MOMENTUM CALCULATIONS

Flow rate, Density, Nozzle id, Momentum,


kg/h kg/m3 mm Pa
Gas1 383542 20 575 8417
Gas2 0 0
Liquid1 0 0
Liquid2 0 0

Momentum, Pa Inlet Device


<1400 Not required
1400-2100 Half-open pipe
>2100-8000 Vane type
Momentum outlet nozzle, Pa < 3750
For inlet momentum above 8000 Pa increase the nozzle id.

Above criteria is taken from


Shell DEP 31.22.05.11-Gen.
December 2007, page 79.