You are on page 1of 3

ITV Series 2/18/99 4:37 PM Page 1

∗∗

SMC REGULATOR

ITV2000

Electro-Pneumatic Regulator
Series ITV2000/3000
Standard Specifications

ITV201m ITV203m ITV205m


Model
ITV301m ITV303m ITV305m
Minimum supply pressure Set pressure +0.1MPa
AC
Maximum supply pressure 0.2MPa 1.0MPa
Regulating pressure range 0.005 to 0.1MPa 0.005 to 0.5MPa 0.005 to 0.9MPa
AV
Voltage 24V DC ±10%, 12 to 15V DC
AU
Power supply Current Power supply voltage 24V DC type: 0.12A or less
consumption Power supply voltage 12 to 15V DC type: 0.18A or less
(1)
Current type 4 to 20mA, 0 to 20mA
AF
Input signal Voltage type 0 to 5V DC, 0 to 10V DC
Preset input 4 points
AR
Current type 250Ω or less
Input
Voltage type Approx. 6.5kΩ
IR
Straight type Right angle type impedance
Preset input Approx. 2.7kΩ
VEX
Analog 1 to 5V DC (load impedance: 1kΩ or more)
(2)
Output signal output 4 to 20mA (sink type) (load impedance: 250Ω or less)
(monitor output) Switch
AW
NPN open collector output: Max. 30V, 30mA
output PNP open collector output: Max. 30mA
Symbol Linearity Within ±1% (full span)
AMR
Hysteresis Within 0.5% (full span)
AWM
Repeatability Within ±0.5% (full span)
Sensitivity Within 0.2% (full span)
AWD
Temperature characteristics Within ±0.12% (full span)/°C
Accuracy ±3% (full span)
Output
pressure display Minimum unit
ITV
MPa: 0.01, kgf/cm2: 0.01, bar: 0.01, PSI: 0.1 (3), kPa: 1
Ambient and fluid temperature 0 to 50°C (with no condensation)
VBA
Enclosure IP65 equivalent
ITV20mm 350g
Weight VE
ITV30mm 645g
Note 1) 2 wire type 4 to 20mA is not available. Power supply voltage (24V DC or 12 to 15V DC) is required.
Note 2) Select either analog output or switch output.
VY
Further, when switch output is selected, select either NPN output or PNP output.
Note 3) The minimum unit for ITV205m is 1PSI. G
How to Order AL

ITV 3 0 1 0 0 1 2 S
Model Pressure
Pressure range display unit
2 2000
3000 1 0.1MPa – MPa
3
3 0.5MPa 2∗ kgf/cm2
Power supply 5 0.9MPa 3∗ bar
voltage 4∗ PSI
24V DC Input signal 5∗ kPa
0
∗ Option
1 12 to 15V DC 0 Current 4 to 20mA
1 Current 0 to 20mA Cable connector type
2 Voltage 0 to 5V DC S Straight type 3m
3 Voltage 0 to 10V DC L∗ Right angle type 3m
4∗ Preset input N∗ Without cable connector
∗ Option ∗ Option
Monitor output Bracket
0∗ None (for preset input) Thread type
Without bracket

1 Analog output 1 to 5V DC – Rc(PT) Port size B∗ Flat bracket
2∗ Switch output/NPN output N∗ NPT 2 1/4 (2000, 3000) C∗ L-bracket
3∗ Switch output/PNP output T∗ NPTF 3 3/8 (2000, 3000) ∗ Option
4∗ Analog output 4 to 20mA F∗ G(PF) 4 1/2 (3000)
∗ Option ∗ Option 1.12-1
ITV Series 2/18/99 4:37 PM Page 5

∗∗

Electro-Pneumatic Regulator Series ITV2000/3000


Series ITV203m

Linearity Hysteresis Repeatability


0.6 1.0 1.0

0.5

Output deviation factor (%F.S.)


Output deviation factor (%F.S.)
0.5 0.5
0.4
Set pressure (MPa)

Out

0.3 0.0 0.0


Return
0.2
–0.5 –0.5
0.1
AC
0.0 –1.0 –1.0
0 25 50 75 100 0 25 50 75 100 0 2 4 6 8 10
Input signal (%F.S.) Input signal (%F.S.) Count AV
AU
Pressure characteristics Set pressure: 0.2MPa Flow characteristics Supply pressure: 0.7MPa Relief flow characteristics Supply pressure: 0.7MPa
1.0 0.6 0.8 AF
0.7
Output deviation factor (%F.S.)

0.5
0.5 0.6 AR

Set pressure (MPa)


Set pressure (MPa)

Set point 0.4


0.5

0.0 0.3 0.4 IR


0.3
0.2 VEX
–0.5 0.2
0.1
0.1 AW
–1.0 0.0 0.0
0.2 0.4 0.6 0.8 0 500 1000 1500 2000 0 500 1000 1500 2000
Supply pressure (MPa) Flow rate (l/min (ANR)) Flow rate (l/min (ANR))
AMR
AWM

Series ITV303m AWD


ITV
Linearity Hysteresis Repeatability
0.6 1.0 1.0 VBA
0.5
VE
Output deviation factor (%F.S.)
Output deviation factor (%F.S.)

0.5 0.5
0.4
Out
Set pressure (MPa)

0.3
VY
0.0 0.0
Return
0.2 G
–0.5 –0.5
0.1
AL
0.0 –1.0 –1.0
0 25 50 75 100 0 25 50 75 100 0 2 4 6 8 10
Input signal (%F.S.) Input signal (%F.S.) Count

Pressure characteristics Set pressure: 0.2MPa Flow characteristics Supply pressure: 0.7MPa Relief flow characteristics Supply pressure: 0.7MPa
1.0 0.6 0.8
0.7
Output deviation factor (%F.S.)

0.5
0.5 0.6
Set pressure (MPa)
Set pressure (MPa)

Set point 0.4


0.5

0.0 0.3 0.4

0.3
0.2
–0.5 0.2
0.1
0.1

–1.0 0.0 0.0


0.2 0.4 0.6 0.8 0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000
Supply pressure (MPa) Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

1.12-5
ITV Series 2/18/99 4:37 PM Page 6

∗∗

Series ITV2000/3000
Series ITV205m

Linearity Hysteresis Repeatability


1.0 1.0 0.5
0.9
0.8 Out

Output deviation factor (%F.S.)


Output deviation factor (%F.S.)
0.5 0.25
0.7
Set pressure (MPa)

0.6
0.5 0.0 0
0.4 Return

0.3
–0.5 –0.25
0.2
0.1
0.0 –1.0 –0.5
0 25 50 75 100 0 25 50 75 100 0 2 4 6 8 10
Input signal (%F.S.) Input signal (%F.S.) Count

Pressure characteristics Set pressure: 0.4MPa Flow characteristics Supply pressure: 1.0MPa Relief flow characteristics Supply pressure: 1.0MPa
1.0 1.0 1.0
0.9 0.9
Output deviation factor (%F.S.)

0.8 0.8
0.5

Set pressure (MPa)


0.7
Set pressure (MPa)

0.7
Set point
0.6 0.6
0.0 0.5 0.5
0.4 0.4
0.3 0.3
–0.5
0.2 0.2

0.1 0.1
–1.0 0.0 0.0
0.4 0.6 0.8 1.0 1.2 0 500 1000 1500 2000 2500 0 500 1000 1500 2000 2500
Supply pressure (MPa) Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

Series ITV305m

Linearity Hysteresis Repeatability


1.0 1.0 1.0
0.9
0.8
Output deviation factor (%F.S.)

Output deviation factor (%F.S.)

0.5 0.5
0.7 Out
Set pressure (MPa)

0.6
0.5 0.0 0.0
0.4 Return
0.3
–0.5 –0.5
0.2
0.1
0.0 –1.0 –1.0
0 25 50 75 100 0 25 50 75 100 0 2 4 6 8 10
Input signal (%F.S.) Input signal (%F.S.) Count

Pressure characteristics Set pressure: 0.4MPa Flow characteristics Supply pressure: 1.0MPa Relief flow characteristics Supply pressure: 1.0MPa
1.0 1.0 1.0
0.9 0.9
Output deviation factor (%F.S.)

0.8 0.8
0.5
Set pressure (MPa)

0.7 0.7
Set pressure (MPa)

Set point
0.6 0.6
0.0 0.5 0.5
0.4 0.4
0.3 0.3
–0.5
0.2 0.2
0.1 0.1
–1.0
0.0 0.0
0.4 0.6 0.8 1.0 1.2 0 1000 2000 3000 4000 5000 60007000 0 1000 2000 3000 4000 5000 6000
Supply pressure (MPa) Flow rate (l /min (ANR)) Flow rate (l /min (ANR))

1.12-6