Selection parameters of the indoor units can be found under the chapter Indoor unit details
Selection parameters of the outdoor units can be found under the chapter Outdoor unit details
Only the data published in the data book are correct. This program uses close approximations of these data.
1. Material List
Model Qty Description Material cost Install. cost Subtotal
RXQ8TY1 1 Cooling only VRV IV STANDARD
FXFQ40LUV1 1 VRV FLU - Ceiling Mounted Cassette(Round Flow)
FXMQ50PVE 4 VRV M - Ceiling Mounted Duct
KHRP26A22T 3 Refnet branch piping kit
KHRP26A33T 1 Refnet branch piping kit
DCM601A51 1 intelligent Touch Manager
DMS502B51 1 BACnet Interface-Integrated control system connecting
VRV system with BMS system
BRC1E62 5 Wired Remote Controller (Navigation Remote
Controller)
BYCP125K-W1 1 Decoration panel
R410A 3.3kg Extra refrigerant charge
Piping 6.4 32.5m
Piping 9.5 25.1m
Piping 12.7 32.5m
Piping 15.9 5.0m
Piping 19.1 20.1m
Total cost
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 1
Airflow Supplied airflow
Sound Sound pressure low and high
PS Power supply (voltage and phases)
MCA Minimum Circuit Amps
Fuses Fuses
WxHxD WidthxHeightxDepth
Wght Weight of the device
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 2
3. Outdoor Unit Details
3.1. Table of Abbreviations
Name Logical name of the device
Model Device model name
Tmp C Outdoor temperature in cooling
CC Available cooling capacity
Rq CC Required cooling capacity
Tmp H Outdoor conditions in heating (dry bulb temp. / RH)
HC Available heating capacity (integrated heating capacity)
Rq HC Required heating capacity
Piping Largest distance from indoor unit to outdoor unit
Bse Refr Standard factory refrigerant charge (5m actual piping length)
excluding extra refrigerant charge
For calculation of extra refrigerant charge refer to the databook
Ex Refr Extra refrigerant charge
PS Power supply (voltage and phases)
MCA Minimum Circuit Amps
MFA Maximum Fuse Amps
Run Amps Running Amps
St Curr Starting current
Fuses Fuses
WxHxD WidthxHeightxDepth
Wght Weight of the device
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 3
3.2. Outdoor Details
Name Model Comb Tmp C CC Rq CC Tmp H HC Rq HC Piping
% °C kW kW °C kW kW m
Outdoor 1 RXQ8TY1 120 24.0 22.7 20.8 42.6
Name Model PS MCA MFA Run Amps St Curr Fuses WxHxD Wght
A A A A mm kg
Outdoor 1 RXQ8TY1 400V 3ph 16.1 20 Factory Std 930x1657x765 185
Piping Limitations
Maximum total length 1000.0m
Maximum longest actual length 165.0m
Maximum longest equivalent length 190.0m
Maximum main pipe length (size up of main pipe required if longer) 89.9m
Maximum length first branch to last branch (size up of intermediate pipes required if longer) 40.0m
Maximum length first branch to indoor units 90.0m
Maximum length of indoor units to nearest branch 40.0m
Maximum length difference between longest and shortest distance to indoor units 40.0m
Maximum height difference, outdoor unit below indoor units 50.0m
Maximum height difference between indoor units 30.0m
Connection ratio range 50-130%
Refrigerant pipe diameters 9.5 (liquid) × 19.1 (gas)
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 4
Pipe Capacities
Maximum Connection Index Diameters
149.9 9.5×15.9
199.9 9.5×19.1
> 199.9 9.5×22.2
Main pipe size up 12.7×22.2
4. Piping Diagrams
Pipes marked with * in the diagrams must be connected to the device with a reducing joint.
Ouo o
td
R XQ
r1
T Y
8
1 .5
9
1
m9
3
1
× .1
[]
R P
H
K A3
6
2 T
6 4
.0 m
2
1
. 2
1
× .7
4.1. Piping Outdoor 1
3 .5
[ 2
m ] 3 .5
[ 3
m ] FX
d Q
e
B
M mP
ro
0
5 E
V
4 5m [4
.0 ]
9 .5
1 9
× .1 ×1
.5
9 .
9 9 .5
1 5
× .9
R P
H
K A2
6
2 T K H
2 6
P
R 2 2
A T R P
H
K A2
6
2 T
×1
.4
6 .7
2
m
0
3 6 .4
1
×
2 2
.7
m
5 1 1
×
.4
6 m
0
.7
2 6 .4
1
×
3 2
.7
m
0
Livn go o
R m d ro
e
B m1 B e
ro o
d 2
m d ro
e
B m3
FX Q
L U
0
4 1
V MQ
FX 0 P
5 E
V F XQ5
M VE
P
0 MQ
FX 0 P
5 E
V
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 5
5. Wiring Diagrams
P1P2 = Please select the cable type and size in accordance with the databook.
F1F2 = Please select the cable type and size in accordance with the databook.
O UTF 1,F2
O utdo or1
R XQ8 TY1
IN F1, F2
L1, 2,L3 ,N 1 6A3 ph
Li ving Ro m
F1, 2
F1, 2
F XFQ4 0LU V1
Bed ro m1
F MQX 50P VE
Bed or m2
F MQX 50P EV
P1, 2
BRC 1E6 2
L,N 0.3A 1p h
P1, 2
BRC 1E6 2
L,N 1.6A 1p h
P1, 2
BRC 1E6 2
5.1. Wiring Outdoor 1
F1, 2 ,NL 1.6A p1 h
P1, 2
Bed ro m3 BRC 1E6 2
F MQX 50P VE
F1, 2 L,N 1.6A 1p h
P1, 2
Bed ro m4 BRC 1E6 2
F MQX 50P VE
F1, 2 L,N 1.6A 1p h
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 6
6. Device Options
6.1. Indoor Unit Options
Model Description Used by
BYCP125K-W1 Decoration panel Living Room [FXFQ40LUV1]
7. Centralized Controllers
7.1. Concept
C on tro lG ro up s S pe cif cC on tro le rMo de ls
C on tro lg ro up 1
iT ou ch Man age r
Ou td o r1 (5 ) #i#o ndut odo rsor s51 #c on tro le rs 1
B ac net
#c on tro le rs 1
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 7
7.2. Control group 1
B acnet
DMS 502B 51
1 2
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 8
7.3. Dimensional Drawings
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 9
7.3.1.2. iTouchManager DCM601A51
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.
Page 10