SITE ACCEPTANCE TEST REPORTS VOLUME NO: 1 FILE NO: 1.1 13. C10 VT TEST REPORT ELSEWEDY Test Report for ELECTRIC | Voltage Transformer Of PSP oar cin Project Name System: 132kV GIS |AL WUKAIR 11 SUBSTATION 132/11KV. ‘Author / Prepared P&C TRAM Lang, REV. NO. Page/No.of pages DWG NO. AWKI1-ESC-11-12-R004 En A Page | of 3 132 KV GIS Voltage transformer test report Objective: - this tests are performed on the VT's to determine it’s (ratio error % , polarity , and winding resistance ) then compare it with reference values , and see if the error is within range or not. Test procedure: ~ perform insulation resistance test on VT primary and secondary windings and record the results. -using omicron CPC 100 perform the test for turns ratio by applying 2 KV AC on the VT primary winding and measure the secondary voltage then calculate the ratio error. -using omicron CPC 100 perform the test for winding resistance by injecting current to the secondary winding terminal and measure the voltage across the secondary winding and calculate the resistance. Equipment name | manufacturer S/N Cal. date Due to Insulation Megger 70/121212/4304| 1/3/2017 28/2/2018 resistance tester ‘CPC 100 Omicron LUS73T 2/5/2017 2/5/2018 Note: ‘+ Applicable standard IEC 61869-3, + Test shall be satisfied with approved specs and drawing. EL SEWEDY ELECTRIC PSP EPE/KAHRAMAA Name Mr. Mohamed abdullah Mr. Hariprasad.M Signature Sa Cage Date 29/6 | 2017 29 /6 / 2017 ELSEWEDY Test Report for vars Piss ELECTRIC | Voltage Transformer Of septs —_— e aca PSP BAY C10 Project Name System 13kV GIS [AL WUKAIR 11 SUBSTATION 132/11KV ‘Author / Prepared P&C TEAM Lang, — | REV. NO. Page/No.of pages DWG NO. AWKII-ESC-11-12-R004 En A Page 2 of 3 CIRCUIT: CABLE FEEDER: C10 ‘Amb. Temp: 32°C 1. PT NAME PLATE DETAILS: Make TAKAOKA YOKO CO.,LTD Serial No/Year D706521A/2017 Ratio 132000/N3 / 110/N3 / 110/V3/ 110/V3 Class 1+3P - 1+3P - 14+3P. Burden(VA) 100 — 100 - 100 2. PT INSULATION RESISTANCE: (All Values in GQ) Applied Ref. Voltage RPH YPH BPH | Primary-Earth | 5000V 326 187 382 | Pri—Core 1 268 193 722 [—Pi=Corez | 1000¥ 191 27.8 448 Core 1 - Earth 96.9 7 143 Core 2 - Earth 500 V 100 135 206 Core -Core 2 106 117 34.5 3. PT WINDING RESISTANCE: Winding resistance (mQ) Circuit Reference R-PH Y-PH B-PH 32°C 75°C 32°C 75°C 32°C 75°C Core 1 58.551 67.981 55.832 64.824 55.24 64.137 Core 2 54.463 63.235, 52.352 60.784 53.363 61.957 EL SEWEDY ELECTRIC PSP. EPE/KAHRAMAA Kame Mr. Mohamed abdullah Mr, Hariprasad. M Signature FG WWhopy ogo? Date 29/6 / 2017 29 /6 / 2017 elSeweoy ‘Test Report for wim Ff ELECTRIC | Voltage Transformer Of soe | ER SP BAY C10 = Project Name System 132k GIS [AL WUKAIR 11 SUBSTATION 132/11KV Author / Prepared Tac TEAM tang. [REVNO- | page/No.of pages DWG NO, AWEKII-ESC-11-12-R004 Ea A Page 3 of 3 4, PT POLARITY CHECKED: OK 6. PT RATIO: 132000/V3 / 110/13 Volts Circuit ret | Applied voltage (Volts) Measured voltage (Volts) Ratio error % R 1999.26 4.6703 0.26 Core 1] Y 1999.65, 1.6707 0.26 B 1999.47 1.6707 0.27 R 1999.49 1.6704 0.25 Core 2) y 1999.62 1.6706 0.25 8 1999.53 1.6708 0.26 EL SEWEDY ELECTRIC PSP EPE/KAHRAMAA Name Mr. Mohamed abdullah Mr. Hariprasad. M Signature Sa Geen? Date 29 /6 / 2017 29 (6 / 2017 \ALWAKAIR 132-11\C10-RATIO-D706521A.xml: ‘Test Device: CPC 100 Serial Number: LJS73T (V1) Date/Time: (06/29/2017 14:06:14 Overall assessment: n/a Test Cards Overview: [Test Card [type [Date/Time [ResuitsAssessment] Overload] IRPH-CORE! |VrRatio][06/29/2017 14:00:48]lyes _|fnva [no IRPH-CORE2||VTRatio]|06/29/2017 14:01:26]lyes —_|fvva fro [yeH.CorE! |v rRatiollos/29/2017 14 es__|va no [YPH-CORE2|VTRatiol[06/29/2017 14:03:28]|yes __|[n/a [no [BPH-COREI||VTRatio](06/29/2017 14:04:09] yes__ va hno [bPH-CoRE2]|vTRatiol(o6/29/2017 14:04:45]yes [va lho Test Cards: RPH-COREL: Card Type: VTRatio Date/Time: 06/29/2017 14:00:48 Overload: no Assessment: n/a Range: AC2KV Nominal values: V prim. 132000/V3 V V see. 110.0/V3 V 50.00 Hz, 2000.0.V yes 1999.26 V 0.00° 1.6703 V 0.00 132000/V3 V:110.2826/V3 V 0.26 % Polarity: OK Mohaned Abdulla NA i Making as ao Af RPH-CORE2: Card Type: VTRatio Date/Time: 06/29/2017 14:01:26 Overload: no Assessment: n/a Range: AC 2kV Nominal values: Vprim.: 1320003 V Vises: 110.093 V Frequeney: 50.00 Hz Viest: 2000.0 V Automatic: yes Results: 1999.49 V 0.00° 1.6704 V 0.00° 132000/V3 V:110.274913 V 0.25 % OK YPH-CORBI: Card Type: VTRatio Date/Time: 06/29/2017 14:02:00 Overload: no Assessment: n/a Ran, AC 2kV Nominal valnes: V prim.: 132000/V3 V Vsec.: 110.03 V Frequency: 50.00 Hz Viest: 2000.0 V Automatic: yes Results: V prim. 1999.65 V 0.00° V sees: 1.6707 V 0.00 Ratio: 132000/V3 V:110.2855/N3 V 0.26 % Polarity: OK YPH-CORE2: Card Type: VTRatio Date/Time: 06/29/2017 14:03: Overload: no Assessment: n/a Range: AC 2kV Nominal values: V prim: 13200013 V Vssee.: 110.0/V3 V Frequency: 50.00 Hz Viest: 2000.0V Automat yes Results: V prim.: 1999.62. V 0.00° Vseez 1.6706 V 0.01 Ratio: 132000/V3 V:110.2789/V3 V 0.25 % Polarity: OK BPH-COREL Card Type: VTRatio Date/Time: 06/29/2017 14:04:09 Overload: no Assessment: n/a AC 2kV Nominal values: 132000/V3 V 110.03 V Frequeney: 50.00 Hz Vest: 2000.0 V Automatic: yes Results: 1999.47 V 0.00° 1.6707 V 001° 132000/V3 V:110.2951/V3 V 0.27% OK M.A BPH-CORE2: Card Type: VTRatio Date/Time: 06/29/2017 14:04:45 Overload: no Assessment: n/a Range: AC 2kV Nominal values: Vprim.: 132000/V3 V Vsseci: 110.03 V Frequency: 50.00 Hz Viest: 2000.0 Automat yes Results: V prim.: 1999.53 V 0.00° Vsec: 1.6706 V 0.03 ° Ratio: 132000/V3 V:110.2875/V3 V 0.26 % Polarity: OK M.A \ALWAKAIR 132-11\C10-RESISTANCE-D706521A.xml: fest Device: PC 100 Serial Number: L1S73T (V1) Date/Time: 06/29/2017 13:54:42 Overall assessment: n/a Test Cards Overvi [testCard_|[type _|[DaterTime |Results||Assessment|Overload| [RPH-COREI |RWindingl|06/29/2017 13:42:53]lyes [fa Ino. IRPH-CORE2|[Winding]|06/29/2017 13:44:25] yes [n/a hho [YPH-CORE1|RWinding|06/29/2017 13:45:58|]yes ava Ino. YPH-CORE2|[RWindingl|06/29/2017 13:47:36]yes __|fuia Ino [BPH-CORE1 |RWinding]06/29/2017 13:50:27])yes n/a 0 [BPH-CORE2}RWinding|06/29/2017 13:52:24]lyes _|fuia fno Test Cards: RPH-COR Card Typ. Date/Time: 06/29/2017 13:42:53 Overload: no Assessment: n/a DC 6A 1,000. 200.00 2 10.0002 869.07 mA 50.885 mV 58.551 mQ 0.07% Tim 22.000 s ‘Temperature compensation for copper: 32.00 °C 75.00 °C Rref: 67.981 mQ RPH-CORE2: Card Type: RWinding Date/Time: 06/29/2017 13:44:25 Overload: no Assessment: n/a DC6A 1,000 A 200.00 ps2 10.000 869.28 mA 47.344 mV 54.463 ma Deviation: 0.02% Time: 26.000 s ‘Temperature compensation for copper: T meas.: 32,00 °C. T refs 75.00 °C. R refs 63.235 ma YPH-COREI: Card Type: Date/Time: 06/29/2017 13: Overload: no Assessment: n/a Range: DC 6A I test: 1.000 A 200.00 pO 10.000. 869.92 mA 48.570 mV 55,832 ma 0.02 % 38.000s AA ‘Temperature compensation for copper: Tmeas.: 32.00 °C. ‘Tref: 75.00 °C Rref: 64,824 mQ YPH-CORE2: Card Type: RWinding Date/Time: 06/29/2017 13:47:36 Overload: no Assessment: n/a Range: DC6A Ttest: 1.000 A Rimi 200.00 po Rima: 10.000 2 Results: IDC: 877.59 mA voc: 45.944 mV R meas. 52.352 m2 Deviation: 0.03 % Time: 48.000 s Temperature compensation for copper: T meas.: 32.00 °C T ref: 75.00 °C Reet: 60.784 m2 BPI-CORE Card Type: RWinding Date/Time: 06/29/2017 13:50:27 Overload: no Assessment: n/a DC 6A 1.000. 200.00 12 10,000 2 871.01 mA 48.115 mV M.A Rmeas.: 55.240 mQ Deviation: 0.06 % ‘Time: 87.000 s ‘Temperature compensation for copper: ‘Tmeas.: 32.00 °C Tref 75.00 °C Rref 64.137 ma BPH-CORE2: Card Type: RWinding Date/Time: 06/29/2017 13:52:24 Overload: no Assessment: n/a Range: DC6A test: 1.000. R min. 200.00 2 Rmax: 10.000. Results: 1pe: 871.04 mA voc: 46.482 mV R meas, 53.363 mo Deviation: 0.02% Time: 44.000 s ‘Temperature compensation for copper: T meas. 32.00°C T ref. 75.00°C R ref: 61.957 mQ S.A SITE ACCEPTANCE TEST REPORTS VOLUME NO: 1 FILE NO: 1.1 14. C20 VT TEST REPORT ELSEWEDY Test Report for ME ELECTRIC | Voltage Transformer Of ‘Sees PSP BAY C20 s Project Name System 132kV GIS AL WUKAIR 11 SUBSTATION 132/11KV ‘Author / Prepared P&C TEAM tang. — [REV-NO. T page/No.of pages DWG NO. AWKII-ESC-11-12-R004 En A Page | of 3 132 KV GIS Voltage transfor t report Objective: - this tests are performed on the VT's to determine it's (ratio error % , polarity , and winding resistance ) then compare it with reference values , and see if the error is within range or not. Test procedure: - perform insulation resistance test on VT primary and secondary windings and record the results, -using omicron CPC 100 perform the test for turns ratio by applying 2 KV AC on the VT primary winding and measure the secondary voltage then calculate the ratio error. -using omicron CPC 100 perform the test for winding resistance by injecting current to the secondary winding terminal and measure the voltage across the secondary winding and calculate the resistance Reference DWG: AWK I1-ESC-11-12-R004 Equipment name | manufacturer S/N Cal. date Due to Insulation Megger 70/121212/4304 1/3/2017 28/2/2018 resistance tester [ert Omicron LIS73T 2/8/2017 2/5/2018 Note: + Applicable standard IEC 61869-3. + Test shall be satisfied with approved specs and drawing EL SEWEDY ELECTRIC PSP EPE/KAHRAMAA Name Mr. Mohamed abdullah Mr. Hariprasad. M soe Sa enna Date 1/7 / 2017 1/7/2017 €LSEWEDY Test Report for ELECTRIC | Voltage Transformer Of Sper BAY C20 = min ff @ orm eres Project Name System 182KV GIS [AL WUKAIR 11 SUBSTATION 132/11KV Author / Prepared T&C TEAM Lang. [RPV-NO. | page/No.of pages DWG NO, AWKII-ESC-11-12-R004 En A Page 2 of 3 CIRCUIT: CABLE FEEDER: C20 4. PT NAME PLATE DETAILS: ‘Amb, Temp: 32°C Make TAKAOKA YOKO CO.,LTD Serial No./Year D706522A/2017 Ratio 132000/V3 / 110/Y3 / 110N3/ 110/V3 Class 493P = 143P - 143P Burden(VA) 4100 ~ 100 - 100 | 2. PT INSULATION RESISTANCE: (All Values in GQ) Ref. whee RPH YPH BPH Piimary-Eath_| 5000 117 191 744 Pri —Core 1 212 160 401 Pi-Core2 | OY 251 119 628 Core 1 - Earth 120 122 93 Core2-Earth | 500V 129 94.4 133, Coret -Core 2 171 89.5 128 3. PT WINDING RESISTANCI Winding resistance (ma) “| Circuit Reference RPH Y-PH BPH sec | 75°C sec | 76c sec | 75°C Secondary Core 1 55.138 | 64018 | 56.020 | 6388 | 54.757 | 63.575 Secondary Core 2 53.044 | 62631 | 52.335 | 60.763 | 53.805 | 62.471 EL SEWEDY ELECTRIC PSP EPE/KAHRAMAA Name Mr, Mohamed abdullah Mr. Heaviprasad.M4 Signature Sez ae. Date 1/7/2017 1/7 / 2017 eacweny Test Report for wun If Voltage Transformer Of Snopes ee PSP BAY C20 Projeet Name ra Satan TaaKv Gis AL WOKAIR 11 SUBSTATION 133/11KV ‘Author / Prepared ‘TAC TEAM, Lang, REY; NO. Page/No.of pages: DWG NO. AWKI1-ESC-11-12-R004 En A Page 3 of 3 4, PT POLARITY CHECKED: OK 5. PT RATIO: 132000/\3 / 110/V3 Volts Circuit ref | Applied voltage (Volts) Measured voltage (Volts) Ratio error % R 1999.5 1.6707 0.27 Core 1 ly 1999.56 1.6707 0.27 B 1999.57 1.6708 0.27 R 1999.59 4.6707 0.28 Core 2) y 1999.34 1.6704 “028 B 1999.48 1.6706 0.26 EL SEWEDY ELECTRIC PSP EPE/KAHRAMAA Name Mr, Mohamed abdullah Mr, Hariprasad. M Signature Carr gu 4ee— Date 1/7 / 2017 1/7 | 2017 \ALWAKAIR 132-11\C20-RATIO-D70652 ‘Test Device: CPC 100 Serial Number: LJS73T (V1) Date/Time: 07/01/2017 10:09:34 Overall assessment: n/a Test Cards Overview: 2A.xml: [Rest Card _|[Type _||Date/Time Resuits [Assessment](Overload [RPH-CORE 1]|VTRatio}/07/01/2017 10:05:02|lyes inva {no [RPH-CORE 2]|VTRatio}|07/01/2017 10:05:23}lyes [n/a ino [YPH-CORE] |[VTRatio]|07/0 1/2017 10:06:08}lyes \n/a [no LYPH-CORE2 |VrRatiol(07/01/2017 10:06:4iyes lua lno [BPH-CORE1 ]|VTRatio}}07/01/2017 10:07:33}lyes [n/a [no [per-corr2 [VTRatio}07/01/2017 10:07:S7}yes ina. no, Test Cards: RPH-CORE 1 Card Type: VTRatio Date/Time: 07/01/2017 Overload: no Assessment: n/a Range: AC 2kV Nominal values: V prim. 132000/V3 V V sec: 110.013 V Frequency: 50.00 Hz V test: 2000.0 V Automatic: yes Results: V prim.: 1999.50 V 0.00° V see. 1.6707 180.00 ° Ratio: 132000/V3 V:110.2918/N3 V 0.27 % Polarity: Failed RPH-CORE 2: Card Type: VTRatio Date/Time: 07/01/2017 10:05:23 Overload: no Assessment: n/a Range: AC 2kV Nominal valu ‘V prim.: 132000/¥3 V Vssec.: 110.013 V Frequency: 50.00 Hz Vitest: 2000.0 V Automatic: yes Results: V prim.: 1999.59. V 0.00° Vsec. 1.6707 V 179.99° Ratio: 132000/V3 V:110.2855/V3 V 0.26% Polari Failed YPu-col Card Type: VTRatio Date/Time: 07/01/2017 10:06:08 Overload: no Assessme Range: AC 2kv Nominal values: V prim: 1320003 V Vsecs 110.03 V Frequency: 50.00 Hz V test: 2000.0 V Automatic: yes 1999.56 V 0.00° 1.6707 V -179.99° 132000/V3 V:110.2924/\3 V 0.27% Failed A A sur YPH-CORE2: Card Type: VTRatio Date/Time: 07/01/2017 10:06:41 Overload: no Assessment: n/a Range: AC 2kV ‘Nominal values: 132000113 V 110.03 V Frequeney: 50.00 Hz Viest: 2000.0V Automatic: yes Results: V prim: 1999.34 V 0.00° Vsec. 1.6704 V -180.00° 132000/V3 V:110.2848/V3 V 0.26 % Failed BPH-COREL: Card Type: VIRatio Date/Time: 07/01/2017 10:07:33 Overload: no Assessment n/a Range: AC2KV Nominal values: V prim.: 132000/N3 V V see: 110.03 V Frequeney: 50,00 Hz Veest: 2000.0V Automatic: yes 1999.57 V 0.00° 1.6708 V -180,00° 132000/V3 V:110.2972/¥3 V 0.27% Failed BPH-cORE2: Card Type: VTRatio Date/Time: 07/01/2017 10:07:57 Overload: Assessment: n/a Range: ‘Nominal values: V prim.: Vsec: Frequency: Vest: Automatic: Results; V prim.: Vsec.: Ratio: Polarity: AC 2kV 132000/V3 V 110.03 V 50.00 Hz 2000.0 V yes 1999.48 V 0.00° 1.6706 V 179.99° 132000/V3 V:110.2899/N3 V 0,26 % Failed \ALWAKAIR 132-11\C20-RE! ISTANCE-D706522A.xml: ‘Test Device: CPC 100 Serial Number: LJS73T (V1) Date/Time: 07/01/2017 10:03:16 Overall assessment: n/a ‘Test Cards Overvier [TestCard_|Type _|[Date/Time [Results}Assessment| Overload] IRPH-CORE! |RWinding|07/01/2017 09:52:35]yes va Ino IRPH-CORE2|RWinding}07/01/2017 09:53:59]fyes__[Inva lho [YPH-CORE!|RWinding]07/01/2017 09:56:45]|yes __|fve Ino. [YPH-CORE2|[RWinding[07/01/2017 09:58:22]lyes_|nva no. IBPH-COREI|RWinding}07/01/2017 10:00:13]fyes _|Iva lho BPH-CORE2}RWinding]07/01/2017 10:01:49|yes | na lno ‘Test Cards: RPIL-CORE!: Card Type: RWinding Date/Time: 07/01/2017 09:52:35 Overload: no Assessment: na Range: DC 6A Ttest: 1.0004 R mins 200.00 wd Rmax: 10.000 @ Results: 880.64 mA, 48.557 mV 55.138 m2 0.02% 36.000 s ‘Temperature compensation for copper: T meas. 32.00°C T refs 75.00°C Rref: 64.018 mQ RPH-CORE2: Card Type: RWinding Date/Time: 07/01/2017 09:53:59 Overload: no Assessment: n/a Range: DC6A Ttest: 1.000 A 200.00 se 10.000 2 re: 890.81 mA voc: 48.054 mV R meas.: 53.944 mQ Deviation: 0.03 % Time: 58.0005 ‘Temperature compensation for copper: T meas.: 32.00°C T ref 75.00°C R ref 62.631 mQ YPH-COREI: Card Type: RWinding Date/Time: 07/01/2017 09:56:45 Overload: no Assessment: n/a Range: DC 6A test: 1,000.4 R min.: 200.00 22 R max: 10,000 2 Results: pe: 875.99 mA voc: 48.197 mV R meas. 55.020 m2 Deviation: 0.03% Tim 44,000 MA ‘Temperature compensation for copper: ‘Tmeas.: 32.00°C T ret: 75.00 °C Rref: 63.880 mQ YPH-CORE2: Card Type: RWinding Date/Time: 07/01/2017 09:58:22 Overload: no Assessment: n/a Range: DC6A Ttest: 1,000 A Rimi 200.00 2 Rimax.: 10.0000 Results: Ipc: 875.05 mA voc: 45.796 mV R meas: 52.335 m2 De : 0.04% Time: 47.000 s ‘Temperature compensation for copper: T meas. 32.00°C T ref, 75.00 °C R refs 60.763 mo BPH-COREI: Card Type: RWinding Date/Time: 07/01/2017 10:00:13, Overload: no Assessment: n/a DC 6A 1.000 A R min: 200.00 pa R max: 10.000 2 Results: 1pe: 886.25 mA voc: 48.528 mV 54.757 mQ 0.03% 61.000 s ‘Temperature compensation for copper: Tmeas.: 32.00 °C Tre 75.00°C Rref: 63.575 mo BPH-CORE2: Card Type: RWinding Date/Time: 07/01/2017 10:01:49 Overload: no Assessment: n/a Range: DC 6A Test: 1.000 A R min.: 200.00 po R max; 10.000. Results: pe: 891.16 ma, voc: 47.949 mV R meas.: 53.805 ma Deviation: 0.01% Time: 49.000 s ‘Temperature compensation for copper: T meas.: 32.00°C T ref. 75.00°C R refs 62.471 mQ MA SITE ACCEPTANCE TEST REPORTS VOLUME NO: 1 FILE NO: 1.1 15. C30 VT TEST REPORT ELSEWEDY ELECTRIC ‘Test Report for Voltage Transformer Of wwe Fn a — Project Name System’ 132K GIS [AL WUKAIR 11 SUBSTATION 132/11KV ‘Author / Prepared T&C TEAM bang, |RPYNO- | Page/wo.of pages DWG NO, AWKII-ESC-11-12-R004 En A Page | of 3 132 KV GIS Voltage transformer test re} Objective: ~ this tests are performed on the VT’s to determine it's (ratio error % , polarity , and winding resistance ) then compare it with reference values , and see if the error is within range or not. Test procedure: ~ perform insulation resistance test on VT primary and secondary windings and record the results, using omicron CPC 100 perform the test for turns ratio by applying 2 KV AC on the VT primary winding and measure the secondary voltage then calculate the ratio error. -using omicron CPC 100 perform the test for winding resistance by injecting current to the secondary winding terminal and measure the voltage across the secondary winding and caloulate the resistance. Reference DWG: AWK11-ESC-11-12-R004 Equipment name [manufacturer S/N Cal. date Due to ~Tnsulation Megger | 70/121212/4304 1/3/2017 28/2/2018 resistance tester 7 CPC 100 Omicron LIS73T 2/5/2017 2/5/2018 Note: + Applicable standard IEC 61869-3 + Test shall be satisfied with approved specs and drawing, EL SEWEDY ELECTRIC PSP EPE/KAHRAMAA Name ‘Mr. Mohamed abdullah Mr. Hariprasad.M Signature Wa Date 29/6 [ 2017 29 [6 | 2017 ELSEWEDY Test Report for voice Pur ELECTRIC | Voltage Transformer Of snort sent PSP BAviCe®, Project Name System 19kV GIS [AL WUKAIR 11 SUBSTATION 182/11KV — REV. NO, ‘Author / Prepared Tac TEAM Lang. Page/ No.of pages DWG NO. AWKII-ESC-11-12-R004 Ea a Page 2 of 3 CIRCUIT: CABLE FEEDER: C30 Amb. Temp: 32°C 1. PT NAME PLATE DETAILS: Make TAKAOKA YOKO CO.,LTD Serial No./Year D706523A/2017 Ratio 132000/V3 / 140/V3 / 110/¥3/ 110/V3 Class 143P - 143 - 143P Burden(VA) 100-100 - 100 2. PT INSULATION RESISTANCE: (All Values in GQ) Applied Ref. Voliage RPH YPH BPH Primary-Earth | 5000 V 157 133 204 Pi-Coret | soggy 121 885 84.6 Pri-Core2 89.3 27.9 113 Core 1 - Earth 141 83.9 130 Core2-Earth | 500V 88.6 886 146 Coret -Core 2 216 56.2 65.3 3. PT WINDING RESISTANCE: Winding resistance (ma) Circuit Reference RPH Y-PH B-PH 32°C 75°C sec | 7c 32°C 75°C Secondary Core 1 55.633 | 64.592 | 55.494 | 64.362 | 56.205 | 65.257 Secondary Core 2 ss.707 | 64.678 | 54.517 | 63.297 | 55.114 | 63.99 EL SEWEDY ELECTRIC PSP EPE/KAHRAMAA Name Mr. Mohamed abdullah Mr, Hariprasad.M Signature Sa —— ater Date 29/6 / 2017 29/6 / 2017 ELSEWEDY Test Report for ins Pinas ELECTRIC soe Voltage Transformer Of ross art PsP BAY C30 Project Name ‘System 1aakV Gis, [AL WUKAIR 11 SUBSTATION 132/11KV ‘Author / Prepared P&C TEAM Lang, REV. NO. Page/No.of pages DWG NO. AWKII-ESC-11-12-R004 En A Page 3 of 3 4. PT POLARITY CHECKED: OK 5. PT RATIO: 132000/\3 / 110/v3 Volts Circuit ret | Applied voltage (Volts) Measured voltage (Volts) Ratio error % R 1999.59 1.6706 0.26 Core 1] ¥ 1999.27 1.6705 0.27 B 1999.35 1.6703 0.25 R 1999.39 1.6703 0.25 Conia ify. 1999.52 1.6706 0.26 el 1999.57 1.6704 0.25 EL SEWEDY ELECTRIC PSP EPE/KAHRAMAA Name Mr. Mohamed abdullah Mr, Hariprasad.M Signature Ht ae epi Pate 29/6/2017 29 /6 / 2017 \ALWAKAIR 132-11\C30-RATIO-D706523A.xml: ‘Test Device: CPC 100 Serial Numbet LJST3T (V1) Date/Time: (06/29/2017 11:44:32 Overall assessment: n/a ‘Test Cards Overview: [rest Card ftype_|[paterTime [Results| Assessment] Overload] IRPH-CORE1-RATIO 1 |VTRatio]|06/29/2017 11:33:16llyes [n/a ino [RPH-CORE2-RATIO 1 | VTRatio]]06/29/2017 11:37:25}lyes [nfa Ino [YPH-CORE1-RATIO 1]|VTRatio]|06/29/2017 11:39:26]lyes [nfa [no [YPH-CORE2-RATIO 1]VTRatio}|06/29/2017 11:40:24]lyes [n/a no. |BPH-CORE1-RATIO 1] VTRatio}|06/29/2017 11:41:25}lyes nia no. |BPH-CORE2-RATIO 1]/VTRatio}}06/29/2017 11:42:59]lyes ina [no Test Cards: RPH-COREL-RATIO I: Card Type: VTRatio Date/Time: 06/29/2017 11:33:16 Overload: no Assessment: n/a Range: Nominal values: v Vsec.: Frequency: Vest: Automatic: Results: AC 2kV 132000/V3 V 110.0/V3 V 50.00 Hz 2000.0 V yes 1999.59 V 1.6706 V 0.00° 0.01% 132000/V3 V:110.2835/V3 V 0.26% OK RPH-CORE2-RATIO |: Card Type: VTRatio Date/Time: 06/29/2017 11:37:25 Overload: no Assessment: n/a Range: AC 2kV Nominal values: 1320003 V 110.03 V 50.00 Hz 2000.0 V Automatic: yes Results: V prim. 1999.39 V 0.00° Vssee. 1.6703 V 0.00° Ra 132000/¥3 V:110.2767/N3 V 0.25 % Polarity: OK. YPI-COREL-RATIO I: Card Type: VTRatio 06/29/2017 11:39:26 no AC 2kV 132000/¥3 V 110.0/N3 V Frequeney: 50.00 Hz Vest: 2000.0 V Automatie: yes Results: V prim: 1999.27 V 0.00° V secs: 1.6705 V o.o1e Ratio: 132000/V3 V:110.2946/V3 V 0.27 % Polarity: OK YPH-CORE2-RATIO I: Card Type: VTRatio Date/Time: 06/29/2017 11:40:24 Overload: no Assessment: n/a Range: AC 2kV Nominal values: V prim: 132000/V3 V Vee. 110.013 V Frequeney: 50,00 Hz Veest: 2000.0V Automat yes 1999.52 V 0.00 ° 1.6706 V o.o1° 132000/V3 V:110,2884/\3 V 0.26 % OK BPH-COREL-RATIO I; Card Type: VTRatio Date/Time: 06/29/2017 11:41:25 Overload: no Assessment: n/a Range AC2KV Nominal values: V prim: 132000/V3 V. V see.: 110.03 V Frequeney: 50,00 Hz V test: 2000.0 V Automatic: yes Result Y prim: 1999.35 V 0.00° V see. 1.6703 V 0.018 Ratio: 132000/V3 V:110.2786/\3 V 0.25 % Polarit OK BPH-CORE2-RATIO 1: Card Type: VTRatio Date/Time: 06/29/2017 11:42:59 Overload: no Assessment: n/a Range: AC 2kV Nominal values: Vprim.: 132000/V3 V Vsecs 110.0N3 V Frequency: 50,00 Hz. Viest: 2000.0 V Automatic: yes 1999.57 V 0.00° 1.6704 V 0.01 Ratio: 132000/V3 V:110.2701/¥3 V 0.25 % Polarity: OK \ALWAKAIR 132-11\C30-RESISTANCE-D706523A.xml: ‘Test Device: Serial Number: Date/Time: CPC 100 LIS737 (V1) 06/29/2017 11:24:31 Overall assessment: n/a Test Cards Overview: [Test Card [type _|[Daterrime ___} Results)[Assessment]Overload IRPH-COREI-RESISTANCE]RWinding| ao es Iva Ino IRPH-CORE2-RESISTANCE]RWinding| en Ives Iva Ino lyPH-COREI- 62972017 [RESISTANCE [Winding 14-32 eet | = [YPH-CORE2- ingl06/29/2017 eaiepace Winding oe es iva ho IBPH-COREI IRWinding| reese yes Ihva lho BPH-CORE2 Winding ot? pes iva Ino Test Cards: RPH-COREI-RESISTANCE: Card Type: RWinding Date/Time: 06/29/2017 11:07:23 Overload: no Assessment: n/a Range: test: DC6A 1.000 A 200.00 2 10,000 2 890.94 mA, 49.565 mV 55.633 m2 AA Deviation: 0.02% Ti 32.000 ‘Temperature compensation for copper: Tmeas.: 32.00°C Trek: 75.00°C Rref: 64.592 ma RPH-CORE2-RESISTANCE: Card Type: RWinding Date/Time: 06/29/2017 11:12:23 Overload: no Assessment: n/a Range: DC 6A Ttest: 1,000 A R 200.00 12 Rmax.: 10.0002 Results: Ipc: 903.16 mA voe: 50.312 mv R meas. 55.707 m2 0.10% Time: 46.000 Temperature compensation for copper T meas.: 32.00 °C 75.00°C 64.678 m2 Card Type: RWinding Date/Time: 06/29/2017 11:14:32 Overload: no Assessment: n/a Range: DC6A 1.000 A 200.00 pr 10.0002 AA 886.94 mA 49.167 mV 55.434 ma 0.02% 37.000 s ‘Temperature compensation for copper 32.00°C 75.00°C 64.362 ma YPH-CORE2-RESISTANCE: Card Type: RWinding Date/Time: 06/29/2017 11:16:38 Overload: no Assessment: n/a Range: DC 6A test: 1.0004 R min. 200.00 pa Rimax: 10.0002 Results: Ipc: 883.16 mA. voc: 48.147 mV R meas.: 54.517 m2 Deviation: 0.03 % Time: 25.000 s ‘Temperature compensation for copper: T meas.: 32.00°C T ref: 75.00°C R refs 63.297 mQ BPH-CoREI: Card Type: RWinding Date/Time: 06/29/2017 11:20:28 Overload: no nia DC6A 1.000 4 Rmin.: 200.00 wo Rimax: 10.000. Results: pc: 884.89 mA, voc: 49.735 mV Rimeas.: 56.205 ma Deviation 0.02 % Time: 40.000 s ‘Temperature compensation for copper: T mea 32.00°C Tref: 75.00°C Rref: 65.257 ma DPH-CORE2: Card Type: RWinding Date/Time: 06/29/2017 11:22:05 Overload: no Assessment: n/a Range: DC 6A test: 1.000 A 200.00 1a 10,0002 Results: 1D 885.18 mA v pc: 48.786 mV R meas: 55.114 mo Deviation: 0.03 % Time: 24.000 s ‘Temperature compensation for copper: T meas.: 32.00 °C 75.00 °C 63.990 m2 ‘A SITE ACCEPTANCE TEST REPORTS VOLUME NO: 1 FILE NO: 1.1 16. C40 VT TEST REPORT ELSEWEDY — Test Report for ELECTRIC | Voltage Transformer Of @ »& WE PSP PAYIC#O Project Name System 132kV GIS AL WOKAIR 11 SUBSTATION 132/11KV Author / Prepared ‘T&C TEAM Lang. [REV NO. | page/to.of pages DWG NO. AWKII-ESC-11-12-R004 En A Page | of 3 132 KV GIS Voltage transformer test report Objective: - this tests are performed on the VT's to determine it's (ratio error % , polarity , and winding resistance ) then compare it with reference values , and see if the error is within range or not. Test procedure: - perform insulation resistance test on VT primary and secondary windings and record the results. -using omicron CPC 100 perform the test for turns ratio by applying 2 KV AC on the VT primary winding and measure the secondary voltage then calculate the ratio error. using omicron CPC 100 perform the test for winding resistance by injecting current to the secondary winding terminal and measure the voltage across the secondary winding and calculate the resistance. Reference DWG: AWK 1 1-ESC-11-12-RO004 Equipment name | manufacturer Cal. date Due to Insulation Megger’ 70/121212/4304 1/3/2017 28/2/2018 resistance tester ‘CPC 100 ‘Omicron 2/8/2017 2/5/2018 Note: * Applicable standard IEC 61869-3. * Test shall be satisfied with approved specs and drawing, EL SEWEDY ELECTRIC PSP EPE/KAHRAMAA Name Mr, Mohamed abdullah Mr, Hariprasad M Signature Fe Warps Date 1/7/2017 1/7 / 2017 elsewepy ‘Test Report for va Fons TRIC Lo A Voltage Transformer Of a fo oat BAY C40 Project Name Sate Teak 18 [xc WORAIR 17 SUBSTATION 152/115 ‘Aula | Prepared. TC TEAM Lang. [REV-NO. | page No.of pages DWG NO. AWKII-ESC-11-12-R004 En a Page 2 of 3 CIRCUIT: CABLE FEEDE! 40 32°C 4. PT NAME PLATE DETAILS: Make TAKAOKA YOKO CO.,LTD Serial No./Year b706624A/2017 Ratio 132000/V3 / 110/V3 / 110/V3/ 110/V3 Class 449P = 14+3P - 143P Burden(VA) 100 - 100- 100 2. PT INSULATION RESISTANCE: (All Values in GQ) Applied Ref. Voltage RPH YPH BPH Piimary-Earth | 5000 V 145 [ 190 250 Pri -Core 1 121 88.5 221 1000 V Pri -Core 2 89.3 56 136 Core 1 - Earth 141 83.9 15 Core2-Eath | 500V 94 98 166 Coret -Core 2 150 98 123 3, PTWINDING RESISTANCE: Winding resistance (m®) Circuit Reference R-PH Y-PH B-PH 320 75°C 32°C 75°C 320 75°C Secondary Core 1 55.255, 64.154 58.074 67.426 57.131 66.331 Secondary Core 2 53.237 61.81 52.002 60.377 53.22 61.791 EL SEWEDY ELECTRIC PSP BPE/KAHRAMAA Name Mr. Mohamed abdullah Mr, Hariprasad. Mt Signature See eer] Date 1/7/2017 1/7] 2017 eLseweDy Test Report for sm Fo ELECTRIC | voltage Transformer Of sho pines eee PSP BAY C40 Trojet ame ‘System 132kV GIS |AL WUKAIR 11 SUBSTATION 132/11KV ‘Author / Prepared T&C TEAM tang. — [REV-NO- | Payeno.of pages DWG NO. AWKII-ESC-11-12-R004 En A Page 3 of 3 4, PT POLARITY CHECKED: OK 5. PT RATIO: 132000/V3 / 110/V3 Volts Circuit ref | Applied voltage (Volts) Measured voltage (Volts) Ratio error % R 1999.56 1.6707 0.26 Core 1| ¥ 1999.6 1.6708 0.27 8 1999.51 1.6707 027 R 1999.52 1.6708 0.26 Core 2| y 1999.47 1.6706 0.26 8 1999.56 1.6706 0.26 EL SEWEDY ELECTRIC PSP EPE/KAHRAMAA Name Mr. Mohamed abdullah Mr, Hariprasad. M Signature SHKat Wren Date 1/7 {2017 1/7 | 2017 \ALWAKAIR 132-11\C40-RATIO-D706524A.xml: ‘Test Device: CPC 100 Serial Number: LIS73T (V1) Date/Time: 07/01/2017 10:38:52 Overall assessment: n/a Test Cards Overview: [Test Card_|[Type Date/Time [Results||Assessment{|Overload IRPH-CORE1||VTRatio]07/01/2017 10:35:31 |lyes__|in/a Ino. IRPH-CORE2||V'TRatiol[07/01/2017 10:36:01 yes Inia lno. [YPH-CORE lV TRatiol(07/01/2017 10:36:32]|yes__|Inva Ino. YPH-CORE2]VTRatiol}07/01/2017 10:36:53]lyes wa Ino [BPH-CORE1||VTRatio|07/01/2017 10:37:41 Jfyes__|wa Ino. [BPH-CORE2]|V TRatio]|07/01/2017 10:38:08}lyes_||n/a Ino, ‘Test Cards: RPH-COREI: Card Type: VTRatio Date/Time: 07/01/2017 1 Overload: no Assessment: n/a Range: AC 2kV Nominal values: V prim: 1320003 V V sec. 110.03 V Frequeney: 50.00 Hz Vest: 2000.0 V Automatic: yes 1999.56 V 0.00° 1.6707 V -0.01° 132000/V3 V:110.2908/Y3 V 0.26% OK RPH-CORE2: Card Type: VTRatio Date/Time: 07/01/2017 10:36:01 Overload: no Assessment: n/a Range: AC 2kV Nominal values: 132000/V3 V 110.0/N3 V Freque! 50.00 Hz. Vitest: 2000.0 V Automatic: yes Results: V prim. 1999.52. V 0.00° 1.6706 V -0.01° 132000/V3 V:110.2831/V3 V 0.26 % Polarity: OK. YPH-COREI: Card Type: VTRatio Date/Time: 07/01/2017 10:36:32 Overload: no Assessment: n/a Rang AC 2kV 132000/V3 V Vsee.: 110.0/¥3 V Frequency: 50.00 Hz Vitest: 2000.0'V Automatic: yes Results: V prim.: 1999.60.V 0.00° V sec. 1.6708 V -0.01° Rati 132000/V3 V:110.2962/V3 V 0.27 % Polari OK YPH-coRE2: Card Type: VTRatio Date/Time: 07/01/2017 10: Overload: no Assessment: n/a Ran AC 2kV Nominal values: V prim.: 13200013 V Vsec: 110.03 V Frequen 50.00 Hz Viest: 2000.0 V Automat yes Results V prim. 1999.47 V 0.00° Vsec. 1.6706 V 0.00° Rati 132000/V3 V:110.2898/V3 V 0.26% Polarity: OK BPI-COREI: 07/01/2017 10:37:41 no Assessment: n/a Range: AC 2kV, Nominal values: V prim, 132000/V3 V Vsee.: 110.0/V3 V Frequency: 50.00 Hz V test: 2000.0 V Automat yes Results: 1999.51 V 0.00° 1.6707 V 0.018 132000/¥3 V:110.2929/V3 V 0.27% OK BPH-CORE2: Card Type: VTRatio Date/Time: 07/01/2017 10:38:08 Overload: no Assessment: n/a Ran; AC KV ‘Nominal values: V prim. 132000/V3 V Vssecs: 110.0/N3 V Frequeney: 50.00 Hz Viest: 2000.0V Automatic: yes Results: V prim: 1999.56 V 0.00° V sees: 1.6706 V 0.00° Ratio: 132000/V3 V:110.2839/\3 V 0.26 % Polarity: OK \ALWAKAIR 132-11\C40-RESISTANCE-D706524A.xml. ‘Test Device: CPC 100 Serial Number: 15731 (V1) Date/Time: 07/01/2017 10:33:43 Overall assessment: n/a Test Cards Overview: [Test Card [type _[patertime |Resutts|[Assessment]Overtoad] IRPH-CoRE! |fRWinding)07/01/2017 10:20:07] es _ [va 0 [RPH-CORE2|[RWinding|[07/01/2017 10:21:29]yes _ |va hro [YPH-COREI}RWinding)07/01/2017 10:28:16]yes _|iva iro [yPH-CORE2][RWinding)07/01/2017 10:26:30]yes [va hho [BPH-CoRE!][RWinding)07/01/2017 10:30-03]yes __|va fro [ber-corea][awinding}o7/01/2017 10:33:01lyes — |va ho Test Cards: RPH-COREL: Card Type: RWinding Date/Time: 07/01/2017 10:20:07 Overload: no DC6A 1.0004 200.00 wa 10.000. 893.95 mA 49.396 mV R meas: 55.255 mQ Deviation: 0.02% Time: 38.0005 ‘Temperature compensation for copper: T mea 32.00 °C T 75.00°C Rrefi: 64.154 mQ RPH-CORE2: Card Type: RWinding, Date/Time: 07/01/2017 10:21:29 Overload: no Assessment: n/a DC 6A 1,000.4 200.00 waa 10.0002 Ipc: 893.94 mA voce: 47.590 mv R meas. 53.237 mQ Deviation: 0.01% Time: 32,000 s Temperature compensation for copper: T meas. 32.00°C T ref. 75.00 °C 61.810 ma YPH-COREI: Card Type: RWinding Date/Time: 07/01/2017 10:28:16 Overloa Assessment: n/a Range: DC 6A I test: 1.000 A 200.00 pa 10.000. 2 no 904.32 mA 52.517 mV 58.074 ma 0.02 % 39.000s MA ‘Temperature compensation for copper: 32.00 °C 75.00 °C R ref: 67.426 m2 YPH-CORE2: Card Type: RWinding Date/Time: 07/01/2017 10:26:30 Overload: no Assessment: n/a Range: DC 6A Test: 1.000 4 Rmins 200.00 4.22 Rmax: 10.0002 Results: Ipc: 910.60 mA ve: 47.353 mV R meas.: 52,002 ma Deviation: 0.01 % Time: 39,000 s ‘Temperature compensation for copper: T meas: 32.00°C T ref. 75.00°C R ref: 60.377 ma BPH-COREI : Card Type: RWinding Date/Time: 07/01/2017 10:30:03 Overload: no Assessment: n/a Range: DC6A Lest: 1.000 4 Rimin: 200.00 ua Rimax: 10.000. Results: Ipc: 899.77 mA ype: 51.404 mV R meas: $7131 mQ Deviation: 0.02% Time: 53.000 s ‘Temperature compensation for copper: Tmeas.: 32.00 °C Tre: 75,00 °C Rref: 66.331 mQ 'BPH-CORE2: Card Type: RWinding Date/Time: 07/01/2017 10:33:01 Overload: no Assessment: n/a Range: DC 6A I test: 1.000. R min: 200.00 or 10.0002 895.93 mA 47.681 mV 53.220 ma Deviation: 0.02 % Time: 34.000 s Temperature compensation for copper: T meas: 32.00°C Tret: 75.00 °C Rret: 61.791 ma SITE ACCEPTANCE TEST REPORTS VOLUME NO: 1 FILE NO: 1.1 17. MAIN BUS1 VT(C166), MAIN BUS2 VT (C266), TEST REPORT eisewepy ‘Test Report for wwe Fn Voltage Transformer Of cone goer PSP BAY C16 ¢ Peat Name irae sae mS [ac WORAIR 11 SUBSTATION 193/11RV Author / Prepared T&C TEAM Lang. pee. Page/ No.of pages: DWGNO. AWKII-ESC-11-12-R004 En x Page | of 2 132 KV GIS Voltage transformer test report Objective: ~ this tests are performed on the VT's to determine it’s (ratio error % , polarity , and winding resistance ) then compare it with reference values , and see if the error is within range or not. Test procedure: ~ perform insulation resistance test on VT primary and secondary windings and record the results. -using omicron CPC 100 perform the test for turns ratio by applying 2 KV AC on the VT primary winding and measure the secondary voltage then calculate the ratio error. -using omicron CPC 100 perform the test for winding resistance by injecting current to the secondary winding terminal and measure the voltage across the secondary winding and calculate the resistance. Reference DWG: AWK11-ESC-11-12-R004 Equipment name | manufacturer S/N Cal. date’ Due to Insulation Megger 70/121212/4304 1/3/2017 28/2/2018 resistance tester oe ‘CPC 100 Omicron LIS73T 2/8/2017 2/5/2018 Note: * Applicable standard IEC 61869-3. ‘+ Test shall be satisfied with approved specs and drawing. EL SEWEDY ELECTRIC PSP EPE/KAHRAMAA Name ‘Mr. Mohamed abdullah Mr. Hariprasad. M [Signature Ses ane? Date 29/6 / 2017 29/6 / 2017 guseweny Test Report for wu PE Voltage Transformer Of as fe ar BAY C16 Traci System 132kV GIS [AL WUKAIR 11 SUBSTATION 132/11KV Author / Prepared ‘T&C TEAM Lang. REV NO; Page/No.of pages: DWG NO. AWKI1-ESC-11-12-R004 En A Page 2 of 2 CIRCUIT: METERING FEEDER: C16 1. PT NAME PLATE DETAILS: Amb. Temp: 32°C Make TAKAOKA YOKO CO.,LTD [ Serial No./Year 07065254/2017 Ratio 132000/V3 / 1101N3/ 110/N3/ 110/N3 Class 143P - 143P - 143P Burden(VA) 100 - 100 - 100 2. PT INSULATION RESISTANCE: (All Values in GO) Applied Ref. Voltage RPH YPH BPH Primary-Earth_| 5000 V 256 197 354 [-_Pri- Sec 7000 V 292 169) 808 Sec-Earth | 500V 124 280 405 3. PT WINDING RESISTANCE: Winding resistance (mQ) Circuit Reference RPH Y-PH B-PH 32°C 75°C 75°C 32°C 75°C Secondary Core 4 52.192 | 60.526 | 50415 | 58.536 | 61.128 | 69.362 4, PT POLARITY CHECKED: OK 5. PT RATIO: 132000/V3 / 110/V3 Volts Circuit ref | Applied voltage (Volts) Measured voltage (Volts) Ratio error % R 1999.58 1.6687 0.14 Core 1 | ¥ 1999.22 1.6683, 0.14 B 1999.49 1.6685 0.14 EL SEWEDY ELECTRIC PSP EPE/KAHRAMAA. Name Mr. Mohamed abdullah Mr. Hariprasad. M Signature ~ ou), Date 29 /6 / 2017 29/6 / 2017 \ALWAKAIR 132-11\C16-RATIO-D706525A.xml: ‘Test Device: PC 100 Serial Number: 5737 (V1) DateTime: 06/29/2017 15:17:13 ‘Overall assessment: n/a Test Cards Overview: [test Card|[type [Date/Time [Resuits||Assessment|Overtoadl [RPH TRatio|(06/29/2017 15:14:12]fyes_ [va 0 YPH___|[vTRatiol/o6/29/2017 15:14:38]|yes__|[a/a fro [BPH __||VTRatio}06/29/2017 15:15:10]yes _|[n/a lno Test Cards: RPH: Card Type: VTRatio Date/Time: 06/29/2017 15:14:12 Overload: no Assessment: n/a ‘Range: AC2kV Nominal values: V prim: 13200013 V Visec: 110.013 V Frequency: 50.00 Hz Vitest: 2000.0 V Automatic: yes 1999.58 V 0.00° 1.6687 V 0.00 132000/V3 V:110.1540/¥3 V 0.14% Polarity: OK YPH: Card Type: VTRatio Date/Time: 06/29/2017 15:14:38 AA » Overload: no Assessment: n/a AC 2kV 132000/V3 V z 110.03 V Frequency: 50.00 Hz Vitest: 2000.0 V Automat yes Result V prim. 1999.22. V 0.00° Vssec: 1.6683 V -0.01° Rati 132000/N3 V:110.1521/Y3 V 0.14% Polarity: OK BI Card Type: VTRatio Date/Time: 06/29/2017 15:15:10 Overload: no Assessment: n/a Ran; AC 2kV Nominal values: V prim.: 1320003 V Vee: 110.03 V Frequency: 50.00 Hz Viest: 2000.0 V Automati yes Results: V prim.: 1999.49 V 0.00° Vsec: 1.6685 V -0.02° Ratio: 132000/V3 V:110.1494/N3 V 0.14 % Polarity: OK A.A \ALWAKAIR 132-11\C16-RESISTANCE-D76525A.xml: ‘Test Device: CPC 100 Serial Number: LJS73T (V1) Date/Time: 06/29/2017 15:00:49 Overall assessment: n/a Test Cards Overview: [Test Card}{Type__|[Date/Time [Results| Assessment| Overload IRPH Winding}]06/29/2017 14:51:08|yes__|fva ino. [YPH___|RWinding06/29/2017 14:55:52|lyes __|fn/a [no BPH [RWinding|06/29/2017 14:57:18] yes __|[nva Ino Test Cards: RPA: Card Type: RWinding 06/29/2017 14:51:08 nto Assessment: n/a DC6A 1.000. A 200.00 no 10.000. 2 0.99136 A 51.682 mV 52.132 m2 0.03 % 30.000 s ‘Temperature compensation for copper: T meas; 32.00 °C T ref. 75.00 °C R ref: 60.528 mQ M.A ~ yen: Card Type: RWinding Date/Time: 06/29/2017 14:55:52 Overload: no Assessment: n/a Range: DC6A Ttest: 1.000 Rimin 200.00 wo Rmax 10,000 & Result Ibe: 0.97953 A, voc: 49,383 mV R mea 50.415 m2 Deviation: 0.02 % Time: 38.000 s ‘Temperature compensation for copper: T meas.: 32.00°C T refs 75.00°C R refs 58.535 mQ BPH: Card Type: RWinding Date/Time: 06/29/2017 14:57:18 no Overtoa Assessment: DC6A 1.000 A, 200.00 2 10.000 0.98326 A 50.272 mV 51.128 ma Deviation: 0.02 % Time: 24.000 s ‘Temperature compensation for copper: Tmeas.: 32.00°C. Trek: 75.00°C. Rret: 59.362 ma AA eLsewepy Test Report for ure Fins ELECTRIC | Voltage Transformer Of 0 pits PSP BAY C26 Project Name System Taakv GIs [AL WOKAIR 11 SUBSTATION 192/11KV ‘Author / Prepared ‘T&C TEAM tang. — [REV-NO. T page no.of pages DWG NO, AWKII-ESC-11-12-R004 En A Page | of 2 132 KV GIS Voltage tran: t report Objective: - this tests are performed on the VT's to determine it’s (ratio error % , polarity , and winding resistance ) then compare it with reference values , and see if the error is within range or not. Test procedure: - perform insulation resistance test on VT primary and secondary windings and record the results, -using omicron CPC 100 perform the test for tums ratio by applying 2 KV AC on the VT primary winding and measure the secondary voltage then calculate the ratio error. using omicron CPC 100 perform the test for winding resistance by injecting current to the secondary winding terminal and measure the voltage across the secondary winding and calculate the resistance. Reference DWG: AWK -ESC-11-12-R004 Equipment name | manufacturer S/N Cal, date Due to Insulation Megger 70/121212/4304 1/3/2017 28/2/2018 resistance tester ‘CPC 100 ‘Omicron LJ573T 2/5/2017 2/5/2018 Note: * Applicable standard IEC 61869-3. «Test shall be satisfied with approved specs and drawing. EL SEWEDY ELECTRIC PSP EPEE/KAHRAMAA Name Mr, Mohamed abduliah Me, Hariprasad. M ‘Signature Wacpra™ Date 1/7/2017 ELSEWEDY Test Report for uur ffl ELECTRIC | Voltage Transformer Of snorses glee PSP BAY C26 S Project Name System 13KV GIS [AL WOKAIR 11 SUBSTATION 192/11KV Author / Prepared T&C TEAM Lang. EYANO: Page/ No.of pages DWG NO. AWK11-ESC-11-12-R004 En A Page 2 of 2 CIRCUIT: METERING FEEDER: C26 Amb. Temp 32°C 1, PT NAME PLATE DETAILS: Make TAKAOKA YOKO CO.,LTD Serial No/Year D706526A/2017 Ratio 132000/\3 / 1 10/V3 1 110/N3/ 110/V3 Class 143P - 1+3P - 1+3P Burden(VA) 100 - 100 - 100 2. PT INSULATION RESISTANCE: (All Values in GQ) Applied Rot. use RPH YPH BPH Piimary-Earth | 5000 V 127 124 129 Pri-Sec | 1000 708 694 582 Sec-Earth | 500V 675 106 159 3. PT WINDING RESISTANCE: Winding resistance (m2) Circuit Reference R-PH 32°C 75°C ‘Secondary Core 1 51.127 | 59.361 B-PH 75°C 32°C 75°C 57.548 | 49.754 | 57.767 4. PT POLARITY CHECKED: OK 5. PT RATIO: 132000/V3 / 110/V3 Volts Circuit ref | Applied voltage (Volts) Measured voltage (Volts) Ratio error % | R 1999.44 1.6685 0.14 Core 1| ¥ 1999.56 1.6685 0.13, B 1999.56 1.6685 0.13 EL SEWEDY ELECTRIC PSP EPE/KAHRAMAA Name Mr. Mohamed abdullah Mr, Hariprasad. Signature Sz Gap? Date 1/7 [2017 1/7 / 2017 \ALWAKAIR 132-11\C26-RATIO-D706526A.xml: ‘Test Device: CPC 100 Serial Number: LIS73T (V1) Date/Time: 07/01/2017 09:42:02 Overall assessment: n/a Test Cards Overview: ‘Test Cardl[Type _|Date/Time [Results] Assessment] |Overload| IRPH___||VTRatiol}07/01/2017 09:40:35]lyes _ [v/a Ino. [YPH __||VTRatiol07/01/2017 09:41:00]fyes__||n/a Ino. [BPH ___||VTRatio07/01/2017 09:41:20]lyes_|In/a Ino Test Cards: RPH: Card Type: VTRatio Date/Time: 07/01/2017 09: Overload: no Assessment: n/a Range: AC 2kV Nominal values: 132000/V3 V 110.013 V Frequency: 50.00 Hz Vest: 2000.0 V Automatic: yes Results: V prim, 1999.44.V 0.00° Vsee.: 1.6685 V 0.00° Ratio: 13200013 V:110.1509/V3 V 0.14 % Polarity: OK YPH: Card Type: VTRatio Date/Time: 07/01/2017 09:41:00 Overload: no Assessment: n/a Range AC 2kV Nominal values: V prim: 132000/V3 V Vsec.: 110.0/V3 V Frequency: 50.00 Hz V test: 2000.0 V Autom: yes Resul ‘V prim. 1999.56 V 0.00° V sec, 1.6685 V 0.00° Rat 132000/V3 V:110.1442/V3 V 0.13 % Polarity: OK BPH: Card Type: VTRatio 0701/2017 09:41:20 V prim.: 132000/\3 V Vseei 110.0/N3 V Frequency: 50.00 Hz Viest: 2000.0 V Automatic: yes Results: 1999.56V 0.00° 1.6685 V 0.00° 132000/V3 V:110.1472/¥3 V 0.13 % Polarity: OK AA \ALWAKAIR 132-1 1\C26-RESISTANCE-D706526A.xml: Test Device: CPC 100 Serial Number: L1573T (V1) Date/Time: 07/01/2017 09:36:22 Overall assessment: n/a Test Cards Overvies [Test Card|ftype __|[Date/Time [Resuits|[Assessment|Overloadl IRPH |R Winding!|07/0 1/2017 09:30:52llyes [n/a [no |YPH [RWindingl|07/01/2017 09:32:40]lyes [fa no [BPH [RWinding}/07/01/2017 09:34:13|iyes wa Ino Test Cards: Ra: Card Type: RWinding Date/Time: 07/01/2017 09:30:52 Overload: no Assessment: ra Range: DC 6A I test: 1.0004 R min, 200.00 por 10.000. 948.78 mA 48.508 mV 51.127 ma Deviation: 0.03 % Time: 68.0005 ‘Temperature compensation for copper: T meas: 32.00 °C Prefs 75.00°C R ref: 59.361 mQ yen: Card Type: RWinding Date/Time: 07/01/2017 09:32:40 Overload: no Assessment: n/a Range: DC 6A Ttest: 1.0004 Rm 200.00 122 R imax. 10.000. Results: Ipc: 946.35 mA vpe: 46.907 mv Rimeas 49.566 m2 Deviation: 0.02% Time: 43.000 s ‘Temperature compensation for copper: T meas.: 32.00 °C T ref. 75.00 °C R refs: 57.548 mQ BPH: Card Type: RWinding Date/Time: 07/01/2017 09:34:13 Overload: no Assessment: n/a Range: DC 6A test: 1.000 A R min. 200.00 1 Rmax.: 10.000. Results: Ipc: 0.95214 A 47.373 mV 49.154 mQ 0.03% Time: 35.000 s ‘Temperature compensation for copper: Tmeas.: 32.00 °C Tref: Rref: 75.00 °C. 57.167 mo SITE ACCEPTANCE TEST REPORTS VOLUME NO: 1 FILE NO: 1.1 18. RESERVE BUS1 VT(C366), RESERVE BUS2 VT (C466), TEST REPORT gLSEWEDY Test Report for voi Foun ELECTRIC | voltage Transformer Of hme ates BAY C36 Praject Name Syatem Teak is [AL WOKAIR-1Y SUBSTATION 139/105 ‘Author / Prepared T&C TEAM Lang. REVLNO: Page/ No.of pages DWG NO. AWKII-ESC-11-12-R004 En A Page | of 2 132 KV GIS Voltage transformer test report ol ct ive: - this tests are performed on the VT's to determine it’s (ratio error % , polarity , and winding resistance ) then compare it with reference values , and see if the error is within range or not. Test procedure: - perform insulation resistance test on VT primary and secondary windings and record the results, -using omicron CPC 100 perform the test for turns ratio by applying 2 KV AC on the VT primary winding and measure the secondary voltage then calculate the ratio error. -using omicron CPC 100 perform the test for winding resistance by injecting current to the secondary winding terminal and measure the voltage across the secondary winding and calculate the resistance. Reference DWG: AWK11-ESC-11-12-R004 Equipment name | manufacturer S/N Cal. date Due to Insulation Megeer 70/121212/4304 | 1/3/2017 28/2/2018 resistance tester ‘PC 100 Omicron LJS73T 2/5/2017 2/5/2018 Note: + Applicable standard IEC 61869-3, + Test shall be satisfied with approved specs and drawing. EL SPWEDY ELECTRIC PSP EPE/KAHRAMAA Name Mr, Mohamed abdullah Mr. Hariprasad. M Signature FaL— Ge Date 29 /6 | 2017 29 16 / 2017 eLsewedy ‘Test Report for om PIE ELECTRIC | Voltage Transformer Of 0 pita PSP BAY C36 ______Preetname id System Teak ais [AL WOKAIR 11 SbpsTaTiON 193/118 ‘Author / Prepared T&C TEAM Lang. REV.NO. | page/No.of pages DWG NO. AWKII-ESC-11-12-R004 En A Page 2 of 2 CIRCUIT: METERING FEEDER: 1. PT NAME PLATE DETAILS: Amb. Temp 32°C 7 Make “TAKAOKA YOKO CO.,LTD Serial No./Year D706527A/2017 Ratio 132000/V3 / 110/N3 / 110/¥3/ 110N3 Class —_148P- 143P - 143P Burden(VA) 100 - 100 - 100 2. PT INSULATION RESISTANCE: (All Values in GQ) Applied Ref. Voltage RPH YPH BPH Piimary-Earth | 5000 V 332 231 350, Pri- Sec 1000 V 486 308 646 Sec-Earth | 500V 119 98.3 178 3. PT WINDING RESISTANCE: Winding resistance (mO) Circuit Reference RPH Y-PH B-PH 32°C 75°C 32°C 75°C 32°C 75°C ‘Secondary Core 1 52.896 | 61.415 | 51.676 | 59.682 | 60.108 | 58.178 4, PT POLARITY CHECKED: OK 5. PT RATIO: 132000/V3 / 110/V3 Volts. Circuit ref | Applied voltage (Volts) Measured voltage (Volts) Ratio error % 1999.4 1.6683 0.13 Core 1] ¥ 1999.52 1.6685 0.13 B 1999.53, 1.6684 0.13 EL SEWEDY ELECTRIC PSP EPE/KAHRAMAA Name Mr, Mohamed abdullah Mr, Hariprasad M ‘Signature Sal— Qin Date 29/6 / 2017 29 /6 / 2017 \ALWAKAIR 132-11\C36-RATIO-D76527A.xml: ‘Test Device: CPC 100 Serial Number: LIS73T (V1) Date/Time: 06/29/2017 15:13:19 Overall assessment: n/a Test Cards Overview: [Test Caral[type [Date/Time | Results] Assessment] Overload] RH __||vrRaviolo6/2972017 15:11-08]fyes Iva ho fyer |v rRatiolos29/2017 15:11:37]yes nla ho perv rRatiolos/2972017 15:12:13])yes a fo ‘Test Cards: RPH: Card Type: VTRatio Date/Time: 06/29/2017 15:11:08 Overload: no Assessment n/a Range: AC 2kV Nominal values: V prim.: 132000/V3 V V secu: 110.03 V Frequency: 50.00 Hz Vitest: 2000.0V Automatic: yes 1999.40. V 0.00 ° 1.6683 V -0.02° 132000/V3 V:110.1382/¥3 V 0.13 % OK YPH: Card Type: VTRatio Date/Time: 06/29/2017 15:11:37 Assessmen Range: AC 2kV Nominal values: V prim: 13200013 V Vssec.: 110.0/V3 V Frequency: 50.00 Hz Vitest: 2000.0 V Automatic: yes 1999.52. V 0.00° 1.6685 V -0.02° 132000/13 V:110.1471/V3 V 0.13 % OK Date/Time: 06/29/2017 15:12:13 Overload: no Assessment: n/a Rang AC 2kV Nominal values: V prim; 132000/V3 V V sees: 110.03 v Frequeney: 50.00 Hz V test: 2000.0V Automatic: yes Result Vp 1999.53 V 0.00° V see: 1.6684 V -0.01° Rati 132000/V3 V:110.1409/V3 V 0.13 9% Polarity: OK \ALWAKAIR 132-11\C36-RESISTANCE-D76527A.xml Test Device: CPC 100 Serial Number: LJS73T (V1) Date/Time: 06/29/2017 15:08:47 Overall assessment: n/a ‘Test Cards Overview: [rest Card|type [Date/Time [Results|[Assessment|Overtoadl [RPH___|[RWindingllos/29/2017 15:04:43] yes n/a Iho. YPH _|[RWinding|o6/2972017 15:06:18] yes Java hho [BPH___|[RWindingl[06/292017 15:07:25]ves via Ino Test Cards: Rei: Card Type: RWinding 06/29/2017 15:04:43, no DC 6A 1.000 A, 200.00 12 10.000 2 1.00453 A, 53.135 mV 52.896 mQ 0.05 % 21.000 s Temperature compensation for copper: T mea: 32.00 °C. Tre 75.00 °C Rre 61.415 ma. yen: Card Type: RWinding Date/Time: 06/29/2017 15:06:18 Overload: no Assessment: n/a Range: Ttest: Rmin.: DC 6A 1.000 4 200.00 wo 10,000 2 0.96208 A 49.620 mV 51.576 ma 0.03 % 25.000 s ‘Temperature compensation for copper: T meas.: 32.00 °C. T ref: 75.00°C. R ref, 59.882 mQ BPH: Card Type: RWinding Date/Time: 06/29/2017 15:07: 25 Overload: no Assessment: n/a Range: DC 6A Ties 1.000.A R min 200.00 par Rmax.: 10.000. Results: Ipc: 0.96748.A 48.478 mV 30.108 ma 0.02% 28.000 s ‘Temperature compensation for copper: Tmeas.: 32.00°C 75.00°C 58.178 ma — ELSEWEDY Test Report for ail ME ELECTRIC | Voltage Transformer Of ere aes PsP BAY CAG Project Name System 132RV GIS [AL WUKAIR 11 SUBSTATION 132/11KV Author / Prepared T&C TEAM Lang, [REV-NO. | page/No.of pages DWONO, AWKII-ESC-11-12-R004 En. A Page | of 2 132 KV GIS Voltage transformer test report - this tests are performed on the VT's to determine it's (ratio error % , polarity , and winding resistance ) then compare it with reference values , and see if the error is within range or not. Test procedure: ~ perform insulation resistance test on VT primary and secondary windings and record the results, using omicron CPC 100 perform the test for tums ratio by applying 2 KV AC on the VT primary winding and measure the secondary voltage then calculate the ratio error. -using omicron CPC 100 perform the test for winding resistance by injecting current to the secondary winding terminal and measure the voltage across the secondary winding and calculate the resistance. Reference DWG: AWK 1I-ESC-11-12-R004 Equipment name | manufacturer S/N Cal. date Due to Insulation Megger 70/121212/4304| 1/3/2017 28/2/2018 resistance tester CPC 100 Omicron LIS73T 2/5/2017 2/5/2018 Note: ‘* Applicable standard IEC 61869-3, ‘+ Test shall be satisfied with approved specs and drawing. EL SEWEDY ELECTRIC PSP EPE/KAHRAMAA, Name Mr. Mohamed abdullah Mr. Hariprasad.M Signature i ae Np Date 1/7 (2017 1/7/2017 giseweny Test Report for uu iE Voltage Transformer Of snonhe Bae aa BAY C46 é Project Name System 192kV GIs [AL WOKAIR 11 SUBSTATION 132/11KV ‘Author / Prepared TC TEAM tang, [REV-NOT page No.of pages WG NO. AWKII-ESC-11-12-R004 Ba a Page 2 of 2 CIRCUIT: METERING FEEDER: C46 Amb. Temp: 32°C 1. PT NAME PLATE DETAILS: Make TAKAOKA YOKO CO.,LTD 1 Serial No./Year 0706528A/2017 Ratio 132000/N3 / 110NN3 / 110/N3/ 110/N3 Class 1+3P- 143 - 143P Burden(VA) 4100 - 100 - 100 2. PT INSULATION RESISTANCE. (All Values in GQ) Applied Ref. Voltage RPH YPH BPH Piimary-Earth_| 5000 V 107 136 137 Pri- Sec 1000 V 826 1000 1000 Sec-Earth | 500V 125 100 124 3. PT WINDING RESISTANCE: D___ Winding resistance Circuit Reference R-PH Y-PH BPH 32°C 75°C 32°C 75°C 32°C 75°C ‘Secondary Core 1 52.606 | 61.31 | 60.477 | 58.606 | 560.645 | 58.801 4. PT POLARITY CHECKED: OK _5. PT RATIO: 132000/13 / 110/13 Volts Circuitref | Applied voltage (Volts) Measured voltage (Volts) Ratio error % R 1999.79 1.6688 0.14 Core 1] ¥ 1999.72 1.6888 0.14 B 1999.4 1.6684 013 EL SEWEDY ELECTRIC PSP EPE/KAHRAMAA Name Mr. Mohamed abdullah Mr. Hariprasad. Signature Sek Wyo Date 1/7/2017 1/7/2017 \ALWAKAIR 132-11\C46-RATIO-D706528A.xml: ‘Test Device: CPC 100 Serial Number: LJS73T (V1) Date/Time: 07/01/2017 09:39:52 ‘Overall assessment: n/a ‘Test Cards Overview: [rest Card} type [Date/Time [Results] Assessment} Overload] [RPH |V'TRatio}07/01/2017 09:38:02|lves [n/a [no \YPH |VTRatio}|07/01/2017 09:38:28}lyes [n/a no |BPH [VTRatio}}07/01/2017 09:38:54|lyes [n/a no Test Cards: Ren: Card Type: VTRatio Date/Time: 07/01/2017 09:38:02 Overload: no Assessment: n/a AC 2kV 132000N3 V 110.043 V Frequeney: 50,00 Hz Vest: 2000.0 V Automatic: yes 1999.79 V 0.00° 1.6688 V 0.00° Ratio: 132000/V3 V:110.1504/¥3 V 0.14 % Polarity: OK YPH: Card Type: VTRatio Date/Time: 07/01/2017 09:38:28 ALA Overload: no Assessment: n/a Range: AC 2kV Nominal values: V prim. 132000/N3 V Vsec. 110.03 V Frequency: 50.00 Hz Vitest: 2000.0 V Automati yes Results: V prim. 1999.72 V 0.00° Vsee: 1.6688 V ole Rat 132000/¥3 V:110.1556/V3 V 0.14 % Polarity: OK BPH: Card Type: VTRatio Date/Time: 07/01/2017 09:38:54 Overload: no Assessment: n/a AC 2kV 13200013 V 110.0/N3 V Frequency: 50.00 Hz Vitest: 2000.0 V Automatic: yes 1999.40 V 0.00° 1.6684 V 0.00° 132000/V3 V:110.1471/¥3 V 0.13 % OK \ALWAKAIR 132-11\C46-RESISTANCE-D706528A.. ‘Test Device: Pc 100 Serial Number: 11573 (V1) Date/Time: 07/01/2017 09:28:40 Overall assessment: n/a Test Cards Overview: [Test Card|Type Date/Time [Results [Assessment] Overload] IRPH___|[kWinding07/01/2017 09:22:11] ves n/a no PH __|[RWindingl07/01/2017 09.23:50]yes Iva no [pe |Rwindinglo7/01/2017 09:25.09]yes ava 0 Test Cards: Ren: Card Type: RWinding Date/Time: 07/01/2017 09:22:11 Overload: no Assessment: n/a Range: DC 6A T test: 1,000.4 R mins 200.00 wo R max: 10.0000 Resul 1pc: 940.20 mA voc: 49.648 mv R meas. 52.806 ma Deviai 0.01 % Time: 25,000 s ‘Temperature compensation for copper: T meas 32.00°C T refs 75.00°C R refs 61.310 ma WA PH: Card Type: RWinding Date/Time: 07/01/2017 09:23:50 Overload: no Assessments n/a DC 6A 1,000 A 200.00 po 10.000 2 948.64 mA 47.884 mV R meas: 50.477 ma Deviation: 0.02 % Time: 38.000 s Temperature compensation for copper: T meas.: 32.00 °C T ref. 75.00 °C R ref: 58.606 mQ BPH: Card Type: RWinding Date/Time: 07/01/2017 09:25:09 Overload: no Assessment: n/a Range: DC6A Itest: 1.000 A R min: 200.00 po R max.: 10,000 2 937.24 mA 47.466 mV 50.645 m2 0.04% 42.000 s ‘Temperature compensation for copper 32.00°C Trek: Rref.: 75.00 °C. 58.801 ma

You might also like