You are on page 1of 2

Field Service Report of HKK Centrifuge

To : Life-Science Instruments Division, Hitachi Koki Co., Ltd.

Issuing date : 05/JUNE/2018


Issued by :      
Company : PT INDOTECH SCIENTIFIC
Ref. No :      

Name of the End User PT UNILAB PERDANA

Jalan Ciledug Raya No.10, RT.11/RW.11, Cipulir Kebayoran Lama, Kota Jakarta Selatan, 12230
Address
Country [ INDONESIA                ]
Date of your visit to
Date of the incident (dd/mmm/yyyy) 23 / MAY / 2018 follow up the (dd/mmm/yyyy) 04 / JUNE / 2018
incident
EXPLODED                                          
Outline of the incident
Alarm No. [      ]

Centrifuge Model CT6E MGF No. 905600 Rotor Model T6AP S/N A711

ROM Revision
      Condition of Room Temp       °C  Power source214V
(Program Revision)
Within the warranty
Date of installation (dd/mmm/yyyy) 08 / MAY / 2018 Warranty Period
Out of warranty
Speed [5000] rpm Time [ 00:10 ] (hrs : min) Temp [       ] °C Accel FAST DecelFAST
Set Run condition
Was the centrifuge under this condition first time or routine work? First time Routine work
Detail of Incident
Please describe details about the incident and its background in chronological order.
User was using centrifuge to separated colloid in N total analysis which consist of H2SO4 5ml in 20 ml sample with 5000 rpm in 10
minutes setting program. Before exploded they were analyze 2 times same sample in same day. Usually this centrifuge using for
separation in environment sample such as metal analysis and acidic analysis.

Action you took on site


PULL OUT ELECTRICAL SOCKET. When training, our trainer already told user that we are not recomend for use plastic tube for acid
sample.

Total number of revolution       Total number of the running      


Run History of centrifuge
Total running hours       Total number of the door opened      
-
Maintenance History
(Which part was replaced in the past ?
When was it replaced?)

Measured Temperature, Speed, Time and Speed [5000] rpm Time [ 00:10:     ] (hrs: min: sec) Temp [       ] °C
Running condition when the incident happened Running condition: In Acceleration Running at set speed In Deceleration
Please take photo of Alarm History Screen and attach them to this report in PDF.
Alarm history
     
Please check following points with the end user;
Was the incident reproduced? Yes No
Did the incident occur in the combination with the rotor? Yes No
Were the tubes/bottles set in the symmetrical position? Yes No
Were the pair of tubes/bottles in symmetrical position well balanced? Yes No

To be continued to the next page


Tube/Bottle: Part No. [ 2345-050 ] Description POLYPROPYLENE TUBE V BOTTOM
Tube/Bottle/Adapter Model
WITH PE CAP (Third party IWAKI )
Part No., Description and manufacturer (if the
Adapter : Part No. [       ] Description      
tube is made by a third party) are required
Cap : Part No. [       ] Description      
If the user has other rotors, please specify their no
model name and serial number as well .
Rotor’s run history Total running hours       Total number of the running      
Life of Rotor Within the primary life Within the secondly life Out of the secondly life
Quantity of sample 20 ml × 8 pcs = 160 ml

Sample Name             Density       Weight       (g/tube) pH      


Please describe the compositions of the sample with each composition’s volume and density as much as possible

Composition of the sample solution


Composition 1 [ Soil ampel ] / concentration [       % ] / volume [       ml ]
Composition 2 [ HNO3 ] / concentration [       % ] / volume [       ml ]
Composition 3 [ HCLO4 ] / concentration [       % ] / volume [       ml ]
Composition 4 [ KCL ] / concentration [       % ] / volume [       ml ]
Composition 5 [       ] / concentration [       % ] / volume [       ml ]
How did the user usually use /run the centrifuge/rotor?
(Please check the user’s procedure to use /run the centrifuge/rotor.
Especially, whether the user took any special process which is not mentioned in the operating manual.)
twice, at least already separated 200 sample

Please indicate parts to be returned to HKK and their quantity.


Parts to be returned
     
to HKK

Please make sure that the returning parts should be decontaminated before the shipment and attach the decontamination sheet to the
package.

Please return to : Hitachi Koki Co., Ltd.


Katsuta Plant
Life-Science Instrument Division
Production Planning Team
1060 Takeda, Hitachinaka
Ibaraki 312-8502 JAPAN

For internal use at HKK

Date of receipt

Person-in-charge

You might also like