Hisense A/C Product Line Up Introduction

for UAE market

1/24
1/36
CONTENT
• Ducted Split ( R410A )
• Cassette Type (R22)
• Floor standing A/C (R22)
• Package Unit ( R410A)
• Air Handling Unit

2/36
Light Commercial On-Off Type T3
• 1、Duct Type Introduction

• 2、Cassette Type Introduction

Special design for Restaurant、


Hotel、Apartment、Shopping

Mall , etc.
Flexible Indoor type are suitable
for all kinds of room size.

Rapid cool and heating,will give


you a comfortable and quiet
environment.

3/36
Outdoor Unit Appearance

18k 24k

48k/60k
36k

4/36
Indoor Unit Appearance

18k 24k 36k/48K/60K

18k 24k/36k 48K/60K

5/36
Wide Operating Range

6/36
Duct Type Introduction

7/36
High Efficiency

360° high efficiency twin rotary & Scroll compressor

Twin rotary (18~36K) Scroll(48~60K)

8/36
Design, installation convenience

High different height & long piping design, make installation more convenient

9/36
Slim Design
Advantage Hotel Room
Card Control

Galvanized steel
Fire Control
appearance

Drain pan
Absorb plastic foam I Feel
Structure Control
Dual Core
Built in Drain pan PCB Board
Cooling
System Intelligent
Water level Switch Defrost

Optional ODU Quiet


Static Pressure Operation

R401A ODU 3 Fan Speed


Refrigerant

10/36
Slim Design

With a height of 190mm may be


easily installed inside the low
height residential ceiling.

190mm

11/36
Galvanized Steel Appearance

Duct structure are all adopt galvanized steel design:

Advantages:
1, High strength, no deformation, durable
2, Fire prevention

12/36
Drain Pan Absorb Plastic Foam

Drain pan: after the completion of the


foam molding, vacuum forming,
increase a diaphragm in internal drain
pan, make condensation water flow
smoothly in drain pan, great helpful
for drainage. The EPS’s rusty &
insulation performance is good.

Advantages:
Never rust,
Excellent insulating performance

13/36
Built-in Drain Pan

Built-in Drain Pan Outside Drain Pan

Disadvantage of outside drain pan:It is easy to adhere dust


and bacterium. Easily cause drain dirty and leakage.

Hisense built-in drain pan design: will avoid the dirty and
leakage efficiently

14/36
Optional Static Pressure

18k: optional 10Pa & 30Pa static pressure,One unit, Two installation method
10Pa: No duct,straight blow
30Pa: External duct placed on air discharge

Front Blow, bottom air intake Front Blow, back air intake

Above two kinds of design (straight blow/external duct), without changing


equipment, just make wiring connection as 30 Pa static pressure wiring way.
Note: Default Settings is 10 Pa by factory.

16/36
Optional Static Pressure

24K & 36K: 50Pa/80Pa


48K/60K: 80Pa/120Pa

According to the actual situation to connect external duct,


with different outlet, will give people more convenience and
comfortable.

17/36
Centrifugal fan

New Hisense new centrifugal fan, will provide higher static pressure overcome
wind resistance.

Hisense new centrifugal fan Cross Fan

 Low noise centrifugal fan design, will offer high static pressure, and
cross fan, zero static pressure, blowing distance is short.
 Low noise centrifugal fan design will avoid heating issue because
hot air is difficult to reach the ground, give you more comfortable.

18/36
Special Control & Protection Function Instruction
1、 Hotel room card control Signal lines
(Red & Black)

Connect
Hotel room
card control

20/36
2、 Fire control
Signal lines
(White & Black)
Smoke sensor

Connect

21/36
4、Dual Core PCB Board

IDU PCB ODU PCB

 More precise control and Optimal control method, such as intelligent


defrost …

 More intelligent protect functions: current protection control,


sequence testing control…

23/36
5、Intelligent Defrost

Frost

Through detecting the time of defrost, adjust the


parameters next time intelligently,to ensure defrosting
time more accurate, and improve the defrosting efficiency.

24/36
6、ODU Quiet Operation

Through electronic control board to change setting, the ODU will


operate at mute mode,at this mode, the ODU will reduce the the
fan speed and operation frequency to get low noise. Mute mode will
give a low noise to the neighborhood environment(24~60K).

25/36
7、3 Fan speed of ODU

By changing the fan speed of ODU, to


adjust indoor cooling and heating
capacity output(24~60K).

Main control program will choose the most suitable ODU fan speed by detecting indoor and
outdoor temperature:
Cooling Mode: If the outdoor temperature is too low, refrigerant may not evaporate
completely and liquid refrigerant may entre the compressor and caused damage of compressor.
Hisense product will reduce the outdoor fan speed to reduce the heat transfer capacity to
avoid liquid strike at this situation.
Heating Mode: If the outdoor temperature is too high, the system will operate at high
pressure and compressor life will be shortened by long term running.. Hisense product will
reduced outdoor fan speed to reduce the heat transfer capacity, and make the system pressure
to get lower.

26/36
8、Safety Protection

A. Low/High pressure switch B. Discharge temperature sensor

More safe and reliable(36~60K) Ensure the compressor will


operation in the safety range, and
prevent the damage caused by
refrigerant leakage (24~60K).

Low pressure High pressure


switch switch

27/36
The other Features

1、Auto Restart

After power resuing, the unit will remember the original running
status (such as set mode, temperature setting, fan speed, louver
position)and restart automatically, to meet the needs of users.

28/36
2、Temperature Protection Functions

1. Fan motor overheating protection


2. Compressor start preheating
3. Compressor overheating protection

29/36
Cassette Type Introduction

30/36
Fashion Design

18k 24k/36k 48k/60k


650*650 950*950 950*950

Fashionable appearance & Compact structure & Flexible


installation : Perfect solution to match room decoration;
Flexible installation.

31/36
Low Noise Fan
New design of the vortex fan

18k 24k/36k/48k/60k

All modes use the vortex fan and optimized air tunnel,
low noise and smooth air flow.

32/36
PE foaming clad steel integration design

The Cassette type adopts “PE foaming clad steel integration design” ,
combined the high strength of steel and heat preservation & sound insulation
performance of the PE foam, make full use of foam’s toughness and steel’s
rigidity, improve the gel performance.

33/36
Temperature compensation of Cassette

For Cassette type heating mode, people always are not warm enough because
the hot air stay at the top level. Hisense Cassette bring 4 level temperature
compensation setting by DIP switch. The unit will increase the fan speed and air
circulation to create a comfortable environment for people.

34/36
Free Standing Introduction

35/36
Product Appearance

Hisense Integral panel design makes fashion style appearance and allow
CMF(Color\Material\Finishing) design extension and family appearance very well.
36/36
Product Feature
Purifying

•Hisense Patent Large Air Inlet(filter


area 1050cm2 for one side)
•Long Term & Easy Taken Filter
•Optional Healthy Module(eliminating
Formaldehyde and smell)

37/36
Product Feature

18K 24K 36K 48K 60K

indoor 1 1 1 1 1
Control Board
outdoor 0 1 1 1 1

indoor 3 3 4 4 4
Fan Speed
outdoor 1 3 3 3 3

For 24K/36K/48K/60K product ,we use two control board and outside three fan speed plan.
Advantage:
1、3 sensors in outdoor unit for accurate control(esp. defrosting and discharge protection).
2、3 speed fan motor for adjusting system pressure in the harsh environment.
3、HP switch and LP switch for keeping the system and compressor reliable.
4、Easy achievement the phase sequence protection and phase current protection.
5、With the communication between indoor and outdoor unit , any protection and error
could be detected in indoor unit.
38/36
Product Reliability
Outdoor unit High Reliability

Control Board
(Phase order protection) Accumulator
Ambient
Temperature
HP switch
Sensor

LP switch
Coil
Temperature
Sensor

Discharge
Temperature
Scroll comp.
Sensor

39/36
Product Appearance
Outdoor unit

60K
48K
36K
24K
18K

40/36
RTU ( Roof Top Packaged Units)

17 models Standard Efficiency- 4 ton to


59 tons
14 models High Efficiency 11.6 EER
R-22 and R-407C
50 Hz

41/36
Air Handling Units

13 basic model-19 extended


Eurovent Certification
Modular Design
Selection Software
Heat Recovery Systems

42/36
VRF System Introduction

43/36
44/36
45/36
46/36
47