PACKINGS
STYLE 7302K
Style 7302K
Services: Rotary, reciprocating
O
Temperature Range : 260 C
pH Range : 2 – 12
Max Pressure : 36 Bar
Max Surface Speed : 11 metres per second
Installation Procedures:
1. Remove all the old gland packing and clean the stuffing box properly
2. Make sure the packing is the correct size
O
3. Cut the packing the correct length and angle (45 : see illustration below)
4. Clean the packing rings and lubricate them
5. Install the first ring - let it seat in front
6. Seat the remaining rings one at a time
7. Make sure the gland follower seats into the stuffing box and finger-tighten the
gland follower nuts