You are on page 1of 1

RESTORE FILES ON TRIA 6000/4000 CONTROL

1/FORMAT THE RAMDISK (ONLY IF ALL DATA ARE LOST):


FILES, UNIT MENU, CURSOR ON 'RAMDISK', FORMAT UNIT,
WRITE 'FORMAT'

2/INSERT THE PASSWORD 'MORBI':


SERVICES, NEXT MENU, USER PASSWORD, WRITE 'MORBI',
CONFIRM.

3/SERVICES, MACHINE SETUP, LANGUAGE SETUP, PRESS THE 4TH


FUNCTION KEY (BLANK), WRITE 1189178, CONFIRM.
RESTART THE CONTROL (POWER OFF/ON).

4/INSERT THE PLC DISK SUPPLIED WITH THE MACHINE, SERVICES,


PLC MENU, PROGRAMS FILE, LOAD PROGRAM.

5/PREVIOUS MENU,CLEAR MEMORY,REGISTERS R, REGISTERS L,COUNTERS,


TIMERS,RETENTIVE MEMORY, PREVIOUS MENU

6/PREVIOUS MENU, UTILITY, EDIT MESSAGES, LOAD FROM UNIT,


SELECT YOUR LANGUAGE, CONFIRM.

7/PREVIOUS MENU, PUSH 'RUN/STOP',


THE SCREEN WILL SHOW: PLC RUNNING
PROGRAM VALID

8/INSERT THE PARAMETERS DISK,


EDITOR , PARAMETERS, LOAD ALL

9/LOAD THE TOOL DATA (DEF), PROGRAMS AND LISTS FROM DISK