81. In power reversal of HVDC line:->Direction of current in de link is maintained in the sate direction,
but the polarity of the conductor is reversed
82. The desired features of HVDC control do not include:-=Improving the load factor
83. current control is done at rectifier end because:->At low aplpha pf is improved
84. In a HVDC link:->The roles of converter and inverter may be interchanged
85. In a HVDC link:->The current is never reversed
86. Which of the following statements is correct:->Current control is done at rectificr end and voltage
control at inverter end
87. If Q is odd, maximum inverse voltage occurs with a phase shift of rating-will be :->#/q AND -/q
88. Reliability of HVDC transmission is, compared to HVAC transmission :->less
89. current control is done at rectifier end because:->at low alpha is improved
90. Current margin is:->Difference between current setting of rectifier and inverter
91. current control is done at rectifier end because:->fault current can be limited by advancing alpha
92. To control power transfer in HVDC link:->ALPHA on rectifier side is changed
93. Voltage dependent current order limit (VDCOL ) is resorted to when:->AC system voltage is low and DC
currents high
94, which of the following statements is correct:
control at inverter end
95. To control power over a HVDC link:->Both voltage and current are controlled
96. To control power over a HVDC link:->Firing angle is controlled -
97. What is he range of + of a greatz circuit:->0 to 180°
98. The transmission cost increases with :->inerease in power level
99. To control power transfer in HVDC link:->all the above
‘current control is done at rectifier and and voltage
100. After inverter and rectifier starting procedure is completed:->Current is raised slowly to the rated
value
101. __ To operate HVDC system so that power factor on the ac system will be high:-> Alpha should be
minimum on rectifier side , gama should be minimum on the inverter side
102. To operate HVDC system so that power factor on the ac system will be high:->Alpha should be
minimum on rectifier side , gama should be minimum on the inverter side
103. The gate pulses are applied to the thyristor valves of HVDC converters by:->Fiber optic link
104. ‘The 12-pulse converter operation can be divided into__ modes:->5
105. The valve utilization factor is defined as ratio of ___ values:->PTV and Avg. DC
106. ‘The group of valves in which only one conducts at a time is defined as:->commutation group
“The valve ratings are specified in-terms-of ——->PEV—
108. When the converter acts as an inverter.->if the de voltage is negative
109. ‘The advantage(s) of DC transmission line is(are) :->Full control over power transmission AND
Full control over power transmission
110. Which of the following statements is does not correct?:->all
11 The frequency of ripple is not determined by Dall
112. The commuteting resistance is equivalent to. reactance & Re= _:->armature reaction, 6fLe
113. The mode of operation of Graetz circuit with overlap is valve conduetion:->2 AND 3
114 The pulse number of a simple 3 phase full converter is >pulse number
115. ‘The pulse number of a simple 3 phase full converter is ->6
116. Foul weather conduction of overhead line causes radio interference to:->Decrease in AC lines and
increase in DC lines
117 ‘Smoothing reactors in HVDC systems are used:->In each pole of the converter on DC side
118 is a source of reactive filter:->AC filter
119. Which of the following parameter overlap ocours:->leakage inductance “
120, ‘The corona losses is in de line as compared to ac line :->less
121. The valve voltage ratings are not specified in terms of. all
122. The Vd is equal to (for Graetz circuit Without overlap) >Va, cos
123 ‘The TUF can be improved if __valve groups can share _T/F windings: