You are on page 1of 2

1 Connec ng Connec ng

Connect devices 3 Power 5 LED descriptions


I/O - signals external devices

Connect 9-24 VDC to pin +Vdc


Connect Ground to pin GND

Choose RS232
serial interface

RS485

For EC220 I/O signals-


See sec on “A” on
reverse side before
proceeding to the next
step.

LED Name Color Function


Power OFF No power
Power up the module! 9-24 VDC Green Power on
See sec on C See sec on E Only! Status OFF Normal
Red See step 4
Running OFF or ON Not running
Flashing Normal / Running
GSM Signal Green See step 4
Go to step 2
Go to step 4
Note! Before using the unit, follow all the steps. Note! Before using the unit, follow all the steps.

2 Network connection 4 Status LED


1. Ensure that PIN code security is disabled!
Connect
2. Power up the unit.
to GPRS 3. Check that the GSM Signal LED shows green (see table below).
network! 4. Go to secƟon B to finish the configuraƟon on www.netbiter.net.

GPRS

Status LED indicaƟon DescripƟon and acƟons


The unit is opera ng in normal mode.
If not using a Netbiter SIM card: make sure Normal
that the SIM card has a mobile data plan and Verify that the SIM card is properly installed and that PIN code security is disabled.
allows text messaging, and that PIN code Not registered on home network If this state persists, there is no signal for the GPRS network.

messages
security has been disabled.

Status
To disable the PIN code security, insert the No APN
SIM card into a regular phone and follow the Problem with Network se ngs Missing APN (Access Point Name) for the EC220. The APN must be set from
instruc ons provided by the manufacturer. Netbiter Argos. See sec on C for instruc ons.
Insert the SIM card at the bo om of the
Netbiter EasyConnect EC220. The SIM card The EC220 has no connec on to netbiter.net.
should be placed as shown in the illustra on. No connec on to Netbiter Argos Check that the APN is correct. See sec on C for instruc ons.
To complete the GPRS setup, the unit must be
Mount the antenna ac vated at www.netbiter.net.
(SMA connector) and Ensure that the antenna is correctly mounted and poin ng upwards. Use another external
insert the SIM card. Low signal antenna or try to move the antenna using extension cables.
signal
GSM

Try different antenna placements to improve recep on.


Medium signal
This indicates an op mal setup.
Good signal
Go to step 3
Note! Before using the unit, follow all the steps.
A B D
Example of input wiring diagrams Activate the Netbiter gateway Technical details
The Netbiter gateway must be ac vated before it can communicate with Netbiter
Analog output
EasyConnect EC220
Argos. To complete this procedure, the System ID and AcƟvaƟon Code are Power Supply
Analog load 0-10 V 9-24 VDC (2 W)
required. These provided on a printed Netbiter Argos informa on sheet, supplied
Max load resistance 2 kΩ
with the Netbiter gateway. Temperature range

Installation Guide
AO: OUT Opera ng: -30 °C to +65 °C
Storage: -40 °C to +80 °C
AO: COM To create an account at Netbiter Argos:
Analog output 1. Go to Netbiter Argos (www.netbiter.net) and click on the Create an account MounƟng opƟon Contains FCC ID QIP TC65i

link. Wall moun ng Contains IC 7830A-TC65i

DIN rail (EN 50022), Op onal


Analog input for temperature readings 2. When the new account is created, follow the instruc ons and log in to the new
account. Antenna connector:
PT100
SMA female E325816
AI: AI 1 or AI 2 Default 3. Click on the Online guide icon and follow the instruc ons on how to
se ng Add and acƟvate a system. GSM:
AI: COM Quad band: GSM 850/900/1800/1900MHz
Analog input for temperature reading To use an exisƟng Netbiter Argos account:
(set switch to PT100) 1. Go to Netbiter Argos (www.netbiter.net) and log in to the account. GPRS:
2. Click on the Online guide icon and follow the instruc ons on how to GPRS Class 12
Add and acƟvate a system.
Analog input for voltage readings
0-10 V AI: AI 1 or AI 2 Online Guide
The online guide is accessed by clicking on
AI: COM Check switch the wand in the upper right corner, as
Analog input for voltage reading
(set switch to 0-10 V) se ngs! shown in the image.
Mobile communicaƟon
If mobile communica on is being used:
Analog input for current readings • The phone number for the SIM card is needed.
• The access point name (APN) for the SIM card is needed.
AI: AI 1 or AI 2 Enter a username and password if required by the operator.
• Make sure that the SIM PIN code security is disabled on the SIM card.
AI: COM
Analog input for current reading
(set switch to 0-20 mA) If a Netbiter SIM card is being used, the APN se ngs will be pre-
configured on Netbiter Argos and the PIN code is disabled on delivery.

Relay output The phone number and APN informa on should be supplied with the SIM card. If
not, please contact the operator for the correct informa on. compatible
24 VDC / 34 VAC Relay: NO
0 VDC / 0 VAC Relay: COM SP1537 2.80 2016-10-03
Relay output, must be supplied from an isolated transformer using
a secondary listed fuse rated at max 3.3 A and min. 30 VDC.

C EasyConnect Series Accessories


Digital input
DI: DI 1 or DI 2
Terminal Block
9-24 VDC
DescripƟon
0 VDC Digital input
DI: COM
+Vdc Power 9-24 VDC

GND Power ground


Switch settings AO: OUT Analog out

Switch DescripƟon SpecificaƟon AO: COM Analog output common


PosiƟon Netbiter I/O Extender
AI: AI1 Analog input #1
PT100 Temperature reading -50 - +150 °C Netbiter® I/O Extender series is a collec on of analog and discrete I/O modules with Modbus-RTU protocol
AI: AI2 Analog input #2
(default) using a PT100 sensor communica on.
AI: COM Analog input common
0-20mA Current reading Input resistance: 270 Ω
DI: DI1 Digital input #1 Order Code DescripƟon
0-10V Voltage reading Input resistance: 280 kΩ
DI2 Digital input #2 IOX-DAIO 4DI, 2DO, 2AI, 1AO, 2RTD

IOX-8DIO 8 Digital inputs, 8 Digital outputs


DI: COM Digital input common
HMS Industrial Networks AB
Relay: COM Common IOX-4RO 4 Relay outputs
Box 4126
Relay: NO Normally open connector IOX-6RTD 6 RTD (Pt100/1000, Ni120/1000, Resistance)

IOX-8AIV 8 Analog inputs (voltage)


300 04 Halmstad
Field wiring terminals shall be connected with minimum wire size 24AWG.
IOX-8AIIS 8 Isolated Analog inputs (current) Sweden
The relay output shall be supplied from an isolaƟng transformer having a secondary listed fuse rated max. 3.3
Adc and min 30 Vdc.
Other accessories Phone +46 (0)35 - 17 29 00
Serial Communication Order Code DescripƟon Fax +46 (0)35 - 17 29 09
E-029 Power supply 24VDC (DIN rail mount) E-mail info@hms.se
E-012 Temperature sensor (PT100) Web www.hms-networks.com
E-020 SMA quadband antenna (straight)

E-021 SMA quadband antenna (right angle) Support www.netbiter.com/support


EC220 E-022 SMA quadband antenna SMA (magne c foot)
RS485 (Isolated) Serial port 232 Other E-023 Cable for SMA antenna 3m
device
Pin DescripƟon E-024 Cable for SMA antenna 5m
A RS485 A (+) E-025 Cable for SMA antenna 10m
B RS485 B (-) 1 2 3 4 5 GND Rx Tx
M-008 DIN rail moun ng kit (for metal housing) © 2016 HMS Industrial Networks - All rights reserved - HMS reserves the right to make modifica ons without prior no ce.

COM Common 6 7 8 9
Please check www.netbiter.com for the most updated accessories and other Netbiter products.