Anchorage design is assessed according to ACI 318 Appendix D which is exclusively based on the

strength approach (LRFD). Please follow the LRFD guidelines to assess the anchorage
Ft
Utt = Rnt
= 0.0 %
min( Ω
,ϕNcb )
where:
Rnt
Ω
= 77.2 kN Tension resistance


Uts = min(Rnv ,Rnb )
= 0.0 %
where:
Rnv
Ω
= 45.2 kN Shear resistance

Rnb = 1.2lc tFu ≤ 2.4dtFu


Rnb = 0.0 kN
where:
Fu = 0.0 MPa Specified minimum tensile strength of the connected material

lc = 0 mm Clear distance, in the direction of the force, between the edge of the hole and the edge of the adjacent hole or edge of the material

t= 0 mm Thickness of connected material

d= 0 mm Nominal diameter of the fastener

Ω= 2.00 Safety factor

ϕNcb = ϕψ3 24√fc′ h1.5


A
ef A
N
= 0.0 kN
No
where:
AN = 0 mm2 Concrete breakout cone area for group

ANo = 0 mm2 Concrete breakout cone area for single anchor

fc′ = 0.0 MPa Concrete compressive strength

ψ3 = 1.00

hef = 0 mm Depth of embedment

ϕ= 0.00 Resistance factor

A
ϕVcbg = ϕ A v ψ5 ψ6 ψ7 Vb = 0.0 kN
vo

Vb = 7( dl )0.2 √d0 √fc′ c1 1.5 = 0.0 kN


0
where:
Av = 0 mm2 The total breakout shear area for a single anchor

Avo = 0 mm2 The area of the full shear cone

ψ5 = 1.00

ψ6 = 1.00

ψ7 = 1.00 A modifier to reflect the capacity reduction when side cover limits the size of the breakout cone

c1 = 0 mm The edge distance in the direction of load

fc′ = 0.0 MPa Concrete compressive strength

15/10/2019 16:50:19 p. m. 1/2


l= 0 mm The embedment depth

d0 = 0 mm The rod diameter

ϕ= 0.00 Resistance factor

15/10/2019 16:50:19 p. m. 2/2