You are on page 1of 19

Digital Tachometers/Sensors

and Peripherals

LG/SP/MP/RP series
FV/FT/PA/TM series
Select the rotation detector/rotation display unit that is optimal for your needs from the wide range of products that Ono Sokki is proud to offer.

Rotation Detector Selection Guide • Measures


Photoelectric Rotation Detector
• a)Rotary Encoder-Features
Small rotation torque
the rotation speed either by
utilizing the light reflected from reflective
b) Capable of measuring large P/R values; wide selection range tape, or from the contrast in the light
c) Can perform detection of low-speed rotations (close to zero) received that is caused by the color of
d) Choice of two types of power supply depending on the model, the shaft or by a difference in level.
AC or DC
Cable (P.34-35 )
e) Wide selection of models for different applications
• Features
Photoelectric Rotation Detector-
When using a rotary encoder with a 12 VDC drive
Rotary Encoder a) Sensing is performed with minimal
Tachometer
SP-405ZA (P.17) load on the rotating shaft.
TM-3100 series (P.18-20) b) Since output is generally performed
TM-5100 (P.21) through an amplifier, the waveform is
constant and stable.

Coupling (P.33) Digital Tachometer


TM-3100 series (P.18-20)
Cable (P.34-35)
TM-5100 (P.21)
Cable (P.34-35 )

Cable (P.34-35) Photoelectric Rotation Detector


Tachometer LG-9200/930 (P.14)
TM-3100 series (P.18-20) Cable (P.34-35 ) FS-540/542/5500, FG-1300 (P.15)

Reversible Counter Digital Tachometer


RV-3150 (P.29) TM-3100 series (P.18-20)
Roller Encoder TM-5100 (P.21)
RP-7400 series (P.28)

Electromagnetic Rotation Detector


(Internal Gear Type) Coupling (P.33) • This
Line Speedometer
is a roller-type detector that
MP-800 series (P.13) can measure speed simply by being
applied to the running line.
Handheld Digital Tachometer
HT series (P.24-27)

• (Internal
Electromagnetic Rotation Detector
Gear Type)- Features
a) Easy detection by direct connection to the rotating shaft. A flexile
Contact type
coupling is recommended for the direct connection method.
b) Non-contact detection provided inside the detector.
c) Superb rigidity and environmental resistance; high durability Roller Encoder
d) No power supply required. RP-7400 series (P.28) Cable (P.34-35 ) Non-contact type
e) Provides stable measurement, particularly at the lower limit of the
measurement range, when compared to the external gear type.

• The
Electromagnetic Rotation Detector
principle is the same as that for a generator
Magnetoelectric Rotation Detector
where the magnet and coil are unified. If the
detector is brought near the vicinity of a rotating
Detection (External Gear Type)
object such as a ferromagnetic gear with
gear MP-981/9820 (P.12)
AP-981 (P.12)
protuberances, the detector's magnetic force is
affected, and an alternating current with peaks •(External
Electromagnetic Rotation Detector
corresponding to the number of teeth is
Gear Type)- Features
a) Non-contact detection enables Electromagnetic Rotation Detector • (External
Magnetoelectric Rotation Detector
generated. If the number of gear teeth is 60, the measurement even of high-speed rotations (External Gear Type) Gear Type)
detector becomes a 60 P/R rotation detector. It incorporates a magneto-resistive element, a
b) Superb rigidity and environmental MP-900/9000 series (P.7-11)
permanent magnet, a DC amplifier, and a voltage Digital Tachometer
resistance; high durability
regulator inside, and is a magnet responsive TM-3100 series (P.18-20)
c) No power supply required (excluding
type (its counter value varies depending on TM-5100 (P.21)
MP-981, 9820, AP-981)
magnetic flux). Can detect as a square wave
d) P/R selectable ( the number of detector
output of the same amplitude from ultra low
Correct electromagnetic detector waveform gear teeth becomes the P/R value)
speed to high speed.
e) The mounting position is enabled simply by Cable (P.34-35 )
attaching the gear to the target Hi
measurement object.

Lo
Digital Tachometer
Correct waveform of magnetoelectric type
TM-3100 series (P.18-20) (Note) Rotation display value on the tachometer
rotation detector
TM-5100 (P.21)
indicates rotation speed.

2 3
Rotation Display Unit Selection Guide CONTENTS
Output, Power Requirement
Appearance Model No. Specifications, (Power Supply for the Compatible Detectors Page No.
etc. Detector)

TM-3110 Display only 100 to 240 VAC MP series p. 18-20 Rotation Detector Selection Guide 2,3 Handheld Tachometer
(12 VDC/100 mA) SP-405ZA Rotation Display Unit Selection Guide 4 Advanced handheld tachometer
LG series FFT calculation type FT-7200 24
TM-3120 BCD output
For
RP series Rotation Detector
General-Purpose Notes on Detection Gears 6 Handheld Digital Tachometer
Model TM-3130 Analog output Electromagnetic Type Rotation Detector 7 Multifunction type HT-5500 25
Electromagnetic Type (External Gear Type) [Modules 1 to 3] General-purpose use (contact) HT-3200 26
TM-3140 Comparator output General-purpose type MP-9100 7 to 11 General-purpose use (non-contact) HT-4200 26
With a directly attached cable MP-911 7 to 11 Speedometer HT-5510 27
Measurable for high speed rotation MP-9120 7 to 11 High rotation speed HR-6800 27
TM-5100 BCD output 100 to 240 VAC MP series p. 21 Oil-proof type MP-930 7 to 11
Analog output (5 VDC/150 mA) LG series Oil-proof/Heat-resistant type MP-935 7 to 11 Related Products
Comparator output (Total of A and B RP series (up to 150 °C) Elevator Speedometer
RS-232C channels) Heat-resistant type MP-936 7 to 11 Handheld type EC-2100 28
Multifunction (up to 220 °C)
2-channel calculation (12 VDC /150 mA)
Model
(For each A and B Long body type (105 mm) MP-940A 7 to 11 Line Speedometer (Roller Encoder)
channel) Long body type (81 mm) MP-954 7 to 11 Low-to-medium speed RP-7400 series 28
Compact type (M12) MP-950 7 to 11
Compact type (M8) MP-962 7 to 11 Length Meter
Ultra-compact type (M5) MP-992 7 to 11 Reversible counter RV-3150 29
FT-2500 Analog output 100 to 240 VAC FT-0501 (Rotation p. 22- 23 [Compact module]
Comparator output (12 VDC/100 mA) detector for DC motor) For modules 0.5 to1 MP-9200 7 to 11 F/V Converter
Pulse output Sound/vibration sensors [Medium module] General-purpose type FV-1100 30
RS-232C For modules 3 to 10 MP-963 7 to 11 High response type FV-1500 31
Advanced FFT calculation
Model Magnetoelectric Type (External Gear Type) Isolated Signal Amplifier
Low-to-medium speeds MP-981 12 Signal amplifier PA-150 32
High speeds MP-9820 12 Signal amplifier PA-330Z 32
Acid-proof/water proof AP-981 12
Coupling Selection Guide 33
Note1: Please refer to "Table of Signal Cable" on page 34 and 35 to select the suitable signal cable. Electromagnetic Type (Built-in Gear Type) Table of Signal Cable 34, 35
Note2: Please contact your nearest distributors or Ono Sokki sales office for the separated brochures of FT-2500. Low-to-medium speed MP-810/820/830/837B 13

Photoelectric Type
Compact type LG-9200 14
Long distance detection LG-930 14
Optical Fiber FS-540/542/5500, FG-1300 15

Application
Application 16

Rotary Encoders
Ultra-compact type SP-405ZA 17

Rotation Display Unit


General-purpose Use
Display only TM-3110 18 to 20
BCD output TM-3120 18 to 20
Analog output TM-3130 18 to 20
Comparator output TM-3140 18 to 20

Multifunction Type
Multifunction tachometer TM-5100 21

Advanced Model
Advanced tachometer FT-2500 22, 23

4 5
Rotation Detector
Electromagnetic Type Rotation Detector MP-900/9000 series
Notes on Detection Gears By bringing the MP-900/9000 series close to the tooth tip, it detects the frequency signal proportional to the rotation speed (sine wave output).
•Detection Gear
In general, gear made with soft metals (S45C, SS400, etc.) is used as a detection gear, Detector Detector
You can select according to the purpose from wide selection, such as general purpose type, special type including oil proof / heat resistant type. 
Extension cable, signal cable, connector are sold separately (See P34, 35).
which has magnetic body and large magnetic permeability.
Rotation Detectors Notes on Detection Gears

Rotation Detectors External Gear Type


•Shape of a Detection Gear
Fig.1 shows detector output waveforms from various types of external rotors (detection
Mounting method

Detector
gears etc.)
Detector Detector
Involute gear is the most suitable for detection gear.
*Note
1. Distortion might appear in output waveform, such as high frequency distortion when triangular
teeth / square teeth / round teeth / partially missing teeth are used.
2. If the gear is magnetized, output voltage decreases or the abnormal waveform is output due to
interference with the permanent magnet inside the detector.
Fig. 1 Various teeth shapes and
Abbreviation of gears: M=Module Z=number of teeth D= diameter of gear output waveforms
Detection gear
D N (r/min) × Z (number of teeth)
M= = C (Hz) When Z=60, N=C Mounting fixture (not included)
Z+2 60 (s)

•Shape of the gear for the MP-981 and the mounting method
(1) Output signals according to the
shape of the gear (2) Mounting method
•Features • Compact type
MP-950
• General-purpose type •Compact (M12), directly attached cable 0.5 m
(A) Involute gear Please avoid the mounting configurations
MP-9100
(A) (B) •Low cost and popular type • Compact type
M=2 M=1 shown in the figures left , as they will cause
Amp reciprocal magnetic interference. MP-962
waveform In the case of (A), a gear with a different module
• Direct attached cable type •Compact (M8), directly attached cable 0.5 m
is mounted in the vicinity of the MP-981. MP-911
Output • Ultra-compact type
waveform In the case of (B), two or more MP-981 units are •Cable 5m direct attached type of MP-9100
mounted within the vicinity of one gear. (cable: 3D-2V) MP-992
MP-981
(B) Spur gear MP-981
×2 units •Ultra-compact (M5), directly attached cable 0.5 m
• Low impedance (high-speed rotation type)
Amp MP-9120 • Compact module type
waveform
(3) How to use a custom gear (5) How to use a gear when M = 3 or more •Noise-resistant due to low impedance MP-9200
Output •Adapted for detection in high speed range •For module 0.5 to 1
waveform
•Same size as MP-9100 • Medium module type
(C) Custom gear 1P/1R
Reduce the tooth width • Oil-proof type MP-963
to 2 mm or less
20 mm (Example) MP-930 •For module 3 to 10
Amp M = 16 •Conforms to Japan Electrical Manufacturers Association (JEM)
or waveform
Output
D = 80
Z = 5P/R
standard (old), JEM-1030-1983*1 oil proof type •Standard detection gear
waveform •Direct attached cable 0.5 m MP-001 (ø = 62)
• Oil proof and heat-resistant type •Module 1, 60 teeth
Since two pulses may be output for one tooth (4) How to calculate Module M
in the case of (B) and (C) in the figure above, Reduce the tooth width this
MP-935
(B) and (C) are not suitable for use as a This calculation is for involute gears only dimension to 2mm or less •Conforms to Japan Electrical Manufacturers Association (JEM)
detection gear. Reference pitch circle diameter standard (old), JEM-1030-1983*1, oil proof type 
Module M = –––––– •Heat resistant cable up to 150 °C
Number of teeth
•1 m directly attached type

Electromagnetic Rotation Detectors and Magnetoelectric Rotation Detectors • Heat resistant type
MP-936
Non-contact type
Electromagnetic Rotation Detectors (MP-900/MP-9000 series) Magnetoelectric Rotation Detectors (MP-981/9820, AP-981) 0.5 to 1 mm
•Heat resistant up to 220 °C
V •Heat resistant cable 1 m directly attached type
Magnetoresistive element
gear
R1 • Long body type
coil coil
R − Waveform Output MP-940A
Output
Magnet yoke gear Magnet yoke + shaping circuit •Long body type of 105 mm mounting section, suitable for the
R2 V
DC Amp IND rotation detection of the rotating object deeply installed.
Regulator LED Drive
circuit
• Long body type
Low magneto-resistant position High magneto-resistant position Gap
VIN: DC12 V±2V MP-954
Different depending on the model
Electromagnetic Rotation Detector generates frequency signal of proportional Magneto-electric rotation detector is made by applying a magneto-resistive •Long body type of 81 mm mounting section, suitable for the (See P.9)
to the rotation speed by bringing it close to the tooth tip of the detection gear element whose resistance value varies depending on the intensity of the rotation detection of the rotating object deeply installed.
attached to the rotating shaft. It consists of a permanent magnet, a detection magnetic field. •Mounting screw size is same as MP-950
coil, and a yoke. Normally, a constant magnetic field is applied by a magnet, and the change in
When a magnetic material approaches in the vicinity of the yoke, the magnetic the magnetic field when the detection gear approaches the element is detected •Directly attached cable 0.5 m
flux passing through the detection coil changes, and an induced voltage of as a change in the resistance value. *1 Protective type F: Not affected harmful by oil droplets/oil spill from any direction.
frequency proportional to the change is generated in the detection coil. Changes in resistance value (= differential output) is detected and its signal is
Magnetic flux pulsates "frequency f = rotation speed x gear". Therefore, this will amplified by a DC amplifier. The output of the DC amplifier goes through a
be output as the rotation signal of the detector. waveform shaping circuit and is made into a rectangular wave.
Features are as follows. Magneto-resistive element is arranged at the tip of
1. Easy structure the detector. For correct detection, it is necessary
2. No power supply required that the detection surface and the gear surface face
3. Compact each other with the proper direction and position. As a * When the electromagnetic type rotation detector MP series is used especially in the place where great importance is placed on reliability,
4. No need for maintenance guide, the detector is marked with an alignment mark. the technical consultation is required.
It provides reliable rotation measurement and is widely used in many ways. (power supply: DC 12 ± 2 V)
Please consult your nearest distributor or Ono Sokki sales office nearby.

6
7
•MP-900/9000 series specifications •The relationship between the gap and detection rotation speed
(1) The relationship between the gap from the detector to the detection gear and the detection range (lowest measurable value) is given in the
Detectors General-purpose General-purpose Low impedance Oil-proof Oil-proof/Heat- Heat-resistant
(With cable (High-speed (With cable resistant (150 °C) (220 °C)
tables below.
Rotation Detectors External Gear Type

Rotation Detectors External Gear Type


attached) rotation type) attached) (With cable attached) (With cable attached) (2) The rotation speed range is that for which an output voltage of 0.5 Vp-p or more can be maintained. (load resistance = 10 kΩ)
Items MP-9100 MP-911 MP-9120 MP-930 MP-935 MP-936 (3) The rotation speed that can be measured varies according to the type of display unit used.
1
DC resistance value (Ω)* 850 to 950 85 to 105 850 to 950 600 to 700 800 to 900
• MP-900/9000 series measureable rotation speed (r/min)
Inductance (mH)[1kHz, T.Y.P] 300 30 300 270 370 * When using a detection gear with 60 teeth
Impedance (Ω)[1kHz, T.Y.P] 2k 240 2k 1.8 k 2.5 k Lower limit of rotation speed
Upper limit of
Output voltage (Vp-p)[1kHz, T.Y.P]* 2
2.0 or more Model Module M=1 M=1.5 M=2 rotation speed
Detectable frequency range (Hz) *3, *4 200 to 35,000 200 to 80,000 200 to 35,000 300 to 35,000 Gap 0.5 1 0.5 1 0.5 1

Detecting gear module 1 to 3 MP- 9100 200 500 50 300 30 100 35,000

Operating temperature range -10 to 90 °C -10 to 150 °C -10 to 220 °C 911 200 500 50 300 30 100 35,000
2 5
Vibration resistance (m/s )* 196 9120 200 500 50 300 30 100 80,000
2 6
Shock resistance (m/s )* 1,960 930 200 500 50 300 30 100 35,000

Weight (g) Approx. 90 Approx. 300 Approx. 90 Approx. 100 935 300 1200 75 300 40 100 35,000
(Including cable) (Including cable)
936 300 1000 75 300 40 100 35,000
Surrounding magnetic field (T) 0.03 or less 0.02 or less
940A 300 1200 80 300 50 130 35,000

950 300 1000 100 300 60 150 35,000


Detectors Long body Long body Compact type Compact type Ultra-compact type For small For medium
(With cable (With cable (With cable (With cable modules modules 954 300 1200 100 300 60 150 35,000
attached) attached) attached) attached)
962 400 1500 140 420 80 200 35,000
Items MP-940A MP-954 MP-950 MP-962 MP-992 MP-9200 MP-963

DC resistance (Ω)*1 500 to 600 2.1 to 2.3 k 1.25 to 1.45 k 160 to 190 850 to 950 3.7 to 4 k Module M=1 M=1.5 M=2 Upper limit of
Model
Inductance (mH)[1kHz, T.Y.P] 270 400 210 25 300 1800 Gap 0.2 0.5 0.2 0.5 0.2 0.5
rotation speed

Impedance (Ω)[1kHz, T.Y.P] 1.8 k 3.5 k 2.1 k 250 2k 16 k MP- 992 400 1000 230 600 140 330 100,000
Output voltage (Vp-p)[1kHz, T.Y.P]* 2
2.0 or more 1.5 or more 0.5 or more 0.6 or more (M=0.75) 2.5 or more
3, 4
Detectable frequency range (Hz)* * 300 to 35,000 400 to 35,000 400 to 100,000 300 to 35,000 45 to 15,000 Module M=0.5 M=0.75 Upper limit of
Model
rotation speed
Detecting gear module 1 to 3 0.5 to 1 3 to 10 Gap 0.2 0.2 0.5

Operating temperature range -10 to 90 °C -10 to 120 °C -10 to 90 °C MP- 9200 2,000 300 1,000 35,000

Vibration resistance (m/s2)*5 196 147


Module M=3 M=5 M=7.5 Upper limit of
2 6
Shock resistance (m/s )* 1,960 Model
rotation speed
Gap 1 2 1 2 1 2
Weight (g) Approx. 150 Approx. 90 Approx. 70 Approx. 50 Approx. 3 Approx. 90 Approx. 200
(Including cable) (Including cable) (Including cable) (Including cable) MP- 963 45 90 25 50 20 45 15,000

Surrounding magnetic field (T) Up to 0.01 Up to 0.005 Up to 0.001 Up to 0.005 Up to 0.03 *The data is standard value and do not warrant the behavior. When using our rotation detectors.

*1: The temperature coefficient for the DC resistance value: 0.4% / °C


*2: Load resistance: 10 kΩ, M=1, gap=0.5 mm (As for MP-963; load resistance 10 kΩ, M=3, gap=1.5 mm)
*3: When using the 60 P/R detection gear, the value for frequency [Hz] and value for rotation speed [r/min] are the same.
*4: When using the Ono Sokki standard MP-001 detection gear (when using a gear with M=3 for MP-963, M=0.75 for MP-9200)
MP-9100/911/930 output voltage characteristics (G=0.5 mm)
*5: JIS E 4031, five types, 40 Hz, two hours in each of the X and Y directions; four hours in the Z direction
*6: Three times each in the X, Y and Z directions VP–P (per cable length)
10
5m Signal cable (3C2V)

• Notes on the Detection Gear


a) Gap between the detector and the detection gear
d) Detection gear material
Material with a property of being strongly attracted to a magnet,
5
Detection gear

The smaller the gap, the lower rotation speed can be detected. (ferromagnet) is good to use. If you have a choice, we recommend materials Output voltage Load resistance Oscilloscope
The gap should normally be set between 0.5 to 1 mm. such as S45C, SS400, SUS430, etc.
b) Detection gear tooth shape Gap

•Ono
15 50m
An involute gear is recommended. Sokki's Standard Detection Gear 6 M4 1
c) Gear size MP-001
4.5 100m
The module unit (M) is used. This value is used to determine the size of the The detection gear Ono Sokki provides is a
[Measurement conditions]
teeth. Modules with the same number of teeth can be meshed. module 1 involute gear with 60 teeth. 0.5 200m
Number of teeth : 60 Detection gear: M = 1, Z = 120 P/R
Pitch circle diameter
ø40

ø62

Module = –––––– Module :1 Load resistance: RL = 10 kΩ


Number of teeth
Material : SS400 (Chrome plated) Gap: G = 0.5 mm
ø9 H7

We recommend a module of greater than 1 and the width of teeth 4 mm. 0.2 0.5 1 5 10 50 100 KHz
Frequency

8 9
•MP-9100 •MP-911 2-Lock nuts (Dimensions of M3 Crimp
•MP-954 •MP-962
Rotation Detectors External Gear Type

Rotation Detectors External Gear Type


2-Lock nuts (Dimensions of width across flat 21) terminal
M16 x 1 width across flat 21) Connector (HS12RG-2) M16 X 1 2-Lock nuts (Dimensions of Connector
M8 X 0.5 width across flat 14) (BNC jack)

ø20
ø15
1:SIGNAL 4 2-Lock nuts (Dimensions of

ø2.5
2:COMMON M12 X 1 width across flat 17)

4 Connector
3
(BNC jack)

(24)
ø2.5

ø2.5

ø2
ø20

34 (29) ap5000

(24)
1

(16.2)
(20)
1 2
21 64
17 1 81 ap500
1 34 (23.5) 21 14 1 30 ap500
102 Signal cable (3C2VS 0.5m)
58.5 Signal cable (3C2V 0.5m)
49
Signal cable (3D2V 5m)

•MP-9120 •MP-930 •MP-992 •MP-9200


2-Lock nuts (Dimensions of 2-Lock nuts (Dimensions of
2-Lock nuts (Dimensions of M16 X 1 width across flat 21) M16x1 width across flat 21) Connector (HS12RG-2)
width across flat 21) Connector (HS12RG-2) Lock nut (Dimensions of
M16x1
M5 X 0.5 width across flat 7) FEP wire 1:SIGNAL
1:SIGNAL 2:COMMON
2:COMMON
4 Connector 4

ø20
ø15

ø2.5
ø2.5
4 (BNC jack) 2.5
ø2.5

ø1.5

ø20

(24)
(24)

1 2

(8)
ø20

(24)

1 2 A

1 34 (29) ap500 1 34 (23.5) S/N name plate 21


1 34 (23.5) 21 7 0.3
21 64 58.5
58.5 13 500
Signal cable
(3C2VS 0.5m)
A section detail (2/1)

•MP-935 •MP-936 •MP-963


2-Lock nuts (Dimensions of 2-Lock nuts (Dimensions of
M16 X 1 width across flat 21) 2-Lock nuts (Dimensions of
M16 X 1 width across flat 21)
M24 X 1 width across flat 36) Connector (12R2A)
5 CONNECTOR
1:SIGNAL
2:COMMON
Connector 4 Connector
ø20

4
ø15

ø20
ø2.5
ø2.5

(BNC jack) (BNC jack)


(24)
(24)

ø24
ø5

(41.6)
1 2

1 34 (29) ap1000 1 34 (29) ap1000

21 64 21 64
2 34 36

Signal cable Signal cable


(3DJ 1m) 68
(3DJ 1m)

•MP-940A •MP-950
2-Lock nuts (Dimensions of Connector
Lock nut (Dimensions of M12 X 1 width across flat 17) (BNC jack)
Connector
PF-1/4 width across flat 21) (HS12RG-2)
1:SIGNAL
2:COMMON
3
ø2.5
ø2.5
ø11

ø20

(20)
(24)

12

55 50 21 17 1 29 ap500

132 Signal cable (3C2V 0.5m)


50

10 11
Magnetoelectric Rotation Detector MP-981/9820 Electromagnetic Rotation Detector MP-800 series
General-purpose/high speed detection model Low-to-medium speed
This is a magnetic flux response type detector (the resistance value changes according to the magnetic flux) which internally has magnetic There are three models in the series, each with a different outer appearance: MP-810, MP-820 and MP-830.
resistance elements, permanent magnets, a direct current amplifier, and a voltage regulator. It can detect over a wide range of rotation speed from
ultra low speed to high, and outputs the results as a square waveform. •• There
Features
are three models in the series, differentiated by their outer
Three models are provided; General-purpose type (MP-981), high speed detection type (MP-9820) , and acid-resistance and waterproof type (AP-981).
Rotation Detectors External Gear Type

Rotation Detectors Built-in Gear Type


appearances.
•• Detection
Features
from nearly 0 r/min MP-810: base mount type
• Detection from low to high speeds MP-820: dual-shaft type
(1 to 100,000 r/min: MP-9820 [60-tooth gear]) MP-830: flange type
• Output as square waveform • Number of output pulses
• Compact, light weight, easy-to-mount
Model Number of Pulses (P/R)
•Detection
Specifications
method : detection using magnetic resistance elements
Module and detection distance
MP-981
MP-810F, 820F 300
MP-981 Detection range : MP-981··· 1 Hz to 20 kHz 3.0 • Rotation speed:
MP-810G, 820G, 830G 60, 120, 360
1 to 20,000 r/min (60 P/R)
MP-9820···1 Hz to 100 kHz • Temperature: 25 °C
Detection gear : ferromagnet (tooth width: at least 3 mm, 2.0 MP-810B, 820B, 830B 600
module: 0.5 to 3) Detection
Detection distance : see the graph at the right distance * Models other than MP-810B are made-to-order products.
Detectable range

•Rotating
M16×1 Connector (R04-R6M) Power requirement : 12 ±2 VDC (mm) 1.0

Lock nut Power consumption : approx. 40 mA (at 12 V, 25 ºC) 0.5 Specifications


Output waveform : square wave Lo: up to 0.5 V, Hi: 5±0.5 V speed range : 5 to 5,000 r/min
Output impedance : approx. 330 Ω
0
0.5 1 2 3 • MP-810 (Base mount type) Output waveform : approximate sine wave
Protective circuit : power source polarity, output short-circuit Module (M)
Output voltage : 0.5 Vp-p or more
ø22
21

protection MP-9820 Blind cover Cable clamp (STP-7)


Operating temperature : -10 to + 70 ºC Detection 2.5 • Rotation speed: (Exchangeable to (Suitable cable diameter: 3-6.5) DC resistance value : 770 ±30 Ω
Storage temperature : -20 to +80 ℃ distance 1 to 100,000 r/min (60 P/R) a cable clamp) 54 (Standard cable: 3D2V or P-2) 42

34 31 Withstand voltage : 250 VDC


(mm) 2.0 • Temperature: 25 °C
Terminal box
Inductance : 2 H typ. (at 1 kHz)
(24)
Vibration resistance (conduction) : 49 m/s2 each in X, Y, Z direction 1.5
(M3 Crimp terminal) Starting torque : 245 mN·m or less
65 (10) Color of lead wires
Shock resistance (non-conduction) :
Detectable range Blue: signal Moment of inertia : approx. 1.5 kg·cm2
490 m/s2 (three times each in the X, Y, Z 1.0
75
Red: common
Allowable shaft load : radial 147N, thrust 98N

82
directions)
0.5 Vibration resistance : 98 m/s2 (for two hours in each of the X, Y, and Z

ø15h7
Connection method : see P.34-35
Weight : approx. 80g (including the two nuts used 0 directions)

ø103
ø70
for fastening) 0.5 1 1.5 2 2.5 3
Accessory : two nuts for fastening, instruction manual ×1 Module (M) Shock resistance : 980 m/s2 (for three times in each of X, Y, and Z
14
directions)

55 -0.2
4-ø7 20

0
Operating temperature : -10 to 80 ºC
Magnetoelectric Rotation Detector AP-981 Weight : approx. 2 kg

8
Acid-resistant, waterproof type 48
110
28
50
6 45
30
Connection method : M3 crimp terminal (JIS C 2805 1.25-3) (When
using MP-081) See P.34 and P.35
130 97
The AP-981 is a waterproof model that complies with the JIS C 0920 Protective Class 7 (marking symbol: IPX7) requirements for the waterproof Cable outlet : cable clamp (complies with IP-68)
testing of electrical equipment and wiring materials. Surrounding magnetic field : up to 0.01 T Connector
Option : connector output (MP-081)
•• Can
12R2A
Features • MP-820 (Dual-shaft type)
be used for measurement in locations where nitric acid mist is in the
( (
Blind cover (Exchangeable to a cable clamp)
Connector plugs 12P2B
atmosphere, or in environments where the detector may be submerged. Cable clamp (STP-7) Terminal box For attachment to the
• Performs by non-contact detection 54
(Suitable cable diameter: 3-6.5)
(Standard cable: 3D2V or P-2) 42
(M3 Crimp terminal) terminal box (with covers)
Color of lead wires
• Detection from ultra low to high speeds (1 to 20,000 r/min [60-tooth Blue: signal
gear]) as square waves of the same amplitude Red: common <Related product: MP-837 (low impedance type)>
• Comes with a 1.9 m length acid-resistant cable attached • Number of output pulses •
Specifications
•Detection

82
Specifications Number of
(different from MP-810/820/830)

ø15h7
Model

ø15h7
method : detection using magnetic resistance elements and magnetic gears Pulses (P/R) Rotation speed : 50 to 2500 r/min
Detection range : 1 Hz to 20 kHz Output voltage : 1.5 Vp-p or more

ø103
ø70
Detection gear : ferromagnet (tooth width: at least 3 mm, module: 1 to 3) MP-837J 180
Detection distance : see the graph at the right Direct current resistance value

55 -0.2
14
MP-837K 240

0
Power requirement : 12 ±2 VDC Module and detection distance 4-ø7
20 20
: 50 ± 5 Ω
Ferromagnetic Positioning mark Ethylene propylene Power consumption : approx. 30 mA (at 12 V, 25 ºC) 2.0 MP-837L 300 Inductance : 0.12 H typ. (at 1 kHz)
Output waveform : square wave Lo; up to +0.5 V, Hi; +5 ±0.5 V • Rotating speed:
material rubber sheath
MP-837M 360

8
1 to 20,000 r/min (60 P/R)
(approx. 1.9 m) Output impedance : approx. 330 Ω 48 28 6 45 28
1.5 • Temperature: 25°C
Protective circuit : power source polarity, output 110 50 30 45 MP-837N 420
short-circuit protection Detection 130 125
distance
Operating temperature : (mm) 1.0 MP-837B 600
21

-10 to 70 ºC (on the condition that it is


within the atmosphere of IP-X7 {JIS C0920})
30 53 44 8max Storage temperature : -20 to 80 ºC 0.5 Detectable range • MP-830 (Flange type) <Related product: MP-837 (low impedance type)>
Withstand voltage : 250 VDC 0.3
ø44 82
36 Vibration resistance (conduction) : 0 Cable clamp (STP-7)
1.2 mm compound amplitude, 30 Hz 0 1 2 3 Blind cover
(Suitable cable diameter: 3-6.5) Blind cover Cable clamp (STP-7)
Module (M) (Exchangeable to
(for 1 hour in each of the X, Y, and Z directions) a cable clamp) (Standard cable: 3D2V or P-2) (Exchangeable to 54 (Suitable cable diameter: 3-6.5) 42
54 42
Shock resistance (non-conduction) : a cable clamp) (Standard cable: 3D2V or P-2)
ø23

ø24
ø27
28

Terminal box Terminal box


490 m/s2 (three times each in the X and Y directions) (M3 Crimp terminal)
(M3 Crimp terminal)
Outer surface material : polycarbonate Color of lead wires
Color of lead wires
Mounting Connection method : 1.9 m length directly attached cable (other end: open) Blue: signal
Blue: signal
flange 2-ø3.5 Weight : approx.130 g (including a signal cable) Red: common Red: common

82
82

Accessory : instruction manual ×1

ø15h7
ø15h7
8
ø118 ø11

ø70h7
ø70h7
Caution

ø103
(Example)

ø103

103
103
MP-981 and AP-981 have been designed for the purpose of detecting rotation speed. Please observe the following points when using 14 14
20
these detectors. Peak 4-ø7 20 4-n7
(1) A square wave with the same amplitude is output as the result of rotation measurement from low speed to high speed (1 to 20,000 Valley
(Example)
r/min: 60 gear teeth per a gear). However, it does not necessarily mean that the high level is appeared at the peak of the gear, the
low level at the valley. The starting points may not be the same when using several detectors for synchronous operation. CW 28 4
28 4
(2) The output pulse width may be different depending on the rotating direction of a detection gear (CW direction / CCW direction). 103 2 97 103
2
CCW 97

12 13
Optical Detector LG-9200 Photoelectric Rotation Detector FS-540/542/5500, FG-1300
Compact optical detector Optical Fiber Sensor/Fiber Optic Sensor Amplifier
LG-9200 is a reflective type photoelectric rotation detector
using an optical fiber at the tip. Designed to be resistant
•• Detection
Features
from nearly 0 r/min
Used with the combination of optical fiber sensor with an optical
multimeter. Can be detected up to 69 mm away from the target.
•• 10
Features
kHz of maximum response frequency. Supports detection of
against disturbance light using pulse modulation method for • Compact and easy-to-use type optical detector high-speed rotation.
the light source emitting modulation. • A unified structure of light source, receiver and amplifier (weight: • Red visible light adopted, easy to detect an object that is difficult to
Rotation Detectors Photoelectric Type

Rotation Detectors Photoelectric Type


approx. 150g) adjust optical axis position, such as a thin shaft.
• Light emitting diode is used for light emitting element • Detection with high sensitivity to be able to detect even minimal
• Easy positioning (visible light and operation indicator lighting function) changes in light amount and measures without reflective mark.
•Detection
Specifications
method : visible light photoelectric reflection method
(Unequal interval pulse which may be generated in detection without
reflective mark can be divided into 1 pulse.)
Detecting distance : recommended distance 20 to 40 mm • Selectable gain/trigger level adjustment depending on a use
(when using a dedicated reflective mark 12 mm square) application; manual adjustment using volume control button or auto
Maximum response speed adjustment using auto trigger.
: 40 m/s (converted to circumferential speed of rotating shaft) • Provides two measurement distance settings; normal range or
Response delay time : 0.6 ms (light receiver conversion time) or less adjacent range. Detectable from adjacency to 69 mm max.
Light source : light emitting diode (red visible light)
Light receiving element : phototransistor •FG-1300
Specifications
Fiber Optic Sensor Amplifier
Power requirement : 12 ±2 VDC • FG-1300 Detection method : detects amount of red visible light reflected
Current consumption : 60 mA or less (at 12 V)
light source; red visible light LED,
Output waveform : rectangular wave; Hi ... 5 ± 0.5 V, Lo ... 0.5 V or less light receiving element; phototransistor
(MAX 4)
Output impedance : 1 kΩ or less Panel mounting fixture (option)
Detection distance : 7 to 69 mm (FS-540/542), 2 to 50 mm (FS-5500)
Connection method : see P. 34, 35 Maximum response frequency : 10 kHz
Operating temperature : -10 to 60 °C Output signal : analog; detects reflected light and outputs signal waveform
Lock nut

72
M16x1 Storage temperature : -20 to 80 °C in proportion to the light amount.
Connector (R04 - R6M)
Conforming standard : CE marking output range: 0 to 10 V
ø2
2
Weight : approx. 150 g (including 2 nuts for fastening) pulse; outputs pulse signal after the waveform of

(4)
Rubber foot
(19) (12) reflected light is shaped and converted to square
20.7

144 180
Accessory : reflective mark (12 mm square, 25 sheets) × 1,
21

wave.
mounting nut × 2, instruction manual × 1
ø6h7

output voltage range; Lo level 0.5 V or less


(24) 10 34 63 Hi level 4.5 V or more
• Measurement range of the LG-9200

+0.5
Load resistance : 10 kΩ or more (analog, pulse)

68 -0
(21)
107 40mm Function : gain; measurement distance can be adjusted by control
Distance from a shaft center L (mm)

117 100 Setup knob or selection SW


distance Threshold level; can be adjusted manually/automatically by
(150) 138 +0.5
-0
80
L Rear view
control knob or selection SW.
Panel cut dimension
12×12 mm 1 piece Frequency dividing; Selectable from 1 to 10 by the
60
changeover switch. (Set within the
40
range of 1 to 10 input pulses)
• FS-540/542 Peak hold time constant; selectable from 1 s/10 s
20 Display : for checking sensitivity; LED bar chart type monitor
others; displays the status by LED indicator
Optical fiber ø4
0 Connector Connecting method : see P.34-35

ø10
0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 22000 M8x1
Power supply : 100 to 240 VAC (50 Hz/60 Hz)
Rotation speed (r/min) Operating temperature : 0 to 40 ºC
Photoelectric Rotation Detector LG-930 50 Operating humidity : 5 to 80 % RH (with no condensation)
L 75 Conforming standard : compliant with CE marking
Weight : approx. 1 kg
Compact model designed for the long-distance detection of visible light Accessory : power cable (AC 100 V)×1, instruction manual×1, rubber foot
(4 pieces)×1 set
• FS-5500
The LG-930 is a compact reflective type photoelectric rotation
detector that can be positioned up to 200 mm away from the
•• Can
Features
be positioned at a distance of up to 200 mm away from the 500
M4
(Effective screw length 13)
Option : stand (FG-0131), panel mounting fixture (FG-0132)
• Specifications (FS-540/542/5500)
Plug
target object. measurement object. (0.5) (3) Caulking
2-M4 (lock nut) (OFø2)
FS-540 FS-542 FS-5500

(ø4.6)
(ø6, width 3) (OFø2)

(2)
• The compact design enables it to be mounted in small spaces.

FS-5500 L012
Detection type Optical fiber reflection type

6
Moreover, an L-shaped mounting fixture is provided. 15 Tip: SUS Emitting port diameter at the tip of fiber ø 4 mm ø 2 mm
SUS flexible tube
• Visible light is used for easy positioning, and the built-in operating 2- (OFø1.4) (40) L=2000±100 22
Fiber length (L) 1m 2m
indicator light enables easy setup. (Note1) L can be changed (custom-made).
Mounting nut M8 M4
• The pulse lighting method ensures that the LG-930 is virtually Operating temperature range -10 to 250 ºc -40 to 250 ºc
unaffected by ambient light. * Reflective mark (12 mm square 25 sheets) 1 sheet included.

•Detection
Specifications •Application * Fiber cable can be extended.

method : visible light photoelectric reflection method


Detection distance : 70 to 200 mm (when using dedicated reflective mark • Rotation measurement using photoelectric type • Measurement of motor, fan, engine
of 12mm square) non-contact rotation detector Rotation target Rotation Measurement
Object detected : reflective mark Affix a dedicated 12 mm square reflective mark to the
Maximum response speed : 25 m/s (when using the dedicated 12-mm-square shaft of the motor etc. and measure the rotation speed
reflective mark, affixing interval 48 mm) without contact by an optical fiber sensor. You can
Response delay time : 0.5 ms (light receiver conversion time) or less measure the target from a distance 200 mm max. TM-3100 series Tachometer

Light source : light emitting diode (red visible light) (measurement distance from a detector to reflective Motor
marks: 70 to 200 mm).
Light receiving element : phototransistor TM-3110
FV-1500 FV converter
Tachometer
Power requirement : 12 ± 2 VDC
24

Current consumption : 85 mA or less (at 12 V) FFT/tracking measurement


22

Output waveform : rectangular wave; Hi: + 5±0.5 V, Lo: 0.5 V or less (on
8

2-R2.1 2.1
2-R condition that a load resistance is at 100 kΩ at least.)
6 8 29 Fan
5.5

49 Output impedance : 1 kΩ or less Reflective mark


23
76.5 Cable cord (ø5): 4.9 m Operating temperature : -10 to + 60 ºC
Storage temperature : -20 to +80 ºC FG-1300 CF series FFT analyzer
Fiber optic sensor amplifier
Input/output connectors : directly attached cable with the other end open AX-2050N FS-540
29

12.5

Power cable
(38)

Cable length : 4.9 m LG-930 Optical fiber sensor


Photoelectric type
Weight : approx. 300 g rotation detector Engine DS series Data station
2

2-M4
28.5 35 Accessory : reflective mark (12 mm square × 25 sheets)× 1 Motor
mounting fixture × 1, screw× 2, instruction manual× 1
* For more details of FS-540/542/5500, FG-1300, please refer to the Product Brochure page of our website.
14 15
Rotary Encoder SP-405ZA
Ultra-compact type
•Application •• Economic
Features
type designed for OEM needs
• Presence or absence detection of small parts • Product inspection of motors • ø 38 outer diameter; ultra-compact, light weight model weighing only
100 g
Rotation Detectors Application

Rotation Detectors Rotary Encoder


FS-5500 can project to a small part at a pinpoint with φ 2 mm of • 2-phase square wave + zero mark signal output
light emission. Alarm
Presence or absence of a small part flowing on a production line
Personal computer • Choice from 13 pulse output types
Large indicator
can easily be detected by measuring reflected light amount and
judging the level of it by the threshold function.
Comparator
output •Number
Specifications
of output pulses : 40, 50, 60, 100, 200, 250, 300, 360, 400,
TM-5100
Multifunction digital tachometer 500, 600, 800, 900 P/R
RS-232C 
Output waveform : 2-phase square waveform+ zero mark
BCD output (parameter setting) (timing is optional)
UPPER SETTING
LOWER SETTING
Output voltage : Hi···Power supply voltage -20 % or more
Photoelectric type
rotation detector Comparator output Lo···0.5 V or less
Pass/fail judgment
FS-5500 (LG-9200/930) Output method : collector
FG-1300 load resistance; 10 k Ω or more
*Open collector: 30 VDC, 35 mA or less
6-M3Depth6 17 30 Adjacent error : ±1/15 P
Red LED light
90°
12 5 Power requirement : 5 to 12 VDC ± 10 %, 50 mA
* 24 VDC is also available only when the open collector is


12
PLC selected (option).
ø28
Response frequency : 100 kHz
Connection method : directly attached cable (1 m)

ø20h8
ø4h6
ø38
90°
(other end: open)
Maximum rotation speed : 6000 r/min
• Non-contact measurement of rotation speed on small rotating shaft of 5 mm diameter 90°
Allowable shaft load : radial; 25 N thrust; 15 N
• If there is unevenness on the rotating shaft or a black line, a periodic change occurs in the amount of reflected light of the optical fiber 120° Starting torque : 2mN·m
detector. Based on this periodic change, the rotation speed of the shaft is measured. 45° Moment of inertia : 6g·cm2
The following example shows how to measure a thin rotation axis that is difficult to affix a reflective mark and a fan motor from that reflect
ø4.2 shielded cable 5.5 Operating temperature : -10 to 70 ºC
light does not return straight. L=1000 Storage temperature : -20 to 80 ºC
• Applicable diameter of rotating shaft: 5 mm or more Withstand humidity : 90 % (with no condensation)
• Detection distance: approx. 2 to 50 mm Protection class : IP 40
• OK, LOWER, UPPER judgment on the production line available (comparator output from the FV-1500) Vibration resistance : 98 m/s2 (for 2 hours each in 3 directions)
Shock resistance : 980 m/s2 (for 3 times each in 3 directions,
shaft; 98 m/s2)
• Output circuit Collector output Weight : approx. 0.1 kg
5 to 12 V
MX-100 series
Signal cable Analog output
2.2 k Ω

FV-1500 Output
FG-1300 High-speed F/V converter
Fiber optic sensor amplifier
Recorder

Comparator Common
Fiber cable output

FS-5500
Optical fiber sensor

Lower OK Upper
Approx. 2 to 50 mm
Upper/lower limit judgment output
DC motor
Customer preparation

* We have extensive variety of rotary encoders. Detailed brochures are prepared separately, so please visit out website.
16 17
Rotation Display Unit
Digital Tachometer TM-3100 series
DIN standard size (96×48 mm) / for general-purpose
TM-3110 Display only Depending on the application, you can choose the
suitable model from four types: display only type,
Sudden deceleration follow-up function :
When the input pulse suddenly
decreases and not being input after
•Features BCD output type, analog output type, or comparator approx.1 s or more, the display value
automatically decreases and becomes 0
• With BCD output of 6-digit display
• Basic model for measurement and display
output type. after approx.11 seconds.
Moving average function :
• Wide measurement range from low to high speed (0.1 Hz to 100 kHz)
• The fluorescent display tube greatly improves stability and readability.
•Various functions (common to all models) Selectable from OFF (shipping time), 2, 4,
• Display in various units is available by coefficient setting. 8, 16, 32, 64, 128
• Compatible with our various detectors. • Condition memory function * Analog output of TM-3130/0330 performs moving
average of the calculation value every 10 ms and
• Sudden deceleration follow-up function enables to follow up and outputs it.
display even at the time of a sudden stop. Peak hold function : This function holds the peak values
• Calculation of the maximum value, minimum value, average value for (maximum value, minimum value,
each section average value) from measurement start
• Moving average function to stop.
Rotation Display Units General-purpose

Rotation Display Units General-purpose


• With auto zero function Memory
• Pulse output Panel condition memory :
• World wide power supply (100 to 240 VAC) Memorizes 4 kinds of measurement

TM-3120 BCD output •Common specifications conditions (The setup conditions can be
stored and recalled.)
Input Power supply for detection
Input terminal : M3, free terminal screw
•Features Outputs data and print command
within a minimum of 50 ms after
Input impedance : 10 kΩ or more
Input format : voltage or non-voltage
Output voltage : 12 VDC ± 10%
Maximum output current : 100 mA
• With BCD output of 6-digit display receiving the request pulse. General specifications
• Open collector output for direct Output signal Input amplification : AC or DC Rated power : 100 to 240 VAC (50 Hz/ 60Hz) 30 VA max.
connection with a PLC BCD output Compatible detectors: TM-3100 ; 11 to 19 VA
• Output mode is selectable from normal or Output form : 6-digit parallel output electromagnetic type/magneto-electric TM-3120 ; 13 to 21 VA
request. Output format : open collector type/photoelectric type/rotary encoder/ TM-3130 ; 16 to 25 VA
Sync current : max. 32 mA proximity switch TM-3140 ; 12 to 21 VA
• Output can be optionally changed to
Output withstand voltage : max. 24 V [Input amplification format specification] * When all the cards (analog output, BCD output,
voltage output. Output logic : positive logic •AC amplifier comparator output) are installed: 20 to 30 VA

•Mode
Specifications Data refresh time : 100 ms or less
Input signal
Signal waveform : sine or square wave
Signal voltage : sine wave; 0.2 to 45 Vms
Withstand voltage : 1500 VAC (1 min)
Insulation resistance : 10 MΩ or more (at 500 VDC mega)
Request signal square wave; 0.6 V to 63 Vp-p Operating temperature : 0 to 50 ºC
Normal mode : continuously outputs the print Input logic : negative logic (pulse width: Storage temperature : -10 to 60 ºC
BCD mode setting screen command every approx.100 ms. Signal frequency : 1 Hz to 100 k Hz
10 µs or more) •DC amplifier Operating humidity : 30 to 80% RH (with no condensation)
Request mode : Data is output for each request Operating edge : falling edge Signal waveform : rectangular waveform having a pulse Storage humidity : 30 to 85% RH (with no condensation)
pulse. Input voltage : TTL
width at 5 µs or more Outer dimensions : 96 (W)×48 (H)×148 (D) mm
TM-3130 Analog output
Gate function : start, stop, reset Weight : approx.310 g
Signal voltage : Hi level; +4 to +30 V, Lo level; -1 to +1 V
Signal frequency : 0.1 Hz to 100 kHz Applicable standards
Low pass filter : OFF/20 kHz switchable CE marking : Low voltage Directive
•Features Output current range :
selectable from 4 to 20 mA, Output <Pulse output> EN61010-1:2001 (2nd)
Overvoltage category Ⅱ/pollution degree 2
• Output pulse can be switched between 0 to 16 mA Output voltage : Hi level; 4.5 V or more
voltage and current. Load resistance Lo level; 0.5 V or less EMC Directive
• Improves update time (10 ms) by using Voltage output : 100 kΩ or more Output logic : negative EN61326-1:2006 Embedded board type
D/A conversion method. Output current : 500 Ω or less Load resistance : 100 kΩ or more Accessory
Linearity : ± 0.3 %/F.S. Output terminal : M3 free terminal screw Instruction manual × 1 set : (spec edition, basic operation
•Output
Specifications
signal (voltage or current selectable)
Analog output adjustment
Voltage output : ± 5 %/F.S. or more
Display
Display unit : fluorescent display tube (selectable from panel mounting fixture ×1 set
manual),

Output method : 12bit D/A conversion Current output : ± 3 %/F.S. or more three-stage brightness, 6-digit display) condenser×1
*Resolution decreases depending Zero drift : ± 0.05%/F.S./ºC Display refresh time : selectable from 0.2 s (factory setting), Option
on the set value. Span drift : ± 0.05 %/F.S./ºC 0.4s, 0.5s, 0.6s, 0.8s, 1.0 to 10s (in 1.0s step). power cable for 100 V 3m (AX-2050N)
Output voltage range : Output refresh time : selectable from followings; Display unit : select from the table below
Analog output setting screen Selected from 0 to 10 V, 0 to 10, 20, 50, 100, 200, 500 ms,
Calculation Unit
Option Board
5 V, 1 to 5 V 1s Rotation speed r/s, r/min, r/h
Circumferential speed mm/s, m/s, mm/min, m/min
mm/s, m/s, mm/min, m/min,
Moving speed

TM-3140 Comparator output


km/min, mm/h, m/h, km/h
Period s, min
No. of times (1/s) 1/s, 1/min, 1/h

•UPPER
Frequency Hz, kHz
Specifications Comparator hysteresis :
Sets hysteresis in judgment
Flow rate ml/s, ml/min, ml/h, l/s, l/min, l/h
Transit time s, min
setup : 6-digit numeric input value at comparator return. Option EU/s, EU/min, EU/h
(The relay is ON when UPPER Holding mode : Even if the rotation speed
≦ displayed value) returns to within the setting Character height : 10 mm
LOWER setup : 6-digit numeric input range, it holds the state. Number of decimal places to display :
(The relay is ON when LOWER Shot output function : Select from OFF (none), 1st, 2nd, 3rd
> displayed value.) Holds comparator output SIG indicator : flashes synchronously with the input pulse
OK setup : The relay is ON when UPPER
or LOWER is OFF.
time for a certain time. OFF
(shipping time), 10 to 2000 ms,
Error display : backup memory error, board error, input
frequency error, display digit number •Features
ERROR setup : The relay is ON when any set in increments of 10 ms. error, memory full error, setting value error • Function can be added by option board.
ERROR other than RS COMP delay function : Calculation display : rotation speed, circumferential speed, • By addition of TM-0350, further advanced measurement such as
communication error occurs. When the set value exceeds moving speed, period, number of times rotation fluctuation rate, section data can be performed besides
Output format : 1-make contact output the setting time continuously RS-232C communication.
(1/s), frequency, flow rate, transit time
•Option board list
Three outputs : for the set time or more, the
COMP1, COMP2, and COMP3
Measurement method : period calculation method
comparator operates. Measurement time : 10 ms + 1 period time
•Features
• Up to 3 types of judgment levels for upper and Measurement mode
Either of UPPER, LOWER, OK,
or ERROR can be set to.
0 to 1000 ms, set in increments
of 50 ms.
Measurement accuracy :
Displayed value × (± 0. 01%) within ± 1 count
TM-0301: DC power supply card
TM-0321: BCD output card, voltage output
Reset function : Resets in comparator holding * The displayed value here indicates the count value TM-0322: BCD output card, open collector output
lower range Natural restoration mode : mode. excluding the decimal point. TM-0330: Analog output card
• High speed response with output update time of Automatic restoration when the Maximum contact capacity : Auto zero function : This function sets the displayed value to 0 if TM-0340: Comparator output card
approx.10 ms rotation speed returns to within 30 VDC V/1A, 250 VAC/1 A there is no pulse input during the set time. TM-0350: RS-232C card
• Various output functions the set range Output format : terminal block Select from OFF (11 s), 0.5 s, 1.0 s, 2.0 s, 3.0 s, * Installation of optional boards after ordering a main body requires separate fee.
Output refresh time : approx.10 ms 4.0 s, 5.0 s, 6.0 s, 7.0 s, 8.0 s, 9.0 s, 10.0 s. Please contact your nearest distributor or Ono Sokki sales office nearby.

18 19
Digital Tachometer TM-5100
Multifunction Digital Tachometer
•Specifications
Applicable detector : MP series electromagnetic type / magneto
electric type rotation detector, LG series
Rear side panel connector terminal screw: M3 Outer dimensions TM-3100 series photoelectric type rotation detector, RP series
rotary encoder, roller encoder etc.
91 Number of input ch :2
• TM-3110 • TM-3120 99 or more Input amplifier type : AC/DC (switching type)
Measurement method : periodic calculation method, gate calculation
method (switching type)
Measurement time : 0.2 s + 1 period time (by periodic calculation

85 or more
44.6

44.6
+0.8
method)
92 0
Coefficient setting range : 0.0001 to 99.9999
2ch calculation function : difference <B-A>, ratio <(B/A) × 100>

+0.8
change rate <(B-A/A) × 100>

0
45
91 91
Rotation direction measurement function :
Panel cut dimensions The direction of rotation is indicated by polarity
Rotation Display Units General-purpose

Rotation Display Units Multifunction Type


display when 2-phase rotary encoder is used.
Main display section : green 7-segment LED (character height: 14 mm)
• TM-3130 • TM-3140 11.3 122 14 display range··· 0 ± 999999 (0. 00 to 9999. 99 %)
PANEL THICK MAX 5 Sub display section (parameter setting display section) :
96
(11.5)
LCD module
144 180
display character number··· 16 characters × 2 steps
44.6

44.6

Digital Tachometer TM-3100 POWER A B C D


AC
1 100-240 V

COMP
1
BCD EXTERNAL
1 RXD
ANALOG
1 V/I
INPUT
1 +12 V Digital Tachometer TM-5100 Signal input section : input impedance··· 10 kΩ or more (at 100 kHz)

RS-232C
1 36 2 TXD
2 2 3 CTS 2 COM2 2 COM1

AC amplification section : signal waveform··· sine wave or square wave


50/60 Hz 4 RTS UPPER
3 N.C.

48
3 MAX 30 VA 3 2 5 COM2 3 SIG
N.C.
GOOD
6
4 7 START 4 N.C. 4 COM1
5 STOP 5 N.C. 5 P -OUT

GATE
8
3 9 RESET LOWER

signal voltage range···sine wave; 0.2 to + 45 Vrms


6 1 10 COM 2 6 N.C. 6 COM2

72
SIG START STOP RESET COND ONO SOKKI CO., LTD.
MADE IN JAPAN TM-3100 RESET MENU
91 91
square wave; 0.6 to 63 VP-P
MENU SET/NEXT SELECT
COMP SET
ON/OFF NEXT

(10)
(54)
MAX4
signal frequency range··· 1 Hz to 100 kHz
DC amplification section : signal waveform··· rectangular wave pulse of 4 or

(9.5)
more width
signal voltage range··· Hi; 4 to 30 V, Lo; -1 to 1 V
•TM-3100 series output enlarged view Comparator function
signal frequency range··· 0.0006 Hz to 100 kHz
: number of setting stages··· 2
BCD-OUT POWER

setting range··· 0 ± 999999


T1 EXT-IN

TM-3110 (display only) : POWER + D (INPUT) POWER A B C D T2 SIG-IN

+0.5
output item··· UPPER /GOOD/ LOWER
100−240V∼
50/60

68 0
RS-232C

TM-3120 (BCD output) : POWER + D (INPUT) + B (O.C.)


45VA MAX
FUSE 2A T

AC COMP BCD EXTERNAL ANALOG INPUT


output format··· semiconductor relay makeup
T3 OUTPUT

TM-3130 (analog output) : POWER + D (INPUT) + C (ANALOG)


TM-3140 (comparator output) : POWER + D (INPUT) + A (COMP) 1 100-240 V 1 1 RXD
1 V/I 1 +12 V contact (30 VDC, 0.1 A)

RS-232C
1 36 2 TXD
138 +0.5
2 2 CTS 2 COM2 2 COM1 Analog output : conversion method··· 12 bit, D / A method
0
3
*By addition of board, function can be added. 50/60 Hz 4 RTS
3 MAX 30 VA 3 2 5 COM2 3 N.C. 3 SIG Rear view Panel cut dimension voltage range··· 0 to ± 10 V / F.S.
N.C.
4 6
7 START 4 N.C. 4 COM1 (F.S. = Full Scale; can be set arbitrarily.)
5 3
8
9
STOP
RESET
GATE 5 N.C. 5 P -OUT BCD output : positive/negative logic (switchable),
6 1 10 COM 2 6 N.C. 6 COM2 6-digit parallel
output format··· open collector
ONO SOKKI CO., LTD.
MADE IN JAPAN •Features RS-232 communication
Supply power for sensor
: baud rate··· 2400, 4800, 9600 bps
: 5 VDC ± 0. 25 V (max 150 mA) with the total value
• Rotation measurement over a wide range from low to
of A ch and B ch
high speed (input frequency: 0.6 mHz to 100 kHz)
12 VDC ± 0. 6 V (max 150 mA) for each channel of
• Two sensors are used to display the rotation direction A ch and B ch
•Application with phase difference pulse input
• Converts to arbitrary physical amount that is
Power supply voltage : 100 to 240 VAC (50/60 Hz)
Power consumption : 45 VA or less
• Measure the rotation speed of the shaft to display, • Measure, display, and record the shaft rotation speed proportional to rotation speed by each channel Operating temperature : 0 to 40 °C
output the measurement result to the printer or and its fluctuation independent coefficient correction function Storage temperature : -10 to 55 °C
• Built-in comparator function of upper and lower range Operating (storage) humidity : max. 95 % (with no condensation)
sequencer, also output to the comparator. A rotation detector is attached to a gear on a rotating main shaft Weight : approx.1.5 kg
In the following application, motor rotation is measured using such as a stirrer, a mixer, a centrifugal separator, and the rotation in two stages
Withstand voltage : 1500 VAC (between power supply and GND, 1 min)
MP-981 magnetoelectric rotation detector, TM-3210 digital speed of the shaft is measured and displayed. By using the • 2ch calculation function displays rotation speed
Insulation resistance : 10 MΩ or more (500 VDC mega)
tachometer, and its optional functions. analog output, you can record it on a recorder and check the difference/rotation speed ratio/rolling
The rotation speed of a motor shaft is amplified by gears, and the Accessory : power cable×1, panel mounting fixture× 1,
rotation change. reduction/draw/rotation change rate/direction of
rotation speed (r/min) and speed (m/min) of the rotator are calculated. foot stand×1, rubber foot × 1, terminal socket (5
The rotation speed of the shaft is measured by MP-981
rotation. pins) × 1, (10 pins) × 2, unit seal × 1, instruction
MX-7000 series
magnetoelectric rotation detector, the calculation is made by Signal cable TM-3130 • BCD, analog comparator, RS-232C are provided as manual × 1
Rotation display unit
TM-3120 digital tachometer. Adding an option expands the range MP-001
Recorder standard for output function. Option : BCD cable 3 m (AA-8107)
of output devices to. Detection gear • Easy-to-install DIN standard size (144 × 72 mm) RS-232C cable 2m (AX-5022)
BCD output function (TM-0321, TM-0322): Printing, loading to the • Two Displays: a main display section that indicates
MP-981
PLC Electromagnetic Analog
coefficient value and a sub display (2 steps) that
output
Comparator function (TM-0340): Alarm can also be set. detector
Customer preparation indicates set items (comparator setting
TM-3120 + TM-0340
Rotation display unit + comparator output card
RQ-1410
Digital printer value/coefficient value/ 2ch measurement values).
BCD cable
MX-7000 series (HDRA-E36MA + AX-2050N
Signal cable to 57-30360) Power cable

MP-981 Stirring machine


Electromagnetic type Sequencer
rotation detector
AX-2050N
Power cable
A Number of
gears=40 Alarm

MP-001 B Number of Comparator


Detection gear gears=80 output

Customer preparation

20 21
FFT Tachometer FT-2500
Advanced Tachometer
The FT-2500 is a tachometer that performs frequency analysis by FFT calculation processing and measures rotation speed. Even when the rotating • FT-2500 advanced tachometer
shaft is not accessible, it can measure from sound, vibration, etc. and supports various types of rotating objects such as steady rotation of a motor,
acceleration / deceleration rotation of an engine.
144 180 (16)
Measurement accuracy : ±2 x rotating speed resolution (r/min)
±1 count (in both modes)
*Measurement accuracy depends on frequency
range.
Rotation direction judgment : available when using FT-0501
Averaging process : moving average processing

72
Number of averaging times : OFF, 2, 4, 8, 16
Filter function : Can be set arbitrarily
Display section
Display update time : 0.5 ± 0.2 second
Measurement display range : 0 to 999,999 r/min (0 to 10,000 Hz)

(9.5)
Output section
MAX4
Analog output : 0 to 10 V/0 to F.S. to the displayed value Mounting thickness
Output update time : constant; 500 ms or less (steady rotation
Rotation Display Units Advanced Type

Rotation Display Units Advanced Type


measurement mode)
active; 250 ms or less (rotation
acceleration/deceleration
mode)
•Features Sensor signal monitoring output :

68 −0 
+0.5
• No need for reflective mark and special machining to install a sensor signal output for monitoring Panel cut dimensions

detector (The output is selectable from analog or


monitor output.)
• Enables rotation measurement using sound and vibration Comparator output : judgment of upper/lower limit, rotation
easily. Machining of the rotating shaft is not required. direction judgment, OK judgment +0.5
138 −0 
• Supports rotation speed change and acceleration/deceleration. output method; semiconductor relay
(when selecting rotation acceleration/deceleration measurement Signal content : pulse of frequency corresponding to the
mode) power spectrum extracted by FFT
• Rotation direction judgment function (FT-0501) calculation
Output voltage : Lo···1 V or less, Hi···4.5 V or more
• Easy-to-read indication by fluorescent display tube (without load) • FT-0501 Rotation detector for DC motor • FT-0801 Cigar lighter socket sensor
• With analog output, pulse output External interface : RS-232C, external command input
•Specifications Condition memory
connector
: saves 3 kinds of setting conditions
Input section General specifications Cable length 2 m
Applicable sensors: FT-0501/0801, IP-292/296/3000A/3100, Power requirement : 100 to 240 VAC (50/60 Hz)
VP-202/1220, OM-1200/1500, Constant Applicable standard : CE marking
Current Line Drive sensors, Weight : approx.1.2 Kg 20

24±1
(microphones, accelerometers) and so on.

ø20
Power consumption : 22 to 32 VA
Measurement section Operating temperature : 0 to +40 °C
Measurement mode Storage temperature : -10 to +55 °C

ø22.3
1. Steady rotation measurement mode Operating (storage) humidity : 20 to 80 % RH (with no condensation) 7 (11.5)
Frequency range : 500 Hz, 2 kHz, 10 kHz (C02) BNC plug
Withstand voltage : 1500 VAC (between power source and 69±0.5
Rotation speed resolution : frequency range (Hz) ÷ 12800 × 60÷set FG, 1 min) R03-PB6M Signal cable 3m 11
23
pulse count Insulation resistance : 5 MΩ or more (between power source
2. Rotation acceleration/deceleration measurement mode and FG, 500 VDC)
Frequency range : 250 Hz, 500 Hz, 2 kHz Accessory : power cable, panel mounting fixture,
Rotation speed resolution : frequency range (Hz) ÷ 6400 × 60 ÷set stand foot, rubber foot, connector,
pulse count instruction manual ··· 1 pc. for each
Option : analog output cable 1.5 m (FT-0100)
There may be some cases that the FT-2500 cannot measure depending on the {R03PB3M(FT side) to BNC245(BNC)} Sensor specification FT-0501 FT-0801
type of engine and motor, or the measurement range may change.
Pulse output cable 1.5 m (FT-0110) Measurement target DC motor etc. (commutator type) Automobile, construction machine
Please confirm with the demonstration machine before order. Please contact {D-SUB15PIN(FT side) to BNC245(BNC)}
the nearest distributors or our sales office for demonstration machines. Detection method Leakage magnetic flux detection Voltage noise
RS-232C cable 2 m (AX-5022)
Major specifications Direct attached signal cable 3m Plug in cigarette lighter socket.

•Application With tip connector (R03-PB6M)


*It is necessary to set the number of poles of the motor.
Cable length 2m
With tip connector (C02) (BNC)
• Example of engine rotation speed measurement using • Measurement example of rotation speed of DC motor Operating temperature range -10 to 60 ºC 0 to 40 ºC
cigar lighter socket sensor incorporated in home electric appliances
Connect to power outlet installed in an automobile or a construction In this application, we measure the rotation of the electric toothbrush,
machine. The ignition noise of the voltage output from the power outlet is which DC motor rotation is converted into brush vibration inside.
detected and the rotation speed of engine can be measured by the The FT-2500 measures the rotation speed by detecting the magnetic flux
FT-2500. Compatible with battery 12 and 24 VDC. leakage from the DC motor incorporated in the toothbrush.
・Detects pulsation of magnetic flux leakage proportional to the number of
Advanced tachometer poles of the DC motor from the completed product.
・With upper / lower limit comparator output for OK, LOWER, UPPER
FT-2500
judgment on production line.
・Data management with RS-232C
・System can be upgraded at low price.
Advanced tachometer
FT-2500

Rotation detector
for DC motor
FT-0501 RS-232C

Electric
toothbrush Upper/lower limit judgment output PC (data management)
FT-0801 (comparator function)
Cigar lighter socket sensor

* Please contact us for more detail brochure of the FT-2500.


22 23
Handheld Tachometer
Handheld Tachometer HT-5500
Handheld Tachometer FT-7200 Handheld Digital Tachometer
Advanced Handheld Tachometer HT-5500 Contact/non-contact type · multifunction type
FT-7200 FFT calculation method Extensive measurement from 6.0 r/min (low speed rotation) to 99999 r/min (high speed rotation).

Rotation upper limit warning function :


The FT-7200 is a handy type tachometer that performs frequency analysis by FFT calculation processing and measures rotation speed.
When the rotation speed exceeds a
Can measure a wide range from steady motor rotation to acceleration/deceleration of engine rotation. preset upper limit value, upper limit
warning (↑mark) is displayed.
Display section Circumferential speed calculation function :
LCD display : 5 digits, LCD 7 segments, with backlight [non-contact type] circumferential speed
(character height 10.2 mm) is calculated with the preset diameter
Display update time : 0.5 ± 0.2 s Rotation contact tip (mm) and the measured rotation speed.
Display resolution : 1 r/min (KS-300) [contact type] circumferential ring
Measurement mode + KS-100/200 is used.
CNS (Constant) : Used when the fluctuation of the Contact adapter
Integration count function : Performs integration pulse counting of
rotation speed of the object to be (HT-0502)
input signal
measured is small (when measuring *Note: The display is updated every display update time.
the rated rotation speed, etc.) Period measurement function :
ACT (Active) : Used when the rotation speed of the Measures the period of input pulse
object to be measured accelerates or (however, average value of input pulse if
decelerates. (However, when it changes it is 1 second or more)
suddenly, it may not measure correctly.) Rotation speed : non-contact type (with reflective mark),
Output section contact type (using KS-300)
[ANALOG] analog output (switch to analog output for monitor) Output section [analog output]
Output content
Voltage range
: Outputs to the rotation speed display value
: 0 to 1 V / 0 to F.S. (F.S. is arbitrarily set.)
•Features Output voltage : 0 to 1 V / 0 to F.S. (Full scale is arbitrarily
set.)
• Memory function: up to 20 data of memory can be recorded.
•Features Conversion method
Linearity
: 10 bit D/A conversion method
: ± 1% of F.S. • Both contact and non-contact measurement, line speed
Conversion method
Linearity
: 10 bit D/A conversion method
: ± 1% F.S.
• Enables rotation measurement easily using sound and Output update time : within 250 ms measurement is available with non-contact method. Output update time : 50 ms + input pulse within 1 period time
vibration. Machining of the rotating shaft is not required. Temperature stability : ± 0.05% of F.S. / °C (ZERO & SPAN) • Both analog and pulse outputs provided as standard. Used Temperature stability : ± 0.05 %/ F.S. /°C (span & zero)
Handheld Tachometer Advanced Handheld Tachometer

Handheld Tachometer Handheld Digital Tachometer


• Supports rotation speed change and acceleration/deceleration. Setting error : ± 0.5% of F.S. (factory setting for recording rotation speed and as rotation synchronization Full scale setting error : ± 0.5 % /F.S.
adjustment error, ZERO & SPAN) Load resistance : 100 kΩ or more
• Efficient for measuring engine rotation speed of completed Load resistance : 100 kΩ or more
signals. Output section [pulse output]
vehicles etc. Output connector : mini jack (ø 2.5) • Peak hold function installed: maximum value and minimum Output voltage : Hi level··· 4.5 V or more (when detecting
• Various sensors can be used. [ANALOG] analog output for monitor (switch to analog output) value during measurement can be displayed. with reflective mark)
• Both analog and pulse outputs provided as standard. Used Output content : analog output for monitoring after • Large LCD with backlight. Lo level··· 0.5 V or less
for recording rotation speed and as rotation synchronization waveform shaping of sensor pulse • Tripod, stand jig (option) mounting: can be fixed to a tripod Output logic : positive logic
Load resistance : 100 kΩ or more etc. for continuous measurement. Load resistance : 100 kΩ or more
signals. Output connector : mini jack (ø 2.5/commonly used with General specifications
• Large LCD with backlight.
• With averaging processing function. [PULSE] output
ANALOG output) •Specifications Power : AAA battery x4 or dedicated AC adapter
(PB-7090: sold separately)
Detection method : red visible light photoelectric reflection
•Specifications Signal content : Outputs frequency pulse of the power
spectrum extracted by FFT processing
method, contact method (attaching
contact adapter)
Battery life : approx. 32 hours (when the backlight is
OFF)
Measurement section Output voltage : Lo··· 0.5 V or less, Hi··· 4.5 V or more (no load) approx. 8 hours (when the backlight is ON)
Measurement object : DC motor, compressor, engine or Detection distance : 20 to 300 mm
Output frequency range : 3.75 Hz to 2 kHz, equivalent to display Display section : LCD, 5 digits, with backlight (When alkaline dry battery used, at 20 °C)
general rotating body rotation speed × number of set pulses Low battery display : When the battery voltage becomes
Calculation method : FFT calculation method (character height: 10.2 mm)
per rotation (P/R) Measurement time : 1 s+ input pulse, within 1 period time approx. 4.5 V or less, a LOW mark is
Measurement time : within 250 ms Output update time : steady rotation mode (Constant); within displayed.
Input frequency range : 3.75 Hz to 2 kHz (3 ranges switching) (However, when it is 60 r/min or less, it
500 ms is about twice the period time) Operating temperature : 0 to 40 °C
Measurement unit : r/min (rotation speed) rotation acceleration/deceleration Storage temperature : -10 to 50 °C
Display update time : approx. 1 s
Measurement accuracy (r/min) : ± 2 × rotation speed resolution (r/min) ± 1 count mode (Active); within 250 ms Operating (storage) humidity : 35 to 85% RH (with no condensation)
*Measurement accuracy depends on the frequency Measurement unit : r/min, r/s (rotation speed), m/min
Load resistance : 100 kΩ or more (circumferential speed), ms (period), Outer dimensions : 66 (w)×180.5 (H)×47.5 (D) mm (only main unit)
range.
Output connector : mini jack (ø 2.5/commonly used with COUNT (integration count) 66 (W) ×237.2 (H) ×57.5 (D) mm (contact
Rotation speed resolution (r/min) : frequency range (Hz) ÷ 6400 × 60 ÷
ANALOG output) Measurement range : adapter + rotation contact tip)
number of set pulses
General specification Applicable standard : CE marking
frequency range; 250, 500, 2000 (Hz) Non-contact type Contact type
Power supply : AAA battery ×4 or dedicated AC adapter Weight (excluding batteries) : approx.220g (only main unit)
number of set pulses; 0.5, 1, 1.5, etc. (P/R)
(PB-7090, sold separately) r/min (Hi level) 6 to 99999 6 to 20000 approx.282g (contact adapter+ rotation
6400; resolution of FFT
*It becomes coarse when the rotation speed is Battery life : approx. 6 hours (When the backlight is off.) r/min (Lo level) 6.0 to 600.0 6.0 to 600.0 contact)
accelerating or decelerating. approx. 5 hours (When the backlight is on.) r/s 0.10 to 999.99 0.10 to 400.00 Accessory : contact adapter (HT-0502)×1,
Filter function : Specifies the frequency range (rotation (When alkaline battery is used, at 20 ºC, rotation contact tip (KS-300)×1,
m/min 0.6 to 9999.9 0.6 to 400.0
speed range) to be measured within the excluding when using the NP-3000 series circumferential ring (KS-200 for m/min)×1,
selected frequency range. accelerometer*1) COUNT 0 to 99999 0 to 99999 reflective mark (12mm square, 25 sheets)
Averaging processing : moving average processing *1: When using the NP-3000 series accelerometer, ms 0.6 to 9999.9 2.5 to 9999.9 ×1,
consumption current increases by driving the AAA battery ×4,
number of averaging processing··· constant current power, so we recommend using Measurement accuracy : display value* × (± 0.02%) ± 1 count
OFF, 2, 4, 8, 16 the dedicated AC adapter. *Display value is the count value excluding the decimal carrying case×1,
Sensor amplifier sensitivity adjustment volume : Low battery display : When the battery voltage becomes point. instruction manual (function guide:
Sensor amplifier sensitivity can be approx. 4.2 V or less, the LOW mark is (Note) Japanese/English, basic operation:
adjusted with the rotary type volume displayed. • The measurement accuracy of Japanese/English)×1
knob on the right side of the main unit. Operating temperature : 0 to 40 ºC circumferential speed depends on the Option : pulse output cable; 2 m (AX-501)
Detection section Storage temperature : -10 to 50 ºC rotation speed of the rotating body. dedicated AC adapter (PB-7090)
Compatible sensors : dedicated for engine rotation measurement Operating (storage) humidity : 35 to 85% RH (with no condensation) • The above measurement accuracy is reflective mark; 12 mm square 25 sheet,
OM-1200/1500, VP-1220/202, Outer dimensions : 66.0 (W)×189.5 (H)×47.5 (D) mm for non-contact measurement. 10 sheet 1 set (HT-011)
IP-292/296, IP-3000A/3100, FT-0801 Compatible standard : CE marking It does not include errors due to circumferential ring for mm/s (KS-100)
FT-0501+FT-0150, NP-3000 series (with Weight : approx. 230g (not including battery) camera shake. Contact slippage and circumferential ring for m/min KS-200)
built-in preamplifier), MI series (microphone Accessory : AAA battery ×4, instruction manual accuracy are added at the time of rotation contact tip (KS-300)
+ preamplifier) (basic operation, function guide, contact measurement. contact adapter (HT-0502)
Input voltage level : 0.05 × 5 V (3-range switching) measurement procedure) ×1 each, Measurement function extension relay shaft for KS-300 (KS-700)
Input coupling : AC coupling carrying case ×1 Peak hold function : maximum value (MAX), stand jig (HT-0521A)
Power supply for NP series accelerometer : Option : relay cable for FT-0501; 0.5 m (FT-0150) minimum value (MIN) magnet stand (HT-0522)
constant current power supply output signal cable; 2m (AX-501) Memory function : up to 20 data measurement tripod (LA-0203D)
(2.4 ± 0.5 mA) dedicated AC adapter (PB-7090) Over range function : over range (ERROR mark) is displayed (Airy L 100 manufactured by SLIK)
*Note on measurement: depending on the type of engine magnet stand (HT-0522) when the measured value exceeds the
and measuring object, it may not detect properly.
stand jig (HT-0521A) measurement range.
measurement tripod (LA-0203 D)
* Please visit our website for more detail brochure of the FT-7200. (Airy L 100 manufactured by SLIK)
24 25
Handheld Tachometer HT-3200/4200/5510, HR-6800 Handheld Tachometer HT-5510, HR-6800
Handheld Digital Tachometer Handheld Digital Tachometer
HT-3200 Contact type / general purpose liquid crystal display HT-5510 Digital handheld tachometer
With a low range setting that can measure from 0.5 r/min. A circumferential ring/rotation contact can be stored in a pocket of the main body. Measurement unit : r/min, r/s (rotation speed), the measured rotation speed.
m/min (circumferential [contact type]

Won the
•Method
Specifications
: contact method
Over range display : "ERROR" is displayed.
Power requirement : AAA battery×3
speed, moving speed), ms
(period, moving time,
COUNT (integration count)) Integration count function:
Uses circumferential ring
KS-100/200
Good Design Display section : liquid crystal display, 5 digits Battery life : approx. 20 hours (using Measurement range : door opening and closing Measures the period of the
Award alkaline dry batteries, at speed measurement input pulse.
(character height 10. 5 mm)
Measurement unit : Lo range··· 0.1 r/min, 20 °C) ; 0.6 to 45 m/min (1 pulse Period measurement function :
Hi range··· 1 r/min Operating temperature : 0 to 40 °C interval 4 mm) Measures the period of
Display update time : 1 second automatic repeat Storage temperature : -10 to 55 °C door opening closing input pulse.
2 seconds at Lo range Operating (storage) humidity range : time measurement However, if it is less than
35 to 85% RH ; 0.6 to 9999.9 ms 1 second, average value of
; 0.5 to 1.0 r/min rotation measurement mode; input pulse
2 seconds at Hi range (with no condensation)
Outer dimensions : 63 (W) x 172 (H) x 38.5 (D) mm same as HT-5500 (P.25) Rotation speed : non-contact type
; 5 to 10 r/min Make-to-order Measurement accuracy : (with reflective mark),
Measurement range and accuracy of rotation speed : Applicable standard : CE marking
Weight : approx. 160 g product display value × (± 1%) ± 1 contact type (using KS-300)
Lo range··· 0.5 to 1249.9 r/min; count (Displayed value is a Output section [analog output]
within ±0.1 r/min (without batteries) count value excluding Output voltage : 0 to 1 V/0 to F.S. (Full scale
1250.0 to 2000.0 r/min; Accessory : contact tip for rotation decimal point.) is arbitrarily set.)
within ±0.2 r/min
Hi range···5 to 10,000 r/min;
measurement (KS-300) x2
(One of them is stored in the •Features Detection section
Detection method : visible light photoelectric
Conversion method : 10 bit D/A conversion method
Linearity : ± 1%/F.S.
• The HT-5510 is the model added two functions
•• Measurable
main body), circumferential reflection method Output update time : 50 ms + input pulse
Features within ±1 r/min
Circumferential speed measurement range: ring (KS-200 for m/min)×1 (opening and closing speed measurement and door Detection distance : 30 to 70 mm within 1 period time
from a low speed of 0.5 r/min to (stored in the main body) opening and closing time measurement functions) Light source : red light emitting diode Temperature stability : ± 0.05% / F.S./ °C (span &
KS-200 (provided) KS-100 (option) Light receiving element : phototransistor zero)
10,000 r/min (circumferential speed: 0.05 to Lo range 0.05 to 200.00 m/min 0.5 to 2000.0 mm/s AAA batteryx3, instruction to the HT-5500 handheld digital tachometer.
1,000.0 m/min). manual (English, Japanese) x1 Detection mark : 1 reflective mark/ 1 Full scale setting error : ± 0.5 % F.S.
Hi range 0.5 to 1000.0 m/min 5 to 10,000 mm/s Door opening and closing speed Door opening and closing time rotation, high precision Load resistance : 100 kΩ
• Large liquid crystal display on a compact, • It
is an accuracy calibration at rotation speed. each measurement measurement reflection zebra tape Output section [pulse output]
lightweight body (character height 10.5 mm). • The unit of measurement can not be
Option : circumferential ring for g ing
Measurement function Output voltage : Hi level···4.5 V or more
mm/s (KS-100), clos
in clos
• With memory function useful for checking changed. When using KS-200, setting the nd g and Peak hold function : maximum value (MAX), (when detecting with
ga enin
measurement results. measurement value to 1/10 will result in the circumferential ring for enin r op minimum value (MIN) reflective mark),
r op doo
• By replacing the contact tip with the attached m/min (KS-200), doo Memory function : up to 20 data Lo level···0.5 V or less
value in m/min.
Handheld Tachometer Handheld Digital Tachometer

Handheld Tachometer Handheld Digital Tachometer


circumferential ring, it can also measure Memory function : number of memories··· 10 rotation contact tip Over range function : Over range (ERROR mark) Output logic : positive logic
circumferential speed. Data hold function : automatic power off 30 (KS-300), is displayed when a Load resistance : 100 kΩ or more
• With a pocket to store the circumferential ring. extension shaft for zebra measured value exceeds General specification : P.25 same as HT-5500
seconds after the end of reflective
the measurement range. Accessory : high precision reflective zebra
• Continues to display the latest measurement measurement KS-300 (KS-700), tape mark
value for approx. 30 seconds after power-off. a carrying case (HT-0300) Rotation upper limit warning function : tape (1 m) x 2 rolls 1 set
Low battery display : “LOW” mark is displayed When the rotation speed Other accessories are same
• Displays the timing of battery replacement. when the battery voltage exceeds the preset upper as P.25 HT-5500.
drops below 3.3 V. •Measurement
Specifications
section
limit value, displays upper
limit warning (↑ mark).
Option : high precision reflective zebra
tape (1 m) x 2 rolls 1 set
Measurement method : visible light reflection Circumferential speed calculation function : Other optional items are same
method [non-contact type] as P.25 HT-5500.
HT-4200 Non-contact type/general-purpose liquid crystal display Calculation method : period calculation method
Measurement time : 50 ms + input signal
within one period time
Calculates the circumferential
speed from the preset
diameter value (mm) and
Affix a reflective mark to the rotating body of the measurement target object, and then aim the red visible light at the mark. By attaching multiple
reflective marks, it is possible to measure from a lower speed. HR-6800 High rotation speed measurement model
Won the
•Detection
Specifications
method : red visible light
Memory function : 10 data can be memorized.
Data hold function : auto power off when 30
Measurement time : 50 ms + input signal within
10 periods
Low battery display : “LOW” mark is displayed
when the battery voltage
Good Design seconds have elapsed Display update time: approx. 1 s/approx. 0.5 s drops below 4.5 V.
Award photoelectric reflection after the end of selectable Operating temperature : 0 to 40 °C
method measurement. Measurement unit : 10 r/min (rotation speed) Storage temperature : -10 to 50 °C
Detection distance : 20 to 300 mm Low battery display : “LOW” mark is displayed Rotation speed measurement range : Operating (storage) humidity :
Display : LCD, 5 digits (character when the battery voltage 100 to 999,990 r/min 35 to 85% RH (with no
height ; 10.5 mm), fixed drops below 3.3 V. (range selectable) condensation)
measurement unit (r/min) Over range display : “ERROR” mark is displayed. Measurement accuracy : Outer dimensions : 66 (W) × 189.5 (H) ×
Display update time : 1 second automatic repeat display value × ± (0.02 %) 47.5 (D) mm
Power source : AAA battery×3 ± 1 count Applicable standard : CE marking
(however, 2 seconds when Battery life : approx. 20 hours (when
the circumferential speed Peak hold function : maximum value (MAX), Weight : approx. 230 g (main unit
using alkaline batteries at minimum value (MIN) only, not including dry
is lower than 60/reflective 20 ºC) Memory function : up to 20 data batteries)
marks r/min) Operating temperature : 0 to 40 ºC Over range display : When the measured value Accessory : AAA battery×4, adapter
Measurement range : measurement unit ;1r/min Storage temperature : -10 to + 55 ºC exceeds the measurement for tripod mounting
Affixing of multiple reflective Operating (storage) humidity : range, over range (ERROR (MI-0301)×1, carrying
marks enables measurement 35 to 85 %RH (with no mark) is displayed. case×1, instruction manual
of lower rotation speeds. Rotation upper limit warning function : (basic operation, function
•• The
condensation)
Features
5-digit display enables wide-range
Measurement range
30 to 50,000 r/min
Number of reflective marks
1
Outer dimensions : 62 (W)×129(H)×26.4 (D) mm
Applicable standard : CE marking
•• High-speed
Features
rotation measurement from 100 to
When the rotation speed
exceeds the preset upper Option
explanation) × 1 each
: output signal cable 2m
15 to 25,000 r/min 2 limit value, upper limit (AX-501)
measurement from 4 to 50,000 r/min (when Weight : approx. 90 g (not including 999,990 r/min warning (↑mark) is dedicated AC adapter
10 to 16,667 r/min 3
several reflective marks are used). 8 to 12,500 r/min 4
batteries) • Built-in memory function, up to a maximum of 20 displayed. (PB-7090)
• A large-size display (character height 10.5 mm) 5 to 8,333 r/min 6 Accessory : reflective marks 1 sheet data can be saved to memory. Analog output section : output voltage; 0 to 1 V/0 Stand jig (HT-0521A)
is adopted to the compact, lightweight body. 4 to 6,250 r/min 8 (12 mm square×25 marks), • Both analog and pulse outputs provided as to F.S. (F.S.: arbitrarily set.)* Magnet stand (HT-0522)
• Memory function for easy confirmation of the AAA battery×3, standard. Used for recording rotation speeds, output update time; 50 ms Measurement tripod
measurement results Measurement accuracy (when one reflective instruction manual (English, + input pulse within 10 (LA-0203D)
mark is used) : 30 to 12,499 r/min; confirming detected waveforms and as rotation
• Even it is shiny shaft its rotation can be Japanese)×1 each period time (Airy L 100 made by SLIK)
within ±1 r/min synchronization signals Monitor output : for monitor analog output Tripod mounting adapter
measured by using the reflective marks Option : reflective mark 12mm • Built-in peak hold function: The maximum and
provided as standard. 12,500 to 24,999 r/min; square×25; 10 sheets 1set after waveform shaping of (MI-0301)
within ±2 r/min minimum values can be displayed during sensor pulse (before pulse Detection section (sold separately)
• Measurement can be performed over a wide (HT-011) measurement.
25,000 to 50,000 r/min; waveform conversion) Dedicated detector : MP-5350
range from 30 to 50,000 r/min, in 1 r/min unit carrying case (HT-0400), • Large LCD with backlight Pulse output : 1 pulse output per pulse Detection method : electromagnetic induction
(When one reflective mark is used.). within ±4 r/min soft case (HT-0003) detection method
• Safe measurement available for being detectable
from a position away from the measurement
Pulse number setting function :
The number of reflective •Measurement
Specifications
section
output voltage;
Hi level···4.5 V or more,
DC resistance value : 25 to 40 Ω (20 °C)
Connection cable : 1 m (both ends BNC
target (20 to 300 mm). marks used can be Lo level···0.5 V or less (included) connector included)
specified in order to Measurement target: rotating objects used in
• Continuously displays the latest measurement dentistry, texturizing Power supply : AAA battery ×4 or a Operating temperature : 0 to 40 °C
value for 30 seconds after power off. perform measurement machine, high-speed dedicated AC adapter Storage temperature : -10 to 50 °C
• Displays the timing of battery replacement. from lower rotation speeds. machine tools (PB-7090, sold separately) Vibration and shock resistance :
setting values; 1, 2, 3, 4, Note: target measurement Battery life : approx. 13 hours (when 19.6 m/s2 · 490 m/s2
6, 8 P/R objects must be magnetized. the backlight is OFF), Outer dimensions : 107 x ø 14 mm
Display section : LCD with backlight, 5-digit approx. 8 hours (when Applicable standard : CE marking
(character height: 10.2 mm) the backlight is ON) (using Weight : approx. 50 g (detection
alkaline batteries, at 20 °C) section only)
*Please refer to HT-5500 for electrical specification of
26 analog output. 27
Related Products
Length Meter RV-3150
Elevator Speedometer EC-2100 Reversible Counter
Handheld Type Speedometer •Features
• Reversible counter designed to measure linear position, displacement,
Resolution : 0.1 (m/min/average number 10 or Current consumption : 100 mA max.
Options more), 1 (r/min, average number (power voltage 4.5 V) dimensions and so forth
10 or more), 1 (mm) Operating temperature : 0 to 45 °C • Easy-to-read large size LED (14 mm)
Measurement unit : m/min, r/min, mm (option) Storage temperature : -10 to 60 °C • Wide range of external output functions (comparator, analog, BCD,
Auto power off function : Operating (storage) humidity :
a delay of 180 seconds after 35 to 85 % (RH) (with no and RS-232C communication)
last operation automatically condensation) Four comparator setting values can be saved as conditions
•Specifications
EC-0203 turns the power off. Outer dimensions : 60 (W) × 162 (L) ×38 (D) mm
Data hold function : data hold of each channel CE marking : applicable
(CH 1, CH 2, Max value, each Weight : approx. 423 g (including Applicable sensor : RP series (Rotary encoder)
independent) batteries, not including the
Averaging function : 1 to 200 times (optionally setup) circumferential ring) RP-7400 series (Roller encoder)
Memory function : Up to 10 measurement results Accessory : EC-0922 external hold signal GS series (Linear gauge sensor)
can be stored in the main unit. cable (1.4m) x 1 set *Conversion cable required
Output section (2 pieces) Display section : main display; red LED (14mm), 6-digit and polarity
Analog output : output content; EC-0925 carrying case x 1 piece (0 to ±999999)
EC-0201 hexagonal wrench
instantaneous value (output sub display; LCD, 16 characters x 2 lines, with
after averaging processing) (opposite side:1.5mm) x 1 piece
voltage range; 0 to 1 V/0 to F.S. AA battery x 3 pieces 144 180 (11) backlight (yellow green)
conversion method; Instruction manual x 1 piece decimal point; 0, 0.0, 0.00, 0.000 (selectable)
•• Analog
Features 10-bit D/A conversion Option : EC-0202 Distance measurement condition display; comparator condition;
Reversible Counter RV-3150

UPPER

linearity; ±1% F.S. function GOOD


LOWER
UPPER (red) / GOOD (green)
output function

72
output update time; 10 ms *If ordering after delivering the main RESET MENU
/ LOWER (red)
• Maximum value hold function output connector; ø 2.5 mm unit, installation fee is required SELECT

• Memory function pin-jack separately.


COMP
ON/OFF
SET
NEXT

Sensor input signal : single phase or 90°phase difference square wave voltage pulse
Pulse output : output method; transistor output KS-400 circumferential ring (Hi...4 to 30 V, Lo...0 to 1 V)
• Function of remaining battery level MAX4
(open collector) (wide type) ;15 mm line receiver (conforms to RS-422A)

(9.5)
• Auto power off function KS-500 circumferential ring
• Averaging function withstand voltage; 14 V input frequency range...DC to 100 kHz
current; 20 mA or less (narrow type) ;2 mm
• Distance measurement function (option) KS-0800 circumferential ring Power supply for sensor : selectable from
number of pulses; 600 pulses
•Measurement
Specifications / rotation (rubber coating wide 5 ± 0.25 VDC (max 150 mA)
BCD-OUT POWER
T1 EXT-IN

logic; negative logic type) ;15 mm 12 ± 0.6 VDC (max 120 mA)

+0.5
T2 SIG-IN

0
100−240V ∼

method : contact type


50/60

KS-300 rotating contact tip


RS-232C
30VA MAX

External control signal : format of input signal; voltage input (Hi; 4 to 5.25 V,

68
pulse width; approx. 0.5 to 1.2 µs
FUSE 2A T

Measurement range : EC-0924 relay shaft for rotating


T3 OUTPUT

speed; 0.1 to 2,000.0 (m/min) output connector; ø 2.5 mm Lo; 0 to 1 V), Non-voltage
pin-jack contact tip
rotation speed; 1 to 20,000 (r/min) EC-001A external hold detection 138 +0.5
contact input
Detection section
0

distance (option); 0 to ±999 (mm) switch types of input signal; reset, gate, offset, key protect
*Distance measurement up to ±5000 mm is available. Number of generated pulses : Rear view Panel cut dimension
150 pulses/ rotation, slit reflection EC-0921 signal cable (5 m) Mode/function : multiplication; 1/2/4
However, measurement values more than ±999 mm is not
EC-0923 pulse output cable

・System Configuration Example


guaranteed. method ratio compensation range; 0.000001 to 0.999999
Measurement accuracy : Light source : infrared-emitting diode (2 m)
EC-0926 trigger unit cable exponent value; 1/1, 1/10, 1/100, 1/1000
±1 count (not including the error Light receiving element : photodiode offset setting range; 0 to ±999999
due to camera shake and Allowable shaft load : radial; 5 kg, thrust; 5 kg (1.5 m)
slippage of contact part.) Bearing life : 2×107 r/min·h (maximum load AX-501 analog output cable Comparator function : setting range; 0 to ±999999
Measurement time : 10 ms within the specification) (2 m) setting step; 2 steps
Display : 5-digit, 7 segment, red LED in General specification EC-922 external hold signal
Marker output parameter; LOWER (Lower setting value ≧
two-step display Power supply : AA battery x 3 pieces cable (1.4 m) × 1 set
(2 pieces)
RP-7400 series Comparator calculated value)
Display update time : 100 ms Battery life : 15 hours or more Roller encoder GOOD (Lower setting value <
EC-0925 carrying case × 1 piece
Related Products

Related Products
(continuous using at room
temperature) * Please visit our website for more details on EC-2100.
calculated value < upper
setting value)
RP series UPPER (Upper setting value ≦
Line Speedometer (Roller Encoder) RP-7400 series Rotary
encoder
calculated value)
output format; semiconductor relay (single make
Low to medium speed applications contact each)
Max. contact capacity; 30 VDC, 0.1 A
•• Number
Comparator
Features Weight : approx. 400 g update time: within 15 ms
BCD
Accessory : instruction manual x 1 BCD Input/Output : output signal (BCD, polarity, judgment, error, print
of pulses selectable from 120, 200, or connector (RM12BPE-5S) x 1; command)
Elevator/Line Speedometer

Length Meter
1200 P/R HIROSE Electric Co., LTD.
• Wide variety of output signal Mechanical specification open collector (withstand voltage: max. 30 V)
PLC
Totem pole (standard), Collector (option) Speed range : 0 to 600 m/min control signal (reset, hold)
Emitter (option), Open collector (option) *Speed measurement range depends input format (voltage input); Hi; 4 to 5.25 V, Lo; 0 to 1 V
on condition of measurement object.
Analog output : output voltage range; 0 to ±10 V/F.S. (F.S. can be set
•Electrical
Specifications
specification
Measurement unit : 120 P/R 0.1 m/min
1200 P/R 0.01 m/min arbitrarily.)
200 P/R 1 mm Analog load resistance; 10 kΩ or more
Number of output : speed; 120, 1200 P/R
pulses length; 200 P/R
Roller material : mandrel; aluminum linearity error; ± 0.3 % of F.S.
rubber; polyurethane rubber calibration function; ZERO / FULL, 12 bit D/A method
Output waveform : 2-phase rectangular wave
baked on the roller update time; within 15 ms
Duty ratio : 50 ±25 % Recorder
surface (rigidity A90)
Phase difference : 90 ±45° RS-232 communication : function; readout of data and parameter, setting of
Roller outer circumference : 200 mm
Output voltage (when 12 VDC is supplied.) : parameter
Maximum allowable load : radial 20 N
Hi; 10 V or more, Lo; 0.5 V or less
Output method : Totem pole output (load
Starting torque : 1 mN·m baud rate; 2400/4800/9600 bps
Moment of inertia : 0.6 kg·cm2 Power requirement : 100 to 240 VAC (50/60 Hz)
resistance 470 Ω or more)
Options; RP-0701 Emitter output Vibration resistance : 19.6 m/s2 Power consumption : 30 VA or less
X/Y/Z each direction (150 minutes RS-232C
RP-0702 Collector output
103
RP-0703 Open collector each) Operating temperature : 0 to +40 °C
M4 Depth8 PC Storage temperature : -10 to +55 °C
output 10 to 150 Hz sweep, 20 cycles
10

Power supply : 12 VDC±5 % (100 mA or less) Shock resistance : 196 m/s2 Operating/storage humidity : max. 95 % (with no condensation)
47
23
10

General specification X/Y/Z each for ± both directions Weight : approx. 1.3 kg
HIROSE Electric Co., LTD. Operating temperature : (for 6 directions)
10

Model:RM12BRB-5PH 0 to +50 °C (with no freezing,


Withstand voltage : 1500 VAC (between power supply·GND, 1 min)
54 3 times for each (total 18 times)
66

no condensation) semisinusoidal wave, operating Insulation resistance : 10 MΩ or more (at 500 VDC mega)
3.
35.5

ø6

2-ø10H7
Storage temperature : time 11 ms Accessory : power cable x 1, panel mounting fixture x 1 set,
-10 to +65 °C (with no freezing, Mounting hole (position) : stand foot x1 set, rubber foot x 1 set, terminal socket
30

no condensation) ø10 mm x 2, 20 mm of interval (5 pins) x 1/ (10 pins) x 2, instruction manual x 1


Operating humidity : Option : RP-0701 Emitter output
35 to 93 % RH or less (with no
Option : BCD cable 3 m (AA-8107)
105 RP-0702 Collector output
20 118 freezing, no condensation) RP-0703 Open collector output RS-232C cable 2 m (AX-5022)
(180) Protection class : IP 40 (when RP-0181/0182 cable RP-0181 cable (5 m) P.34-35
used) RP-0182 cable (5 m) P.34-35
CE marking : applicable
* Please visit our website for more details on RP-7400 series.
28 29
F/V
F-V Converter
Converter FV-1100 F/V
F-V Converter
Converter FV-1500
Frequency-to-Voltage/Frequency-to-Current Converter Frequency-to-Voltage/Frequency-to-Current Converter
General-purpose type High response type
•Specifications Input format : single-phase, AC/DC/non-voltage selectable (+12 V
pull-up for open collector devices)
Conversion method : Constant width pulse integration method Two-phase signal with 90° phase difference (DC input only)
Frequency range : 10 kHz (optionally available of specifying other Filter : OFF / 20 kHz / 120 kHz low-pass filter
frequency) Analog output terminal signal :
Response : 30 ms (Varies according to the frequency voltage output; 0 to 10 V (Full scale mode signal output,
optionally specified.) direction recognition function OFF)
Input frequency range : 10 kHz (Frequency in the range from 100 Hz ± 5 V (Full scale output mode, direction
to 100 kHz can be specified as an option.) judgment function ON, deviation mode,
Input terminal : BNC (C02), terminal block (3.5 M) automatic center frequency follow-up
mode)
Input voltage : AC input; sine wave ; 0.2 to 50 Vrms
Load resistance 100 kΩ or more
square wave ; 0.6 to 70 Vp-p current output; 0 to 16 mA (at the time of shipment)/4
DC input; rectangular wave ; Hi +4 to +30 V to 20 mA
Lo -1 to +1 V Load resistance 500 Ω or less
pulse width ; 3 µs or more Linearity : voltage output; DC: ±0.1 % ( to 180 kHz),
Input impedance : 80 kΩ or more (20 kHz), 30 kΩ (100 kHz) ±0.2 % ( to 320 kHz)
•Features Output terminal : terminal block (3.5 M) •Features AC: ±0.2 % ( to 180 kHz),
±0.4 % ( to 320 kHz)
• Withstand voltage: 2000 VAC 1 minute (chassis, Output voltage : 0 to 10 V, load resistance 1 kΩ or more • Wide frequency range: 0.2 Hz to 320 kHz
(0 to 5 V/ 0 to 1 V/ 0 to 0.1 V: available as an option) current output; DC: ±0.7 % ( to 180 kHz),
primary power supply) • High-speed response of every signal period ±1.4 % ( to 320 kHz)
• Equipped power supply for detector as standard Output current : 4 to 20 mA, load resistance 500 Ω or less • Rotation direction judgment using two-phase signal AC: ±1.4 % ( to 180 kHz),
(12 VDC, 100mA). (setting also available in the range from 0 to 16 mA) input ±2.8 % ( to 320 kHz)
• AC/DC input signal selectable. Linearity : within ±0.2 % of the maximum rated value • Rapid deceleration follow-up function Analog output low pass filter : OFF/ 3 Hz/ 10 Hz/ 1 kHz selectable
• Frequency range can be optionally specified from Ripple : 0.1 % of the maximum rated value or 10 mV or less • Automatic center frequency follow-up function can Analog output terminal : BNC/C02 type (voltage output) or terminal
100 Hz to 100 kHz. (standard: 10 kHz) (Fixed to the (When the frequency input is 5 % of the analyze transient fluctuation component (option) block (phoenix contact: MC1,5/6-STF-3,81)
frequency range.) (voltage output) selectable
specified frequency. The setting cannot be changed.)
• Data output as current and voltage signals can be Detector power supply : 12 VDC ±10 % 100 mA •Specifications D/A resolution : 16-bit
Power requirement : within AC 85 to AC 110 V, 46 to 63 Hz Response : within 1period time of input Display : fluorescent display tube
recorded to a pen recorder, and displayed to other frequency + 3.5 µs
(110/120/200/220/240 VAC on request) (display range 69.85 mm × 11.45 mm)
indicators, etc. Input voltage : AC input signal voltage range; Display unit : Hz, r/min, m/min, USER
• Compact monofunction type. Simple to use for Operating temperature range : 0 to +40 ºC 0.3 to 30 Vp-p Power requirement for sensor :
smoothing the input frequency and indicating the Weight : approx. 2 kg DC input signal voltage range; 12 VDC ±10 %, 150 mA / 5 VDC ±10 % 150 mA
average behavior or variation. Accessory : power cable for 100 VAC (AX-2050N, 3m) x 1 Hi +4 to +30 V, Lo 1 V or less Selectable by switch on the real panel.
flat-bladed screwdriver x 1 Input frequency range : 0.2 Hz to 320 kHz Operating power voltage range :
panel mounting fixture x 1 when fullscall mode output; 16 VDC dedicated AC adapter (100 to 240 VAC)
instruction manual x 1 • Arbitrarily setting available in every provided as standard
1 Hz at the range from 1 to Operating temperature : 0 to +40 ºC
320,000 Hz. Storage temperature : -10 to 50 ºC
•Arbitrarily setting available in every Operating humidity : 5 to 80 % RH (with no condensation)
1 r/min at the range from 1 to Storage humidity : 5 to 85 % RH (with no condensation)
Related Products

Related Products
320,000 r/min. Weight : approx. 1 kg
•Arbitrarily setting available in every Accessory : dedicated AC adapter (AC adapter: PS-P20023A
Panel mounting fixture
4 1 m/min at the range from 1 to cable: VM1072-VM1700 2m) x 1, instruction
(provided) 320,000 m/min. manual x 1, connector (MC1.5/6-STF-3.81)× 1
when in deviation output mode; (equipped with the main body)
F/V CONVERTER FV-1100 Arbitrarily up to 320 kHz of CE marking : Low Voltage Directive; 2006/95/EC EN61010-1:2010
measurement frequency EMC Directive; 2004/108/EC EN61326-1:2006
PL SIG IND ±1 %, ±5 %, ±10 %, ±20 %, Class A Table 2
±50 %, ±100 % or ±1 to
99±0.8

FREQUENCY 10k Hz

Option : FV-0151 (Automatic center frequency follow-up function)


50

OUTPUT VOLT 0.10 V

180,000 (can be set in every FV-0152 (Comparator output function)


F-V Converter

F-V Converter
POWER
ON OUTPUT CURR 4.20 mA


RESPONSE
t 10 90%
30 mS 1 Hz, 1r/min, 1m/min) FV-0153 (Deviation scale change function)
Input terminal : BNC (C02) or terminal block FV-0154 (Open collector output function) 
selectable
6

FV-0014 (Panel mounting fixture)

205 (5.5) 180 (16.5)


(10)

225
270
245 Panel mounting fixture
250
4-M5

44

6
OUT ADJ
(6)

V I No.
Z F Z F ONO SOKKI CO. LTD.
E U E U MADE IN JAPAN
R L R L
O L O L
100 +10
50

0.16AT 0.16AT
170 146
INPUT

FUSE FUSE

210 200
INPUT OUTPUT
V I AC100V
SIG COM 0V 12 V HI LO HI LO

215

230

Rear view
Panel cut dimension
Rear view

* Please visit our website for more details on FV-1500.


30 31
Isolated Signal Amplifier PA-150
Signal Amplifier Coupling Selection Guide
•Features Rigid coupling of the electromagnetic type rotation detector with a device is required condition for the accurate transmission to
• Used as an amplifier for electromagnetic detectors under electrically bad both rotation and angle. If it has mounting errors including differences in shaft core and allowance in thrust direction, all of them are
environment. received as elastic deformation of the bearing, and it will cause the decrease of accuracy or damage .
• Converts the input signal into a high-voltage low-impedance signal to
transmit the signal to remote locations accurately. For stable and long use with rigid coupling, the shaft misalignment should be within 6/1000 m.
• 12 VDC power terminal for use with various sensors. When you cannot make shaft centering with that accuracy, it is necessary to use flexible coupling which can accept the differences
• Terminal block allowing easy wiring, sealed structure, a take-off vent for in shaft center and the allowance in thrust direction.
various plumbing and cabling methods. There are various kinds of flexible couplings, such as one with high torsional rigidity, one suitable for general rotation speed
• Isolated shielded type to allow installation on site. Noise-resistant. measurement. It must be selected according to the application. Please perform the centering work as carefully as possible to
•Specifications prevent dynamic and static loads on the shaft beyond allowance.
Input amplification : AC amplification
Input impedance : differential input: approx. 70 kΩ (50 kHz)
single-ended input: approx. 45 kΩ (50 kHz) • Recommended coupling shape/weight
Input waveform : sine wave or rectangular wave (with a duty of approx 1:1)
Fig.1 Rubber flex coupling Fig.2 Center flex coupling
Input sensitivity : sine wave input ; 0.1 Vrms,
RF-100 CF-A-002-02
rectangular wave input ; 0.3 Vp-p
(max. allowable bias voltage: ± 1 VDC) 66 62
320
Frequency range : 1 Hz to 50 kHz
Operating voltage range : sine wave input ; 0.1 to 30 Vrms
7

rectangular wave input ; 0.3 to 30 Vp-p


Max. input apply voltage : sine wave; 100 Vrms, rectangular wave; 100 VDC
100

Output waveform : rectangular waveform

ø100

ø85
Voltage output : max. peak voltage (Vp-p) ; 12 ±1 V
max. bias voltage (VBIAS) ; 0.5 V or less
*The max. peak voltage and bias voltage between COM2 and OUT1/2
Upper without load while OUT2 and OUT1 is shortened.
310 cover 146
Grommet output impedance; approx. 330 Ω Rubber
with seal Open collector output : collector maximum applied voltage; 40 VDC
collector maximum input current; 50 mA 1200 g 1000 g
*Between OUT2 and OUT1; open
(112)

Between OUT1 and COM2; collector maximum applied voltage, and


collector maximum input current
Power source : 12 VDC ± 5 %, 100 mA max. Acceptable eccentricity,
(332) Operating temperature : -10 to 40 ºC Coupling name Application Features Detaching method Remarks Manufacturer
Case deflection angle [Note 1]
Storage temperature : -20 to 70 ºC
Power requirement : 100 VAC ±10 %, 50/60 Hz Rub flex coupling MP-810B • Relaxation of rubber Rotation speed: Attach the flange to the At high speed, expansion of Nitta Chemical
Power consumption : approx. 8 VA RF-100 etc. Fig.1 MP-200 impact elasticity 2000 r/min detector and the machine the rubber due to centrifugal Industrial Products
Weight : approx. 4 kg • Vibration damping Deviation: 1.5 mm side. After setting to the power causes a thrust Co., Ltd.
Accessory : crimp terminal x 11, fuse for 200/220V x 1, Deflection angle: 6 ° dimensions specified in the power and it damages the
instruction manual x 1 centering rules, attach the detector.
Terminal block : applicable to JIS C 2805 2-4 crimp terminal rubber tire. Removable Drive side shaft diameter
without moving system. ø 10 to ø 22 [Note 2]
Isolated Signal Amplifier PA-330Z
Related Products

Related Products
Center flex coupling • Absorbs vibrations Rotation speed: Attach the flange hub and Drive side shaft diameter Miki Puli Co., Ltd.
Signal Amplifier CF-A-002-02 Fig.2 and shocks 5000 r/min hub to the detector and the ø 10 to ø 25
• Does not occupy wide Deviation: 0.5 mm machine side, and attach
•Features space in the axial
direction
Deflection angle: 1 ° the rubber body after
centering.
• Can be used as an insulated amplifier by receiving square wave output from
rotary encoder.
• Low impedance transmission for long distance available by wave-shaping. [Note 1] Allowable eccentricity and deflection angle are the ranges in which the performance as a coupling can be guaranteed. However, please avoid installing in the
• Supplies 12 VDC to DC power type RP series. way that the detector shaft exceeds the specified load even if it is within the permissible range.
• The case is sealing structure which allows close mounting to the encoder. [Note 2] Customers should prepare hole machining on the drive shaft side.
• Isolated shielded type to allow installation on site. Noise-resistant.
Signal Amplifier

Coupling
•Specifications * For details of coupling, please contact each manufacturer.
Number of input phases : three-phase
Input resistance : 470 Ω
Input waveform : rectangular waveform approx. 50 % duty
Input voltage : Hi; 8 to 12.5 V, Lo; 0 to 4 V
Frequency range : 0 to 50 kHz
Output voltage : Hi; 10 V±2 V (5 kΩ load), Lo; 0.5 V or less (5 kΩ load)
Output resistance : collector resistance 330 Ω
Delay time : approx. 2 µs between input and output
320 Operating power supply : 100 VAC, approx. 12 VA
Power source : 12 VDC, 0.15 A
Operating temperature : -5 to 40 ºC
7

Storage temperature : -10 to 70 ºC


Weight : approx. 4 kg
100

Accessory : crimp terminal


Terminal strip : applicable to JIS C 2805 1.25 to 3 crimp
Upper cover terminal
Grommet
Optional modification :
310 146
with seal Item Modified specification Standard
Open collector output Max. rating : 40 VDC, 50 mA Collector output
AC110 V
Power voltage AC200 V 100 VAC
(112)

AC220 V
1.5 kΩ
Input resistance 470 Ω
47 kΩ*
Output resistance 220 Ω (Output Z is not available.) 330 Ω (three-phase)
Case Please specify the item and specification to be modified when ordering.
(332)
* Modification of input resistance to 47 Ω is required when RP-1700 series with
C specification (collector output type/ pull up resistance 470 Ω) is used.

32 33
Table of Signal Cable
Item Compatible Detectors Cable Model Name Specifications Compatible Products Non-compatible Products Remarks

1 MP-9100/9120/9200/940A/963 3C-2 V MX- 005 5m FV-1100/1500 Counter without a BNC input connector Connector Pin Signal
MP-810/820/830 (High-frequency coaxial 010 10m HS12PA-2 CO2 type (BNC) plug * However, if the input connector is connected to the terminal 1 SIG
(MP-081+MX-005 series) cable) 015 *15m block's display unit, connection is enabled by using a cable 2 COM
020 *20m combination (MX-000 series+ MX-603.)

2 MP-930/935/936/950/954/962 3C-2 V MX- 101 1.5m FV-1100/1500 (e.g.) Counter without a BNC input connector The following models have a directly attached cable.
MX-100 series MX-603
FG-1300 (High-frequency coaxial 105 5m TM-3100 series TM-3110 * However, if the input connector is connected to the terminal MP- 930: 0.5 m MP- 950: 0.5 m
CO2 type (BNC) plug CO2 type (BNC) plug
cable) 110 *10m TM-5100 block's display unit, connection is enabled by using a cable 935: 1 m 954: 0.5 m
115 *15m * A terminal block socket is used combination (MX-100 series+ MX-603.) 936: 1 m 962: 0.5 m
MP-950
120 *20m for the TM-5100 input and output
sections. To enable connection, processing is required to make
the cable end left open by removing a crimp terminal.

3 MX-000 series cables, P-2 MX- 603 0.3m (Junction cable) PA-150 (e.g.) Use only for connecting the compatible detectors at
MX-100 series
MX-100 series cables (2-core outer shield cable) CO2 type (BNC) jack TM1.25-3.5S TM-3100 series MX-603
TM-3110
item No.1 & 2 when the input connector is the
TM-5100 terminal block's display unit.
* A terminal block socket is used MP-950
Connector Color of Code Signal
for the TM-5100 input and output The Center Contact White SIG
sections. To enable connection, processing is required to make Shell Green COM
the cable end left open by removing a crimp terminal. Shell Shieid Case Ground

4 MP-9100/9120/9200/940A/963 P-2 MX- 505 5m FV-1500, PA-150, TM-3100 series/5100 Counters without an input terminal block Connection to counter
MP-810/820/830 (2-core outer shield cable) 510 10m HS12PA-2 TM1.25-3.5S * A terminal block socket is used for the TM-5100 input and output Connector Color of Code Signal
(MP-081+MX-500 series) 520 20m sections. To enable connection, processing is required to make the Contact 1 White SIG
cable end left open by removing a crimp terminal. Contact 2 Green COM
Housing Shieid Case Ground

5 MP-981/9820 D5-UL MX- 7105 5m FV-1100/1500, PA-150, TM-3100 series/5100 Connection to counter
LG-9200 (Composite 5-core vinyl 7110 10m R04-PB6F TM1.25-3.5S Connector Pin Color of Code Signal
* A terminal block socket is used for the TM-5100's input and output
sheath cable) 7115 15m sections. To enable connection, processing is required to make the A Blue SIG
B White Unused
7120 20m cable end left open by removing a crimp terminal. C Red +12 V
D Shield Case Ground
E Green COM
F Black 0V

6 MP-981/9820 D5-UL MX- 8105 5m TS-2800/3200A (LG-9200 cannot be used.) Counters other than those listed in the column at the The connector pin arrangement is the same as
R04-PB6F R03-PB6M
LG-9200 (Composite 5-core vinyl 8110 10m left MX-7105 to 7120.
sheath cable) 8115 15m
8120 20m

7 RP-7400 series D5-UL RP-0181 5m PA-150 Counters without an input terminal block Connector Pin Color of Code Signal
(Composite 5-core vinyl *10m RM12BPE-5S TM1.25-3.5S TM-3100 series 1 Blue SIG1
Related Products

Related Products
2 White SIG2
sheath cable) Red +12 V
3
4 Shield Case Ground
Green/Gray COM
5 Black 0V

8 RP-7400 series D5-UL RP- 0182 5m RV-3150 Connector Pin Color of Code Signal
(Composite 5-core vinyl *10m RM12BPE-5S TM-5100 1 Blue SIG1
sheath cable) 2 White SIG2
3 Red +12 V
4 Shield Case Ground
Green/Gray, Green/Brown COM
5 Black 0V
Signal Cables

Signal Cables
9 TM-3100 series Power cable for general AX- 2050N 3m Crimp terminal M3 AC plug 3P
purpose Compliant with Electrical Appliance and
Material Safety Act

* Made to order

• When several counters are connected to one detector, Example of using CO2 type (BNC)-JPJ • R6 Cable
you will find it convenient to use BNC-JPJ connector. JPJ
Vinyl sheath Drain wire Identification of wire core
MX-005 MX-105 Tape 1 No. 1 2 3 4 5 6
2
Color Blue Green/Gray White Green/Brown Red Black
Counter Counter 5 6
3
4
Detector Conductor
Shield
Insulator

34 35
WORLDWIDE ONO SOKKI CO., LTD.
1-16-1 Hakusan, Midori-ku, Yokohama, 226-8507, Japan
Phone : +81-45-935-3918 Fax : +81-45-930-1808
E-mail : overseas@onosokki.co.jp
* Outer appearance and specifications are subject to change without prior notice.
URL: http://www.onosokki.co.jp/English/english.htm

U.S.A. THAILAND INDIA P.R.CHINA


Ono Sokki Technology Inc. Ono Sokki (Thailand) Co., Ltd. Ono Sokki India Private Ltd. Ono Sokki Shanghai Technology Co., Ltd.
2171 Executive Drive, Suite 400, 1/293-4 Moo.9 T.Bangphud A.Pakkred, Plot No.20, Ground Floor, Sector-3, Room 506, No.47 Zhengyi Road, Yangpu
Addison, IL. 60101, U.S.A. Nonthaburi 11120, Thailand IMT Manesar Gurgaon-122050, District, Shanghai, 200433, P.R.C.
Phone : +1-630-627-9700 Phone : +66-2-584-6735 Haryana, INDIA Phone : +86-21-6503-2656
Fax : +1-630-627-0004 Fax : +66-2-584-6740 Phone : +91-124-421-1807 Fax : +86-21-6506-0327
E-mail : info@onosokki.net E-mail : sales@onosokki.co.th Fax : +91-124-421-1809 E-mail : admin@shonosokki.com
http://www.onosokki.net E-mail : osid@onosokki.co.in

CAT. NO. 173-47E Printed in Japan 192 (SUN) 0.5K

You might also like