STABILIZED SWITCHING SUPPLY SOURCES

SPIN

INSTRUCTION MANUAL

Address: UTE d.o.o.


ULJANIK TESU ELEKTRONIKA
Flaciusova 1
52100 PULA
REPUBLIC of CROATIA

Phone: +385 (52) 38 53 50

Fax: +385 (52) 38 53 51

E-mail ute@pu.hinet.hr

Cat. N°.: ŽD161298E.2 Page 1 (1)


SPIN

APPLICATION:

SPIN - *** - ** - ** is a range of stabilized switching supply sources intended for:


- consumers supply,
- storage batteries charging / maintenance,
- simultaneous storage battery charging / maintenance and consumers supply.

Rectifiers voltages are adjusted to operate with LEAD batteries.

BRIEF DESCRIPTION:

The switching supply sources feature high degree of efficiency and small
dimensions and weight.
The electronic current limit makes them insensitive to overloads and short -
circuits at output terminals.

The SPIN rectifiers can be supplied by:


- single-phase 220 or 440 V,
- three-phase 3x380 V (with neutral) or
-3x440 V (without neutral).
It is only necessary to correctly connect the supply cable for the device to operate
trouble free, without any cross-connecting or adjustment inside device.

It is recommended to use a three-phase supply when possible.

The SPIN rectifiers are available in several types, depending on output voltage and
current (power), and in two basic versions:

Version - N: - without own on / off switch


- constant output voltage and
- with LED indication of voltage: - undervoltage,
(only for version SPIN-300-**-N) - normal voltage and
- overvoltage.

Version - LX: - with own on / off switch,


- with switch for 2 levels of output voltage: - normal voltage and
- boost - rapid charging,
- with LED indication of voltage: - undervoltage,
- normal voltage and
- overvoltage,
- built-in voltmeter and ammeter.

Several rectifiers of SPIN type (of same output voltage) can be parallel connected to
increase the output power / current rating.

TECHNICAL DATA:

Cat. N°.: ŽD161298E.2 File:SPIN e knjiga uputa.doc Page 2 (2)


SPIN

Input voltage (45 - 100 Hz) 1 x 220 V


or 1 x 440 V
or 3 x 380 V (with neutral)
or 3 x 440 V (without neutral)

Output voltage :

Rated voltage 12 V: - normal operation 13.5 V


- boost 14.5 V

Rated voltage 24 V: - normal operation 27 V


- boost 28. 8 V

Output current see table

Short - circuit current approx. 1.5 x Inom


Output voltage accuracy +1%

Output voltage ripple <1%

Efficiency (at Inom) > 83 %

Consumption on supply switched off


(from storage battery) < 15 mA (SPIN-150)
< 30 mA (SPIN-300)

Operating (ambient) temperature range -10 to + 50 °C

Mechanical protection I P 21

Dimensions and weight see table

Mounting on the wall

Cooling natural air circulation

TABLE OF STANDARD TYPES:

Type Volt. Current Volt. Volt. Height Width Depth Weight


nom. nom. nom. boost (mm) (mm) (mm) (kg)
SPIN-300-24-LX 24 V 12 A 27 V 28.8 V 180 200 120 2.7
SPIN-300-24-N 24 V 12 A 27 V - 180 200 120 2.2
SPIN-300-24-N/K 24V 12 A 27 V - 370 300 300 10.0
SPIN-150-24-N 24 V 6A 27 V - 180 110 85 1.2
SPIN-300-12-LX 12 V 24 A 13.5 V 14.5 V 180 200 120 2.7
SPIN-300-12-N 12 V 24 A 13.5 V - 180 200 120 2.2
SPIN-150-12-N 12 V 12 A 13.5 V - 180 110 85 1.2

Cat. N°.: ŽD161298E.2 File:SPIN e knjiga uputa.doc Page 3 (3)


SPIN

CONNECTION:
The rectifiers are supplied with minimum 1.5 meter long connection cables.
The input cable is a five-core color marked leads cable:
Connection of supply cables:

black 440 V black


Phase black black
220 V brown do not connect brown
Neutral blue blue
grounding yellow-green grounding yellow-green

L3 black L3 black
L2 black L2 black
3x380V L1 brown L1 brown
Neutral blue do not connect blue
grounding yellow-green grounding yellow-green

The output cable is two-wire, red lead is + pole and black is – pole.

It is recommended to shorten the output cable to necessary length in order to


decrease voltage drops. If available length is not sufficient the customer is to extend
the cable by appropriate connections terminals taking care of cable cross-section i. e.
voltage drop resulting from additional cable.

NOTE:
If 12 V rectifier is used for storage battery charging it is necessary to connect in
output cable a fast fuse for the rectifier rated current . This fuse is not a protection
against overload or short-circuit since the rectifier is already protected with electronic
current limit but it is necessary for protection against possible poles reversing
which would otherwise result in rectifier damage.

The rectifiers with output voltage of 24 V are already equipped with this fuse.
Therefore, there is no need for its external mounting.

MOUNTING:

The rectifiers are foreseen for wall mounting. It is necessary to enable a natural
circulation of air i. e. around the rectifier a space of about 10 cm should be free.
If the rectifier is to be built in a closed cabinet the temperature inside the
cabinet should not exceed 50 °C and it would also be good to have, in this case, a fan
for an intensive air circulation inside the cabinet.

Cat. N°.: ŽD161298E.2 File:SPIN e knjiga uputa.doc Page 4 (4)


SPIN

180

140
max. 120 200
Dimension drawing
SPIN-300-**-LX

180

140
max. 120 200
Dimension drawing
SPIN-300-**-N

180

85
70
Dimension drawing
SPIN-150-**-N

Cat. N°.: ŽD161298E.2 File:SPIN e knjiga uputa.doc Page 5 (5)


SPIN

300
300

09

V A

370
400 b1

h1

A203

345
250

Dimension drawing
SPIN-300-**-N/K

Electric connection
SPIN-300-**-N/K

Cat. N°.: ŽD161298E.2 File:SPIN e knjiga uputa.doc Page 6 (6)

You might also like