ART-FEB/04-01
PASOLINK PLUS
INTRODUCTION
1 x 34MB
TX POWER CONTROL
• Automatic Transmit Power Control (ATPC)
• Manual Transmit Power Control (MTPC)
SYSTEM FLEXIBILITY
• (1 + 0 ) unprotected
• (1+1) Hot standby or Twin path
• Space and frequency diversity
• Common IDU for different RF frequencies (6/7/8/13/15/18/23/26/38 GHz)
• Wide input line voltage ±(20 to 60) V DC
• Event Logging
• ITU-T G.826 Performance Monitor (Table /graph presentation)
Antenna
Antenna IF
IF
TX RX
IDU
ODU IDU
( 1+0 ) RX TX ODU
( 1+0 )
.
PASOLINK PLUS INTRODUCTION - STM1 17
PERFORMANCE NECITR-YTC
ART-FEB/04-01
ITEM 6/7/8 GHz 11 GHz 13 GHz 15 GHz 18 GHz 23 GHz 26 GHz 38GHz
Frequency Range [GHz] 5.9-8.5 10.7-11.7 12.75- 14.5- 17.7- 21.2- 24.5- 37-40 GHz
13.25 15.35 19.7 23.6 26.5
Channel Spacing (MHz)
STM-1 Narrow Band 27.5 ( 28 )
.
PASOLINK PLUS INTRODUCTION - STM1 18
IDU Performance NECITR-YTC
ART-FEB/04-01
Modulation 128QAM
INTERFACES
ITEM STM-1/OC3 Narrowband STM-1/OC3
STM-1 electrical Type ITU – T G.703
155.520 Mbit/s (CMI), 1 VP-P 75 ohms unbalanced
DATA SPEED 155.520 Mbps 155.520 Mbps FREQUENCY 340 MHz 140 MHz
LEV G7898A OPT INTFC -8 to -28 dBm -8 to -15 dBm LEVEL -2 to 29 dBm -15 to -55 dBm
MAINT LED
Maintenance Mode ON
Loopback control ON
CW mode ON
TX Power Mute ON
ALS MANUAL RESTART
ATPC MANUAL CONTROL
PWR SW
Turns input DC power ON/OFF ODU1 and ODU2 ALM LED
Transmit RF power decrease by 3 to 6 dB from nominal
Receiver level goes below squelch level
ODU local oscillator APC loop unlock
IF signal from the IDU is low
Loopback control ON
CW mode ON
TX Power Mute ON
ALS MANUAL RESTART ODU1 and ODU2 ALM LED
ATPC MANUAL CONTROL Transmit RF power decrease by 3 to 6 dB from nominal
Receiver level goes below squelch level
ODU local oscillator APC loop unlock
RESET SW IF signal from the IDU is low
Initialize CPU
R SW
R SW
Switch to previous program version after program update
CALL SW
EOW calling signal,opposite station buzzer rings
ALM LED (WS INTFC MODULE) ALM LED (150M INTFC/OPT INTFC)
WS INTFC Module fail Input STM-1 data signal is lost
Input STM-1 frame sysnchronization is lost
150M intfc/opt intfc module fail
E-BER alarm is detected
SD alarm is detected
LINE IN
•IF IN/OUT
1 0V or (+48V)
2 -48V or (0V)
3
4
NEC PASOLINK PLUS SYSTEM HAS THE FOLLOWING ITU-T STANDARD INTERFACES
DIGITAL SIGNAL INTERFACES
• Main traffic STM-1 Electrical
Type (ITU-T G.703): in station section, full functionality
Bit Rate: 155.520 Mbit/s ± 20ppm
Level: 1 Vp-p (nominal) (TX accepts 12.7dB cable loss at 78 MHz)
Code Format: CMI
Impedance: 75 ohms, unbalanced (nominal)
Connector: IEC 169-13
• Main traffic STM-1 Optical
Type (ITU-T G.957): S-1.1 (Inter office)
Bit Rate: 155.520 Mbit/s ± 20ppm
Level: S-1.1 -8 to -15 dBm
Connector FC/PC
• Wayside Traffic Transmission using RFCOH (option, 32QAM and 128QAM Enhanced Ver. only)
Bit Rate: 2.048 Mbit/s ± 50ppm/1.544 Mbit/s ± 130ppm
Input/output Level: 2.37 Vo-p 75 Ohms/3.0 Vo-p/3.0 v
(75 Ω unbal 2Mbit/s)(120 Ω bal 2Mbit/s)(100 Ω bal1.544Mbit/s)
Code format HDB-3/ AMI or B8Zs
Connector D-Sub 9 pin
• SOH Termination: RST
RF INPUT / OUTPUT PORT
Antenna direct mount type : 11-38 GHz NEC original interface
Coaxial interface type : 6-8 GHz SMA Coaxial Connector ( N-type optional)
6 WS or Digital 1.544 or 2.048 Mbps, RFCOH( 32 QAM /128 QAM Enhanced Ver. Option
only) or
7 LAN Digital Option
10 Base –T: 32 QAM use 2.048 RFCOH
128 QAM use DSC or RSOH(E1/F1) 64Kbps
128 QAM (Enhanced Ver) use 2.048 RFCOH
STAR UP
•Check that the LINE IN voltage is
between +20 V to +60V (or -20 V to -72
V) with a digital multi-meter, before
connecting the power connector to the
IDU
•Turn ON the Power switch on the IDU
•Allow equipment to warm up for at least 30
minutes
SHUT DOWN
•Turn OFF the power switch on the front of
the IDU No.2 CH Line IN
No.2 CH Power Switch
Protection switching is provided in (1+1) Twin Path and Hot Standby systems. The receive side protection switching is
performed by a Hitless Switch in the 150 M INTFC / OPT INTFC or 10/100BASE-T INTFC module.
Priority 1: Manual switching Control
Manual switching is initiated from external equipment (LCT/PNMT)
Priority 2: Automatic switching control
For any alarm in the online equipment, traffic will be switched to the standby equipment automatically. TX and
RX switchover are performed independently.
RX switching
TX switching
This apply to both HS and
In the (1+1)HS system Twin Path configurations.
transmit switching is carried When the Online RX CH fails
out by setting the standby or LOW BER Alarm is
ODU out put to off by Muting detected the ALM CONT
it. The data signal is circuit in the SW Board initiate
transmitted in parallel to both a RX SW Control signal to
CH1 and CH2. switch to the standby CH
provided it is in normal
operating condition.
2. Priority No.1 When both channels are normal always selects CH1 as online.
When CH1 is faulty automatically change to CH2 provided it is
normal. When CH1 recovers return to CH1 automatically.
When the optical signal input to the main interface is lost, the ALS
function automatically shuts the main interface output laser
Tx Out
High
Max. Tx Lev
(Provisioning)
Min Tx Lev
(Provisioning)
Low Fading
Deep Shallow
The ATPC Control transmits the information on the
receiving level to the opposite station and controls
Rx Lev
the transmission level of its own station in
High accordance with the receiving level of the opposite
station.
ATPC hysteresis
(provisioning)
ATPC Rx Threshold The ATPC Control can be used in several configurations:
(provisioning)
ATPC - ATPC
MTPC - ATPC
Low ATPC - MTPC
Deep
Fading
Shallow
(d)
(a) STM-1 near-end loopback (STM-1 LB1) at the 150M INTFC/OPT INTFC module
(b) STM-1 far-end loopback (STM-1 LB2) at the 150M INTFC/OPT INTFC module from LCT
(c) IF loopback (IF-LB) at the MODEM module (Local only)
(d) STM-1 far-end loopback (STM-1 LB2) at the 150M INTFC/OPT INTFC Module from PNMT/PNMS
•Note: While the IF loopback is in execution, monitoring of the opposite and the subsequent stations from
the PNMS and PNMT are disabled.
DETECTING CIRCUIT ALARM CONDITION MODULE LED ALM INITIATED LED INDICATION
INPUT STM-1 SIGNAL IS LOST FROM MUX ALM (150/OPT INTFC) MAIN INTFC LOS IDU 1 & 2 ALM
FRAME SYNCHRONIZATION OF INPUT STM-1 SIGNAL FROM MUX IS LOST ALM (150/OPT INTFC) MAIN INTFC LOS IDU 1 & 2 ALM
BER IS WORSE THAN PRESET VALUE (10 TO 10 SELECTABLE) FROM MUX SIDE
-3 -5
ALM (150/OPT INTFC) E-BER MUX IDU 1 & 2 ALM
BER IS WORSE THAN PRESET VALUE (10 TO 10 SELECTABLE) FROM MUX SIDE
-5 -9
ALM (150/OPT INTFC) SD-MUX IDU 1 & 2 ALM
RECEIVE STM-1 SIGNAL FROM RADIO IS LOST IDU 1 & 2 ALM
ALM (150/OPT INTFC) MAIN INTFC LOS DMR
FRAME SYNCHRONIZATION OF THE STM-1 SIGNAL RECEIVED FROM RADIO LINK IS LOST IDU 1 & 2 ALM
ALM (150/OPT INTFC) MAIN INTFC LOF DMR
150 / OPT INTFC
BER IS WORSE THAN PRESET VALUE (10 TO 10 SELECTABLE) FROM RADIO SIDE
-3 -5
ALM (150/OPT INTFC) E-BER DMR IDU 1 & 2 ALM
BER IS WORSE THAN PRESET VALUE (10 TO 10 SELECTABLE) FROM RADIO SIDE
-5 -9 ALM (150/OPT INTFC) SD DMR IDU 1 & 2 ALM
150M INTFC / OPT INTFC MODULE FAILURE ALM (150/OPT INTFC) MAIN INTFC IDU 1 & 2 ALM
COLX/DUPLEX(BLINK)
10/100BASE-T COLLISION CONDITION OCCURS (10/100BASE-T INTFC) COLLISION
INTFC ALM(10/100BASE-T
LINK OF LAN (10/100 BASE-T INTFC) AND ASSOCIATED EQUIPMENT IS NOT ESTABLISHED INTFC) LINK IDU 1 & 2 ALM
WSINTFC/LAN WS INTFC/ LAN CARD MODULE FAILURE ALM(WS INTFC/LAN) SUB INTFC IDU 1 & 2 ALM
MODEM DEMODULATOR FAILURE AND INPUT IF SIGNAL LOSS DEM ALM IDU 1 & 2 ALM
BER IS WORSE THAN PRESET VALUE (10-4 TO 10-6 SELECTABLE) FROM RADIO SIDE HIGH BERF ALM IDU 1 & 2 ALM
TRANSMIT RF POWER INCREASE/DECREASE BY APPROX. 3 dB FROM NOMINAL TX POWER ALM ODU 1& 2 ALM
TX IF SIGNAL FROM THE IDU IS LOST TX INPUT ALM ODU 1& 2 ALM
ODU
RECEIVER INPUT ;EVE; DECREASES BELOW SQUELCH LEVEL(32QAM -81dBm, 128 QAM -72 dBm) RX LEV ALM ODU 1& 2 ALM
APC LOOP OF THE LOCAL OSCILLATOR UNLOCK APC ALM ODU 1& 2 ALM
COMMUNICATION BETWEEN IDU AND ODU IS LOST CABLE ALM ODU 1& 2 ALM
WHEN EQUIPMENT IS SET TO ONE OR MORE OF THE FOLLOWING CONDITIONS
MAINTENANCE MODE
MAINTENANCE MAINT MAINT
FAR END / NEAR END LOOPBACK ON / ATPC MANUAL CONTROL
IFConnector
IF Connector&&Power
Power
Connectortermination
termination Confirm 19" Rack Location
Connector
& DC-Power Source
19"rack
19" rackfixing
fixing
FollowThe
Follow The
terminationProcedure
termination Procedure IDU
Mounting
RackEarthing
Rack Earthing
Connection
Connection
Refer to the IDU fixing IFCable
IF Cable
Procedure Photos Connection
Connection
IDUGrounding
IDU GroundingConnection
Connection
FRONT POSITION
More than one
rack unit
WALL
-4 Put-6
Connect Connect-5
the
the IF the Power
Label
Cable Cable
s
Connect-3
the STM-1 Fix the 4-1
Connect the-2 Cable screw (2 for
frame Earthing each side)
PASOLINK PLUS INTRODUCTION - STM1 48
NECITR-YTC
ART-FEB/04-01
Luck Nut
Washer
Gasket
Clamp A
Clamp B
Insulation
Center
Conductor
Connector Shell
IF Cable Termination NECITR-YTC
ART-FEB/04-01
Gasket
washer
Lock Nut
PASOLINK PLUS INTRODUCTION - STM1 50
NECITR-YTC
ART-FEB/04-01
Fit Clamp A
PASOLINK PLUS INTRODUCTION - STM1 NESIC
51 CAIRO
NECITR-YTC
ART-FEB/04-01
Cut the
extra length,
to fit to
Clamp A
CABLE
Power
Connector
Socket Contact
Power
Cable
NECITR-YTC
ART-FEB/04-01
2
2- Set the socket contact to the following
position onto the hand crimping tool
3- Squeeze the handle of the hand crimping tool, insert cable into socket
contact
4- Cable should fit, so insulation and bare wire are arranged as shown,
5- Squeeze the handle of the hand crimping tool until ratchet is released.
Squeeze the-5
handle of the hand
crimping tool until
ratchet Is released
)V 0 (
New Type Bracket for 11-38 GHz Band ODU Old Type Bracket for 11-38 GHz Band ODU
SCREWS
SCREWS
H - POLARIZATION ANTENNA
CONNECTION
UNIT
1.Mount the Hybrid to the Antenna with screws, use the 2.Fix the ODUs one by one to the Hybrid. Take care not
guide pins to position correctly to damage the o-rings.
PASOLINK PLUS INTRODUCTION - STM1 68
ANTENNA DIRECT MOUNT – V/H POL NECITR-YTC
ART-FEB/04-01
•When vertical polarization is required, rotate the •When horizontal polarization is required, rotate the
IDU so that the plate marked with V is pointing up. IDU so that the plate marked with H is pointing up.
Fix the ODU in this position Fix the ODU in this position
PTT
2-Data Bits
8
3-Parity
None
4-Stop bits
1
5-Flow Control
6- Press OK
Hardware
NESIC CAIRO
PASOLINK PLUS INTRODUCTION - STM1 80
HyperTerminal setting NECITR-YTC
ART-FEB/04-01
2-Select
“VT100”
VT100
500
3-Press
“ASC II setup
Wrap lines
that exceed
7- OK 8- OK
terminal width NESIC CAIRO
PASOLINK PLUS INTRODUCTION - STM1 81
IDU Setting NECITR-YTC
ART-FEB/04-01
1-Press 4
System
Configuration
2- Setup Radio
equipment
Configuration
Enter TX
Frequency & Press
Enter Key
Select TX Power
Control to MTPC &
Press Enter Key
Select Main
Interface & Press
Enter Key
1- At each station,
press the “9” key
twice for setting
the
Antenna Alignment
mode of
“Maintenance” and
press the
“Enter” key,
At each station remove the cap from the RX LEV MON connector.
At each station connect cable between the RX LEV MON
connector in the ODU and OW/RX LEV IN connector in the OW/
RX LEV MONITOR unit or digital multi-meter.
Adjust the azimuth and the elevation so as to maximize the RX
LEV voltage indicated on the voltage display, one station at a
time.
Low BER and High BER are fixed to 3 x 10-7 and 3 x 10-4.
PASOLINK PLUS INTRODUCTION - STM1 89