You are on page 1of 1

MICROCONTROLLER BASED DIGITAL LOAD INDICATOR

SPECIFICATIONS :

Indication : 5 Digits with Auto Polarity Red LED Display of 12.5mm


character height.
Input Calibration : LOAD CELL .
Load Cell Excitation : Instrument will provide 10 V DC. for Load cell excitation.
Range : Please specify.
Indicating Accuracy : ±0.1% of full scale.
Resolution : 10000 count.
Open Sensor Indication : Indicated by Data Field as `SORRY'.
Zero & Tare : Full Range Push Button Zero & Tare key provided.
Peak Hold / Normal : At Power applied default will be NORMAL mode, Pressing
this switch it will be convert to PEAK HOLD mode.
Kgf. / Newton : At Power ON default will be KGF mode, Pressing this
switch it will be convert to NEWTON mode.
Compression / Tension : At Power ON default will be COMPRESSION mode while
pressing this switch it will be convert to TENSION mode.
Size : 92mm (w) x 92mm (h) panel cut out with 140mm depth.
Bazel size 96mm (w) x 96mm (h) of ABS cover with MS
powder coated box.

Manufactured by :

962, G.I.D.C. ESTATE, MAKARPURA,


ANALOG & DIGITAL VADODARA - 390 010 (INDIA)
Tele Fax :(91) 0265- 2655081/2655082
E-mail : contact@adicontrols.com
INSTRUMENTATION adicontrols@adicontrols.com
Website : www.adicontrols.com

You might also like