01, and set data: 01. 5) Enter H1 to address: 09 on page: 13.
2) Select page: 3, address: 71, and set data: 01, then press the Example: If H1 = FE,
PAUSE (Write) button. Select page: 0, address: 10, and set data: 01.
3) Select page: 0, address: 10, and set data: 01. Select page: 3 (13), address: 09, and set data: FE, then press
4) Select page: 3 (13), and enter the following data. the PAUSE (Write) button.
Note 3: Each time the data is set, press the PAUSE (Write) but- 6) From Table 6-3-3, obtain the maximum decimal number less
ton on the adjusting remote commander. than D2, and it is assumed to be D3.
Example: If D2 = 12345.
Address Data D3 = 12288
04 08 7) From Table 6-3-3, obtain a hexadecimal number that corre-
05 00 sponds to D3, and it is assumed to be H3.
Example: If D3 = 12288,
06 46
H3 = 3000
07 01 8) Caluculate D 4 using following equations (decimal
08 02 caluculation). (0 D4 225)
D 4 = D2 – D 3
5) Select page: 0, address: 10, and set data: 00. Example: If D2 = 12345 and D3 = 12288,
6) Select page: 3, address: 70, and set data: 10, then press the D4 = 12345 – 12288 = 57
PAUSE (Write) button. 9) Convert D4 into a hexadecimal number to obtain H4. (See Table
7) Select page: 3, address: 70, and check that the data changes to 6-4-1 “Hexadecimal - decimal conversion table” in 6-4. Ser-
“11”. vice Mode)
8) Select page: 0, address: 01, and set data: 00. Example: If D4 = 57,
H4 = 39
2-2. Input of Serial No. 10) Enter higher two digits of H3 to address: 0A on page: 13.
Write the serial No. and model code to the EEPROM (nonvolatile Example: If H3 = 3000,
memory). Select page: 0, address: 10, and set data: 01.
In writing the serial No., a decimal number should be converted Select page: 3 (13), address: 0A, and set data: 30, then press
into a hexadecimal number the PAUSE (Write) button.
Page 13 11) Enter H4 to address: 0B on page: 13.
Example: If H4 = 39,
Address 09, 0A, 0B
Select page: 0, address: 10, and set data: 01.
1) Select page: 0, address: 01, and set data: 01. Select page: 3 (13), address: 0B, and set data: 39, then press
2) Select page: 3, address: 71, and set data: 01, then press the the PAUSE (Write) button.
PAUSE (Write) button. 12) Select page: 0, address: 10, and set data: 00.
3) Read the serial No. from the model name label, and it is as- 13) Select page: 3, address: 70, and set data: 10, then press the
sumed to be D1. PAUSE (Write) button.
Example: If serial No. is “77881”, 14) Select page: 3, address: 70, and check that the data changes to
D1 = 77881 “11”.
4) From Table 6-3-2, obtain D2 and H1 that correspond to D1. 15) Select page: 0, address: 01, and set data: 00.
Example: If D1 = 77881,
D2 = D1 – 65536 = 12345
H1 = FE
HDR-FX7/FX7E_ADJ
6-89
D3 H3 D3 H3 D3 H3 D3 H3 D3 H3 D3 H3 D3 H3 D3 H3
0 0000 8192 2000 16384 4000 24576 6000 32768 8000 40960 A000 49152 C000 57344 E000
256 0100 8448 2100 16640 4100 24832 6100 33024 8100 41216 A100 49408 C100 57600 E100
512 0200 8704 2200 16896 4200 25088 6200 33280 8200 41472 A200 49664 C200 57856 E200
768 0300 8960 2300 17152 4300 25344 6300 33536 8300 41728 A300 49920 C300 58112 E300
1024 0400 9216 2400 17408 4400 25600 6400 33792 8400 41984 A400 50176 C400 58368 E400
1280 0500 9472 2500 17664 4500 25856 6500 34048 8500 42240 A500 50432 C500 58624 E500
1536 0600 9728 2600 17920 4600 26112 6600 34304 8600 42496 A600 50688 C600 58880 E600
1792 0700 9984 2700 18176 4700 26368 6700 34560 8700 42752 A700 50944 C700 59136 E700
2048 0800 10240 2800 18432 4800 26624 6800 34816 8800 43008 A800 51200 C800 59392 E800
2304 0900 10496 2900 18688 4900 26880 6900 35072 8900 43264 A900 51456 C900 59648 E900
2560 0A00 10752 2A00 18944 4A00 27136 6A00 35328 8A00 43520 AA00 51712 CA00 59904 EA00
2816 0B00 11008 2B00 19200 4B00 27392 6B00 35584 8B00 43776 AB00 51968 CB00 60160 EB00
3072 0C00 11264 2C00 19456 4C00 27648 6C00 35840 8C00 44032 AC00 52224 CC00 60416 EC00
3328 0D00 11520 2D00 19712 4D00 27904 6D00 36096 8D00 44288 AD00 52480 CD00 60672 ED00
3584 0E00 11776 2E00 19968 4E00 28160 6E00 36352 8E00 44544 AE00 52736 CE00 60928 EE00
3840 0F00 12032 2F00 20224 4F00 28416 6F00 36608 8F00 44800 AF00 52992 CF00 61184 EF00
4096 1000 12288 3000 20480 5000 28672 7000 36864 9000 45056 B000 53248 D000 61440 F000
4352 1100 12544 3100 20736 5100 28928 7100 37120 9100 45312 B100 53504 D100 61696 F100
4608 1200 12800 3200 20992 5200 29184 7200 37376 9200 45568 B200 53760 D200 61952 F200
4864 1300 13056 3300 21248 5300 29440 7300 37632 9300 45824 B300 54016 D300 62208 F300
5120 1400 13312 3400 21504 5400 29696 7400 37888 9400 46080 B400 54272 D400 62464 F400
5376 1500 13568 3500 21760 5500 29952 7500 38144 9500 46336 B500 54528 D500 62720 F500
5632 1600 13824 3600 22016 5600 30208 7600 38400 9600 46592 B600 54784 D600 62976 F600
5888 1700 14080 3700 22272 5700 30464 7700 38656 9700 46848 B700 55040 D700 63232 F700
6144 1800 14336 3800 22528 5800 30720 7800 38912 9800 47104 B800 55296 D800 63488 F800
6400 1900 14592 3900 22784 5900 30976 7900 39168 9900 47360 B900 55552 D900 63744 F900
6656 1A00 14848 3A00 23040 5A00 31232 7A00 39424 9A00 47616 BA00 55808 DA00 64000 FA00
6912 1B00 15104 3B00 23296 5B00 31488 7B00 39680 9B00 47872 BB00 56064 DB00 64256 FB00
7168 1C00 15360 3C00 23552 5C00 31744 7C00 39936 9C00 48128 BC00 56320 DC00 64512 FC00
7424 1D00 15616 3D00 23808 5D00 32000 7D00 40192 9D00 48384 BD00 56576 DD00 64768 FD00
7680 1E00 15872 3E00 24064 5E00 32256 7E00 40448 9E00 48640 BE00 56832 DE00 65024 FE00
7936 1F00 16128 3F00 24320 5F00 32512 7F00 40704 9F00 48896 BF00 57088 DF00 65280 FF00
Note: D3: Decimal
H3: Hexadecimal
Table 6-3-3

HDR-FX7/FX7E_ADJ
6-90
3-3. SERVO AND RF SYSTEM ADJUSTMENTS 1. CAP FG Duty Adjustment (TT-003 board)
Before perform the servo and RF system adjustments, check that RadarW
the specified values of “Origin Oscillation check” of “1-3. CAM- Set the CAP FG signal duty cycle to 50% to establish an appropri-
ERA SYSTEM ADJUSTMENTS” is satisfied. ate capstan servo. If deviated, the uneven rotation of capstan and
Check that the data of page: 0, address: 10 is “00”. If not, select noise can occur.
page: 0, address: 10, and set the data “00”.
Mode VTR stop (VCR mode)
Adjusting Procedure: Signal No signal
1. CAP FG duty adjustment
Measurement Point Displayed data of page: 3, address:
2. Switching position adjustment
03
3. Error rate check
Measuring Instrument Adjusting remote commander
Adjustment Page C
Adjustment Address 16
Specified value The data of page: 3, address: 03 is
“00”
Note 1: Check that the data of page: 0, address: 10 is “00”.

Adjusting method:
Order Page Address Data Procedure
Close the cassette compart-
1 ment without inserting
cassette.
2 0 01 01
3 3 03 FF
4 3 71 01 Press PAUSE (Write) button.
5 3 01 1B Press PAUSE (Write) button.
Check the data changes in
6 3 02 the following order
“1B” t “2B” t “00”
7 3 03 Check the data is “00”. (Note 2)
8 3 70 10 Press PAUSE (Write) button.

9 3 70 Check the data changes to


“11”.
10 0 01 00
Note 2: If the data is “01”, adjustment has errors or the mecha-
nism deck is defective.
If the data is “80”, the mechanism deck is in emergency
state or the end of tape was detected.

HDR-FX7/FX7E_ADJ
6-91
2. Switching Position Adjustment (TT-003 board) Note 3: If bit0 of the data is “1”, the EVEN channel is defective.
RadarW If bit1 of the data is “1”, the ODD channel is defective.
Contents of the defect is see written into page: C, ad-
Mode VTR playback (VCR mode) dress: 10 and 12. See following table.
(For the bit values, refer to “6-4. SERVICE MODE”,
Signal SW/OL standard (XH2-3)
“4-4. 3. Bit value discrimination”.)
Measurement Point Displayed data of page: 3, address: If bit3 of the data is “1”, the tape end being played, so
03 rewind the tape and perform the adjustment again.
Measuring Instrument Adjusting remote commander
When the EVEN channel is defective
Adjustment Page C
Adjustment Address 10, 11, 12, 13 Data of page: C, Contents of defect
address: 10
Specified value The data of page: 3, address: 03 is
“00” EE Writing into Flash memory (IC2402) is
defective
Note 1: Check that the data of page: 0, address: 10 is “00”.
E8 Adjustment data is out of range
Adjusting method: E7 No data is returned from IC2801

Order Page Address Data Procedure


When the ODD channel is defective
Insert the SW/OL standard
1 tape and enter the VTR stop Data of page: C, Contents of defect
mode. address: 12
2 0 01 01 Writing into Flash memory (IC2402) is
EE
3 3 71 01 Press PAUSE (Write) button. defective
4 C 10 EE Press PAUSE (Write) button. E8 Adjustment data is out of range
5 3 03 FF E7 No data is returned from IC2802
6 3 21 Check the data is “02”. (Note 2)
7 3 01 0D Press PAUSE (Write) button.
8 3 02 Check the data changes to “00”.
9 3 03 Check the data is “00”. (Note 3)
10 3 70 10 Press PAUSE (Write) button.

11 3 70 Check the data changes to


“11”.
12 0 01 00
Note 2: If the data is “72”, the tape top being played. After play-
ing the tape for 1 to 2 seconds, stop it, perform step 5 and
higher.
If the data is “62”, the tape end being played. After re-
wind the tape, perform step 5 and higher.

HDR-FX7/FX7E_ADJ
6-92
3. Error Rate Check (TT-003 board) RadarW Adjusting method:
Note: Check that the data of page: 0, address: 10 is “00”.
Order Page Address Data Procedure
3-1. Preparations before adjustments 1 0 01 01

Mode Camera recording (CAMERA mode) 2 3 71 01 Press PAUSE (Write) button.

Subject Arbitrary Check that the data of page:


3 1C, address: B3 to C8 is the
initial value. (See Table 6-3-
Switch setting 4)
1) REC FORMAT (Menu setting) ......................................... DV Playback the recorded signal
4 at “Preparations before
Adjusting method: adjustments”.
Order Page Address Data Procedure 5 3 03 FF
1 0 01 01 6 3 01 40 Press PAUSE (Write) button.
2 3 71 01 Press PAUSE (Write) button. Check the data changes to
7 3 02
3 0 10 01 “00”.
C 8 3 03 Check the data is “00”. (Note 2)
4 0D C8 Press PAUSE (Write) button.
(1C) Perform “Processing after
9
5 0 10 00 Completing Adjustments”.

6 Record the camera signal for Note 2: If the data is other than “00”, Error rate is abnormal.
2 minutes. For the contents of the abnormality, see the following
table.
3-2. Error Rate Check Data of page: 3, Contents of defect
address: 03
Mode VTR playback (VCR mode)
Subject Recorded signal at “Preparations 01 EVEN channel is abnormal.
before adjustments” 02 ODD channel is abnormal.
Measurement Point Displayed data of page: 3, address: 03 EVEN channel and ODD channel are
03 abnormal.
Measuring Instrument Adjusting remote commander Note 3: If Error rate is abnormal, Check the use tape, clean the
Adjustment Page 1C tape running surface. And after inputting initial values to
page 1C: address: B3 to C8, perform re-adjustment. (See
Adjustment Address B3 to C8
Table 6-3-4)
Specified value The data of page: 3, address: 03 is
“00” Processing after Completing Adjustment:
Note 1: If reading/writing data on pages 1C, set data: 01 to page: Order Page Address Data Procedure
0, address: 10, and then select pages: C. By this data set-
1 0 01 01
ting, the pages 1C can be selected.
After the data reading/writing finished, return the data 2 0 10 01
on page: 0, address: 10 to “00”. C
3 0D 00 Press PAUSE (Write) button.
(1C)
Initial Value of Page 1C: Address: B3 to C8
4 0 10 00
Address Initial Address Initial Address Initial 5 3 70 10 Press PAUSE (Write) button.
value value value
6 3 70 Check the data changes to
B3 00 BB 00 C3 80 “11”.
B4 00 BC 00 C4 00 7 0 01 00
B5 00 BD 00 C5 00
B6 00 BE 00 C6 00
B7 00 BF 00 C7 00
B8 80 C0 00 C8 00
B9 00 C1 00
BA 00 C2 00
Table 6-3-4

HDR-FX7/FX7E_ADJ
6-93
3-4. VIDEO SYSTEM ADJUSTMENTS 1-2. S VIDEO OUT Y Level Adjustment (TT-003 board)
Before perform the video system adjustments, check that the speci- Mode VCR
fied values of “Origin Oscillation Check” of “1-3. CAMERA SYS-
TEM ADJUSTMENTS” is satisfied. Signal No signal
Check that the data of page: 0, address: 10 is “00”. Measurement Point Y signal terminal of S VIDEO plug
If not, select page: 0, address: 10, and set the data “00”. of A/V jack (75 Ω terminated)
Measuring Instrument Oscilloscope
Adjusting Procedure:
1. S VIDEO OUT Y level adjustment Adjustment Page C
2. S VIDEO OUT chroma level adjustment Adjustment Address 25 (NTSC)
3. VIDEO OUT level check 85 (PAL)
4. COMPONENT OUT Y level adjustment Specified value A = 1000 ± 14 mVp-p
5. COMPONENT OUT Pr level adjustment
6. COMPONENT OUT Pb level adjustment
Adjusting method:
1. S VIDEO, VIDEO OUT Adjustment Order Page Address Data Procedure
1-1. Preparations
Perform the following data setting before the “S VIDEO, 1 Perform “Preparations”.
VIDEO OUT Adjustment”. (NTSC)
Change the data and set the Y
25
Order Page Address Data Procedure 2 C signal level (A) to the
(PAL) specified value.
1 Set the unit to VCR mode. 85
2 0 01 01 (NTSC)
3 3 71 01 Press PAUSE (Write) button. 25
3 C Press PAUSE (Write) button.
4 0 10 01 (PAL)
85
5 8 00 01 Press PAUSE (Write) button.
4 Perform “Processing after
(18)
Complete Adjustment”.
6 8 01 60 Press PAUSE (Write) button.
(18)

7 C 0F 10 Press PAUSE (Write) button.


(1C)

8 8 06 55 Press PAUSE (Write) button.


(18) A

9 8 04 C0 Press PAUSE (Write) button.


(18)
10 0 10 00
11 Wait for 5 sec.
12 0 FF 3E H
13 B 00 02
Fig. 6-3-3
14 C 85 Check the data is “55”.
15 B 00 00
16 0 FF 00

HDR-FX7/FX7E_ADJ
6-94
1-3. S VIDEO OUT Chroma Level Adjustment
(TT-003 board)
H
Mode VCR
Signal No signal
Measurement Point Chroma signal terminal of S VIDEO
plug of A/V jack (75 Ω terminated) C
External trigger: Y signal terminal of
S VIDEO plug of A/V jack (75 Ω
terminated)
Measuring Instrument Oscilloscope
Adjustment Page C
Adjustment Address 26, 27 (NTSC)
86, 87 (PAL) A B

Specified value Cr level: A = 714 ± 14 mVp-p(NTSC)


A = 700 ± 14 mVp-p (PAL)
Cb level: B = 714 ± 14 mVp-p(NTSC) 0.28 µsec (NTSC) 0.28 µsec (NTSC)
B = 700 ± 14 mVp-p(PAL) 0.23 µsec (PAL) 0.23 µsec (PAL)
Burst level: C = 286 ± 6 mVp-p(NTSC)
Fig. 6-3-4
C = 300 ± 6 mVp-p(PAL)

Adjusting method:
Order Page Address Data Procedure
1 Peform “Preparations”.
(NTSC)
Change the data and set the
26
2 C Cr signal level (A) to the
(PAL) specified value.
86
(NTSC)
26
3 C Press PAUSE (Write) button.
(PAL)
86
(NTSC)
Change the data and set the
27
4 C Cb signal level (B) to the
(PAL) specified value.
87
(NTSC)
27
5 C Press PAUSE (Write) button.
(PAL)
87

6 Check the burst signal (C) to


the specified value.

7 Perform “Processing after


Complete Adjustment”.

HDR-FX7/FX7E_ADJ
6-95
1-4. VIDEO OUT Level Check (TT-003 board) 1-5. Processing after Complete Adjustment
Perform the setting through the procedure mentioned below when
Mode VCR
you finish the “S VIDEO, VIDEO OUT Adjustment”.
Signal No signal
Order Page Address Data Procedure
Measurement Point Video terminal of A/V jack (75 Ω
terminated) 1 0 10 01
Measuring Instrument Oscilloscope 2 C 0F 00 Press PAUSE (Write) button.
(1C)
Specified value Sync level: A = 286 ± 18 mVp-p(NTSC)
A = 300 ± 18 mVp-p(PAL) 3 8 04 80 Press PAUSE (Write) button.
Burst level: B = 286 ± 18 mVp-p(NTSC) (18)
B = 300 ± 18 mVp-p(PAL) 4 8 00 00 Press PAUSE (Write) button.
(18)
Checking method: 5 8 01 00 Press PAUSE (Write) button.
(18)
Order Page Address Data Procedure
6 8 06 00 Press PAUSE (Write) button.
1 Peform “Preparations” (18)
2 Check the sync signal level 7 0 10 00
(A) to the specified value.
8 3 70 10 Press PAUSE (Write) button.
3 Check the burst signal level
9 3 70 Check the data changes to
(B) to the specified value.
“11”.
4 Perform “Processing after
10 0 01 00
Complete Adjustment”.

B
A

Fig. 6-3-5

HDR-FX7/FX7E_ADJ
6-96
2. COMPONENT OUT Y Level Adjustment 3. COMPONENT OUT Pr Level Adjustment
(TT-003 board) (TT-003 board)
Mode CAMERA Mode CAMERA
Subject Arbitrary Subject Arbitrary
Measurement Point Y signal terminal of COMPONENT Measurement Point Pr signal terminal of COMPONENT
OUT jack (75 Ω terminated) OUT jack (75 Ω terminated)
Measuring Instrument Oscilloscope Measuring Instrument Oscilloscope
Adjustment Page C Adjustment Page C
Adjustment Address 93 Adjustment Address 95
Specified value Y level: A = 1000 ± 10 mVp-p Specified value Pr level: A = 525 ± 10 mVp-p
Sync level: B = C = 300 ± 10 mVp-p Sync level: B = C = 300 ± 10 mVp-p

Switch setting: Switch setting:


1) REC FORMAT (Menu setting) ............................. HDV1080i 1) REC FORMAT (Menu setting) ............................. HDV1080i

Adjusting method: Adjusting method:


Order Page Address Data Procedure Order Page Address Data Procedure
1 0 01 01 1 0 01 01
2 3 71 01 Press PAUSE (Write) button. 2 3 71 01 Press PAUSE (Write) button.
3 0 10 01 3 0 10 01
Set the bit value of bit7 is Set the bit value of bit7 is
4 8 00 4 8 00
“1”, and press PAUSE “1”, and press PAUSE
(18) (18)
(Write) button. (Note) (Write) button. (Note)
5 0 10 00 5 0 10 00
Change the data and set the Change the data and set the
6 C 93 Y signal level (A) to the 6 C 95 Pr signal level (A) to the
specified value. specified value.
7 C 93 Press PAUSE (Write) button. 7 C 95 Press PAUSE (Write) button.

8 Check the sync signal (B, C) 8 Check the sync signal (B, C)
to the specified value. to the specified value.
9 0 10 01 9 0 10 01
Set the bit value of bit7 is Set the bit value of bit7 is
10 8 00 10 8 00
“0”, and press PAUSE “0”, and press PAUSE
(18) (18)
(Write) button. (Note) (Write) button. (Note)
11 0 10 00 11 0 10 00
12 3 70 10 Press PAUSE (Write) button. 12 3 70 10 Press PAUSE (Write) button.

13 3 70 Check the data changes to 13 3 70 Check the data changes to


“11”. “11”.
14 0 01 00 14 0 01 00
Note: For the bit values, refer to “6-4. SERVICE MODE”, Note: For the bit values, refer to “6-4. SERVICE MODE”, “ 4 - 4 .
“4-4. 3. Bit value discrimination”. 3. Bit value discrimination”.

B
A
C
A
B
H
C
Fig. 6-3-7
H

Fig. 6-3-6

HDR-FX7/FX7E_ADJ
6-97
4. COMPONENT OUT Pb Level Adjustment
(TT-003 board)
Mode CAMERA
Subject Arbitrary
Measurement Point Pb signal terminal of COMPONENT
OUT jack (75 Ω terminated)
Measuring Instrument Oscilloscope
Adjustment Page C
Adjustment Address 94
Specified value Pb level: A = 525 ± 10 mVp-p
Sync level: B = C = 300 ± 10 mVp-p

Switch setting:
1) REC FORMAT (Menu setting) ............................. HDV1080i

Adjusting method:
Order Page Address Data Procedure
1 0 01 01
2 3 71 01 Press PAUSE (Write) button.
3 0 10 01
Set the bit value of bit7 is
4 8 00 “1”, and press PAUSE
(18)
(Write) button. (Note)
5 0 10 00
Change the data and set the
6 C 94 Pb signal level (A) to the
specified value.
7 C 94 Press PAUSE (Write) button.

8 Check the sync signal (B, C)


to the specified value.
9 0 10 01
Set the bit value of bit7 is
10 8 00 “0”, and press PAUSE
(18)
(Write) button. (Note)
11 0 10 00
12 3 70 10 Press PAUSE (Write) button.

13 3 70 Check the data changes to


“11”.
14 0 01 00
Note: For the bit values, refer to “6-4. SERVICE MODE”, “4-4.
3. Bit value discrimination”.

B
A
C

Fig. 6-3-8

HDR-FX7/FX7E_ADJ
6-98
3-5. AUDIO SYSTEM ADJUSTMENTS 1. Playback Level Check
Mode VTR playback (VCR mode)
[Connecting the measuring instruments for the audio]
Connect the audio system measuring instruments in addition to Alignment tape:
the video system measuring instruments as shown in Fig. 6-3-9. Signal For audio operation check
(XH5-3 (NTSC))
(XH5-3P (PAL))
In Playback
Audio left or right terminal of A/V
Measurement Point
Main unit Audio level meter jack
Audio level meter and frequency
Measuring Instrument
counter
A/V jack Audio (L) 32 kHz mode: 1 kHz, + 3.0 ± 2.0 dBs
48 kHz mode: 1 kHz, + 3.0 ± 2.0 dBs
Audio (R) 44.1 kHz mode:
47 k Ω
47 k Ω: 1-249-437-11 Specified Value The 7.35 kHz signal level during EMP
OFF is +2.0 ± 2.0 dBs.
The 7.35 kHz signal level during EMP
TV monitor ON is −6 ± 2 dB from the signal level
during EMP OFF.
Video

Checking Method:
1) Check that the playback signal level is the specified value.
Fig. 6-3-9

HDR-FX7/FX7E_ADJ
6-99
6-4. SERVICE MODE 2. Precautions Upon Using the Adjustment Remote
Commander (RM-95)
4-1. ADJUSTMENT REMOTE COMMANDER Mishandling of the adjustment remote commander may erase the
(RM-95) correct adjustment data at times. To prevent this, it is recommended
that all adjustment data be noted down before beginning adjust-
The adjustment remote commander (RM-95) is used for changing
ments and new adjustment data after each adjustment.
the calculation coefficient in signal processing, EVR data, etc. The
adjustment remote commander (RM-95) performs bi-directional
communication with the unit using the remote commander signal
line (LANC). The resultant data of this bi-directional communica-
tion is written in the non-volatile memory.

1. Using the Adjustment Remote Commander (RM-95)


1) Connect the adjustment remote commander to the LANC ter-
minal.
2) Set the HOLD switch of the adjustment remote commander
(RM-95) to “HOLD” (SERVICE position). If it has been prop-
erly connected, the LCD on the adjustment remote commander
(RM-95) will display as shown in Fig. 6-4-1.

Page Data Address

Fig. 6-4-1

3) Operate the adjustment remote commander (RM-95) as fol-


lows.
• Changing the page
The page increases when the EDIT SEARCH+ button is
pressed, and decreases when the EDIT SEARCH− button is
pressed. There are altogether 16 pages, from 0 to F.

Hexadecimal
notation 0 1 2 3 4 5 6 7 8 9 A B CD E F
LCD Display 0 1 2 3 4 5 6 7 8 9 A b c d E F
Decimal notation
conversion value 0 1 2 3 4 5 6 7 8 9 1011 12 1314 15

• Changing the address


The address increases when the FF (M) button is pressed,
and decreases when the REW (m) button is pressed. There
are altogether 256 addresses, from 00 to FF.
• Changing the data (Data setting)
The data increases when the PLAY (N) button is pressed,
and decreases when the STOP (x) button is pressed. There
are altogether 256 data, from 00 to FF.
• Writing the adjustment data
The PAUSE button must be pressed to write the adjustment
data in the nonvolatile memory. (The new adjusting data will
not be recorded in the nonvolatile memory if this step is not
performed)
4) After completing all adjustments, turn off the main power sup-
ply (8.4 V) once.

HDR-FX7/FX7E_ADJ
6-100
4-2. ADJUSTMENT REMOTE COMMANDER 2. Precautions Upon Using the Adjustment Remote
(NEW LANC JIG) Commander (New LANC Jig)
The adjustment remote commander (New LANC Jig) is used for Mishandling of the adjustment remote commander (New LANC
changing the calculation coefficient in signal processing, EVR data, Jig) may erase the correct adjustment data at times. To prevent
etc. The adjustment remote commander (New LANC Jig) performs this, it is recommended that all adjustment data be noted down
bi-directional communication with the unit using the remote com- before beginning adjustments and new adjustment data after each
mander signal line (LANC). The resultant data of this bi-direc- adjustment.
tional communication is written in the non-volatile memory.

1. Using the Adjustment Remote Commander


(New LANC Jig))
1) Connect the adjustment remote commander (New LANC Jig)
to the LANC terminal via the LANC cable (J-6082-442-A).
2) Set the slide switch of the adjustment remote commander (New
LANC Jig) to “SERVICE” (SERVICE position). If it has been
properly connected, the LCD on the adjustment remote com-
mander (New LANC Jig) will display as shown in Fig. 6-4-2.

p:00 a:00 d:00


Page Address Data

Fig. 6-4-2

3) Operate the adjustment remote commander (New LANC Jig)


as follows.
• Changing the page
The page increases when the Page+ (M) button is pressed,
and decreases when the Page− (m) button is pressed.
• Changing the address
The address increases when the ADD+ (N) button is
pressed, and decreases when the ADD− (X) button is
pressed. There are altogether 256 addresses, from 00 to FF.
• Changing the data (Data setting)
The data increases when the Data+ button is pressed, and
decreases when the Data− button is pressed. There are alto-
gether 256 data, from 00 to FF.
• Writing the adjustment data
The Write (x) button must be pressed to write the adjust-
ment data in the nonvolatile memory. (The new adjusting
data will not be recorded in the nonvolatile memory if this
step is not performed)
4) After completing all adjustments, turn off the main power sup-
ply (8.4 V) once.

HDR-FX7/FX7E_ADJ
6-101
4-3. DATA PROCESS
The calculation of the DDS display and the adjustment remote
commander display data (hexadecimal notation) are required for
obtaining the adjustment data of some adjustment items. In this
case, after converting the hexadecimal notation to decimal nota-
tion, calculate and convert the result to hexadecimal notation, and
use it as the adjustment data. Indicates the hexadecimal-decimal
conversion table.
Hexadecimal-decimal Conversion Table 2
Lower digit of
hexadecimal 0 1 2 3 4 5 6 7 8 9 A B C D E F
Upper digit ( A) (b) (c) (d) (E) ( F)
of hexadecimal
0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
1 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
2 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47
3 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63
4 64 65 66 67 68 69 70 71 72 73 74 77 76 77 78 79
5 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95
6 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111
7 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127
8 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143
9 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159
A ( A) 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175
1 B (b) 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191
C (c) 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207
D (d) 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223
E (E) 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239
F (F) 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255
Note: The characters shown in the parenthesis ( ) shown the display on the adjustment remote commander.
(Example) If the DDS display or the adjustment remote commander shows BD (bd);
Because the upper digit of the adjustment number is B (b), and the lower digit is D (d), the meeting point
“189” of 1 and 2 in the above table is the corresponding decimal number.

Table 6-4-1

HDR-FX7/FX7E_ADJ
6-102
4-4. SERVICE MODE 2. Emergence Memory Address
2-1. Emergence Memory Address (Mechanism
Note: Before performing the adjustment, check the data of page: section)
0, address: 10 is “00”. If not, select page: 0, address: 00,
and set data “00”. Page C Address F4 to FF

1. Setting the Test Mode Address Contents


F4 EMG code when first error occurs
Page A Address 10
Upper: MSW code when shift starts when first error
F6 occurs
Data Function
Lower: MSW code when first error occurs
00 Normal
Lower: MSW code to be moved when first error
01 Forced camera power ON (CAMERA mode) F7
occurs
02 Forced VTR power ON (VCR mode) F8 EMG code when second error occurs
03 Forced camera + VTR power ON Upper: MSW code when shift starts when second
FA error occurs
• Before setting the data , select page: 0, address: 01, and set data: Lower: MSW code when second error occurs
01.
Lower: MSW code to be moved when second error
• For page A, the data set will be recorded in the non-volatile FB
occurs
memory by pressing the PAUSE (Write) button of the adjust-
ment remote commander. In this case, take note that the test FC EMG code when last error occurs
mode will not be exited even when the main power is turned off Upper: MSW code when shift starts when last error
(8.4 Vdc). FE occurs
• After completing adjustments/repairs, be sure to return the data Lower: MSW code when last error occurs
of this address to 00, and press the PAUSE (Write) button of the
Lower: MSW code to be moved when last error
adjustment remote commander. And select page: 0, address: 01, FF
occurs
and set data: 00.
When no error occurs in this unit, data “00” is written in the above
addresses (F4 to FF). when first error occurs in the unit, the data
corresponding to the error is written in the first emergency ad-
dress (F4 to F7). In the same way, when the second error occurs,
the data corresponding to the error is written in the second emer-
gency address (F8 to FB).
Finally, when the last error occurs, the data corresponding to the
error is written in the last emergency address (FC to FF).
Note: After completing adjustments, be sure to initialize the data
of addresses F4 to FF to “00”.

Initializing method:
Order Page Address Data Procedure
1 0 01 01
2 3 71 01 Press PAUSE (Write) button.
3 3 03 FF
4 3 01 37 Press PAUSE (Write) button.

5 3 02 Check the data changes to


“00”.

6 3 03 Check the data changes to


“00”.
7 3 70 10 Press PAUSE (Write) button.

8 3 70 Check the data changes to


“11”.
9 0 01 01

HDR-FX7/FX7E_ADJ
6-103
Ver. 1.3 2007.09

2-2. EMG Code (Emergency Code)


Codes corresponding to the errors which occur are written in C
page, addresses F4, F8 and FC . The type of error indicated by the
code are shown in the following table.
Code Emergency Type
00 No error
10 Loading motor emergency during loading
11 Loading motor emergency during unloading
22 T reel emergency during normal rotation
23 S reel emergency during normal rotation
T reel emergency (Short circuit between S reel
24
terminal and T reel terminal)
30 FG emergency at the start up of the capstan
40 FG emergency at the start up of the drum
42 FG emergency during normal rotation of the drum

2-3. MSW Code


MSW when errors occur:
Information on MSW (mode SW) when errors occur
MSW when movement starts:
Information on MSW when movements starts when the mechanism position is moved (When the L motor is moved)
MSW of target of movement:
Information on target MSW of movement when the mechanism position is moved

Mechanical Position
← UNLOAD LOAD →
EJ BL ULE BL LD1 (SR) BL LD2 (HL) BL STOP BL R/P
← D (MSB)
0 0 1 0 = 2

0 0 1 1 = 3

0 0 0 1 = 1

0 1 0 1 = 5

0 1 0 0 = 4

0 1 1 0 = 6
0 1 1 1 = 7

0 1 1 1 = 7

0 1 1 1 = 7

0 1 1 1 = 7

0 1 1 1 = 7

←C
←B
← A (LSB)

LS chassis movement section

Lock released Pinch roller pressing


Cassette compartment

Position Code Contents


Position at which the cassette component lock is released, at the farthest unload side mechanically
EJ 2
at which the mechanism can move no further in the UNLOAD direction.
BL 7 BLANK code, at the boundary between codes.
EJECT completion position. when the cassette is ejected, the mechanism will stop at this position.
ULE 3 Cassette IN standby. The guide will start protruding out as the mechanism moves towards the
LOAD position.
When prepraing TOP load processing or when DEW is detected, rolling up tape by T reel is
LD1 (SR) 1
preformed at this position.
When prepraing TOP load processing or when DEW is detected, rolling up tape by S reel is
LD2 (HL) 5
preformed at this position.
Stop position in the loading state. The pinch roller separates, the tension regulator returns, and the
STOP 4
brake is imposed on both reels.
PB, REC, CUE, REVIEW, PAUSE, FF, REW positions. When pinch roller is pressed, and the
R/P 6 tension regulator is ON, the mechanism is operating at this position in modes in which normal
images are shown.
NULL 0 Code not existing in the MD. Default value.
F Status before finding any mechanism position.

HDR-FX7/FX7E_ADJ
6-104
3. Bit Value Discrimination Display on the Bit values
Bit values must be discriminated using the display data of the ad- adjustment bit3 bit2 bit1 bit0
justment remote commander for the following items. Us the table remote or or or or
below to discriminate if the bit value is “1” or “0”. commander bit7 bit6 bit5 bit4
Display on the adjustment remote commander 0 0 0 0 0
1 0 0 0 1
2 0 0 1 0
3 0 0 1 1
4 0 1 0 0
5 0 1 0 1
Address
6 0 1 1 0
Page bit3 to bit0 discrimination
7 0 1 1 1
bit7 to bit4 discrimination A 8 1 0 0 0
9 1 0 0 1
(Example) If the remote commander display is “8E”, bit value from A (A) 1 0 1 0
bit 7 to bit 4 can be discriminated from the column A,
and those from bit 3 to bit 0 from column B. B ( b) 1 0 1 1
C ( C) 1 1 0 0
D (d) 1 1 0 1
B E ( E) 1 1 1 0
F (F ) 1 1 1 1

4. Jack Check (1)

Page 7 Address FF

Bit Function When bit value = 1 When bit value = 0


1 COMPONENT OUT jack (II-003 board CN9204) Used Not used

Using method:
1) Select page: 7, address: FF.
2) By discriminating the bit value of display data, the state of jack can be discriminated.

5. Jack Check (2)

Page 7 Address FB

Bit Function When bit value = 1 When bit value = 0


0 A/V OUT jack (II-003 board CN9203) Used Not used

Using method:
1) Select page: 7, address: FB.
2) By discriminating the bit value of display data, the state of jack can be discriminated.

6. Jack Check (3)

Page 3 Address 61

Bit Function When bit value = 1 When bit value = 0


6 HEADPHONE jack (FP-486 flexible J601) Used Not used

Using method:
1) Select page: 3, address: 61.
2) By discriminating the bit value of display data, the state of jack can be discriminated.

HDR-FX7/FX7E_ADJ
6-105
Ver. 1.1 2007.05

7. Jack Check (4)

Page 3 Address 5B

Bit Function When bit value = 1 When bit value = 0


4 MIC jack (FP-482 flexible J201) Used Not used

Using method:
1) Select page: 7, address: 5B.
2) By discriminating the bit value of display data, the state of jack can be discriminated.

8. Jack Check (5)

Page 7 Address 50

Bit Function When bit value = 1 When bit value = 0


3 MIC jack (FP-482 flexible J201) Stereo Mono

Using method:
1) Select page: 7, address: 50.
2) By discriminating the bit value of display data, the state of jack can be discriminated.

9. Jack Check (6)

Page 3 Address CF

Bit Function When bit value = 1 When bit value = 0


0 HDMI OUT jack (HH-003 board CN7401) Used Not used

Using method:
1) Select page: 3, address: CF.
2) By discriminating the bit value of display data, the state of jack can be discriminated.

10. Switch Check (1)

Page 2 Address 81

Bit Function When bit value = 1 When bit value = 0


0 POWER-VCR (PS18500 block) ON OFF
1 POWER-CAMERA (PS18500 block) ON OFF
3 EJECT (FP-485 flexible S001) ON OFF
4 CC DOWN (Mechanism chassis) ON (DOWN) OFF (UP)
5 DISPLAY/BATT INFO (RR-003 board S9602) ON OFF

Using method:
1) Select page: 2, address: 81.
2) By discriminating the bit value of display data, the state of switch can be discriminated.

HDR-FX7/FX7E_ADJ
6-106
11. Switch Check (2)

Page 7 Address 63 to 6B

Note: Check that the data of page: 0, address: 10 is “00”.

Using method:
1) Select page: 7, address: 63 to 6B.
2) By discriminating the display data, the pressed key can be discriminated.

Data
Address
00 to 0C 0D to 27 32 to 3A 4F to 58 73 to 7B 8B to B7 B8 to E6 E7 to FF

63 ASSIGN ASSIGN ASSIGN PUSH EXPOSURE


(KEY AD7) 1 2 3 AUTO FOCUS IRIS − − No key input
(IC3601 <zcm ) (CK18500 block) (CK18500 block) (CK18500 block) (CK18500 block) (CK18500 block)
(S3001) (S3002) (S3003) (S3004) (S3006)

64 PICTURE STATUS ASSIGN ASSIGN ASSIGN ZEBRA ZEBRA ZEBRA


(KEY AD8) PROFILE CHECK 4 5 6 OFF 100 70
(IC3601 <zc, ) (CF18500 block) (CF18500 block) (RR-003) (RR-003) (RR-003) (RR-003) (RR-003) (RR-003)
(S4005) (S4004) (S9608) (S9610) (S9612) (S9614) (S9614) (S9614)

65 REC
(KEY AD0) START/STOP − − − − − − No key input
(IC3601 <zc. ) (PS18500 block)
(S1001)

66 STOP REW REC PLAY FF SLOW


(KEY AD1) (RR-003) (RR-003) (RR-003) (RR-003) (RR-003) (RR-003) − No key input
(IC3601 <zv/ ) (S9603) (S9606) (S9609, S9611) (S9613) (S9615) (S9616)

PHOTO/ ZOOM ZOOM ZOOM


67 EXPANDED
(KEY AD2) FOCUS − − − − OFF H L
(IC3601 <zvz ) (PL18500 block) (FP-483 flexible) (FP-483 flexible) (FP-483 flexible)
(S2001) (S303) (S303) (S303)

68 REC ZOOM ZOOM


(KEY AD3) START/STOP WIDE TELE − − − − No key input
(IC3601 <zvx ) (FP-483 flexible) (FP-483 flexible) (FP-483 flexible)

69 FOCUS EXPANDED PAUSE PANEL PANEL


(KEY AD4) (CK18500 block) FOCUS (RR-003) − − − REVERSE NORMAL
(IC3601 <zvc ) (S3005) (CK18500 block) (S9604) (FP-487 flexible) (FP-487 flexible)
(S3007) (S701) (S701)

6A SEL/ MENU GAIN SHUTTER WHT BAL AUTO LOCK AUTO LOCK AUTO LOCK
(KEY AD5) PUSH EXEC (CF 18500 block) (CF 18500 block) SPEED (CF 18500 block) HOLD LOCK MANUAL
(IC3601 <zvv ) (CF 18500 block) (S4007) (S4002) (CF 18500 block) (S4006) (CF 18500 block) (CF 18500 block) (CF 18500 block)
(S4008) (S4003) (S4001) (S4001) (S4001)
VOLUME/ VOLUME/ PANEL PANEL
6B MEMORY MEMORY
(KEY AD6) − − − − CLOSE OPEN
+ –
(IC3601 <zvb ) (RR-003) (RR-003) (FP-487 flexible) (FP-487 flexible)
(S9605) (S9607) (S702) (S702)

HDR-FX7/FX7E_ADJ
6-107
12. LED Check

Page 7 Address 00, 01 and 04

Note: Check that the data of page: 0, address: 10 is “00”.

Using method:
Order Page Address Data Procedure

1 Set the unit to CAMERA-


TAPE mode.
2 7 01 90
3 7 04 01
4 7 00 01 Press PAUSE (Write) button.

5 7 02 Check the data changes to


“01”.
Check that the following
LED are lit.
6 • REC LAMP
• CHARGE
• MS ACCESS
7 7 01 90
8 7 04 00
9 7 00 01 Press PAUSE (Write) button.
10 7 00 00
11 7 01 00

12 7 02 Check the data changes to


“01”.

13. Record of Use Check (1)

Page 7 Address A4 to AF

Note 1: This data will not be erased (reset) when the lithium 3 V
power supply (RR-003 board BT9601) is removed.
Note 2: When the drum was replaced, initialize the drum rota-
tion counted time.
Note 3: Check that the data of page: 0, address: 10 is “00”.

Address Function Remarks


A4 Power supplying Hour (H) 100000th place digit and 10000th place digit of counted time (decimal digit)
A5 time Hour (M) 1000th place digit and 100th place digit of counted time (decimal digit)
A6 Hour (L) 10th place digit and 1st place digit of counted time (decimal digit)
A7 (BCD code) Minute
A8 Drum rotation Hour (H) 100000th place digit and 10000th place digit of counted time (decimal digit)
A9 counted time Hour (M) 1000th place digit and 100th place digit of counted time (decimal digit)
AA Hour (L) 10th place digit and 1st place digit of counted time (decimal digit)
AB (BCD code) Minute
AC Tape run time Hour (H) 100000th place digit and 10000th place digit of counted time (decimal digit)
AD Hour (M) 1000th place digit and 100th place digit of counted time (decimal digit)
AE Hour (L) 10th place digit and 1st place digit of counted time (decimal digit)
AF (BCD code) Minute

Using method:
1) The record of use data is displayed at page: 7, addresses: A4 to
AF.

HDR-FX7/FX7E_ADJ
6-108
Initializing method:
Order Page Address Data Procedure
1 7 A4 00 Press PAUSE (Write) button.
2 7 A5 00 Press PAUSE (Write) button.
3 7 A6 00 Press PAUSE (Write) button.
4 7 A7 00 Press PAUSE (Write) button.
5 7 A8 00 Press PAUSE (Write) button.
6 7 A9 00 Press PAUSE (Write) button.
7 7 AA 00 Press PAUSE (Write) button.
8 7 AB 00 Press PAUSE (Write) button.
9 7 AC 00 Press PAUSE (Write) button.
10 7 AD 00 Press PAUSE (Write) button.
11 7 AE 00 Press PAUSE (Write) button.
12 7 AF 00 Press PAUSE (Write) button.

14. Record of Use Check (2)

Page 7 Address 90 to 95

Note 1: This data will not be erased (reset) when the lithium 3 V
power supply (RR-003 board BT9601) is removed.
Note 2: When the drum was replaced, initialize the drum rota-
tion counted time.
Note 3: Check that the data of page: 0, address: 10 is “00”.

Address Function Remarks


90 Eject count with tape Count (H) 100000th place digit and 10000th place digit of Eject count (decimal digit)
91 Count (M) 1000th place digit and 100th place digit of Eject count (decimal digit)
92 (BCD code) Count (L) 10th place digit and 1st place digit of Eject count (decimal digit)
93 Eject count without Count (H) 100000th place digit and 10000th place digit of Eject count (decimal digit)
94 tape Count (M) 1000th place digit and 100th place digit of Eject count (decimal digit)
95 (BCD code) Count (L) 10th place digit and 1st place digit of Eject count (decimal digit)

Using method:
1) The record of use data is displayed at page: 7, addresses: 90 to
95.

Initializing method:
Order Page Address Data Procedure
1 7 90 00 Press PAUSE (Write) button.
2 7 91 00 Press PAUSE (Write) button.
3 7 92 00 Press PAUSE (Write) button.
4 7 93 00 Press PAUSE (Write) button.
5 7 94 00 Press PAUSE (Write) button.
6 7 95 00 Press PAUSE (Write) button.

HDR-FX7/FX7E_ADJ
6-109
Ver. 1.1 2007.05

15. Record of Use Check (3)

Page 7 Address C8 to CD

Note 1: This data will not be erased (reset) when the lithium 3 V
power supply (RR-003 board BT9601) is removed.
Note 2: Check that the data of page: 0, address 10 is “00”.

Address Function Remarks


C8 User initial power Year
C9 on date Month After setting the clock, set the date of power on next
CA (BCD code) Day
CB Final condensation Year
CC occurrence date Month
CD (BCD code) Day

Using method:
1) The record of use data is displayed at page: 7, addresses: C8 to
CD.

16. Record of Self-diagnosis Check

Page 7 Address B0 to C6 Initializing method:


Order Page Address Data Procedure
Note 1: This data will not be erased (reset) when the lithium 3 V
1 7 01 C0
power supply (RR-003 board BT9601) is removed.
Note 2: Check that the data of page: 0, address 10 is “00”. 2 7 00 01 Press PAUSE button.
3 7 B0 to C6 Check that the data is “00”.
Address Self-diagnosis code
4 7 00 00
B0 “Repaired by” code (Occurred 1st time) *1
5 7 01 00
B1 “Block function” code (Occurred 1st time)
B2 “Detailed” code (Occurred 1st time)
B4 “Repaired by” code (Occurred 2nd time) *1
B5 “Block function” code (Occurred 2nd time)
B6 “Detailed” code (Occurred 2nd time)
B8 “Repaired by” code (Occurred 3rd time) *1
B9 “Block function” code (Occurred 3rd time)
BA “Detailed” code (Occurred 3rd time)
BC “Repaired by” code (Occurred 4th time) *1
BD “Block function” code (Occurred 4th time)
BE “Detailed” code (Occurred 4th time)
C0 “Repaired by” code (Occurred 5th time) *1
C1 “Block function” code (Occurred 5th time)
C2 “Detailed” code (Occurred 5th time)
C4 “Repaired by” code (Occurred the last time) *1
C5 “Block function” code (Occurred the last time)
C6 “Detailed” code (Occurred the last time)
*1 : “01” t “C”, “03” t “E”

Using method:
1) The past self-diagnosis codes are displayed at page: 7, address:
BC to C6. Refer to “1-5. SELF-DIAGNOSIS FUNCTION” of
“SERVICE MANUAL, LEVEL 2” for detail of the self-diag-
nosis code.

HDR-FX7/FX7E_ADJ
6-110
FOR CAMERA COLOR REPRODUCTION ADJUSTMENT

Take a copy of CAMERA COLOR


REPRODUCTION FRAME with a
clear sheet for use.
For Indoor HD mode (NTSC model)

R-Y

R MG

YE
B-Y
B

G
CY

✄ HDR-FX7

For Indoor SD mode (NTSC model)

R-Y

R MG

YE
B-Y

G
CY

HDR-FX7
HDR-FX7/FX7E_ADJ
6-111
FOR CAMERA COLOR REPRODUCTION ADJUSTMENT

Take a copy of CAMERA COLOR


REPRODUCTION FRAME with a
clear sheet for use.
For Outdoor HD mode (NTSC model)

R-Y

R MG

YE

B-Y
B

G
CY

✄ HDR-FX7

For Outdoor SD mode (NTSC model)

R-Y

R MG

YE
B-Y

G CY

HDR-FX7
HDR-FX7/FX7E_ADJ
6-112
FOR CAMERA COLOR REPRODUCTION ADJUSTMENT

Take a copy of CAMERA COLOR


REPRODUCTION FRAME with a
clear sheet for use.
For Indoor HD mode (PAL model)

R-Y

R MG

YE
B-Y
B

G
CY

✄ HDR-FX7E

For Indoor SD mode (PAL model)

R-Y

R MG

YE
B-Y

G
CY

HDR-FX7E
HDR-FX7/FX7E_ADJ
6-113
FOR CAMERA COLOR REPRODUCTION ADJUSTMENT

Take a copy of CAMERA COLOR


REPRODUCTION FRAME with a
clear sheet for use.
For Outdoor HD mode (PAL model)

R-Y

R MG

YE

B-Y
B

G
CY

✄ HDR-FX7E

For Outdoor SD mode (PAL model)

R-Y

R MG

YE

B-Y

G CY

HDR-FX7E
HDR-FX7/FX7E_ADJ
6-114E
6-114
Reverse 985215455.pdf

Revision History

S.M. Rev.
Ver. Date History Contents
issued
1.0 2006.10 Official Release — —
1.1 2007.05 Revised-1 • Correction of PSD Sensor Gradient Yes
Adjustment
• Change of Differential Gain Adjustment
• Correction of Color Reproduction
Adjustment
• Correction of MAX GAIN Adjustment
• Correction of Auto White Balance Check
• Correction of Color Reproduction Check
• Correction of Switch Check
• Correction of Record of Use Check
S.M. correction: Page 6-32, Page 6-34,
Page 6-54, Page 6-62,
Page 6-63, Page 6-64,
Page 6-67, Page 6-70,
Page 6-75, Page 6-106,
Page 6-110
1.2 2007.06 Supplement-1 • Change of D, 1A, C, 13, 18, 8D, 7E Page table No
(S1 DI07-026) • Addition of “How to read the sensitivity
data of angular velocity sensor”
1.3 2007.09 Revised-2 Replace the previously issued SERVICE Yes
(A2 DI07-103) MANUAL 9-852-154-52 with this Manual.
• Correction of the MSW Code
S.M. revised: Page 6-104
1.4 2008.06 Revised-3 Replace the previously issued SERVICE Yes
(A3 DI08-172) MANUAL 9-852-154-53 with this Manual.
• Change of D, 1A, C, 13, 18, 8D, 7E Page table
• Change of F No. & ND Light Quality
Standard Data Input
• Addition of “How to read the sensitivity
data of angular velocity sensor”
S.M. revised: Page 2, Page 6-8, Page 6-11,
Page 6-12, Page 6-21,
Page 6-22, Page 6-31,
Page 6-47, Page 6-58,
Page 6-60
Replace the SUPPLEMENT-1 with the
REVISED-3.
Please discard the SUPPLEMENT-1.

HDR-FX7/FX7E_ADJ