You are on page 1of 3

System Advisor Model Report

Detailed Photovoltaic 6.12 kW Nameplate 32.61, -115.46


Residential $2.51/W Installed Cost UTC -8
Performance Model Financial Model
Modules Project Costs
SunPower SPR-X22-360-E-AC Total installed cost $15,366
Cell material Mono-c-Si Salvage value $0
Module area 1.63 m² Analysis Parameters
Module capacity 359.96 DC Watts Project life 25 years
Quantity 17 Inflation rate 2.5%
Total capacity 6.12 DC kW Real discount rate 6.4%
Total area 27 m²
Project Debt Parameters (Mortgage)
Inverters Debt fraction 100%
SMA America: SB6000TL-US Amount $15,366
Unit capacity 6 AC kW Term 25 years
Input voltage 100 - 480 VDC DC V Rate 5%
Quantity 1
Total capacity 6 AC kW Tax and Insurance Rates
DC to AC Capacity Ratio 1.02 Federal income tax 15 %/year
AC losses (%) 1.00 State income tax 7 %/year
Sales tax (% of indirect cost basis) 5%
Two subarrays: 1 2 Insurance (% of installed cost) 0.5 %/year
Strings 2 1 Property tax (% of assessed val.) 0 %/year
Modules per string 6 5
String Voc (DC V) 417.00 347.50 Incentives
Tilt (deg from horizontal) 32.00 32.00 Federal ITC 26%
Azimuth (deg E of N) 180 180 Electricity Demand and Rate Summary
Tracking no no Annual peak demand 4.3 kW
Backtracking - - Annual total demand 10,829 kWh
Self shading no no Generic Residential
Rotation limit (deg) - - Fixed charge: $10/month
Shading no no Monthly excess with kWh rollover
Snow no no Tiered TOU energy rates: 4 periods, 1 tier
Soiling yes yes Results
DC losses (%) 4.44 4.44 Nominal LCOE 7.9 cents/kWh
Performance Adjustments Net present value $3,100
Availability/Curtailment none Payback period 13.1 years
Degradation none
Hourly or custom losses none
Annual Results (in Year 1)
GHI kWh/m²/day 5.95 5.95
POA kWh/m²/day 6.00 6.00
Net to inverter 11,340 DC kWh
Net to grid 11,030 AC kWh
Capacity factor 20.6
Performance ratio 0.73

System Advisor Model Standard Report generated by SAM 2020.2.29 on Mon Mar 30 16:50:02 2020 1/3
Detailed Photovoltaic 6.12 kW Nameplate 32.61, -115.46
Residential $2.51/W Installed Cost UTC -8
Year 1 Monthly Generation and Load Summary
Electricity from System
Thousand kWh 1

0.5

0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Load
Thousand kWh

1.5

0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Year 1 Monthly Electric Bill and Savings ($)
Month Without System With System Savings
Jan 96 46 50
Feb 83 27 56
Mar 83 21 62
Apr 84 24 60
May 116 37 78
Jun 167 62 105
Jul 229 90 138
Aug 201 78 123
Sep 144 52 92
Oct 127 53 73
Nov 84 33 51
Dec 93 34 59
Annual 1,513 561 951

NPV Approximation using Annuities


Annuities, Capital Recovery Factor (CRF) = 0.1023 Investment = Installed Cost - Debt Principal - IBI - CBI
Investment $0 Sum: Expenses = Operating Costs + Debt Payments
Expenses $-1,300 $300 Savings = Tax Deductions + PBI
Savings $400 NPV = Sum / CRF: Energy value = Tax Adjusted Net Savings
Energy value $1,100 $3,000 Nominal discount rate = 9.06%
Payback Cash Flow (Payback Period = 13.1 years)
10
Thousand $

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

-10

Year

System Advisor Model Standard Report generated by SAM 2020.2.29 on Mon Mar 30 16:50:02 2020 2/3
Detailed Photovoltaic 6.12 kW Nameplate 32.61, -115.46
Residential $2.51/W Installed Cost UTC -8
Nominal POA (kWh)
68,847
Shading
-0 %

Soiling
-5 %

Reflection (IAM)
-2.669 %

Bifacial
-0 %

Nominal DC energy (kWh)


14,058
Snow
-0 %

Module
-15.579 %

Inverter MPPT clipping


-0 %

Module mismatch
-2 %

Diodes and connections


-0.5 %

DC wiring
-2 %

Tracking error
-0 %

Nameplate
-0 %

DC power optimizer
-0 %

DC availability and curtailment


-0 %

DC Lifetime daily losses- year one


-0 %

Net DC energy (kWh)


11,341
Inverter power clipping
-0 %

Inverter power consumption


-0.323 %

Inverter nighttime consumption


-0.07 %

Inverter efficiency
-1.331 %

Gross AC energy (kWh)


11,146
AC wiring
-1 %

AC Lifetime daily losses- year one


-0 %

Transformer loss
-0 %

AC Availability and curtailment


-0 %

Annual energy (kWh)


11,034

Residential | Flat Plate PV | Simple Efficiency Module Model | Sandia Inverter Database
System Advisor Model Standard Report generated by SAM 2020.2.29 on Mon Mar 30 16:50:02 2020 3/3

You might also like