RUDDER TRAILING EDGE. ASSISTED IN CARRYING OUT STATIC DISCHARGER ROD AND BASE REPLACEMENT DURING C CHECK. TASK CARRIED OUT ACCORDANCE WITH AMM AND SECURITY OF INSTALLATION FOUND SATISFACTORY REF : 23-61-00 PG 401 (22-1-2019) JN: DR00039 (HASSAN)
FOUND FUEL LEAK ON ENGINE NO 1
FUEL SHUT OFF VALVE DURING REFUELLING. TROUBLESHOOT CARRIED OUT FOUND PORT ADAPTER ASSEMBLY MOUNTING BOLTS LOOSEN. CARRIED OUT MOUNTING BOLT RETIGHTEN AS PER AMM 28-22-11 PG 409. FUEL LEAK TEST FOUND SATISFACTORY JN:DR00101 (1/2/2019) ATR 72 9M – LMH… REV 19 18 DEC 2018 FOUND RH LANDING LIGHT NOT ILLUMINATED TROUBLESHOOT CARRIED OUT FOUND LAMP LIGHT UNSERVICEABLE LANDING LIGHT LAMP REPLACEMENT CARRIED OUT AS PER JIC 33-20-00 OPT 10000 DURING C CHECK. OPERATIONAL TEST CARRIED OUT AND FOUND SATISFACTORY ( 7/1/2019) JN:DR00027 (HASSAN)
FOUND AFT CARGO LIGHT NOT ILLUMINATED
TROUBLESHOOT CARRIED OUT FOUND LAMP LIGHT UNSERVICEABLE AFT CARGO LIGHT LAMP REPLACEMENT CARRIED OUT AS PER JIC 33-20-00 OPT 10000 DURING C CHECK. OPERATIONAL TEST CARRIED OUT AND FOUND SATISFACTORY REV : AMM 33-20-00 OPT 10000 (7/1/2019) JN: DR00028