USER MANUAL
DescriPTION Pag. 5
INSTALLATION Pag. 8
Troubleshooting Pag. 17
APPENDIX 1 Pag. 18
APPENDIX 2 Pag. 19
Notes on the use of product For safe and efficient use of the product, please read carefully the following
instructions before starting any operation.
Any use of the product other than the one described in this manual shall be considered the
user’s full responsibility.
The same applies for any unauthorized modifications.
In addition to the hereby listed standards, the user must comply with the provisions of the
current legislation regarding personal safety and health together with all other persons in the
workplace.
SISGEO is not responsible for any accident, breakdown or other problems due to lack of
knowledge and / or non-compliance with the requirements contained in this manual.
Check that the product has not been damaged during the transport.
Verify that the package includes all items as well as any requested optional accessories; if
anything is missing, please promptly contact SISGEO.
The user must strictly follow all the operations described in this manual.
Maintenance or repair of the device is permitted only by authorized operators.
These operators must be physically and intellectually suitable.
For information about instrument or to order spare parts, always specify the product
information which can be found on the identification label.
When replacing parts, always use ORIGINAL SPARE PARTS.
The manufacturer reserves the right to make either technical and / or commercial changes
without prior notice.
It is our policy to keep manuals continuously updated.
Symbols
Note The present Manual is issued by SISGEO in English Language and translated in other
different languages.
In order to avoid discrepancies and disagreements on the interpretation of the meanings,
Sisgeo Srl declares that English Language prevails
INTRODUCTION
Unit of measurement:
the standard output is sinα. Upon request is possible
5
to configure IPI with sinα with K≠1 or another unit of
measurement ( °, mm/m, inch/feet).
Inclinometer’s casing grooves, once installed, are identified with numbers 1-2-3-4,
clockwise; the groove nr. 1 is the one closer to geographic north or the one turned towards
the expected movement.
Model, serial number and “A” are marked on the reference side.
The pictures below shows the sign’s convention:
B- B+
reference
wheels A-
PRELIMINARY Before starting the installation we recommend to check the instrument connecting to a
INSTALLATION The inclinometer casing must be already installed and the grouting must be cured.
DIGITAL IPI
Rod
termination
resistor
Identify the IPI according to the project Using a strong rod (not supplied), hang
scheme. Insert the bottom IPI into the the IPI.
casing, checking that reference wheels
are in groove 1. The IPI must have the
termination resistor; be sure it doesn’t
touch the bottom.
calibrated pin
Connect the second IPI with the To obtain a correct connection align
calibrated pin. Remove the red cap from the references. Do not strain or screw
connectors and join them carefully.Fix tightly to avoid damaging the connectors.
them with wrappers or tape. Slide the IPI Protection IP68 (1MPa) is guaranteed only
into the casing respecting the reference with a good connection.
wheel groove 1.
Stainless steel
Note: in case of re-installation check
wire Ø2.5 mm
the screws of the wheels and tighten if
necessary.
plate
Block the cable with the plate on the Installation example using a measuring
terminal cap. Protect the cable from panel for SISGEO portable datalogger
mechanical damage and the end side from (i.e. New Leonardo).
the water.
Installation scheme
example
IPI
IPI
bottom detail
IPI
~ 1m
Termination resistor
ANALOG INCLINOMETERS
suspension pin
steel clamps
steel wire
Ø 2mm
Cut the steel wire about 5/10cm longer Insert the IPI into the casing. The
than necessary. Following the draw, reference wheels must be in groove 1.
assemble the IPI to the suspension pin. Using the steel wire, lower carefully the
IPI into the casing.
plate
Insert the suspension pin into one of the If the IPI quantity should make the
protective cap holes. Identify the IPIs. installation difficult, connect them outside
Block the cable with the plates of the the casing like a chain. Fix the cables with
protective cap. Protect the cables from adhesive tape or plastic tie in order to avoid
mechanical damage and the end side from any damage during installation. Keep the
water. cable a little longer then the steel wire
between two IPI, to avoid ripping it when in
traction. If the total weight would be higher
than 30 kg, we recommend to use copper
clamps and the suitable plier.
TAKING The last digital IPI of every chain must have a termination resistance as follows:
MEASUREMENTS
Chains (to a single datalogger) Resistance
1 120Ω
2 240Ω
3 360Ω
4 480Ω
Manual readings are taken connecting the conductors to a readout according to the following
scheme:
Red + Loop
Black - Loop
Mono axial IPI 4-20mA
White Thermistor
current loop
Green Thermistor
Shield Shield
Blue Thermistor
Shield Shield
To obtain reliable measures, with 4-20mA IPI, we recommend a warm up time not less
than 10 seconds.
Digital IPI suggests to program the Modbus master (if not supplied from SISGEO) to wait
the third reading before to consider it valid.
Readings are taken connecting the cable to a portable readout with RS485 interface (DCE,
Half duplex, no Echo) able to manage communication protocol SISGEO Modbus RTU.
The power [W] of power supply must be chosen according to the IPI quantity and power
supply mode.
Communication protocol is downloadable from Sisgeo Website (to be used when MODBUS
Master is not supplied by SISGEO).
Sisgeo suggests not to change the parameters set in factory (serial number, calibration
factors etc.).
The Modbus master (readout unit) must be set according to the factory’s IPI configuration.
DATA MANAGEMENT The following formulas allow to convert the electric measurements into engineering values:
∆I = Li - L0
L0 = Zero reading
Li = Excercise reading
Zero reading shall be taken carefully once the installation is performed and the system is
stable (no vibrations etc...).
Usually a complete stabilization of the system takes 36/48 hours.
We suggest to consider only the relative and not the absolute measurements.
Example
Using:
Linear factor (L1-L0)/S : (17.006 – 12.965)/46.29078 = 0.0873 [sinα]
Polynomial factor
[(L13 x A)+(L12x B)+(L1 x C)+D] – [(L03 x A)+(L02x B)+(L0 x C)+D] =
= 0.08742 – (-0.0000352) = 0.08746[sinα]
The local displacement, where the IPI is installed and determined by the wheels assembly
distance, is obtained using the following formula:
Dai = P x sinα
Dbi = P x sinβ
Da
Di P = Wheels step
Db
β
α
It is possible to identify biaxial IPI azimuth following the scheme below (sinα/sinβ) :
A; sinα
+/+
+/-
θr
sinα sinβ k
+ + 0
B; sinβ
+ - ½
- - ½
-/- -/+
- + 1
Using readout units, temperature will be displayed directly in °C ; if the resistance value is
read, the conversion formula or the table in Appendix 1 can be used.
Measure 0mA
Cable cut / damaged Repair the cable. Cable splicing kit available at Sisgeo.
Measure overrange
Digital IPI
master
Verify the correct power and power supply sccording to the IPIs
Wrong IPI power supply
number
master Check the IPI with a SISGEO portable datalogger. Contact SISGEO
Electronic board problems
assistance for replacement if problem persist.
not be read by Modbus Short circuit Check the fuse on the wiring clamps. If it is burned check the cause.
master
doesn’t read the last Voltage drop too high Split in more than one chain to limit cable lenght
MAINTENANCE After-sales assistance for calibrations, maintenance and repairs, is performed by SISGEO’s
SERVICE service department.
The authorization for shipment shall be activated by RMA “Return Manufacturer
Authorization”. Create your account and then fill in the RMA module clicking on:
http://www.sisgeo.com/repairs.html
Send back the instrument/equipment with the complete accessories, using suitable
packaging, or, even better, the original ones.
The shipping costs shall be covered by the sender.
SISGEO S.r.l.
Via F.Serpero, 4/F1
20060 MASATE (MI)
1
T= -273.2
A + B ( LnR ) + C ( LnR )3
Where:
T= temperature in °C
LnR= natural Log of the thermistor resistance
A= 1.4051x10-3 (coefficents calculated over the -50° to +70°C span)
B= 2.369x10-4
C=1.019x10-7
525.4 70
Plier for copper clamps mm 2, 2.5, 3. Use only for supplied copper clamps.