COLUMN FOOTING:

COLUMN FOOTING

PARAMETERS
Parameters
Column dimension, b 300.00 mm
Allowable Soil Pressure, qa 150.00 Kpa
Axial Load , P 179.46 KN
Transverse Moment , Mx 64.46 KNm
Longitudinal Moment, My 64.18 KNm
fc' 21.00 Mpa
fy 415.00 Mpa
φ 0.75
Depth from the ground 1.50 m
Rebar, ø 25.00 mm
covering 75.00 mm
λ 1.00
Yc 23.54 KN/m3
Ys 16.50 KN/m3
Moment deduction Factor (Ф) 0.90
ß1 0.85

Initial Dimension :

L 2.1 m
D 0.5 m
d 0.4125 m

Effective Soil Bearing Capacity:

qc 125.2485381 KPa

fA 124.03721817 Kpa OK

Considering Punching Stress:


f1 40.870086922 Kpa
f2 124.03721817 Kpa
f3 40.51766818 Kpa
f4 -42.64946307 Kpa

fave 40.693877551 Kpa

Vu 158.94621633 KN
Vp 0.0023547588 OK

Steel Requirements :

Mu 12.52485381 Kn*m
Ru 39 kPA

p 0.0001
pmin 0.003
pmax 0.0156686747

puse 0.003

As 2922.2891566 mm2
No. of bars 7
Spacing, s 286.5 mm

say, s = 300 mm

Temperature bars :

At 900 mm
2

Spacing, s 545.41539125 mm

Use s = 450 mm

Development Length :
Ld 825 mm
Required Ld 815.04382003 mm

Use Ld = 750 mm

CF1:

Section
b 1.85 m
h 1.85 m
t 0.5 m

Main Reinf. Bars


db (mm) 25 mm
puse 0.003
As (mm2) 2922.29 mm2
Spacing (mm) 300 mm

Temperature Bars
db (mm) 20 mm
Spacing (mm) 450 mm

Development length
Ld 750 mm
1.05
1.527525
DESIGN STAIR FOOTI

STAIR FOOTING

PARAMETERS

Weight of stairs, wu 16.3


Yc 23.544
Ys 16.5
Allowable Soil Pressure, qa 150
Total Axial Load , P 21.3
fc' 21
fy 415
φ 0.75
Depth from the ground 1.5
Main Rebar, ø 20
Temperature bar, ø 16
covering 75
Normal weight concrete, λ 1
Moment deduction Factor ( 0.9
ß1 0.85

SOLUTION

Initial Estimate of footing depth

D 0.3
d 215

Effective Soil Bearing Capacity:

qc 125.138

Dimension of the footing:


B 0.17021
B 0.41257

use B 0.5

Checking for Shear :


Vu 115.753

Vall 171.847

Total thickness of footing : 0.3


Width of footing : 0.5

Mu 0.62569
Ru 88

p 0.0002
pmin 0.003
pmax 0.01567

puse 0.003

As 725.301
No. of bar 4
Spacing, 433.143

say, s = 250

Temperature bars :

At 540
Spacing, s 372.337

Use s 350

Development Length :

Ld 125
SIGN STAIR FOOTING

KN/m
KN/m3
KN/m3
Kpa
KN
Mpa
Mpa

m
mm
mm
mm

footing depth

m
mm

ing Capacity:

Kpa

m
m

m
KN

KN PASSED

m
m

KNm
kPA

mm2
per 1m
mm

mm

mm2
mm

mm

mm
DESIGN OF WALL FOOTING

WALL FOOTING

PARAMETERS

Width of wall , w 0.15 m


Wall height, h 3.4 m
Unit weight masonry 21.2 KN/m3
Yc 23.544 KN/m3
Ys 16.5 KN/m3
Allowable Soil Pressure, qa 150 Kpa
Deadload 10.812 KN/m
Total Axial Load , P 27.03 KN
fc' 21 Mpa
fy 415 Mpa
φ 0.75
Depth from the ground 0.8 m
Main Rebar, ø 25 mm
Temperature bar, ø 16 mm
covering 75 mm
Normal weight concrete, λ 1
Moment deduction Factor (Ф) 0.9
ß1 0.85

SOLUTION :

Initial Estimate of footing depth

D 0.3 m
d 212.5 mm

Effective Soil Bearing Capacity:

qc 136.747 Kpa

Dimension of the footing:


B 0.19766 m
B 0.44459 m
use B 0.5 m

Checking for Shear :

Vu 126.491 KN

Vall 171.847 KN

Total thickness of footing : 0.3 m


Width of footing : 0.5 m

Mu 0.3846 KNm
Ru 48 kPA

p 0.0001
pmin 0.003
pmax 0.01567

puse 0.003

As 716.867 mm2
No. of bars 3 per 1m
Spacing, s 684.748 mm

say, s = 450 mm

Temperature bars :

At 540 mm2
Spacing, s 372.337 mm

Use s 350 mm

Development Length :

Ld 100 mm
WALL FOOTING
PASSED
DESIGN OF STAIRS

PARAMETERS

Floor to floor height 3.4 m


Riser, r 0.2 m
Thread , t 0.25 m
no. of steps 8
Liveload , LL 4.8 Kpa
fc ' = 21 Mpa
fy = 275 Mpa
ᵞc = 23.5 kN/m3
Steel covering, c = 25 mm
фc = 0.9
ß= 0.85

STEEL REINFORCEMENTS

Main Bar Reinforcement, ø = 12 mm


Temp. Bar Reinforcement, ø = 10 mm

SOLUTION :

Length of stairs 2m
Slab thickness 79.286 mm
d 75 mm

USE : 100 mm

Deadload, DL 7.1661 Kpa

Using load combination 1.2DL+1.6LL :

Wu 16.28 KN/m

Factored Moment, Mu 8.1396 KNm


Ru 0.0016 Kpa

ρ= 0.0026
ρmin= 0.0051
ρmax= 0.0284
use ρ = 0.0051

As = 381.818 mm2
Spacing = 296.207 mm say S = 250
Max. Spacing = 300 mm

Temperature bars :

As = 200 mm2
Spacing = 392.699 mm say S = 350
Max Spacing = 450 mm

DESIGN OF LANDING

Length : 3m
Width : 1.5 m
Required thickness : 50 mm use t = 100

Deadload 2.35 Kpa

Wu 10.5 KN/m

d= 94 mm

MOMENT COEFFICIENTS :

Short-Long Span Ratio, m

@ Negative Moment
32 Cs 0.064
33 Cb 0.036
@ Positive Moment Dead Load
34 Cs 0.035
35 Cb 0.02
@ Positive Moment Live Load
36 Cs 0.04167
37 Cb 0.024
MOMENT LOADS :

@ Negative Moment
Ms 4.545 kN-m
Mb 3.40371 kN-m
@ Positive Moment Dead Load
Ms 0.55705 kN-m
Mb 0.42379 kN-m
@ Positive Moment Live Load
Ms 1.352 kN-m
Mb 1.0368 kN-m

Total + Moments
Ms 2.83166 kN-m
Mb 2.16743 kN-m

REINFORCEMENT REQUIREMENTS

@ Short Direction
-M 4.545 kN-m
w 0.03845
ρ 0.00354
ρmin 0.00614
*use 0.00614

As 491.228 mm2
s 159.885 mm
Use ,s 150 mm

@ Positive Moment (Midspan)


+Ms 2.83166 kN-m
w 0.02374
ρ 0.00219
ρmin 0.00614
*use 0.00614

As 491.228 mm2
s 159.885 mm
Use, s 150 mm

@ Discontinuous edge

S 479.654 mm
Smax 300 mm

*Use 300 mm

@ Long Direction

@Continuous Edge

-M 3.40371 kN-m
w 0.03759
ρ 0.00346
ρmin 0.00614
*use 0.00614

As 491.228 mm2
s 159.885 mm
Use, s 150 mm

@ Positive Moment (Midspan)

+Ms 2.16743 kN-m


w 0.01811
ρ 0.00167
ρmin 0.00614
*use 0.00614

As 491.228 mm2
s 159.885 mm
Use, s 150 mm

@ Discontinuous edge

S 479.654 mm
Smax 300 mm

*Use 300 mm
TEMPERATURE BARS

Ast 200 mm2


Use ø = 10 mm
s 392.699 mm
Smax 300 mm

*Use 300 mm
*RECOMMENDED 300

SLAB SCHEDULE Spacing


TEMP. BAR 300 mm
MID. ALONG SHORT 150 mm
MID. ALONG LONG 150 mm
CONT. ALONG SHORT 150 mm
CONT. ALONG LONG 150 mm