61) Consider to install check valve at cooling water supply of condenser E-503.

64) Consider to install check valve at inlet of Distillation Column T-500.

68) Consider to install check valve at steam supply stream to reboiler E-504

3) Consider to install cooling water flow meter and low flow alarm at cooling coils
of condenser E-503.

35) Consider to install cooling water flow meter and high flow alarm at cooling
water supply pipeline to condenser E-503.

10) Consider to install steam flow meter and low flow alarm at steam supply stream
to reboiler E-504.

33) Consider to install bypass valve and isolation valves around TV-509.

41) Consider to install bypass valve and isolation valves around TV-508.

52) Consider to install flow meter and high flow alarm at distillation column
bottom outlet stream.

18) Consider to install flow meter and low flow alarm at distillation column inlet
stream.

24) Consider to install flow meter and low flow alarm at distillation column bottom
outlet stream.

70) Consider to install high temperature alarm to alert operator at Distillation


Column T-500.

71) Consider to install low temperature alarm to alert operator at (Distillation


Column T-500).

20) Consider to install flow meter and low flow alarm at pump P-501 inlet stream.

From Table 2, it was hghligted improvement is required in condenser E-503. Check


valve at cooling water supply of condenser E-503 is required to prevent back flow
of cooling water. On the other hand, improvement is suggested for reboiler E-504.
To ensure reliable supply of steam, flow alarm is recommended in steam supply
stream in the event of pipe rupture and steam supply system failure. Furthermore,
improvement is also required in Distillation Column T-500. Check valve is required
at the inlet to prevent back flow of process stream wherease flow meter and flow
alarm is installed to ensure consistent inlet flow. Temperature sensor and alarm is
also required to alert the operators in the event of high or low column
temperature. Beside that, improvement is required for control valves TV-509 and TV-
508 in the event of valve failure.In this case, bypass backup valves are required.