You are on page 1of 11

Volare™ GC is our newly launched laboratory GC model that

provides EXCELLENT PERFORMANCE, EASY OPERATION, and GREAT

FLEXIBILITY for our customers at AFFORDABLE PRICES.

 Precise oven temperature control & multiple independent auxiliary heating zones

 Fully Electronic Flow Control with temperature compensation technology ensure

excellent accuracy, stability & repeatability in flow rate & hence satisfying

analysis performance is guaranteed

 User friendly PC software control features plus separate keypad/touchpad control of

GC & autosampler gives better user experience in their routine lab works

 Versatile injectors, detectors and valve systems further extend the GC capabilities,

which exceed customers’ requirements in most of their applications nowadays

MAGENTA LABSCIENCE PTE. LTD.


Address: 21 Jalan Raja Udang, the Arte 16-02, Singapore 329215 Telephone: +65 8163 6772; Email: sales@magenta-labscience.com
The Specification Sheet of Volare™ GC
Column Oven
Standard: Ambient + 4 ℃~ 450 ℃
Temp. Range: Liquid Nitrogen Trap: -80 ℃~ 450 ℃
Dry Ice Trap: -55 ℃~ 450 ℃
Temp. Ramp Rate: Min.: 0.01℃/min; Max.: 120℃/min;
Temp. Accuracy: ≤1 ℃
Temp. Stability: ≤ 0.5%
Temp. Programs: 6 oven ramps & 7 plateaus (allows negative ramps)
Program Time: 999.99 mins at Max.
Internal Dimension: 28 x 30 x 18 cm
Auxiliary Heating Zones (exclude main column oven)
Heating Zones: Independent control over 6 heating zones
Temperature: 350℃ at Max.
Others: For valve oven, FPD aux heating, & 2nd small column oven

Injectors (Dual Injector Channels capable)


Split/Splitless Packed Septum Temp. Program Volatile Series
Injectors Type:
Capillary Inlet Purge Injection Cool on Column Inlet

Max. Temp.: 400℃ 400℃ 450℃ 400℃

Pneumatic Control: EFC/EPC EFC/EPC EFC/EPC EFC/EPC

Pressure Range: 0-100psi 0-100psi 0-100psi 0-100psi

Pressure Accuracy: 0.01psi 0.01psi 0.01psi 0.01psi

0-1000ml/min (He) 0-1000ml/min


Flow Rate Range: 0-100ml/min N/A
0-200ml/min (N2) (He or H2)

Flow Rate Accuracy: 0.1ml/min 0.1ml/min N/A 0.1ml/min

Fits 1/4 & 1/8 inch Direct on cool Inert flow path,
Max. Split Ratio 1:7500 packed columns; column injection minimum
Others:
(He, N2) Fits 0.53/ 0.32mm ensure complete volatile
Capillary columns sample transfer adsorption

MAGENTA LABSCIENCE PTE. LTD.


Address: 21 Jalan Raja Udang, the Arte 16-02, Singapore 329215 Telephone: +65 8163 6772; Email: sales@magenta-labscience.com
Detectors (Dual Detector Channels capable)
Sensitivity/ Flow Temp. Dynamic Sampling
Type: MDL Others
Selectivity Control Max. Range rate
For most organic
≤ 2.5 pg of Carbon/s 107 0.1 ~ 200
FID: EFC compounds; fit capillary 450℃
(C16, hexadecane) (±10%) Hz
or packed columns

Signal ≤ 400 pg/ml Extreme Small Dead


105 0.1 ~ 200
TCD: ≥ 2500 (propane, EFC Volume 35uL; Unique 400℃
(±10%) Hz
mV.mL/mg He carrier) single filament design

150uL micro cell;


≤0.009 pg/mL (~9 fg/ml) 0.1 ~ 200
μ-ECD: EFC 5% Methane /Ar(N2) as 400℃ >5*105
(Lindane, γ-HCH) Hz
make-up gas
P: ≤0.2 pg/s
6
10 gP/gC (Parathion EFC P: >104
Sensitive to sulfur &
Methyl) 0.1 ~ 200
FPD: phosphorus-containing 350℃
S: ≤20 pg/s Hz
compounds
105 gS/gC (Parathion EFC S: >103
Methyl)
PDHID:
To Be Advised upon Order
PID:

Autosampler
22 positions in total;
19 for sample vial (upgradable to 150 positions)
Sample Vials:
2 for solvent vial (upgradable to 11 positions)
1 for waste vial (upgradable to 5 positions)
Volume: 0.1uL ~ 250 uL; Precision ≤ 1% RSD;
Injection Performance:
Support dual sampler tower injection; fully automatic control via user
Others: defined programs; pre & post injection wash settable; etc.

General
Electrical power supply: 120/200/220/230/240 VAC ± 5%
3 channel auxiliary (pressure control mode)
Auxiliary EPC: Dual channel auxiliary (pressure control mode)
Single channel auxiliary (pressure control mode)
Pneumatic Control Modules: Flow/Pressure control mode; Temperature Compensation; etc.

Communication: Ethernet communication; Remote control possible;

Software Control: ChemLab (English) with intelligent peak integration feature

MAGENTA LABSCIENCE PTE. LTD.


Address: 21 Jalan Raja Udang, the Arte 16-02, Singapore 329215 Telephone: +65 8163 6772; Email: sales@magenta-labscience.com
Highly Accurate EFC modules
(Electronic Flow Control)
 Temperature compensation features built-in

 Micro proportional valve & pressure/flow sensor

 Hydrogen leak detection & auto-shut down protection

 Accurate pressure control mode (down to 0.01 psi precision)

 Injector EFC (Electronic Flow/Pressure Control Modes)

 Detector EFC (Electronic Flow Control Mode)

MAGENTA LABSCIENCE PTE. LTD.


Address: 21 Jalan Raja Udang, the Arte 16-02, Singapore 329215 Telephone: +65 8163 6772; Email: sales@magenta-labscience.com
Versatile Injectors modules

 S/SL Injectors, Packed Column Inlets with septum purge, Programmable

Temperature Cold on Column Inlets, Volatile Inlets at your choices

 Support dual injector channels + dual detector channels

 Fits packed columns & capillary columns

Column Oven & Auxiliary Heating Zones

 S/SL Injectors, Packed Column Inlets, Programmable Temperature Cold on

Column Inlets, Volatile Inlets at your choices

 Up to 6 auxiliary heating zones extends the possibilities of valve systems

(up to 8 switching valves) for specific GC analyzer solutions

MAGENTA LABSCIENCE PTE. LTD.


Address: 21 Jalan Raja Udang, the Arte 16-02, Singapore 329215 Telephone: +65 8163 6772; Email: sales@magenta-labscience.com
Autosampler
 Fully PC control & Touch Pad control, Extreme User Friendly Interface

 USB port available for direct host PC program control

 Modbus communication protocol provided for control program development

 Precision Motor driven; reliable sample injection

 19 sample vial positions as standard


- Upgradable to 150 positions

 2 solvent/cleaning position

- Upgradable to 11 positions

 1 waste position as standard

- Upgradable to 5 positions

ChemLAB PC Software Control


 Fully control & setting of GC & modules through Ethernet communication

 Real Time display of GC status & detector channels

 Intelligent peak retention time identification with simple double click on the chromatograph

 User friendly analysis features such as quick chromatogram comparison, advanced reporting,
etc.

 Fully support GLP / FDA- 21 CFR Part 11 compliance, IQ/OQ & System Suitability Test, etc.
Best fit in Pharma, Accredited 3rd party testing laboratory & industrial QC laboratories, etc.

 Autosampler sequence handling, automatic peak integration, & quick report generating
guarantee user highly efficient routine lab works.

MAGENTA LABSCIENCE PTE. LTD.


Address: 21 Jalan Raja Udang, the Arte 16-02, Singapore 329215 Telephone: +65 8163 6772; Email: sales@magenta-labscience.com
GC Detectors

Flame Ionization Detector(FID)

 Extended dynamic range (107)

 Automatic flame igniting

 Hydrogen leakage protection

Thermal Conductivity Detector(TCD)

 Suitable for packed column and capillary column

 Micro-cell & minimum dead volume improved


sensitivity

 Single filament design, more tolerate to smallest


temperature fluctuation

Electron Capture Detector (ECD)

 Micro-cell design, extremely high sensitivity

 Anode-purged system keeps ECD clean

Flame Photometric Detector(FPD)

 PMT protected by Special cooling system

 No sample will absorb on FPD’s surface by


inert pipe

MAGENTA LABSCIENCE PTE. LTD.


Address: 21 Jalan Raja Udang, the Arte 16-02, Singapore 329215 Telephone: +65 8163 6772; Email: sales@magenta-labscience.com
Application—TVOC
Analyzer Description

Configuration:

GC + S/SL+TVOC column + FID

Sample type:

Air

Compounds analyzed:

Volatile organic compounds

MAGENTA LABSCIENCE PTE. LTD.


Address: 21 Jalan Raja Udang, the Arte 16-02, Singapore 329215 Telephone: +65 8163 6772; Email: sales@magenta-labscience.com
Application—Permanent Gas

Analyzer Description

Configuration:

GC + PP+ packed column+ TCD

Sample type:

Nature Gas

Compounds analyzed:

Permanent Gas

MAGENTA LABSCIENCE PTE. LTD.


Address: 21 Jalan Raja Udang, the Arte 16-02, Singapore 329215 Telephone: +65 8163 6772; Email: sales@magenta-labscience.com
Application—Organochlorine Pesticide

Analyzer Description

Configuration:

GC + S/SL+ capillary column+ ECD

Sample type:

Vegetable and fruit

Compounds analyzed:

Organochlorine Pesticide

MAGENTA LABSCIENCE PTE. LTD.


Address: 21 Jalan Raja Udang, the Arte 16-02, Singapore 329215 Telephone: +65 8163 6772; Email: sales@magenta-labscience.com
Application—Organophosphorus Pesticide

Analyzer Description

Configuration:

GC + S/SL+ capillary column+ PFD

Sample type:

Vegetable and fruit

Compounds analyzed:

Organophosphorus Pesticide

Check with us for more & specific GC applications!

 sales@magenta-labscience.com