Installation:

 Runways must be ± 5mm in a single bay and no more than ±10mm over the
full length of the runway.
 These tolerances must be maintained in four positions: left/right, up/down,
parallel to one another other, and level with one another.

The specifications for runway span are as follows:

 If your span is less than 15m, you are only allowed an overall tolerance of
4mm
 If your span is 15 to 30m, you are allowed 5mm of tolerance,
 For cranes spanning more than 30mt, you are allowed up to 10mm tolerance.