You are on page 1of 4
Rea & ENGINEERING GROWTH PIONEERING EXCELLENCE Metrological Approvals er Pa) @ EN12480 = OIMLR137 Prenat ey a ~~] Raychem RPG R RRM RPD Meter Working Principle ‘The RAM series type Rotary Gas Flow Meter works on the principle of Positive Displacement. The actual measurement is performed by two oval (8) shaped rotors rotaing within a measurement chamber. During a full revolution ofthe rotors a fixed volume of gas is displaced from the inlet to the outlet ofthe meter. The RRM series Rotary Gas Meter measurement chamber makes the two ovals (8)-shaped rotors to turn, the volume of gas enclosed between the measuring chamber walls and rotors is transported fourtimes in ono complote cycle. The timing goars setthe rotors at an angle cf 90"to each other. The gear train, and the hermetic magnetic coupling, transfers the rotor rotation o the index unt, whichis separated from the pressure tight housing body. The actual volume of gasisindicated onthe mechanical counter. ~U = oe ’ Body Cartridge Cartridge Cover Mechanical Index Counter as a a as as entering into the Rotors are rotating and ‘As Rotor rotates furth With further rotation of body start the Rotors Now are at 30" angle the gas lows to the {o rotate. In this and have captured outlet of the meter. Gas position, gas is specific amount of gas. ‘lowing outs equal o ‘meter Gas flowing out ‘captured @) the volume captured at Is equal tothe volume a the iit. captured atthe inlet. @ ® & EB ava uc ac Raychem RPG's Rotary Gas Meters can be equipped (optional) with two Thermo-wells and two pressure tapping points. Therefore the Rotary Meters can be supplied with an Electronic Volume Conversion Device (EVCD). Refer to the specific brochure for more information about the Raychem’s Electronic Volume Conversion Devices or youmay contactalocal supplier. Ficus eed RM RPD Meters can be used for various non-aggressive gas application. As the meter is based on Positive Displacement Principle, hence itcan be installed without any straight runs and can work at high accuracy in low flow and ‘urbulentflow condition. Some of the gas application and industry applications are mentioned below: TypeofGases_ : Natural gas, Propane, Butane, Air, Hydrogen, Non-aggressive gases, et. Application _: City Gas Distribution, Industrial application, Check Metering, Custody Transfer Forether applications, please contact our sales office. (Eten Type approval MID (110738 RO) Declaration EN12480:2002/A1:2006 Compliance (IML Certificate of Conformity (OIMLATS7-1(2012) Weight & Measurement, India Pressure Equipment Directive (PED) 97/23/EC compliant and IP.67 approved [ATEX : Sensor compliant with Ex ia IIC T4....76 Gb (40°C = Ta +70"C) Encoder compliant with Ex ib IB T3... TS Gb (25°C = Ta +55°C) Ley Flow Range (0.5 - 1000 mh (lower flow up to 0.25 mr available on request) Diameters & End Connection _:DN40 Threaded (BSP) / DN50 — DN160 Flanged: Pressure Rates ‘ANSI 150 - 300, (other on Request) MID Temperature Range (25) °C to (+70) °C (lower temperatures on request) TEX (257°C to (+70PC Large Range rom 1:20 to 1:200 depends on G rating Body ‘Aluminium Shafts ‘Stainless Stee! Impellers ‘Aluminium ‘Gears Dalrin POM Cartridge Aluminium Index Frame Aluminium Timing Gears ‘Steel Bearing ‘Stainless Stee! Dee ec RoUE La Cu Sic RRM series of Rotary Gas Meter is calibrated with air at ero A ‘atmospheric pressure, which is traceable to NMI calibrated references. Ithas been proven — as part of the type approval testing - that the difference between the accuracy at atmospheric ar and at high pressure natural gasis negligible. Accuracy atto@max = #1% or better Accuracy Qmin to Qt : 42% or better Repeatability : Better than 0.1% -_ =a Raychem RPG R eC Uta ae Volumex | GValue | a... 2... at air) | Diameter D | Pp... (bar) | AP* | Basic Transfers** v(m’) (ev'they | (my | (mir) | (mm) (Pa) (rev-mn’?) 0.24973 a6 10 0s 20 | 15"BsP Fa 8 404.3250 io 16 05 og | 15°8sP a 20 404.9250 ais 25 0s 125 | 1.s"BSP Fl 48 404.3250 Gas 40 05 2 4.5" BSP a 120 404.9250 ossess | Gite 25 0.65 1.25 50 21 28 2574.2680 G25 40 065 2 80 a 7 574.2680 G40 65 06s 32 50 21 190 2574.2680 ostosa | Ges 100 1.00 5 80 at 400 1638.1630 1.16028 | Gt00 160 1.00 8 80 21 190 861.8609 1.45036 | Gt60 250 1 125 80 at 635, 699.4840, s.a7tos | 250 400 16 20 100 at 230 318.3520, G400 650 25 32 100 12 607 315.3520 5.15298 | Ges0 1000 6.25 50 150 12 662 194.0625 Voume | t | H | A | B | C Weight = sucun ” [bescinn “adh Rayehem RPG R, Corporate office o2ae73 | 150 | 163 | 156/179 | 93 | 129/140 | 5 RPG House osseas | 171 163 | 240757 | 68 | wveites | 7 483, Dr. Annie Besant Road us a Worl, Mumbai - 400030 ostoas | 171 163 | 2401257 | 240 | azare9 | 7.5 Tel: 91-22-24997485 /6 Fax: 91-22-24938879 1.16028 [171 202 | soajaeo | 92 | 2tvaz8 | 14 Eta raychem@raychemrpg.com 1.45036 | 171/21 | 202 | s7va71 | 118 | 2aeia5s | 15 Marketing Off 31706 | 2aije6o | 208 | se6/a0s | 160 | 226243 | 38 Raychem RPG Pvt. Ltd 5.15298 | 241/260 | 288 [sorta | 01 | 2agiao0 | 48 11" Floor, Vishwadeep Bldg., District Centre, Janak Puri, Delhi - 110058 Dir: 91-11-45789737 Fax: 91-11-2554 6239 Email: prashant_pathak@raychemrpg.com Manufacturing Facility Raychem RPG Pvt. Lia HTS-TRD. WAGHJA Waghjainagar Industilist Association, Chakan, Gat No. 357/97, House no. 94, Knarabwadi - 410501, India Email: krishan_shukla@raychemrpg.com

You might also like