You are on page 1of 4

Fig.3.

Schematic diagram of tested model and test stand


Displacements

tĞůĚŝŶŐ ƟŵĞ ƐĞĐ


Current intensity
No. of run
Specimen

Gauge 1

Gauge 3
Gauge 2
Voltage

[mm]
[mm]

[mm]
U [V]

I [A]
1 1 27,5 184 33,2 1,76 1,73 1,21
2 27,7 175 20,1 4,85 5,71 4,99
2 1 26,7 172 34,9 1,76 1,60 1,99
2 26,5 173 38,5 4,87 4,90 5,57
3 1 26,5 185 43,7 1,41 1,97 1,98
2 26,8 174 39,8 4,11 4,98 4,20
4 1 26,7 182 46,2 1,65 1,71 2,04
2 27,2 170 34,3 4,31 4,41 4,82
5 1 26,9 185 37,4 1,56 1,79 1,89

2 27,2 170 45,6 4,45 5,01 4,95

Fig. 5. Nomogram for determining the angular distortion β [4]


Obtained angular Deviation from the
Method distortion [°] mean value from the
experiment [%]

No.1 [12] 3,30 +38

No. 2 [11] 2,20 -8

No. 3 [4] 2,94 +23

No. 4 [2] 2,75 +15

No. 5 [5] 2,98 +25

Experiment ( mean 2,39


value of 5 tests)