You are on page 1of 1

Toil Toil 9'-7" 8'-8" 6'-6" 11'-2" 10'-9" 3'-6" 10" 9'-7" 8'-8" 6'-6" 11'-2" 10'-9" 3'-6"

Toil 9'-7" 8'-8" 6'-6" 11'-2" 10'-9" 3'-6" 10" 9'-7" 8'-8" 6'-6" 11'-2" 10'-9" 3'-6" 10"
5'-0"X8'-8"

3'-212" 3'-21 2'-1012" 2'-1012" 3'-812" 3'-812"


1 1 1 1 1 1
5'-0"X8'-8"

2-16mmØ st. 2-16mmØ st.


2" 2'-2" 2'-2" 3'-7" 3'-7" 3'-2 2" 3'-2 2" 2'-10 " 2'-10 " 2'-2" 2'-2" 3'-82" 3'-8 2" 3'-7" 3'-7"
Kitchen

2 2
Kitchen

6'-0"X3'-7" 6'-0"X3'-7"

5"
4'-6"

6'-10"X4'-8"
4'-6"

Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c. 2-16mmØ ext. Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c.

12"

10"
2-16mmØ ext. Bott. 1 1 1 2-16mmØ CKD
5'-612" 4'-101
2" 3'-10" 6'-612" 8'-6" 5'-6 2" 4'-10 " 3'-10" 6'-6 " 8'-6"
Drawing Drawing 2 2 3-16mmØ st.

9'-7"X8'-2"
2-16mmØ st.

Drawing

Toil
3'-6"

5'-10"X7'-2"
Sup.Sec. Mid.Sec. G.B.-A (10"X12") Sup.Sec. Mid.Sec.
E 8'-1"X7'-10" G.B.-A (10"X12")

Kitchen
8'-1"X7'-10"
10" 10" 10" 10" 10" 10" 10" 10" 10" 10" 10"
10" 10" 10" 10" 10" 10" 10" 10" 10" 10" 10"

M.BED
M.BED BED 13'-3"X8'-0" M.BED BED 9'-7" 8'-8" 6'-6" 11'-2" 10'-9" 3'-6"
5'-0"X7'-6"

1 1 10"
9'-7" 8'-8" 6'-6" 11'-2" 10'-9" 3'-6" 2'-101" 2'-101"
3'-7"X6'-0"

3'-2 " 3'-2 " 2'-2" 2'-2" 1 1 2-16mmØ st.


3'-8 " 3'-8 " 3'-7" 3'-7"
Kitchen

10'-0"X10'-0" 9'-6"X10'-0" 10'-0"X10'-0" 9'-6"X10'-0" M.BED BED 3'-212" 3'-21


2" 2'-101 " 2'-101 " 2'-2" 2'-2" 3'-812" 3'-812"
2-16mmØ st.
10" 2 2 2 2 2 2

5"
2 2 3'-7" 3'-7" Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c.
5'-9"X7'-11"
Toil

1 1 1

10"
Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c. 2-16mmØ ext. 2-16mmØ CKD
Drawing

12"
5'-6 " 4'-10 " 3'-10" 6'-6 " 8'-6"
12'-6"X8'-0" 9'-9"X8'-0" 5'-61 " 4'-101" 3'-10" 6'-61 " 8'-6"
2-16mmØ ext. Bott. 2 2 2 3-16mmØ st.
2 2 2 2-16mmØ st. G.B.-B (10"X12") Sup.Sec. Mid.Sec.
G.B.-B (10"X12") Sup.Sec. Mid.Sec.

3'-8"X5'-3"
ROOF BEAM REINFORCEMENT DETAIL

VER.
GREAD BEAM REINFORCEMENT DETAIL
3'-9"

3'-9"

6'-6" 6'-6"

GROUND FLOOR E
S 1ST FLOOR E
N

S
9'-1" 2'-3"
N

9'-1" 2'-3" 2-16mmØ st.


10" 3'-0" 3'-0" 2-16mmØ st.
10"
3'-0" 3'-0"
W W Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c.

5"
Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c. 2-16mmØ ext.

12"
1'-2"

10"
2-16mmØ ext. Bott. 2-16mmØ CKD
1'-2" Y Y
2-16mmØ st. 3-16mmØ st.
G.B.-1 (10"X12") Sup.Sec. Mid.Sec.
G.B.-1 (10"X12") Sup.Sec. Mid.Sec.

7'-8"X18'-1"
STAIR
9'-1" 2'-3" 10"
9'-1" 2'-3" 2-16mmØ st.
10"
3'-0" 3'-0" 2-16mmØ st.
3'-0" 3'-0" X
up X
01

02

03

04

05

06

Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c.

5"
01

02

03

04

05

06

Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c. 2-16mmØ ext. 1'-2"

10"
12"
2-16mmØ CKD
2-16mmØ ext. Bott.
6'-3" 6'-3" 6'-3" 6'-3" 1'-2"
2-16mmØ st.
3-16mmØ st.

5' 5' G.B.-1 (10"X12") Sup.Sec. Mid.Sec.


G.B.-1 (10"X12") Sup.Sec. Mid.Sec.
3'-2"

3'-2"6'-3"3'-2"

3'-2"

3'-2"
2'-6" 2'-6"

2'-6" 2'-6"

7'-4" 12'-0" 11'-7" 9'-1" 2'-3"


6'-3"

6'-3"

6'-3"

10"
B
3'-0" 3'-0"
B

9'-1" 2'-3" 2-16mmØ st.


5'

5'

10"
2-16mmØ st. Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c.

5"
3'-0" 3'-0"
F1 F2 F2 F2 F2 F1 C1 C2 C2 C2 C2 C1
3'-2"

3'-2"

3'-2"

1'-2"

10"
Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c. 2-16mmØ ext. 2-16mmØ CKD

12"
2-16mmØ ext. Bott. 3-16mmØ st.
1'-2"
2-16mmØ st. G.B.-2 (10"X12") Sup.Sec. Mid.Sec.
2'-6" 2'-6" 2'-6" 2'-6" Sup.Sec. Mid.Sec.
3'-2" 3'-2" 3'-2" 3'-2" 3'-2" 3'-2" 3'-2" 3'-2" G.B.-2 (10"X12")
9'-1" 2'-3"
9'-11"

" 3'-0" 3'-0" 10"


'-5
10mmØ@6"C/C 2-16mmØ st.

14
9'-1" 2'-3" 10" 4'-4" Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c.

5"
2-16mmØ st.
6'-3" 6'-3" 6'-3" 6'-3" 3'-0" 3'-0"
1'-2"

10"
2-16mmØ CKD
5' 5' Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c. 2-16mmØ ext. 10" 10" 10"

12"
2-16mmØ ext. Bott. 3-16mmØ st.
3'-2"

3'-2"6'-3"3'-2"

3'-2"

3'-2"

1'-2"

6" 6" 6"


G.B.-3 (10"X12")
2'-6" 2'-6"

2'-6" 2'-6"

2-16mmØ st. 12mmØ@7"C/C Sup.Sec. Mid.Sec.


F2 F2 F2 F2 C1 C2 C2 C2 C2 C1 Sup.Sec. Mid.Sec.
L/2
9'-1" 2'-3"

5'-0"
G.B.-3 (10"X12")
6'-3"

6'-3"

6'-3"

10mmØ@6"C/C
C

10"
5'

5'

10mmØ@6"C/C 3'-0" 3'-0" 2-16mmØ st.


C

5" L/4
9'-1" 2'-3" 10" Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c.

5"
3'-2"

3'-2"

3'-2"

2-16mmØ st.
F1 F1 SEC:Y-Y (2ND FLIGHT)
1
3'-0" 3'-0" 4'-54"
1'-2"

10"
2-16mmØ CKD
Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c. 2-16mmØ ext. 12mmØ@5"C/C

12"
L/2 3-16mmØ st.
2-16mmØ ext. Bott.
2'-6" 2'-6" 2'-6" 2'-6" 1'-2"
2-16mmØ st.
G.B.-4 (10"X12") Sup.Sec. Mid.Sec.
3'-2" 3'-2" 3'-2" 3'-2" 3'-2" 3'-2" 3'-2" 3'-2" 12mmØ@7"C/C
COLUMN CENTER LINE G.B.-4 (10"X12") Sup.Sec. Mid.Sec.
5" 10mmØ@6"C/C
waist slab thicness= 6" 9'-1" 2'-3"
3'-0" 3'-0" 10"
2-16mmØ st.

FOUNDATION LAYOUT PLAN


1
4'-54"
9'-1" 2'-3" Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c.

5"
10" 10" 10" 10"
2-16mmØ st.
3'-0" 3'-0" 1'-2"

10"
2-16mmØ CKD
Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c. 2-16mmØ ext. 3-16mmØ st.

12"

6" 6" 6"


2-16mmØ ext. Bott. L/2 G.B.-5 (10"X12")
1'-2" Sup.Sec. Mid.Sec.
2-16mmØ st. 12mmØ@7"C/C

5'-0"
Sup.Sec. Mid.Sec.
G.B.-5 (10"X12") 10mmØ@6"C/C L/4 9'-1" 2'-3" 10"
10mmØ@6"C/C 3'-0" 3'-0" 2-16mmØ st.
SEC: X-X (1ST FLIGHT) 4'-4"
Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c.

5"
9'-1" 2'-3" 2-16mmØ st.
10" L/2
1'-2"

10"
3'-0" 3'-0" 12mmØ@5"C/C 2-16mmØ CKD
01

02

03

04

05

06

01

02

03

04

05

06

2-16mmØ ext. 3-16mmØ st.


Stirrup 5"/7"/5" c/c. Stirrup 5"/7"/5" c/c.

12"
2-16mmØ ext. Bott. 12mmØ@7"C/C G.B.-6 (10"X12") Sup.Sec. Mid.Sec.
1'-2"
2-16mmØ st.

G.B.-6 (10"X12") Sup.Sec. Mid.Sec.


STAIR CASE REINFORCEMENT DETAIL ROOF BEAM REINFORCEMENT DETAIL
2'-3"

2'-3"

GREAD BEAM REINFORCEMENT DETAIL


B

B
9'-1"

9'-1"

6"
Outlet (From UGWT To OHWT)
A

6"

3"
9'-7" 8'-8" 6'-6" 11'-2" 10'-9" 3'-6" 9'-7" 8'-8" 6'-6" 11'-2" 10'-9" 3'-6" 10mmØ@ 6" c/c . 10mmØ@ 412" c/c
51"
2
OUTLET INLET
Inlet

2'-3"
GREAD BEAM LAYOUT PLAN ROOF BEAM LAYOUT PLAN
8"Free Board Level 8"
6" R.C.C

6"
10mmØ@ 8" c/c

6'-0"
VOID

1'-6"
10" BRICK WALL

10mmØ@9" c/c

8'4"
7"

5"

1'-6"
9'
10mmØ@ 7" c/c
7"

SLAB THICK 5"


SCHEDULE OF COLUMN REINFORCEMENT 10mmØ@4" c/c

SECTION :-X-X

NAME OF 10mmØ@ 10" c/c 10mmØ@ 5" c/c both way.


10mmØ main bar Alt. ckd 5" C/C.

8"

1'

UP TO GB GB TO ROOF FLOOR
41"
2
1'

COLUMN 9"
9"

3" 3"BFS
BEAM
3"

SECTION Y-Y
12 10
1-12mmØ ext. 1-12mmØ ext. 1-12mmØ ext. 5"

18'-6" 12'-10"
L/4

16"mmØ@15"c/c ladder 5" Brick Wall.


12

10

C1 10 mm Ø @ 10 mm Ø @
4"/6"/4" C/C 4"/6"/4" C/C

12Ø@4''c/c
1-12mmØ ext.

10mmØ main bar Alt. ckd 5" C/C. 10mmØ main bar Alt. ckd 5" C/C.

4'-1
L/2

10mmØ@ 6" c/c alt. ckd +1 ext top

7" R.C.C.
5-16 mm Ø 5-16 mm Ø
Inlet X X
12Ø@5''c/c
6'-9"

24" Dia Manhol


12 10
1-10Ø ext. T=6" 1-10Ø ext.
L/4

Outlet
10mmØ@ 412" c/c alt. ckd + 1 ext top 4'-1
12'-0"

BEAM

8-10Ø St.

8-10Ø St.
4-10"Ø extra.
17

15

C2 10 mm Ø @ 10 mm Ø @
SLAB REINFORCEMENT DETAIL 4"/6"/4" C/C 4"/6"/4" C/C
Y Y
PLAN
8-16 mm Ø 8-16 mm Ø

R9

R9
"

"
7"
TOP SLAB REINFORCEMENT.
COLUMN REINFORCEMENT DETAIL
5"

6'-3" PLAN OF UNDER GROUND WATER TANK


16"mmØ@15"c/c ladder

5' NOTE :-
3'-2"

PROPO. SITE
2'-6" 2'-6"

Clear cover to
Footing =3"
6'-3"

fy = 60000 psi
5'

fc' =4000 psi

F2
3'-2"

F1 **Footing depth
=4'-0" from EGL.

2'-6" 2'-6"
3'-2" 3'-2"

2276
C-10"X15" 4'-1" 4'-1"
3"
C-10X12" P.L
P.L
12'-10"

10'-4"
G.B
G.B E. G. L 2249
E. G. L
C-12"X17"
C-12X14"
4'
4'

4" 4" 4" 4" 4"


4" 4" 4" 4" 4"

16" 17"
13" 4"
12" 4"

16mm@6" C\C 16mm@6" C\C

3" B.F.S. 3" B.F.S.


Footing-1 5'X5' Footing-2 6'-3"X6'-3" ROAD
SEPTIC TANK
N
FOOTING REINFORCEMENT DETAIL
W

MOUZA MAP
S

PROJECT AREA ENGINEER SIGN. OWNERS SIGN. APPROVAL AUTHORITY CONSULTANT

FT
PLAN OF PROPOSED 4- STORIED RESIDENTIAL BUILDING FOR
NTH AREA - MD x, B.S. = 937.45 SFTo,o,
DAG NO- x,y,
PLINTH AREA -985.99 SFT X3 = 2958.00
MOUZA- o, P.O.:SFT
o, z, CHITTAGONG.
.............................................= 3896.00 SFT CELL-o
P.S- o, DIST- CHITTAGONG.

You might also like