A breakthrough in the history of calorimetry!
2 Year
warranty*
* 1+1 years after registering at
www.ika.com/register, glassware and
wearing parts excluded
2 3
C 1 Calorimeter | The Future starts here
4 5
C 6000 global standards | isoperibol
RFID technology used for decomposition 8804600 28400,- EUR Package 1/12 C 6000 isoperibol 4025000
vessel identification C 6012 4504000
KV 600 3410500
8804700 24600,- EUR Package 2/10 C 6000 isoperibol 4025000
Easy bomb preparation due to new C 6010 3770000
“turned around” crucible holder
8804800 26800,- EUR Package 2/12 C 6000 isoperibol 4025000
technology
C 6012 4504000
The C 6000 global standards offers a fast dynamic method, the classical The software for both calorimeters is handled through a LCD/TFT touch
adiabatic as well as isoperibol measurement modes. The C 6000 isoperi- The classical & traditional screen which provides many new features that make the daily operation
bol offers the same advantages and features, with the exception of the design with advanced easier and more comfortable. These units also possess a number of modern
adiabatic measurement mode. technology! interfaces which allow connection to networks, PC‘s, balances, keyboard,
mouse etc.
6 7
Calorimeters | Technical data
Available
Q1/2013
Available
Q1/2013
C1 C 6000 isoperibol | C 6000 global standards C1 C 6000 isoperibol | C 6000 global standards
Technical data Interfaces
Maximum energy input 40,000 J 40,000 J PC USB-B 9 pin (M) RS 232 serial
Resolution of temperature sensor PT 1000 0.0001 0.0001 Printer 9 pin (M) RS 232 serial USB-B
Powe ON-time continuous operation continuous operation Balance 9 pin (M) RS 232 serial 9 pin (M) RS 232 serial
Operating oxygen pressure 30 bar 30 bar Ethernet – yes
Display TFT TFT with touch screen SD-Card – yes
Multifunctional push & turn dial yes – Automatic oxygen filling / venting / flushing yes yes
Adiabatic (Only global standards) Automatic water filling / drain yes yes
Measuring modes Isoperibol (Regnault Pfaundler) Isoperibol (Regnault Pfaundler) Automatic ignition and ignition energy yes yes
Dynamic determination for each experiment
Start temperature settings 2 possible settings: 22 oC or 30 oC 3 possible settings: 22 oC, 25 oC, 30 oC Operated with KV 600
Operator time < 1 min < 1 min Water pressure from Chiller 0.3 bar 0.3 bar
Adiabatic (Only global standards) 4 Temperature setting: isoperibol 22 oC 20.5 oC –
Measurements per hour Isoperibol (Regnault Pfaundler) 5 Isoperibolic (Regnault Pfaundler) 3 Temperature setting: isoperibol 30 oC 28.5 oC –
Dynamic 7 Cooling medium tap water tap water or distilled with Aqua Pro C 5003.1
Jacket control static, dry controlled, water Operated with tap water and C 1.20 waterheater
Adiabatic (Only global standards) 0.05% Tap water temperature range 12 – 28 oC –
Reproducibility (using NIST benzoic acid 39j) Isoperibol (Regnault Pfaundler) 0.1% RSD Isoperibol (Regnault Pfaundler) 0.05% Water pressure max. 1 – 1.5 bar –
Dynamic 0.1% Water pressure min. – –
Number of decomposition vessel per unit up to 4 up to 4 Water consumption per experiment approx. 4 L –
Halogen resistant and catalytic activated vessels yes yes General Data
available ? Languages D, E, Fr, Sp, Chi, Rus, Pol, I D, E, Fr, Sp, Chi, Rus, Pol, I
Decomposition vessel ID manual automatic (RFID) Dimensions opened (W x D x H) 290 x 350 x 400 mm 500 x 450 x 620 mm
Dimensions closed (W x D x H) 290 x 350 x 270 mm 500 x 450 x 420 mm
Price 8900,- EUR | Price on request For prices, see page 6
Weight 15 kg 35 kg
C 1: Ident. No. 3825000 C 6000 isoperibol: Ident. No. 4025000 Ambient temperature 20 – 25 oC 20 – 25 oC
C 1 halogen resistant: Ident. No. 4505000 C 6000 global standards: Ident. No. 3780000 Ambient humidity 80% 80%
Voltage 100 – 240 V 200 – 240 V
Frequency 50/60 Hz 50/60 Hz
Power Input 150 W 2000 W
DC Voltage 24 V= –
8 9
C 1 and C 6000 | Common Accessories C 1 Calorimeter | Accessories
KV 600 digital
KV 600 digital is an active condenser with air-conditioned
Temperature range -20 – 40 °C refrigerator featuring a user-friendly microprocessor controller
Temperature setting digital with large temperature display. The temperature consistency
Temperature display digital is 1 K. The heat rejection rate and flow rate of the KV 600 are
Temperature sensor internal PT 100 customized to IKA® calorimeters C 1, C 6000, C 2000,
Resolution of display 0.1 K C 5000 control pack 2, and C 7000.
Temperature stability at -10 °C 1K
Refrigerating capacity at 15 °C 0.3 kW
at 0 °C 0.2 kW
at -10 °C 0.14 kW
at -20 °C 0.07 kW
Refrigerant R134a
Max. delivery capacity of pressure pump 12 l /min
Delivery pressure (head) max. 0.2 bar
Delivery suction pressure (head) max. 0.1 bar
Pump connection M 16 x 1
Pump connection for hose NW8/12
Bath volume 4l
Dimensions (W x D x H) 225 x 360 x 380 mm
Power supply requirement 208 – 240 V / 50/60 Hz
Power input 0.77 kW
Fuse 16 A Ident. No.
Min. ambient temperature 5 °C 3410500 230 V 50/60 Hz
Max. ambient temperature 32 °C 3410501 115 V 50/60 Hz
4502300 C 1.121 Set of spare parts Contains standard consumables, wearing parts for the C 1 calorimeter series and the
decomposition vessel C 1.12 for approximately 1000 experiments
10 11
C 6000 Calorimeter | Accessories Calorimeters | Consumables
C 5003.1 Aqua Pro Stabilizing agent C 710.4 Cotton thread, cut to length
Adjusts the conductivity of the water to achieve Qty. 500
optimal performance of the calorimeter. Prevents
growth of algae (Volume 40 ml)
4504400 C 6000.12 Set of spare parts Contains standard consumables, wearing parts of the calorimeters of C 6000 series and the decomposition Ident. No. Ident. No.
vessel C 6012 for approximately 1000 experiments 0749900 0750000
12 13
Calorimeters | Consumables Calorimeters | Software
C 723 Benzoic acid, blister package C 723 Benzoic acid, blister package,
large pack
Pelleted and blister packaged IKA standard
®
benzoic acid tablets with IKA® - certified Pelleted and blister packaged IKA® standard
gross calorific value for the calibration of the benzoic acid tablets with IKA® - certified gross
calorimeter (Qty. 50 pieces each 0.5 g) calorific value for the calibration of the
calorimeter (Qty. 450 pieces each 0.5 g)
to check the handling, decomposition procedure to check the handling, decomposition procedure The new IKA® calorimeter software Calwin C 6040
and the respective peripheral detection devices and the respective peripheral detection devices
follows in the footsteps of our Calwin C 5040 with
(Volume 50 ml) (Volume 50 ml)
Clearly arranged layout of a vast array of modern solutions, ideas and possi-
all measurements, results, bilities for managing the measurements from our
Ident. No. Ident. No.
and connected calorimeters
3044000 3080200 calorimeters. This software can be connected with
on one screen
the C 5000 (firmware 2.22), C 2000 (firmware 2.22),
C 200 as well as the new calorimeters C 6000 global
Printing and saving calibration
protocols with control chart standards, C 6000 isoperibol and C 1.
C 12 Combustion bags, small C 12A Combustion bags, large Ident. No. view
Polyethylene (PE) bags with already determined Polyethylene (PE) bags with already determined 4040500 Price on request
calorific value. For samples with a low calorific calorific value. For use with the following
Library and grouping
value, powdery and with low specific weight samples: low calorific value, powders and low
functions with extended
(Qty. 100, 40 x 35 mm) specific weight samples (Qty. 100, 70 x 35 mm)
data filtering options
Ident. No. Ident. No.
2201400 2201500
System requirements Correction calculations to obtain
G the net calorific value according
D
ISO to various ISO, ASTM, DIN, GB,
Windows XP (SP2), Windows Vista, Windows 7, GOST standards
C 15 Parafilm strips C 16 Parafilm
Microsoft SQL Server and at least one free USB or
For flammable or water containing samples 1000 x 500 mm RS 232 (9 pin Sub-D (M)) serial interface. Processor Data transfer to pre-configured
(Qty. 600) with min. 1.6 GHz (single core-Processor); 2 GB work sheets for Excel
Ident. No. Ident. No. RAM; 2.5 GB free hard-disc space; DVD-ROM-drive (configurable by the user)
3131100 3801100 Excel
14 15
Industries & Applications Calorimeter standards
> Biomass DIN 51900 – 2 Method using isoperibolic or static jacket calorimeter
> Construction and
Building Materials Wood Sample Analysis! DIN 51900 – 3 Method using adiabatic jacket
Wood pellets
Fleece Send us your sample and we will process and
Saw dust
Insulation material analyze it for you within 48 hours!
Grass
Styrofoam Corn Send your sample with a data sheet to:
Mortar Bio-fuels IKA®-Werke GmbH & Co. KG,
Rock wool Janke & Kunkel-Str. 10,
79219 Staufen, Germany.
16 17
Knowledge | History & Fundamentals Service | FAQ
When do I have to send the decomposition vessel to the high
pressure inspection at IKA®?
We recommend checking the vessel after 1000 experiments
or after 1 year of operation, whichever comes first. During
Calorimeter basics and brief history Adiabatic calorimeter Which calorimeter is most suitable for my application and the overall inspection process we perform both a high
requirements? pressure and an operating pressure test. A new certificate
A bomb calorimeter is used to measure the heat In an adiabatic calorimeter, the temperature in the outer vessel (Tov) is equal to the The main questions that should be answered are as follows: will be issued for the vessel after it has passed both of
created by a sample burned under an oxygen rich temperature of the inner vessel (Tiv) throughout the experiment. This is as close to 1. How many experiments do you plan on conducting in these tests. More detailed information can be found in
atmosphere in a closed vessel, which is surrounded a “perfect isolation” as possible. The influence of the environment has to be mini- a day? the manual of your calorimeter and/or the manual of
by water, under controlled conditions. The mea- mized using air-conditioning to keep the room temperature as constant as possible. 2. Are there any standards that have to be followed, such your decomposition vessel. Alternatively, you can always
surement result is called the combustion, calorific No correction calculations need to be done when compared with the isoperibolic
as ISO, ASTM, DIN, GB, GOST etc.? contact our service department for further information and
or BTU-value. The result allows one to make certain calorimater.
3. Do samples contain halogens and sulphur and in assistance.
decisions regarding the quality, physiological, physical T [K]
which concentration approximately?
and chemical, as well as financial conclusions about Tov
Te 4. Is it required to analyze the halogens and sulphur content Where do I find a list of spare parts and how many of these
the product. Tiv
after the calorimeter experiment has concluded? do I need?
The term “calorimeter“ was first mentioned by 5. Do you prefer any of the following methods: adiabatic, We offer sets of spare parts that include parts for 1000
Josef Black in 1770. One of the first calorimeters isoperibol, static jacket isoperibol, dry or dynamic? experiments e.g. 1 year operation. The actual amount of
(ice-calorimeter / phase transition calorimeter) was spare parts can vary based on the application. If a specific
developed by Lavoisier and Laplace around 1780. Ts How do I know my calorimeter is still in calibration? spare part is required, you can find further information in
The calorimetric bomb is also called “Berthelotsche Most customers operate their calorimeters with control the service section of the instruction manual. In addition,
Bomb“. Marcellin Berthelot developed the combu- Tov = constant
Tiv Prel. experiment Main experiment Post experiment t [min]
2 - 6 min. 8 - 12 min. Approx. 6 min. charts. After calibrating the unit, check runs are performed on our website (www.ika.com) in the service section you
stion of samples in a closed pressure resisting vessel with benzoic acid, for instance. The results of these check can download service drawings with detailed descriptions of
c x ΔT - Qf T iv
into a standard method. He was the first to use pure Ho adiab. =
m T ov runs have to match the certified calorific value of the each part. Alternatively, you can always contact our service
oxygen at higher pressures to get a faster and more ΔT = Te - Ts
benzoic acid within a defined range. The definition of the department for further information and assistance.
complete combustion (1885). In 1892, the first
range is laid out in standards and the frequency of doing
patent for a calorimeter to measure the heating
value of gaseous fuel was given to Hugo Junkers, Isoperibol calorimeter these checks differs from 1 to 2 a day, to 1 after and before How can I get the gross and net calorific value - easily
a German inventor and aircraft engineer. IKA® every sample. The control charts show the performance of explained?
introduced their first bomb calorimeter in the 1920‘s. In an isoperibol calorimeter the temperature in the outer vessel (Tov), is kept con- the unit under the previously described circumstance over A calorimeter measures the preliminary gross calorific value
Since then our calorimeters have been continuously stant throughout the experiment. This does not allow a “perfect isolation”. There a long period of time. of the sample. To get the gross calorific value, correction
developed according to the latest standards and are still small temperature fluctuations. The influence of the environment has to be calculations are required for the acids formed during the
technologies. minimized by using air-conditioning to keep the room temperature as constant as How often do I have to calibrate the calorimeter? combustion. For instance, the method of titration used to
possible. A correction factor (Regnault-Pfaundler = ξ) will be calculated after the The control chart also shows when a new calibration might obtain the amount of nitric acid and sulphuric acid are
There are many different types of calorimeters experiment that takes these temperature fluctuations into account.
be required. described in detail in the standard ISO 1928. To get to the
available on the market: Solution, DSC - Differential net calorific value, further corrections need to be applied
Scanning, Titration, Gas and Reaction Calorimeters.
ts + te
ze - ∆z
ts – te ts – te Which is the max and min calorific value that I can measure concerning the amount of water that was formed during
ξ=θ ∆z
2
+ ∑t – (z e + za ( 2
– (z
e – za ( zs – ze with the calorimeter? the combustion from hydrogen. Based on in the state (dry,
IKA manufactures so called bomb - or combustion
® za - ∆z
calorimeters. The max. allowed energy input into our calorimeters is analytical moisture, as received…) your sample was in
term 1 term 2 term 3
40,000 J. The calorific value of a sample is always expressed before combustion, further corrections may apply. Moistures
T [K]
About 1 g of solid or liquid matter is weighed into a Tov
in energy per weight (J/g). Based on that information, you are determined by drying the samples. The Hydrogen
crucible and placed inside a stainless steel container. Tiv
Te
f1 can adjust the weight of your sample such that it does not content is usually measured with an elemental analyzer. For
T tan
The decomposition vessel or bomb is filled with f2 exceed 40,000 J. The energy amount created by the sample a more detailed explanation, we ask you study the standards
30 bar of oxygen (quality 3.5: technical oxygen f1=f2 should not be significantly higher than the one obtained you might have to use depending on your application
99.95 %). The sample is ignited for example through during calibration with benzoic acid. Our calorimeters requirements.
a cotton thread connected to a solid ignition wire do have a high measuring sensitivity and can detect low
inside the decomposition vessel and burned. During quantities of energy. For example, the ignition energy of
the combustion the core temperature in the crucible Ts
To 70 J can be measured with an absolute error of +/- 20 J.
can reach 1000 °C, and the pressure rises as well. All Tov = constant
Prel. experiment Main experiment Post experiment t [min]
2 - 6 min. 8 - 12 min. Approx. 6 min.
The relative error rises naturally (+/- 30%) hyperbolically the
organic matter is burned and oxidized under these
conditions. c (dT + ξ) - Qf T iv
smaller the energy input is. If your sample has a very low Application Support!
Ho isop. =
m T ov calorific value you can also use combustion aids, since they
The heat created during the burning process can be add energy to the calorimeter to minimize the error. For questions regarding applications and
determined using the isoperibol, adiabatic or dyna- Dynamic calorimeter processes, you can call our hotline number:
mic measurement procedure. 00 8000 4522777 (00 8000 IKAAPPS)*
The dynamic IKA® designed modes are basically short versions of the original E-Mail: applicationsupport@ika.de
adiabatic and/or isoperibolic measuring modes. The measurement results still
conform to the required Relative Standard Deviation (RSD) of the official standards. * Monday – Thursday from 8:30 - 16:30
Friday from 8:30 - 15:30