You are on page 1of 4

YE - PARCO 100 ppm.

xls

Table 1 – Feedstock Specification


SRGO LVGO BLEND
Feed Rate BPSD 24000 2000 26000
m3/h 159.0 13.3 172.3
t/h 134.9 11.9 146.8
Specific Gravity g/ml 0.849 0.896 0.852
Sulfur wt% 1.22 2.15 1.30
Total Nitrogen ppmwt 138 400 159
Bromine Number g/100g 0.5 0.5 0.5
Total Aromatics vol% 21.7 31.0
Total Aromatics wt% 28.1 36.8 28.8
Mono wt% 18.4 18.0 18.4
Di wt% 8.2 13.4 8.6
Tri(+) wt% 1.4 5.4 1.8
Cetane Index D976 52 45 52
Distillation [LV-%] ASTM D86 D86 D86
1 °C 248 291 248
5 °C 257 308 256
10 °C 262 317 264
20 °C 269 325 272
30 °C 276 332 279
50 °C 290 345 294
70 °C 309 358 314
80 °C 321 365 326
90 °C 336 375 341
95 °C 347 384 353
99 °C 354 390 364

Table 2 – Operating Conditions


SOR EOR
Main Catalyst LHSV 1/h 1.09 1.09
Bed 1 Inlet Temperature °C 326 384
Bed 1 Outlet Temperature °C 341 395
Bed 2 Inlet Temperature °C 331 388
Bed 2 Outlet Temperature °C 341 395
Bed 3 Inlet Temperature °C 335 394
Bed 3 Outlet Temperature °C 341 395
Temperature Rise °C 31 18
WABT °C 337 393

Recycle Gas H2 Purity (before MUG addition) vol% 72 72


Recycle Gas H2S Content vol% 0 0
Makeup Gas H2 Purity vol% 82 82
Makeup Gas H2S Content vol% 0 0
HP Loop Pressure Profile
Reactor Inlet Pressure barg 51.9 53.0
Reactor Pressure Drop (clean) bar 3.6 4.7
Reactor Outlet barg 48.3 48.3
CHPS barg 44.9 44.9
Hydrogen/Oil Ratios
Reactor Inlet Nm3/m3 150 186
Quench 1 Nm3/m3 55 35
Quench 2 Nm3/m3 40 5
Total Hydrogen/Oil Ratio Nm3/m3 245 226
Recycle Gas Scrubber Yes
Hot Separator No
Guaranteed Catalyst Cycle Length months 36
YE - PARCO 100 ppm.xls

Table 3 – Hydrogen Consumption and Yields


SOR EOR
IN:
Feed wt% 100.00 100.00
Chemical H2 Consumption wt% 0.49 0.36
Chemical H2 Consumption Nm3/m3 47 34
OUT:
H2S wt% 1.37 1.37
NH3 wt% 0.017 0.019
C1 wt% 0.015 0.053
C2 wt% 0.016 0.057
C3 wt% 0.015 0.049
C4 wt% 0.013 0.042
Naphtha (C5-150°C) wt% 0.56 1.21
Diesel (150°C+) wt% 98.50 97.56
Total 100.49 100.36

Table 4 – Estimated Stripper Product Properties


SOR EOR
Naphtha
Density @ 15°C g/ml 0.67 0.68
Sulfur ppmwt <5 < 10
Nitrogen ppmwt <5 <5
Distillation [LV-%] D86 D86
1 °C 35 31
5 °C 36 32
10 °C 38 33
20 °C 44 36
30 °C 52 42
50 °C 67 58
70 °C 81 76
80 °C 89 85
90 °C 98 96
95 °C 108 107
99 °C 120 119
Diesel
Density @ 15°C g/ml 0.839 0.843
Sulfur ppmwt 100 100
Nitrogen ppmwt < 50 < 50
Cetane Index D976 55 54
Flashpoint (Nelson Method) °C 84 77
Polyaromatics wt% 3 7
Distillation [LV-%] D86 D86
1 °C 196 177
5 °C 238 231
10 °C 259 257
20 °C 268 266
30 °C 275 274
50 °C 291 289
70 °C 311 309
80 °C 324 323
90 °C 339 338
95 °C 352 351
99 °C 364 363
YE - PARCO 100 ppm.xls

Table 5 – Catalyst Requirements per Reactor


Reactor Dimensions
Inside Diameter, mm mm 3300
Number of Reactors 1
Number of Beds 3
Number of Quench Sections 2
Catalyst Bed Distribution Catalyst Catalyst Loading Bed Length Volume Catalyst Weight
Type Size/ Shape Method mm m3 kg
Bed 1 KG 55 3/4" Pentaring Sock 200 1.71 1505
KF 542-9R 9 mm Ring Sock 200 1.71 941
KF 542-5R 6 mm Ring Sock 300 2.57 1527
KF 841-3Q 2.8 mm 4-Lobe Sock 1000 8.6 5431
KF 757-1.5E 1.3 mm Cylinder Dense 2500 21.38 16999
KF 841-3Q 2.8 mm 4-Lobe Sock 150 1.28 815
1/4 inch inert balls Sock 150 1.28 1850
Bed 2 1/4 inch inert balls Sock 150 1.28 1850
KF 757-1.5E 1.3 mm Cylinder Dense 8000 68.4 54397
KF 841-3Q 2.8 mm 4-Lobe Sock 150 1.28 815
1/4 inch inert balls Sock 150 1.28 1850
Bed 3 1/4 inch inert balls Sock 150 1.28 1850
KF 757-1.5E 1.3 mm Cylinder Dense 8000 68.4 54397
KF 841-3Q 2.8 mm 4-Lobe Sock 150 1.28 815
1/4 inch inert balls Sock 150 1.28 1850
1/2 inch inert balls Sock 150 1.28 1778
1 inch inert balls Sock To fill remainder of bottom head
Total 21550 184 148669