You are on page 1of 13

A system of vertical pipes in a building to which

fire hoses can be attached on each floor, including


a system by which water is made available to the
outlets as needed.
●Standpipe system

Vestibule

Smelting

Sprinklers system

The occupant load for which means of egress shall


be provided for any floor shall be the maximum
numbers of persons intended to occupy that floor
but not less than one person for each ____square
meter gross floor area for detention and
correctional occupancies.
12.2

●11.1

12.1

11.2

As per Fire Code, emergency lighting shall be


arranged to maintain specified level of
illumination in the event of failure of the normal
lighting for a period of at least____hours in
buildings more than 36.5 meters.
●1.5
1.0

3.0

2.0

In building over____storeys above ground level,


areas of refuge shall be provided for occupants of
child day care centers, either by smoke-proof
enclosures or horizontal exits.
●5

Rows of seat between aisles for places of


assembly shall have not more than___seats.
●14

10

12

How much is the Fire Code Construction Tax to be


paid by Mr. Pedro whose building to be erected
costs 500 million pesos as indicated in its bill of
materials?
5 million pesos

500,000 pesos
50 million pesos

●50,000 pesos

High rise buildings are structures or facilities___


in height.
●15 meters

25 meters

20 meters

10 meters

What is the maximum imposable administrative


fines?
100,000 Php

500,000 Php

25,000 Php

●50,000 Php

The type of occupancy that involves hospital.


●Health care

Institutional

Public assembly

Educational

Which of the following is tax-free?


●Church

Hospitals
Park

Schools

Failure to submit fire insurance policy should be


corrected within:
36 hours

12 hours

24 hours

●none of these

For health care facilities, any room or any suite or


room of more than ___ square meters shall have
at least two exit access doors remote from each
other.
92

94

95

●93

For the purposes of determining required exits,


the occupant load of business purposes shall be no
less than one (1) person per ___ square meters of
gross floor area..
●9.3

9.2

9.4
9.1

A type of building where structural elements are


made of wood.
●Type I

Type V

Type III

Type II

Each wet standpipe outlet shall be supplied with a


hose not less than____millimeters in diameter.
●38

34

32

36

Emergency rooms, operating rooms, ICU, delivery


rooms, and other similar facilities shall not be
located more than ____ above or below the floor
of exit discharge.
●1 storey

4 storey

3 storey

2 storey

Bakery is what type of occupancy?


Miscellaneous
●Industrial

Storage

Public assembly

For business occupancies, the clear width of any


corridor or passageway serving an occupant load
of fifty (50) or more shall be not less than___
meters.
●1.12

1.10

1.22

1.21

Occupant load factor for a standing room or


waiting space of a place of assembly (square
meters per person).
0.18

0.48

0.38

●0.28

A continuous passage for the transmission of air.


●Duct system

Ventilation

Curtain board

Damper
The following are factors that affect the degree of
hazard except:
Height of the building

●Age of building

Contents of the buiding

Occupant load

Hotels, dormitories, motels, and single family


dwellings are of what type of occupancy?
Places of assembly

Mixed

Institutional

●Residential

The letters "NO SMOKING" shall be made readable


and recognizable within a minimum distance of
_____meters at any given time, at least 10cm
high preferably with white-colored letters upon a
red background.
●15.25

16.25

18.25

17.25
The number of means of egress from any balcony,
mezzanine, storey, or portion thereof shall not be
less than____.
4

●2

Releasing device shall be bars or panel extending


not less than____of the width of the floor.
1/4

1/2

1/3

●2/3

Which of the following fire is difficult to


extinguish?
Residential fire

●Forest fire

Hospital fire

Structural fire

Each guest room for hotels shall be provided with


a door having a fire protection rating at
least____minutes.
●20
30

60

40

A building is unsafe in case of fire because it will


burn easily or because it lacks adequate exits or
fire escapes.
Fire door

Fire exit

●Fire trap

Fire hazard

All mercantile stores of two hundred seventy-eight


square meters (278 sqm) or less gross area used
for sales purposes on the street floor only.
Class D

Class B

Class A

●Class C

Presidential Proclamation 115-A or the observance


of Fire Prevention Month every_____.
April

February

January

●March
Who among the Fire Marshals cannot impose
fines.
City Fire Marshal

●None of these

Provincial Fire Marshal

Regional Fire Marshal

That portion of an airport where flammable liquids


are stored or dispensed and shall include all
facilities essential thereto, such as underground
tanks from which aircraft fuel and lubricants may
be drawn through dispensing agents.
Storage

●Aircraft service station

Gasoline station

None

Which of the following is commonly used in fire


resistant materials?
●Asbestos

Asphalt

Diamond

Cotton

Dwelling units in row apartments shall be


separated from each other by partition walls
having a fire resistance rating of ____hours. Such
walls shall be constructed solidly and continuously
from the ground to level one meter above the
ridgeline of the roof.
2

●4

The floors of means of egress shall be illuminated


at all points including angles and intersections of
corridors and passageway, landing of stairs, and
exit doors to values of not less than___lux.
9.17

●10.7

11.7

9.07

Any compound mixture which when applied


properly improves the fire resistant quality of
fabrics and other materials.
Pyrolysis

Fumigant

Explosive

●Flame retardant
Wide stairways shall have intermediate handrails
dividing the stairway into portions not more
than____ centimeters in width.
231

213

●223

232

A pre-requisite to grant permits/license by local


government unit for any particular establishment.
Certificate of Recognition

Fire Drill Certificate

Fire Safety Evaluation Certificate

●Fire Safety Inspection Certificate

Who promotes fire safety in the absence of Bureau


of Fire Protection?
Barangay captain

Chief of Police

●Building official

Mayor

Using electrical appliances, which draws electrical


current beyond the designed capacity of the
electrical circuit, is known as?
●Over plugging
Octopus connection

Over capacity

Over loading

You might also like