The document summarizes calculations to check the capacity of lag screws, Hilti anchors, and a parapet wall based on load reactions from a structural analysis (RISA). It is determined that the shear capacity of lag screws is insufficient, while Hilti anchors and the parapet wall meet capacity requirements. Tables of allowable loads for different anchor and fastener sizes are also provided.
The document summarizes calculations to check the capacity of lag screws, Hilti anchors, and a parapet wall based on load reactions from a structural analysis (RISA). It is determined that the shear capacity of lag screws is insufficient, while Hilti anchors and the parapet wall meet capacity requirements. Tables of allowable loads for different anchor and fastener sizes are also provided.
The document summarizes calculations to check the capacity of lag screws, Hilti anchors, and a parapet wall based on load reactions from a structural analysis (RISA). It is determined that the shear capacity of lag screws is insufficient, while Hilti anchors and the parapet wall meet capacity requirements. Tables of allowable loads for different anchor and fastener sizes are also provided.
Allowable tension per 1/2" screw: 813 lbs 0.836 Tension OK
Shear per screw: 379 lbs
Allowable shear per 1/2" screw: 170 lbs 2.232 NG
t/T + v/V = 5.679 NG
Check Hilti Anchor - Mast to Masonry
Reactions from RISA - Worst Case Rx (tension): 3749 lbs Ry (shear): 133 lbs Rz (shear): 4264 lbs
Hilti qty at each support: 4
Tension per Hilti: 937 lbs
Allowable tension per 5/8" Hilti: 1025 lbs 0.914 Tension OK
Shear per Hilti: 1067 lbs
Allowable shear per 5/8" Hilti: 1405 lbs 0.759 Shear OK
t/T + v/V = 1.673 NG
Check Stress on Parapet Wall
Parapet Height: 3.5 ft Top of Parapet to 1st Support: 1 ft Distance Between Supports: 1 ft Distance between Masts: 5 ft Wall Thickness: 8 in Wall Effective Width: 5 ft Wall Area: 3.3 sf Section Modulus of Wall: 640 in3
Lateral Force at Top: 842 lb
Lateral Force at Bottom: 583 lb Axial Force at Top: 225 lb Axial Force at Bottom: 0 lb
Moment on Wall: 1231 ft-lb
Lateral Stress on Wall, M/S: 23.1 psi Allowable Stress on Wall: 30 psi OK
Weight of Wall: 1575 lbs
Axial Load on Wall: 1800 lbs Axial Stress on Wall, P/A: 3.8 psi Allowable Axial Stress: 100 psi OK