NECITR-YTC

ART-FEB/04-01

PASOLINK PLUS

INTRODUCTION

NEC International Training, Ltd.


Yokohama Training Center
PASOLINK FAMILY NECITR-YTC
ART-FEB/04-01

4/6GHz 7/8GHz 11GHz 13GHz 15GHz 18GHz 23GHz 26GHz 38GHz


SERIES/MODEL SYSTEM MODULATION INTERFACE 3.6-7.1 7.1-8.5 10.7-11.7 12.7-13.2 14.2-15.3 17.7-19.7 21.2-23.6 24.2-27 37-40

PASOLINK V3 PDH 4PSK 2x2MB


4x2MB
8x2MB
16x2MB
1x8MB
1x34MB
PASOLINK V4 PDH 4PSK 2x2MB
4x2MB
8x2MB
16x2MB
(2x10/100Base-T)
PDH 16QAM + RS 8x2MB
PASOLINK+ 16x2MB

1 x 34MB

SDH 32QAM+RS 21x2MB


(STM-0) (STM-1)
SDH 32QAM +RS STM-1
(STM-1) 2x10/100Base-T
SDH 128QAM+RS STM-1
(STM-1) 2x10/100Base-T
SDH 128QAM+RS STM-1
XPIC (2xSTM-1) 2x10/100Base-T

PASOLINK PLUS INTRODUCTION - STM1 2


FEATURES NECITR-YTC
ART-FEB/04-01

ADVANCED TECHNOLOGIES AND SUPERB PERFORMANCE


• MIC, MMIC, HIC and VLSI all solid state circuitry from data input to RF input
• Single chip modulator/ demodulator (Full digital)
• Square-root Nyquist Roll-off shaping filter
• High reliability
• Low power consumption
HIGH SYSTEM GAIN
• With PASOLINK PDH (QPSK) and PASOLINK PLUS SDH (32QAM )
• Multi-Level Coding Modulation (MLCM) used to ensure better error performance
• Forward Error Correction (FEC) with Reed Solomon coding.
• Allows smaller antennas and reducing system cost

FREQUENCY AGILITY AND EASY TUNING


• Field tunable local oscillators (Synthesizer)
• Changing RF point frequency without changing modules or measuring equipment

CONFORMITY WITH ITU-R, ITU-T AND ETSI STANDARDS


PASOLINK PLUS INTRODUCTION - STM1 3
FEATURES NECITR-YTC
ART-FEB/04-01

EASY AND QUICK INSTALLATION


• Very compact and light
• Only one coaxial cable interconnection
• Different mounting methods for IDU, ODU and Antenna
• Easy antenna pointing adjustments (RX level monitor point in ODU)

TX POWER CONTROL
• Automatic Transmit Power Control (ATPC)
• Manual Transmit Power Control (MTPC)

SYSTEM FLEXIBILITY
• (1 + 0 ) unprotected
• (1+1) Hot standby or Twin path
• Space and frequency diversity
• Common IDU for different RF frequencies (6/7/8/13/15/18/23/26/38 GHz)
• Wide input line voltage ±(20 to 60) V DC

PASOLINK PLUS INTRODUCTION - STM1 4


FEATURES NECITR-YTC
ART-FEB/04-01

EASY MAINTENANCE FACILITIES


• Full front panel access for all cabling and user interfaces
• IF, Near End Base-Band and Far End Base-band Loop back facilities
• Remote monitoring of ODU operating condition from IDU
• OW calling facility between IDU - ODU, IDU – IDU and ODU-ODU
• Local and remote supervision function on IDU
• Local monitor and maintenance using Local Craft Terminal (LCT)
MULTIPLE SERVICE CHANNELS
• Engineering Order Wire (OW)
• Digital Service Channels - Two
• Analog Service Channels- Two
• 10 Base – T : One channel optional
• wayside : 2.048/1.544 Mbps ,one channel (option for 32 QAM /128QAM Enhanced Ver. )
• NMS Service Channel for Pasolink Monitoring
• Cluster ALM

ELECTRO MAGNETIC COMPATIBILITY (EMC)

• Complies with ETS 300385 Class B


PASOLINK PLUS INTRODUCTION - STM1 5
FEATURES NECITR-YTC
ART-FEB/04-01

PASOLINK NETWORK MANAGEMENT SYSTEM (PNMS) (OPTION)


• User friendly operation
• Uses Windows NT/2000 to ensure easy operation and maintainability
• Remote access and control of any PASOLINK Terminal in the network
• Link oriented monitor and control ( both side of a microwave link)
• Multi level security

• Event Logging
• ITU-T G.826 Performance Monitor (Table /graph presentation)

• SNMP Interface (Option)

• Real-time monitor of Network Elements (NE)

PASOLINK NETWORK MANAGEMENT TERMINAL (PNMT) (OPTION)

• User friendly operation as maintenance terminal


• Link oriented monitor and control
• Uses Windows XP/2000/NT/98/95 with mobile PC
PASOLINK PLUS INTRODUCTION - STM1 6
System Composition NECITR-YTC
ART-FEB/04-01

1- Indoor unit (IDU) ( Modulation-Demodulation unit)


2- Outdoor unit (ODU) ( Transmit – Receive unit)
3- IF cable and connectors ( To connect the IDU & ODU)
4- Antenna on the required microwave band
5- Hybrid ( coupler ) in case of 1+1 one antenna configuration
6- RF cable ( If the ODU is not direct mounted to the antenna)
ODU (low band)
ODU (High band) TX RX
TX/RX
TX/RX
RF RX TX RF

Antenna
Antenna IF
IF

MODEM Base Band


MODEM Base Band
STM-1
STM-1
IDU
IDU

PASOLINK PLUS INTRODUCTION - STM1 7


Equipment NECITR-YTC
ART-FEB/04-01

PASOLINK PLUS INTRODUCTION - STM1 8


PASOLINK STM-1 (1+1) SYSTEM
NECITR-YTC
PLUS ART-FEB/04-01

PASOLINK PLUS INTRODUCTION - STM1 9


1+1 switch NECITR-YTC
ART-FEB/04-01

PASOLINK PLUS INTRODUCTION - STM1 10


OUT DOOR UNIT (11 to 38 Ghz) NECITR-YTC
ART-FEB/04-01

•WG OUTPUT ( Interface with


the antenna )
•ODU – IDU CONNECTOR ( N-
type connector)

•OW/RX LEV CONNECTOR

PASOLINK PLUS INTRODUCTION - STM1 11


ODU 6/7/8 GHz NECITR-YTC
ART-FEB/04-01

•RF IN/OUT SMA CONNECTOR


(COAXIAL)
•IFL - IF IN/OUT N- type CONNECTOR
(COAXIAL)

•RX LEV MON – OW CONNECTOR

PASOLINK PLUS INTRODUCTION - STM1 12


ODU composition NECITR-YTC
ART-FEB/04-01

PASOLINK PLUS INTRODUCTION - STM1 13


Rxlevel and Rx voltage NECITR-YTC
ART-FEB/04-01

PASOLINK PLUS INTRODUCTION - STM1 14


System Configuration NECITR-YTC
ART-FEB/04-01

A- Non protected system (I+0)

TX RX
IDU
ODU IDU
( 1+0 ) RX TX ODU
( 1+0 )

B- Protected system (1+1) hot standby


Single antenna configuration
TX/RX
TX/RX
ODU-1 ODU-1
Modem-1 TX RX Modem-1
Switch H
Rx only H Switch
Modem-2 Rx only
RX TX Modem-2
ODU-2
ODU-2

PASOLINK PLUS INTRODUCTION - STM1 15


System Configuration NECITR-YTC
ART-FEB/04-01

C- Protected system (1+1) hot standby –Space diversity


Double antenna configuration
TX/RX RX TX
TX/RX
ODU-1
ODU-1
Modem-1 RX Modem-1
TX
Switch Switch
Rx only Rx only
Modem-2 Modem-2
ODU-2 ODU-2
RX
RX

D- Protected system (1+1) Twin path –


Frequency diversity
TX/RX RX TX TX/RX
ODU-1
ODU-1
Modem-1 RX
TX Modem-1
Switch TX\Rx Switch
Modem-2 TX RX TX\Rx
Modem-2
ODU-2
ODU-2
RX TX

PASOLINK PLUS INTRODUCTION - STM1 16


ODU – PERFORMANCE NECITR-YTC
ART-FEB/04-01

ITEM 6/7/8 11 GHz 13 GHz 15 GHz 18 GHz 23 GHz 26 GHz 38GHz


GHz
Frequency Range [GHz] 5.9-8.5 10.7-11.7 12.75- 14.5-15.35 17.7-19.7 21.2-23.6 24.5-26.5 37-40
13.25 GHz
TX Output Power (dBm)
STM-1 (128 QAM) +25 16.5 16.5 16.5 15.0 15 14.0 10.5

Receiver Threshold (dBm)


at 10-6 BER
STM-1 (128 QAM) -68.0 -67.0 -67.0 -67.5 -67.5 -67.5 -67.0 -66.0

Receiver Threshold (dBm)


at 10-3 BER
STM-1 (128 QAM) -69.0 -68.0 -68.0 -68.5 -68.5 -68.5 -68.0 -67.0

System Gain at 10-6 BER


STM-1 (128 93.0 83.5 83.5 84.0 82.5 82.5 81.0 76.5
QAM)

System Gain at 10-3 BER


STM-1 (128 QAM) 94.0 84.5 84.5 85.0 83.5 83.5 82.0 77.5

.
PASOLINK PLUS INTRODUCTION - STM1 17
PERFORMANCE NECITR-YTC
ART-FEB/04-01

ITEM 6/7/8 GHz 11 GHz 13 GHz 15 GHz 18 GHz 23 GHz 26 GHz 38GHz

Frequency Range [GHz] 5.9-8.5 10.7-11.7 12.75- 14.5- 17.7- 21.2- 24.5- 37-40 GHz
13.25 15.35 19.7 23.6 26.5
Channel Spacing (MHz)
STM-1 Narrow Band 27.5 ( 28 )

Frequency stability ± 10 ppm (0.001%)


ATPC and MTPC Range 128 QAM: -20 to 0 dB in 1 dB steps
Tuning Bandwidth Center Up to 50 MHz Up to 370 MHz (Depends on TX - RX
Tuned spacing)
Depends on T-R spacing
Ambient Temperature Range -33OC to + 50OC
EMC Conforms to ETS300 385 Class B
Power Supply (±48 V ) ±36 to ±60 VDC (± 24V option)
Typical Power Consumption (1+0) system : 6-8 GHz – 65W, 11-38 GHz – 55W , (1+1) system : 6-8 GHz – 130W, 11-38 GHz
– 110W

.
PASOLINK PLUS INTRODUCTION - STM1 18
IDU Performance NECITR-YTC
ART-FEB/04-01

ITEM Narrowband STM-1/OC3

Modulation 128QAM

Symbol Frequency 24.236883 MHz

Demodulation Coherent detection

Forward Error Correction Reed-Solomon Coding

Additional Attenuation 5 dB for span equalization

Data Interface Electrical / Optical / LAN

SOH Termination RST Mode

BB Loopback Far End / Near End

IF Loopback Local only


PASOLINK PLUS INTRODUCTION - STM1 19
STM-1 PERFORMANCE NECITR-YTC
ART-FEB/04-01

INTERFACES
ITEM STM-1/OC3 Narrowband STM-1/OC3
STM-1 electrical Type ITU – T G.703
155.520 Mbit/s (CMI), 1 VP-P 75 ohms unbalanced

STM-1 Optical Type ITU – T G.957: S-1.1


155.520 Mbit/s (NRZ), (Intra Office) wave length 1310 nm,
STM-1 Optical Type ( Mono Fiber) 155.520 Mbit/s, (NRZ), TX wave length : A:1310 nm , B: 1550 nm
RX wave length : A:1550 nm, B: 1310 nm
Mean optical output power: -7 dBm
Minimum Receive overload power : -3 dBm
Minimum Receive Sensitivity : -23 dBm

Wayside Interface (WS) (Option) 1 Channel WS OPTION IS ALSO AVAILABLE ON


Not available on 128 QAM. 1.544 Mbps 2.048 Mbps STM-1, 128 QAM (ENHANCED
3.0VO-P (100ohms bal) 2.37VO-P(75ohms unbal) VERSION)
3.0VO-P(120ohms bal)
B8ZS or AMI HDB3
LAN Interface (option) 10-Base T, RJ 45 Connector @ WS Rate 64Kbps (WS Rate in Enhanced Version)
Digital Service Channel (DSC) 2 Channels , (V11 contra / co-directional) selectable, 64 Kbps, 100 ohms
Voice Frequency Service Channel (VF) 2 Channels, 4 wire, (0.3 to 4KHz) -6 dBm (nominal), 600 ohms balanced
Housekeeping Alarms / Control Input (Alarms) 6 photo coupler
Output (Control) 4 Form-C dry contact relays
IDU – ODU connection (IFL) Single coaxial cable , 50ohms
300m (8D-FB type cable), 350m (10D-FB type cable), 450m (12D-FB type cable)

PASOLINK PLUS INTRODUCTION - STM1 20


IDU BLOCK & LEVEL DIAGRAM NECITR-YTC
ART-FEB/04-01

DATA SPEED 155.520 Mbps 155.520 Mbps FREQUENCY 340 MHz 140 MHz

LEV G7898A OPT INTFC -8 to -28 dBm -8 to -15 dBm LEVEL -2 to 29 dBm -15 to -55 dBm

LEV G7899 OPT INTFC -3 to -23dBm -7 dBm IMPEDANCE 50 Ohms Unbalanced

150M INTFC 1.0 VP-P 1.0 VP-P •Single Coaxial Cable


75 Ohms Unbalanced 75 Ohms Unbalanced

•LAN INTFC 10/100 Base-T


MODEM ODU INTFC
150M INTFC IF IN/OUT
No.1 No.1
STM-1 IN OR
OPT INTFC
STM-1 OUT OR
10/100Base-T MODEM ODU INTFC
IF IN/OUT
No.2 No.2
EOW
•150m (5D-FB)
WAYSIDE •300m (8D-FB)
Way side INTFC
CONTROL
•350m (10D-FB)
•450m (12D-FB)
10 BASE-T LAN CARD

WAY SIDE IN/ OUT

DATA SPEED 1.544 Mbps / 2.048 Mbps

LEVEL 3.0 V0-P/ 2.37VO-P / 3.0 VO-P


INTERFACE IMPEDANCE
IMPEDANCE 100 Ohms, Balanced/75 ohms PNMT
unbalanced / 120 ohms balanced EOW2 RS-232C
LCT
E0W1 RS-232C
NE1
RS-422-64K 100 Ohms
NE2
FREQUENCY 0.3 to3.4 KHz 0.3 to3.4 KHz RS-485 100 Ohms
PNMS V11
LEVEL -6 dBm -6 dBm V.11 100 Ohms
PNMS LAN
IMPEDANCE 600 Ohms 10 BASE-T

PASOLINK PLUS INTRODUCTION - STM1 21


INDICATORS/SWITCHES/CONTROLS (1+1) NECITR-YTC
ART-FEB/04-01

•No 1 Power indicator


•Light When power switch is ON

MAINT LED
Maintenance Mode ON
Loopback control ON
CW mode ON
TX Power Mute ON
ALS MANUAL RESTART
ATPC MANUAL CONTROL
PWR SW
Turns input DC power ON/OFF ODU1 and ODU2 ALM LED
Transmit RF power decrease by 3 to 6 dB from nominal
Receiver level goes below squelch level
ODU local oscillator APC loop unlock
IF signal from the IDU is low

IDU1 and IDU2 ALM LED


R SW Input STM-1 Signal lost (from MUX ) -Main INTFC
Switch to previous program version after program update Input STM-1 Frame Sync lost (from MUX)- Main INTFC
Service Channel Input Signal Lost - Modem
CALL SW
E-BER worse than preset value (10-3 to 10-5) - Main INTFC
EOW calling signal,opposite station buzzer rings
BER-SD worse tha preset value (10-5 to 10-9) - Main INTFC
Input STM-1 Frame Sync lost from Radio - Modem
RESET SW E-BER from Radio worse than preset value (10 -3 to 10-5) -
Initialize CPU Main INTFC
BER-SD from Radio worse than preset value (10-3 to 10-5) -
Main INTFC
CPU of MD Unit failure - Modem
RX side alarms include unit failure and IF input loss - Modem
TX side alarms includes unit failure - Modem
BER alarm (10-4 to 10-6 selectable) - Modem
DC-DC CONV unit failure - DC-DC CONV
LAN CARD / WS INTFC Module failure - LAN /WS INTFC
Main INTFC Module failure - 150M INTFC/OPT INTFC

No.1 CH TX STATUS No.1 CH RX STATUS


Lights when Modulator and Transmitter of No.1 CH is selected Lights when Demodulator and Receiver of No.1 CH is selected

No.2 CH TX STATUS No.2 CH RX STATUS


Lights when Modulator and Transmitter of No.2 CH is selected Lights when Demodulator and Receiver of No.2 CH is selected

PASOLINK PLUS INTRODUCTION - STM1 22


INDICATORS/SWITCHES/CONTROLS (1+0) NECITR-YTC
ART-FEB/04-01

MAINT LED PWR LED


Maintenance Mode ON When power switch is ON

Loopback control ON
CW mode ON
TX Power Mute ON
ALS MANUAL RESTART ODU1 and ODU2 ALM LED
ATPC MANUAL CONTROL Transmit RF power decrease by 3 to 6 dB from nominal
Receiver level goes below squelch level
ODU local oscillator APC loop unlock
RESET SW IF signal from the IDU is low
Initialize CPU

R SW
R SW
Switch to previous program version after program update

CALL SW
EOW calling signal,opposite station buzzer rings

IDU ALM LED


Input STM-1 Signal lost (from MUX ) -Main INTFC
Input STM-1 Frame Sync lost (from MUX)- Main INTFC
PWR SW Service Channel Input Signal Lost - Modem
Turns input DC power ON/OFF E-BER worse than preset value (10-3 to 10-5) - Main INTFC
BER-SD worse tha preset value (10-5 to 10-9) - Main INTFC
Input STM-1 Frame Sync lost from Radio - Modem
E-BER from Radio worse than preset value (10 -3 to 10-5) -
Main INTFC
BER-SD from Radio worse than preset value (10-3 to 10-5) -
Main INTFC
CPU of MD Unit failure - Modem
RX side alarms include unit failure and IF input loss - Modem
TX side alarms includes unit failure - Modem
BER alarm (10-4 to 10-6 selectable) - Modem
DC-DC CONV unit failure - DC-DC CONV
LAN CARD / WS INTFC Module failure - LAN /WS INTFC
Main INTFC Module failure - 150M INTFC/OPT INTFC

PASOLINK PLUS INTRODUCTION - STM1 23


INDICATORS/SWITCHES/CONTROLS NECITR-YTC
ART-FEB/04-01

ALM LED (WS INTFC MODULE) ALM LED (150M INTFC/OPT INTFC)
WS INTFC Module fail Input STM-1 data signal is lost
Input STM-1 frame sysnchronization is lost
150M intfc/opt intfc module fail
E-BER alarm is detected
SD alarm is detected

ALM LED (LAN CARD MODULE)


LAN CARD MODULE FAIL
LINK LED (LAN CARD MODULE)
LIGHTS WHEN IDU AND
ASSOCIATED EQUIPMENT ARE
LINKED COLX/DUPLEX LED ( 10/100 BASE-T INTFC)
WHEN SETUP MODE IS HALF DUPLEX MODE, AND
COLLISION OCCURS
MEMORY OVERFLOW LED (LAN CARD MODULE)
LIGHTS WHEN THE MEMORY OF LAN CARD
MODULE OVERFLOW OR A COLLISION CONDITION
OCURS. 100M LED ( 10/100 BASE-T INTFC)
100 BASE-T TRANSMISSION IS USED

LINK/ACT LED ( 10/100 BASE-T INTFC)


ALM LED (WS/ALM INTFC MODULE) WHEN 10/100 BASE-T AND ASSOCIATED
WS/ALM INTFC FAILS EQUIPMENT IS LINKED. BLINKS WHEN DATA IS
CLOCK FOR CLUSTER ALARM IS LOST TRANSMITTED
FRAME SYNCHRONIZATION IS LOST

ALM LED (10/100 BASE-T INTFC)


10/100 BASE-T MODULE FAIL
RADIO FRAME SYNCHRONIZATION IS LOST
E-BER ALM IS DETECTED
SD ALM IS DETECTED
LINK OF PORT1/PORT2 IS LOST

PASOLINK PLUS INTRODUCTION - STM1 24


IDU (1+1) Interfaces & Connectors NECITR-YTC
ART-FEB/04-01
D-SUB 37 (FEMALE) SC IN / OUT
D-SUB 25 (FEMALE)
RJ45 RJ45 RJ45 RJ45 OH1(V11-1) IDT+ 1 20 OH1(V11-1)IDT-
ALM
PNMT LCT EOW1 EOW2 OH1(V11-1)ICK+ 2 21 OH1(V11-1)ICK-
1 14
PNMT DCD 1 1 EXT EOW1INPUT(+) 1 EXT EOW2OUTPUT(+) OH1(V11-1)IFP+ 3 22 OH1(V11-1)IFP-
ALM RL7 (NC) 2 15 ALM RL7 (COM)
PNMT TXD 2 LCT TXD 2 EXT EOW1 INPUT (-) 2 EXT EOW2OUTPUT (-) OH1(V11-1)DDT 4 23 OH1(V11-1)DDT-
ALM RL7 (NO) 3 16 ALM RL6 (NC)
3 EXT CALL2 OUTPUT OH1(V11-1)DCK+ 5 24 OH1(V11-1)DCK-
PNMT RXD 3 LCT RXD 3 EXT CALL1 INPUT ALM RL6 (COM) 4 17 ALM RL6 (NO)
4 EXT EOW2 INPUT(+) OH1(V11-1)DFP+ 6 25 OH1(V11-1)DFP-
PNMT DRS 4 4 EXT EOW1 OUTPUT(+) ALM RL5 (NC) 5 18 ALM RL5 (COM)
5 EXT EOW2INPUT(-) GROUND 7 26 GROUND
GND 5 GND 5 EXT EOW1 OUTPUT(-) ALM RL5 (NO) 6 19
6 GROUND OH2(V11-1)IDT+ 8 27 OH2(V11-1)IDT-
PNMT DTR 6 6 GROUND ALM RL4 (NC) 7 20 ALM RL4 (COM)
7 EXT CALL2 INPUT OH2(V11-1)ICK+ 9 28 OH2(V11-1)ICK-
PNMT CTS 7 LCT CTS 7 EXT CALL1 OUTPUT ALM RL4 (NO) 8 21 ALM RL3 (NC)
8 GROUND OH2(V11-1)IFP+ 10 29 OH2(V11-1)IFP-
PNMT RTS 8 LCT RTS 8 GROUND ALM RL3 (COM) 9 22 ALM RL3 (NO)
OH2(V11-1)DDT+ 11 30 OH2(V11-1)DDT-
10 23 ALM RL2 (NC)
OH2(V11-1)DCK+ 12 31 OH2(V11-1)DCK-
ALM RL2 (COM) 11 24 ALM RL2 (NO)
OH2(V11-1)DFP+ 13 32 OH2(V11-1)DFP-
ALM RL1 (NC) 12 25 ALM RL1 (COM)
GROUND 14 33 GROUND
ALM RL1 (NO) 13
OH3(VF-1) I/P+ 15 34 OH3(VF-1) I/P -
OH3(VF-1) O/P+ 16 35 OH3(VF-1) O/P -
OH4(VF-2) I/P+ 17 36 OH4(VF-2) I/P-
OH4(VF-2) O/P+ 18 37 OH4(VF-2) O/P-
GROUND 19
•EOW- Headset jack

LINE IN
•IF IN/OUT
1 0V or (+48V)
2 -48V or (0V)
3
4

AUX ALM D-SUB 25 (FEMALE)


HK1 Alm Input(+) 1 14 HK1 Alm Input(-)
•STM-1 IN/OUT HK2 Alm input(+) 2 15 HK2 Alm Input(-)
RJ45 RJ45 RJ45 D-SUB 9 (FEMALE) HK3 Alm Input(+) 3 16 HK3 Alm Input(-)
RJ45 RJ45
LAN CARD WS IN/OUT HK4 Alm Input(+) 4 17 HK4 Alm Input(-)
NE1 NE2 PNMS V11 PNMS LAN
MDI MDI-X 1 IDT(+) Input Data HK5 Alm Input(+) 5 18 HK5 Alm Input(-)
TXD+/RXD+ 1 TXD+/RXD+ 1 NMS TXD+ 1 NMS TD+
1 TX+ RX+ 2 Ground HK6 Alm Input(+) 6 19 HK6 Alm Input(-)
TXD-/RXD- 2 TXD-/RXD- 2 NMS TXD- 2 NMS TD-
2 TX- RX- 3 ODT(+) Output Data RL11(COM)HK1 7 20 RL11(NC HK1
RXD+/TXD+ 3 RXD+/TXD+ 3 NMS RXD+ 3 NMS RD+
3 RX+ TX+ 4/5 Ground RL10(NC)HK2 8 21 RL11(NO)HK1
CK + 4 N.C 4 4
6 RX- TX- 6 IDT(-) RL10(NO)HK2 9 22 RL10(COM)HK2
CK - 5 N.C 5 5
7 Ground RL9(COM)HK3 10 23 RL9(NC)HK3
RXD-/TXD- 6 RXD-/TXD- 6 NMS RXD- 6 NMS RD-
8 ODT(-) RL8(NC)HK4 11 24 RL9(NO)HK3
GND 7 GND 7
9 Ground RL8(NO)HK4 12 25 RL8(COM)HK4
GND 8 GND 8
Ground 13

PASOLINK PLUS INTRODUCTION - STM1 25


INTERFACES NECITR-YTC
ART-FEB/04-01

NEC PASOLINK PLUS SYSTEM HAS THE FOLLOWING ITU-T STANDARD INTERFACES
DIGITAL SIGNAL INTERFACES
• Main traffic STM-1 Electrical
Type (ITU-T G.703): in station section, full functionality
Bit Rate: 155.520 Mbit/s ± 20ppm
Level: 1 Vp-p (nominal) (TX accepts 12.7dB cable loss at 78 MHz)
Code Format: CMI
Impedance: 75 ohms, unbalanced (nominal)
Connector: IEC 169-13
• Main traffic STM-1 Optical
Type (ITU-T G.957): S-1.1 (Inter office)
Bit Rate: 155.520 Mbit/s ± 20ppm
Level: S-1.1 -8 to -15 dBm
Connector FC/PC

PASOLINK PLUS INTRODUCTION - STM1 26


INTERFACES NECITR-YTC
ART-FEB/04-01

• Wayside Traffic Transmission using RFCOH (option, 32QAM and 128QAM Enhanced Ver. only)
Bit Rate: 2.048 Mbit/s ± 50ppm/1.544 Mbit/s ± 130ppm
Input/output Level: 2.37 Vo-p 75 Ohms/3.0 Vo-p/3.0 v
(75 Ω unbal 2Mbit/s)(120 Ω bal 2Mbit/s)(100 Ω bal1.544Mbit/s)
Code format HDB-3/ AMI or B8Zs
Connector D-Sub 9 pin
• SOH Termination: RST
RF INPUT / OUTPUT PORT
Antenna direct mount type : 11-38 GHz NEC original interface
Coaxial interface type : 6-8 GHz SMA Coaxial Connector ( N-type optional)

Wave Guide interface type :


11 GHz :PDR100
13/15 GHz :PBR140
18/23 GHz :PBR220
26GHz :PBR260
38 GHz :PBR320

Polarization : Field changeable (Vertical or Horizontal) (Waveguide Type)


PASOLINK PLUS INTRODUCTION - STM1 27
SERVICE CHANNELS NECITR-YTC
ART-FEB/04-01

OVERHEAD SERVICE CHANNELS


1 EOW Analog Engineering Order Wire IDU-IDU, IDU-ODU, ODU-ODU Standard
2 V-11 Digital 64Kbit/s V11 (Contra / Co-directional selectable) Standard
3 V-11 100 Ohms, Balanced
4 VF1 Analog 4 wire , (0.3 ~ 3.4 KHz ) Standard
5 VF2 -6 dBm nominal , 600 Ohms, Balanced

6 WS or Digital 1.544 or 2.048 Mbps, RFCOH( 32 QAM /128 QAM Enhanced Ver. Option
only) or
7 LAN Digital Option
10 Base –T: 32 QAM use 2.048 RFCOH
128 QAM use DSC or RSOH(E1/F1) 64Kbps
128 QAM (Enhanced Ver) use 2.048 RFCOH

Service channels can be connected back-to-back at repeater stations.

Service channels 2 to 7 can be mapped to


DSC1 to DSC4 in the RFCOH and E1, F1 MUX PASOLINK+ PASOLINK+ MUX
and DCCr* bytes from the LCT or PNMT.
E1 (MUX) E1 (DMR) E1 (MUX)
F1 (MUX) F1 (DMR) F1 (MUX)
DCCr (MUX)* DCCr (DMR)* DCCr (MUX)*
DSC1 TO 4
* DCCr available only in STM-1, 128QAM Enhance ver. only
PASOLINK PLUS INTRODUCTION - STM1 28
START UP / SHUTDOWN NECITR-YTC
ART-FEB/04-01

No.1 CH Power Switch


No.1 CH Line IN

STAR UP
•Check that the LINE IN voltage is
between +20 V to +60V (or -20 V to -72
V) with a digital multi-meter, before
connecting the power connector to the
IDU
•Turn ON the Power switch on the IDU
•Allow equipment to warm up for at least 30
minutes

SHUT DOWN
•Turn OFF the power switch on the front of
the IDU No.2 CH Line IN
No.2 CH Power Switch

•The common unit is powered by both


IDU1 and IDU 2

PASOLINK PLUS INTRODUCTION - STM1 29


PROTECTION SWITCHING NECITR-YTC
ART-FEB/04-01

Protection switching is provided in (1+1) Twin Path and Hot Standby systems. The receive side protection switching is
performed by a Hitless Switch in the 150 M INTFC / OPT INTFC or 10/100BASE-T INTFC module.
Priority 1: Manual switching Control
Manual switching is initiated from external equipment (LCT/PNMT)
Priority 2: Automatic switching control
For any alarm in the online equipment, traffic will be switched to the standby equipment automatically. TX and
RX switchover are performed independently.
RX switching
TX switching
This apply to both HS and
In the (1+1)HS system Twin Path configurations.
transmit switching is carried When the Online RX CH fails
out by setting the standby or LOW BER Alarm is
ODU out put to off by Muting detected the ALM CONT
it. The data signal is circuit in the SW Board initiate
transmitted in parallel to both a RX SW Control signal to
CH1 and CH2. switch to the standby CH
provided it is in normal
operating condition.

TX Switching, either initiated Low BER Alarm


manually or automatically may FSYNC Alarm
cause a short interruption of
DEM Alarm
the data.
RX LEV Alarm
Modulator Alarm
TX IF Input Alarm SWITCHING PRIORITY ( Provisioning)
TX Power Alarm 1.Non-Priority The switching condition used is non priority (non-homing). After
APC Alarm switching the channel selected remains selected even if the
alarmed channel is normalized

2. Priority No.1 When both channels are normal always selects CH1 as online.
When CH1 is faulty automatically change to CH2 provided it is
normal. When CH1 recovers return to CH1 automatically.

PASOLINK PLUS INTRODUCTION - STM1 30


PROTECTION SYSTEMS NECITR-YTC
ART-FEB/04-01
AUTOMATIC LASER SHUTDOWN NECITR-YTC
ART-FEB/04-01

AUTOMATIC LASER SHUT DOWN FUNCTION

When the optical signal input to the main interface is lost, the ALS
function automatically shuts the main interface output laser

ALS DELAY TIME


The ALS delay time can be set to 60 or 180 or 300 sec.

PASOLINK PLUS INTRODUCTION - STM1 32


Automatic Transmit power control (ATPC) NECITR-YTC
ART-FEB/04-01

ATPC setting parameters:-


1- TX max. = Nominal – (0 ~ 20dB)
2- TX min. = Nominal – (0 ~ 20dB)
3- ATPC RX threshold (Reference ) = -30 ~-70dB
- ATPC will start with the TX min. power
- When the RX level of the opposite site is
decreased to be below the reference RX
- The ATPC Will start increasing the TX power up to
TX max. in one dB steps until increasing the RX
level of the opposite site to be over the reference
level
- The ATPC will maintain the RX level within 5 dB
over the reference level
TX
RX
IF
IDU ODU ODU
RX IDU
RF TX

Antenna Antenna TX max


TX max
TX min TX min
Site (A) Site (B)
RX reference RX reference
PASOLINK PLUS INTRODUCTION - STM1 33
AUTOMATIC TX POWER CONTROL NECITR-YTC
ART-FEB/04-01

Tx Out
High

Max. Tx Lev
(Provisioning)

Min Tx Lev
(Provisioning)
Low Fading
Deep Shallow
The ATPC Control transmits the information on the
receiving level to the opposite station and controls
Rx Lev
the transmission level of its own station in
High accordance with the receiving level of the opposite
station.

ATPC hysteresis
(provisioning)
ATPC Rx Threshold The ATPC Control can be used in several configurations:
(provisioning)

ATPC - ATPC
MTPC - ATPC
Low ATPC - MTPC
Deep
Fading
Shallow

PASOLINK PLUS INTRODUCTION - STM1 34


LOOPBACK CONTROL NECITR-YTC
ART-FEB/04-01

(d)

(a) STM-1 near-end loopback (STM-1 LB1) at the 150M INTFC/OPT INTFC module
(b) STM-1 far-end loopback (STM-1 LB2) at the 150M INTFC/OPT INTFC module from LCT
(c) IF loopback (IF-LB) at the MODEM module (Local only)
(d) STM-1 far-end loopback (STM-1 LB2) at the 150M INTFC/OPT INTFC Module from PNMT/PNMS

•Note: While the IF loopback is in execution, monitoring of the opposite and the subsequent stations from
the PNMS and PNMT are disabled.

PASOLINK PLUS INTRODUCTION - STM1 35


OW COMMUNICATION NECITR-YTC
ART-FEB/04-01

Back-to-back Buzz Buzz


Buzz connection
CALL

Following Order-Wire communications are possible:

Communication between Local IDU and Local ODU

Communication between Local IDU and Remote IDU


Communication between Local ODU and Remote IDU

Communication between Local ODU and Remote ODU


When the “Call” button on the IDU is pressed the
When back-to-back connection for order wire is provided, buzzer sounds on the remote IDU and all the other
OW communication between different hops are possible. IDUs connected through back-to back connections.

PASOLINK PLUS INTRODUCTION - STM1 36


EOW1 and EOW2 NECITR-YTC
ART-FEB/04-01

PASOLINK PLUS INTRODUCTION - STM1 37


OW/RX LEV MONITOR NECITR-YTC
ART-FEB/04-01

•Meter – Indicates the Receive


level as a dc voltage
•OW Indicator – Lights when the
OW-ON/OFF switch is set to ON.
Under this condition if the indicator
is not lit replace the battery.

•Battery – use 6F22(UB) / 9V battery

•Head set Jack – connects the


•OW ON/OFF SW – when set to ON headset for OW communication
enables OW communication
between the IDU and the ODU. •RX LEV/OW IN connector –
connect the OW/RX Lev monitor to
•VOL control – Adjust the level of the ODU using the provided coaxial
the OW RX signal. cable
PASOLINK PLUS INTRODUCTION - STM1 38
ALARM TABLE NECITR-YTC
ART-FEB/04-01

DETECTING CIRCUIT ALARM CONDITION MODULE LED ALM INITIATED LED INDICATION
INPUT STM-1 SIGNAL IS LOST FROM MUX ALM (150/OPT INTFC) MAIN INTFC LOS IDU 1 & 2 ALM
FRAME SYNCHRONIZATION OF INPUT STM-1 SIGNAL FROM MUX IS LOST ALM (150/OPT INTFC) MAIN INTFC LOS IDU 1 & 2 ALM
BER IS WORSE THAN PRESET VALUE (10 TO 10 SELECTABLE) FROM MUX SIDE
-3 -5
ALM (150/OPT INTFC) E-BER MUX IDU 1 & 2 ALM

BER IS WORSE THAN PRESET VALUE (10 TO 10 SELECTABLE) FROM MUX SIDE
-5 -9
ALM (150/OPT INTFC) SD-MUX IDU 1 & 2 ALM
RECEIVE STM-1 SIGNAL FROM RADIO IS LOST IDU 1 & 2 ALM
ALM (150/OPT INTFC) MAIN INTFC LOS DMR
FRAME SYNCHRONIZATION OF THE STM-1 SIGNAL RECEIVED FROM RADIO LINK IS LOST IDU 1 & 2 ALM
ALM (150/OPT INTFC) MAIN INTFC LOF DMR
150 / OPT INTFC
BER IS WORSE THAN PRESET VALUE (10 TO 10 SELECTABLE) FROM RADIO SIDE
-3 -5
ALM (150/OPT INTFC) E-BER DMR IDU 1 & 2 ALM

BER IS WORSE THAN PRESET VALUE (10 TO 10 SELECTABLE) FROM RADIO SIDE
-5 -9 ALM (150/OPT INTFC) SD DMR IDU 1 & 2 ALM

150M INTFC / OPT INTFC MODULE FAILURE ALM (150/OPT INTFC) MAIN INTFC IDU 1 & 2 ALM
COLX/DUPLEX(BLINK)
10/100BASE-T COLLISION CONDITION OCCURS (10/100BASE-T INTFC) COLLISION
INTFC ALM(10/100BASE-T
LINK OF LAN (10/100 BASE-T INTFC) AND ASSOCIATED EQUIPMENT IS NOT ESTABLISHED INTFC) LINK IDU 1 & 2 ALM
WSINTFC/LAN WS INTFC/ LAN CARD MODULE FAILURE ALM(WS INTFC/LAN) SUB INTFC IDU 1 & 2 ALM

COMMUNICATION BETWEEN MIODULES FAIL MD CPU ALM IDU 1 & 2 ALM

MODULATOR FAILURE MOD ALM IDU 1 & 2 ALM

MODEM DEMODULATOR FAILURE AND INPUT IF SIGNAL LOSS DEM ALM IDU 1 & 2 ALM

BER IS WORSE THAN PRESET VALUE (10-4 TO 10-6 SELECTABLE) FROM RADIO SIDE HIGH BERF ALM IDU 1 & 2 ALM

DC-DC CONV FAILURE PS IDU 1 & 2 ALM


MODEM FAILURE MODEM IDU 1 & 2 ALM

TRANSMIT RF POWER INCREASE/DECREASE BY APPROX. 3 dB FROM NOMINAL TX POWER ALM ODU 1& 2 ALM

TX IF SIGNAL FROM THE IDU IS LOST TX INPUT ALM ODU 1& 2 ALM
ODU
RECEIVER INPUT ;EVE; DECREASES BELOW SQUELCH LEVEL(32QAM -81dBm, 128 QAM -72 dBm) RX LEV ALM ODU 1& 2 ALM

APC LOOP OF THE LOCAL OSCILLATOR UNLOCK APC ALM ODU 1& 2 ALM

COMMUNICATION BETWEEN IDU AND ODU IS LOST CABLE ALM ODU 1& 2 ALM
WHEN EQUIPMENT IS SET TO ONE OR MORE OF THE FOLLOWING CONDITIONS

MAINTENANCE MODE
MAINTENANCE MAINT MAINT
FAR END / NEAR END LOOPBACK ON / ATPC MANUAL CONTROL

ALS MANUAL RESTART / MOD CW ON / MUTE ON (TX OUTPUT POWER MUTED)

PASOLINK PLUS INTRODUCTION - STM1 42


SUMMARY ALARM ITEMS NECITR-YTC
ART-FEB/04-01

SUMMARIZED EXTERNAL ALARMS AND HOUSE KEEPING CONTROLS


EVENT “ALM” CONNECTOR “AUX/ALM” CONNECTOR
RL-1 RL-2 RL-3 RL-4 RL-5 RL-6 RL-7 RL-8 RL-9 RL-10 RL-11
MAINT 
PS ALM  FACTORY DEFAULT SETTING
CPU ALM 
 CAN BE CHANGED
ODU ALM1 
 FACTORY DEFAULT FIXED
ODU ALM2 
CBL ALM1
CAN BE EITHER ALARM OR
CBL ALM2 CONTROL
TX PWR ALM 1 ONLY ALARMS
TX PWR ALM 2
TX IN ALM 1
TX IN ALM 2
RX IN ALM 1
RX IN ALM 2
APC ALM 1
APC ALM 2
IDU ALM 1 
IDU ALM 2 
MOD ALM 1
MOD ALM 2
DEM ALM 1
DEM ALM 2
SUB INTFC
MAIN INTFC
BER ALM 1 
BER ALM 2 
STM-1 LOS 
PORT 1&2, LINK DOWN 
HK CONTROL OUT 1 
HK CONTROL OUT 2 
HK CONTROL OUT 3 
HK CONTROL OUT 4 
Installations NECITR-YTC
ART-FEB/04-01

Before going to any site,


please be sure you completely prepared the following items:
1-The installation tools.
2-The test equipment ,materials ,and tools.( for test work
only)
3-Site installation drawings.
4-All labels/stickers (hard and soft copy)
5-Frequency plan and system configuration documents.
6-Test procedure and test data sheets .( for test work only)
7-Confirm access to site/station.
8-Check the condition of the vehicle to be used.
9-Make sure you and your staff are in good conditions
(physically)
10-Confirm the site/station entrance conditions.
11-Move to site/station safely.
PASOLINK PLUS INTRODUCTION - STM1 45
1-INDOOR
1-INDOOR Unpackingofof
Unpacking Unpacking
Unpacking Unpackingofof19"
19"
Accessories Unpacking
INSTALLATION
INSTALLATION Accessories ofofIDU
IDU rack(if
rack
NECITR-YTC
(ifsupplied)
supplied)
ART-FEB/04-01

IFConnector
IF Connector&&Power
Power
Connectortermination
termination Confirm 19" Rack Location
Connector
& DC-Power Source

19"rack
19" rackfixing
fixing
FollowThe
Follow The
terminationProcedure
termination Procedure IDU
Mounting
RackEarthing
Rack Earthing
Connection
Connection
Refer to the IDU fixing IFCable
IF Cable
Procedure Photos Connection
Connection

IDUGrounding
IDU GroundingConnection
Connection

Follow Start up and set up Connectthe


Connect thePower
Power
NESIC CAIRO
Procedure PASOLINK PLUS INTRODUCTION - STM1 46
IDU MOUNT NECITR-YTC
ART-FEB/04-01

FRONT POSITION
More than one
rack unit

WALL

Align the IDU to the mount position


When mounting the IDU in a 19 inch
rack, leave a space of 200mm to
Fix each side of the IDU to the rack
the rear section and space of one
with (M5) screws
rack unit to the top and bottom.
CENTER POSITION

More than one


rack unit
Mount the two brackets to the IDU
Align the IDU to the center mount position
with four screws
and fix each side with (M5) screws
PASOLINK PLUS INTRODUCTION - STM1 47
Cable Connection and Wiring NECITR-YTC
ART-FEB/04-01

-4 Put-6
Connect Connect-5
the
the IF the Power
Label
Cable Cable
s

Connect-3
the STM-1 Fix the 4-1
Connect the-2 Cable screw (2 for
frame Earthing each side)
PASOLINK PLUS INTRODUCTION - STM1 48
NECITR-YTC
ART-FEB/04-01

Luck Nut

Washer

Gasket

Clamp A

Clamp B

Insulation
Center
Conductor
Connector Shell
IF Cable Termination NECITR-YTC
ART-FEB/04-01

1-First, Fit the Lock Nut, Washer


and Gasket on the Cable as
shown

Gasket

washer
Lock Nut
PASOLINK PLUS INTRODUCTION - STM1 50
NECITR-YTC
ART-FEB/04-01

2-Strip Back the cable sheath,


taking care not to damage the
braided shield.

Fit Clamp A
PASOLINK PLUS INTRODUCTION - STM1 NESIC
51 CAIRO
NECITR-YTC
ART-FEB/04-01

3-Fold back the Braided shield,


Separating the strands of the braid.

Cut the
extra length,
to fit to
Clamp A

PASOLINK PLUS INTRODUCTION - STM1 52


NECITR-YTC
ART-FEB/04-01

4-Cut away the insulation


from the center conductor
and fit the clamp B.

Be sure not to cut or scratch


the conductor while
stripping the insulation

PASOLINK PLUS INTRODUCTION - STM1 NESIC CAIRO


53
NECITR-YTC
ART-FEB/04-01

5- Cut the center conductor to fit


the connector center contact
(~1.2cm). Taper the end of the center
conductor using a file
6- Mount the center contact onto
the center conductor

7- Mount the Insulation onto the Insulatio


center contact. n

PASOLINK PLUS INTRODUCTION - STM1 54


NECITR-YTC
ART-FEB/04-01

8-Insert the cable into the


connector shell

9- Tighten the Lock Nut.


Insure the good tighten
condition using the suitable
wrench

PASOLINK PLUS INTRODUCTION - STM1 NESIC CAIRO


55
10- Check the connector-cable
continuity suing multemeter. NECITR-YTC
ART-FEB/04-01

11- Cover the outdoor connector


with rubber tape.

12- Cover the rubber tape with all


weather vinyl tape.

13- The connector is ready for use.


PASOLINK PLUS INTRODUCTION - STM1
NESIC 56
CAIRO
POWER CABLE TERMINATION NECITR-YTC
ART-FEB/04-01

PASOLINK PLUS INTRODUCTION - STM1 57


CONNECTOR &POWER NECITR-YTC
ART-FEB/04-01

CABLE
Power
Connector

Socket Contact
Power
Cable
NECITR-YTC
ART-FEB/04-01

1-Remove 3.0 to 3.5 mm of Insulation 1

2
2- Set the socket contact to the following
position onto the hand crimping tool

Crimping Type dia. of Cable Position


Ф 1.5 to 1.8 1 57026-5000
Ф 1.8 to 2.2 2
Ф 2.3 to 2.6 1 57027-5000
Ф 2.6 to 3.1 2 Hand Crimping
tool (57026-5000)
PASOLINK PLUS INTRODUCTION - STM1 59
NECITR-YTC
ART-FEB/04-01

3- Squeeze the handle of the hand crimping tool, insert cable into socket
contact

4- Cable should fit, so insulation and bare wire are arranged as shown,

5- Squeeze the handle of the hand crimping tool until ratchet is released.

PASOLINK PLUS INTRODUCTION - STM1 60


NECITR-YTC
ART-FEB/04-01

Squeeze the-5
handle of the hand
crimping tool until
ratchet Is released

6- Insert socket contacts to power


connector till they locked and be sure
it is well fixed. )V 48-(

)V 0 (

PASOLINK PLUS INTRODUCTION - STM1 NESIC CAIRO


61
The Connector is ready to use NECITR-YTC
ART-FEB/04-01

PASOLINK PLUS INTRODUCTION - STM1 NESIC CAIRO


62
UNPACKING ODU NECITR-YTC
ART-FEB/04-01

6/7/8 GHz ODU 11- 38 GHz ODU


•Open the carton
•Open the carton
•Take out the ODU with cushioning materials
•Take out the ODU with the cushioning materials
•Remove the cushioning materials from the ODU
•Remove the cushioning material from the ODU
•Take out the ODU from the antistatic bag
•Inspect ODU
•Inspect ODU

PASOLINK PLUS INTRODUCTION - STM1 63


POLE MOUNTING BRACKET NECITR-YTC
ART-FEB/04-01

Bracket for 6/7/8 GHz Band ODU

New Type Bracket for 11-38 GHz Band ODU Old Type Bracket for 11-38 GHz Band ODU

PASOLINK PLUS INTRODUCTION - STM1 64


POLE MOUNTING BRACKET NECITR-YTC
ART-FEB/04-01

NEW TYPE BRACKET NEW TYPE BRACKET

PASOLINK PLUS INTRODUCTION - STM1 65


DIFFERENT ODU MOUNTINGS
NECITR-YTC
ART-FEB/04-01

PASOLINK PLUS INTRODUCTION - STM1 66


V /H POLARIZATION (1+1) NECITR-YTC
ART-FEB/04-01

V - POLARIZATION NEC Hybrid Quasar Hybrid


SCREWS

SCREWS

SCREWS

H - POLARIZATION ANTENNA
CONNECTION
UNIT

PROCEDURE FOR SETTING V/H POLARIZATION USING HYBRID

ANTENNA SIDE HYBRID SIDE


•The hybrid is set to V-polarization
•Loosen the four screws with allen keys and rotate
when shipped from the factory
the antenna connection unit to the required
polarization position •Remove the two screws.
•Tighten the four screws. •Rotate the two plates to the position required for
the required polarization and fix them in position
with the screws
PASOLINK PLUS INTRODUCTION - STM1 67
Antenna Direct Mount Type NECITR-YTC
ART-FEB/04-01

Remove the Blanking


plate

Mount the blanking plate


here for reuse

1.Mount the Hybrid to the Antenna with screws, use the 2.Fix the ODUs one by one to the Hybrid. Take care not
guide pins to position correctly to damage the o-rings.
PASOLINK PLUS INTRODUCTION - STM1 68
ANTENNA DIRECT MOUNT – V/H POL NECITR-YTC
ART-FEB/04-01

PROCEDURE FOR SETTING V/H POLARIZATION

•When vertical polarization is required, rotate the •When horizontal polarization is required, rotate the
IDU so that the plate marked with V is pointing up. IDU so that the plate marked with H is pointing up.
Fix the ODU in this position Fix the ODU in this position

PASOLINK PLUS INTRODUCTION - STM1 69


USE OF O-RINGS NECITR-YTC
ART-FEB/04-01

•Do not use both small O-ring and large O-ring


simultaneously

•O-ring size is different forf different frequency


bands

PASOLINK PLUS INTRODUCTION - STM1 70


POLE MOUNTING BRACKET NECITR-YTC
ART-FEB/04-01

PASOLINK PLUS INTRODUCTION - STM1 71


NECITR-YTC
ART-FEB/04-01

•For Andrew VHP( )-( )-NC3 Antenna

PASOLINK PLUS INTRODUCTION - STM1 72


6/7/8 GHz ODU CONNECTIONS NECITR-YTC
ART-FEB/04-01

USING NEC HYBRID USING QUASAR HYBRID

PASOLINK PLUS INTRODUCTION - STM1 73


Antenna connection using WG
NECITR-YTC
ART-FEB/04-01

Align the waveguide to the Hybrid’s


Antenna port and fix it with four bolts.
Take care not to damage the O - ring

PASOLINK PLUS INTRODUCTION - STM1 74


WAVEGUIDE CONNECTION TYPE ODU
NECITR-YTC
ART-FEB/04-01

Align the waveguide to the ODU Wave


guide flange fix with four bolts.
Take care not to damage the O - ring

PASOLINK PLUS INTRODUCTION - STM1 75


GROUNDING NECITR-YTC
ART-FEB/04-01

PASOLINK PLUS INTRODUCTION - STM1 76


3- IDU Start up NECITR-YTC
ART-FEB/04-01

1-Be sure the power cable and IF cable are connected in


Proper way
2- Carefully Poll out the Power On / Off toggle switch and put
in ON position.
2- To shutdown the IDU switch the toggle switch to Off
Position

1-Never switch IDU Off before at least 30 sec


2-Never connect or disconnect the IF Cable
while the equipment is powered On
3-Leave the equipment to warm up
PASOLINK PLUS INTRODUCTION - STM1 77
4- Equipment setting and test NECITR-YTC
ART-FEB/04-01

1- Set the HyperTerminal on your PC as follows :-


From start menu follow the route
Programs…..Accessories….Communication…… HyperTerminal
HyperTerminal
You will need to set only one time

PASOLINK PLUS INTRODUCTION - STM1 78


HyperTerminal setting NECITR-YTC
ART-FEB/04-01

1- Double click HyperTerminal icon and follow the instructions


Type your
Connection
Name

PTT

Select connect using


“direct to COM1”

PASOLINK PLUS INTRODUCTION - STM1 79


HyperTerminal setting NECITR-YTC
ART-FEB/04-01

Select the setting items:


1-Bits/Second:
19200

2-Data Bits
8

3-Parity
None

4-Stop bits
1

5-Flow Control
6- Press OK
Hardware
NESIC CAIRO
PASOLINK PLUS INTRODUCTION - STM1 80
HyperTerminal setting NECITR-YTC
ART-FEB/04-01

From File menu select “


Properties” 1-Select
“Terminal
keys”

2-Select
“VT100”

VT100

500
3-Press
“ASC II setup

Wrap lines
that exceed
7- OK 8- OK
terminal width NESIC CAIRO
PASOLINK PLUS INTRODUCTION - STM1 81
IDU Setting NECITR-YTC
ART-FEB/04-01

• Connect your PC to the IDU


using supplied RS232 cable.
• Start up your HyperTerminal
connection
• Follow the Commands as
– Enter Login Name : Admin
– Enter Password : 12345678
– Main Menu will appear as
shown in below fig. Double
Click

1-Press 4
System
Configuration

PASOLINK PLUS INTRODUCTION - STM1 NESIC 82


CAIRO
IDU Setting NECITR-YTC
ART-FEB/04-01

This setting is just for test purpose


• From System Configuration
For more
menu select 2 details, please refer to instruction manual

2- Setup Radio
equipment
Configuration

Enter TX
Frequency & Press
Enter Key

Select TX Power
Control to MTPC &
Press Enter Key

PASOLINK PLUS INTRODUCTION - STM1 NESIC83CAIRO


NECITR-YTC
ART-FEB/04-01

Select Frame ID &


Press Enter Key

Select Main
Interface & Press
Enter Key

PASOLINK PLUS INTRODUCTION - STM1 84


IDU Setting NECITR-YTC
ART-FEB/04-01

• Start your antenna orientation


and link test.

1- At each station,
press the “9” key
twice for setting
the
Antenna Alignment
mode of
“Maintenance” and
press the
“Enter” key,

PASOLINK PLUS INTRODUCTION - STM1 NESIC85CAIRO


Antenna Orientation NECITR-YTC
ART-FEB/04-01

At each station remove the cap from the RX LEV MON connector.
At each station connect cable between the RX LEV MON
connector in the ODU and OW/RX LEV IN connector in the OW/
RX LEV MONITOR unit or digital multi-meter.
Adjust the azimuth and the elevation so as to maximize the RX
LEV voltage indicated on the voltage display, one station at a
time.

AZ Angle Adjustment EL Angle Adjustment


1. Loosen the Bolt (Nut) 3. Loosen Bolts
2-1. Adjust AZ angle by the two Bolts (nuts)
2-2. Secure the Bolts (nuts). 4. Adjust EL angle by the bolts (nuts)
Secure the Bolts (nuts).
After adjustment disconnect the RX LEV MONITOR /Digital Multi-meter
Put back the cap on the RX LEV MON connector

NEW TYPE BRACKET


PASOLINK PLUS INTRODUCTION - STM1 86
ORDER-WIRE TESTS
NECITR-YTC
ART-FEB/04-01

Connect the OW/RX LEV MONITOR to the RX LEV


MON connector on the ODU.
Connect Headsets to the EOW Jacks on the front
panel of the local and remote IDUs and Headset
Jack on the OW/ RX LEV MONITOR.
Press the Call Button on the local IDU and confirm
that the buzzer on the opposite IDU is activated..
Confirm that OW communication between Local IDU
and the Remote IDU is possible.
Confirm that OW communication between Local IDU
and the local ODU and/ or opposite ODU is possible
Confirm that OW communication between Local
ODU and the opposite ODU is possible
Disconnect the headsets and OW/RX LEV monitors.

PASOLINK PLUS INTRODUCTION - STM1 87


LCI to RS232 NECITR-YTC
ART-FEB/04-01

PASOLINK PLUS INTRODUCTION - STM1 88


RX Level Monitoring
NECITR-YTC
ART-FEB/04-01

Low BER and High BER are fixed to 3 x 10-7 and 3 x 10-4.
PASOLINK PLUS INTRODUCTION - STM1 89
Network connections NECITR-YTC
ART-FEB/04-01

PASOLINK PLUS INTRODUCTION - STM1 90