Professional Documents
Culture Documents
COLUMN FOOTING
PARAMETERS
Parameters
Column dimension, b 300.00 mm
Allowable Soil Pressure, qa 150.00 Kpa
Axial Load , P 179.46 KN
Transverse Moment , Mx 64.46 KNm
Longitudinal Moment, My 64.18 KNm
fc' 21.00 Mpa
fy 415.00 Mpa
φ 0.75
Depth from the ground 1.50 m
Rebar, ø 25.00 mm
covering 75.00 mm
λ 1.00
Yc 23.54 KN/m3
Ys 16.50 KN/m3
Moment deduction Factor (Ф) 0.90
ß1 0.85
Initial Dimension :
L 2.1 m
D 0.5 m
d 0.4125 m
qc 125.2485381 KPa
fA 124.03721817 Kpa OK
Vu 158.94621633 KN
Vp 0.0023547588 OK
Steel Requirements :
Mu 12.52485381 Kn*m
Ru 39 kPA
p 0.0001
pmin 0.003
pmax 0.0156686747
puse 0.003
As 2922.2891566 mm2
No. of bars 7
Spacing, s 286.5 mm
say, s = 300 mm
Temperature bars :
At 900 mm
2
Spacing, s 545.41539125 mm
Use s = 450 mm
Development Length :
Ld 825 mm
Required Ld 815.04382003 mm
Use Ld = 750 mm
CF1:
Section
b 1.85 m
h 1.85 m
t 0.5 m
Temperature Bars
db (mm) 20 mm
Spacing (mm) 450 mm
Development length
Ld 750 mm
1.05
1.527525
DESIGN STAIR FOOTI
STAIR FOOTING
PARAMETERS
SOLUTION
D 0.3
d 215
qc 125.138
use B 0.5
Vall 171.847
Mu 0.62569
Ru 88
p 0.0002
pmin 0.003
pmax 0.01567
puse 0.003
As 725.301
No. of bar 4
Spacing, 433.143
say, s = 250
Temperature bars :
At 540
Spacing, s 372.337
Use s 350
Development Length :
Ld 125
SIGN STAIR FOOTING
KN/m
KN/m3
KN/m3
Kpa
KN
Mpa
Mpa
m
mm
mm
mm
footing depth
m
mm
ing Capacity:
Kpa
m
m
m
KN
KN PASSED
m
m
KNm
kPA
mm2
per 1m
mm
mm
mm2
mm
mm
mm
DESIGN OF WALL FOOTING
WALL FOOTING
PARAMETERS
SOLUTION :
D 0.3 m
d 212.5 mm
qc 136.747 Kpa
Vu 126.491 KN
Vall 171.847 KN
Mu 0.3846 KNm
Ru 48 kPA
p 0.0001
pmin 0.003
pmax 0.01567
puse 0.003
As 716.867 mm2
No. of bars 3 per 1m
Spacing, s 684.748 mm
say, s = 450 mm
Temperature bars :
At 540 mm2
Spacing, s 372.337 mm
Use s 350 mm
Development Length :
Ld 100 mm
WALL FOOTING
PASSED
DESIGN OF STAIRS
PARAMETERS
STEEL REINFORCEMENTS
SOLUTION :
Length of stairs 2m
Slab thickness 79.286 mm
d 75 mm
USE : 100 mm
Wu 16.28 KN/m
ρ= 0.0026
ρmin= 0.0051
ρmax= 0.0284
use ρ = 0.0051
As = 381.818 mm2
Spacing = 296.207 mm say S = 250
Max. Spacing = 300 mm
Temperature bars :
As = 200 mm2
Spacing = 392.699 mm say S = 350
Max Spacing = 450 mm
DESIGN OF LANDING
Length : 3m
Width : 1.5 m
Required thickness : 50 mm use t = 100
Wu 10.5 KN/m
d= 94 mm
MOMENT COEFFICIENTS :
@ Negative Moment
32 Cs 0.064
33 Cb 0.036
@ Positive Moment Dead Load
34 Cs 0.035
35 Cb 0.02
@ Positive Moment Live Load
36 Cs 0.04167
37 Cb 0.024
MOMENT LOADS :
@ Negative Moment
Ms 4.545 kN-m
Mb 3.40371 kN-m
@ Positive Moment Dead Load
Ms 0.55705 kN-m
Mb 0.42379 kN-m
@ Positive Moment Live Load
Ms 1.352 kN-m
Mb 1.0368 kN-m
Total + Moments
Ms 2.83166 kN-m
Mb 2.16743 kN-m
REINFORCEMENT REQUIREMENTS
@ Short Direction
-M 4.545 kN-m
w 0.03845
ρ 0.00354
ρmin 0.00614
*use 0.00614
As 491.228 mm2
s 159.885 mm
Use ,s 150 mm
As 491.228 mm2
s 159.885 mm
Use, s 150 mm
@ Discontinuous edge
S 479.654 mm
Smax 300 mm
*Use 300 mm
@ Long Direction
@Continuous Edge
-M 3.40371 kN-m
w 0.03759
ρ 0.00346
ρmin 0.00614
*use 0.00614
As 491.228 mm2
s 159.885 mm
Use, s 150 mm
As 491.228 mm2
s 159.885 mm
Use, s 150 mm
@ Discontinuous edge
S 479.654 mm
Smax 300 mm
*Use 300 mm
TEMPERATURE BARS
*Use 300 mm
*RECOMMENDED 300
mm
mm