IMPORTANT: READ THIS MANUAL CAREFULLY. IT CONTAINS INFORMATION
‘BOUT SAFETY AND THE SAFETY OF OTHERS. ALSO BECOME FAMILIAR WITH
‘THE PROPER INSTALLATION AND CONTROLS OF THE AIR DRYER BEFORE
OPERATING.oO
A. INTRODUCTION
‘Thank you for selecting an DRYMAX HX series refrigerated air dryer from
MACAIR INC.
“The refrigerated air dryer is specifically designed and manufactured for
drying and purifying compressed alr generated by an alr compressor. Please
read this instruction manual carefully before using the air dryer.
Please pay attention to the precautions in transportation, installation and
operation that are listed in this manual.
Please use the dryer according to our application guide and be sure to
perform the proper preventative maintenance as recommended in this
manual, Failure to perform the preventative maintenance will void the alr
dryer warranty.
Refrigeration used in this alr dryer is environmentally friendly R134 or
Ra04a_and is available at local refrigeration wholesalers.
Direct any questions not covered in this manual to your distributor or call
MACAIR INC. @ 248-624-6300. Before calling with questions always have the
air dryer model #, serial # and pressure gauge readings.
Service and maintenance can be obtained from your distributor. If you do not
know your distributor please contact the factory.
Authorization # must be obtained from MACAIR INC. before any parts or
dryers are returned to the factory. MACAIR INC. will not be responsible for
anything returned without authorization.
Contents Page Contents Page
Precautions... 3 What your gauge should
read. 7
Installation. a)
Normal Maintenance. 7
Data Label. 4
Auto-Drain Maintenance. 7
Dryer Controls. ene
Trouble Shooting Guide. 2
Start Up, : 5
Electrical
Initial Run Schematics. 10
Procedure. 6
Installation
guide, sno
Warranty, 42.
)
PRE-CAUTIONS
‘The dryer cannot be tited on its side or upside down during shipping.
Use forklift from the bottom of the dryer when installing or moving
‘The dryer must be grounded properly to prevent electrical shock.
‘Turn off the compressed alr supply and depressurize the dryer and
disconnect the electricity before inspecting the dryer.
5, Do not modify or change the electrical control system and do not,
connect other appliances into the control system.
6. Do not tum the dryer on and off frequently. After the dryer is shut off
wait 10 minutes before you restart the dryer. The dryer’s evaporator
pressure and the condensing pressure must equalize before the dryer
is restarted.
7. Check the compressed alr pressure and flow and the electrical ratings
to be sure they are correct and within the dryers operating
parameters
INSTALLATION
4. Ventilation ~ Install dryer only in a well-ventilated clean, dry area only
and keep at least 3 feet between the dryer, other equipment and the walls.
2, Dryer Location - Do not install the dryer outside. The air dryer must not
bbe exposed to direct sunlight, rain or snow. Do not install the ¢ryer in an
environment with fire, high temperatures or iow temperatures.
Make sure the dryer Is installed in an environment that is clean anc dry. Dust
‘and dirt particles will clog the air-cooled condenser. A clogged and dirty
condenser will reduce the performance of the dryer and will eventually cause
damage to the dryer.
3, Ambient Temperatures ~ Suitable ambient temperature for the
refrigerant dryer is a minimum of 35 F to a maximum of 110 F. The
performance of the dryer will be significantly decreased when the air dryer is
Subject to temperatures higher than 110 F. For installations with ambient
temperatures higher than 110 F It is recommendes to use @ water-cooled
condenser on the dryer. Contact your dealer for details.
4, Selecting Proper In and Out Piping and Piping Design - Pipe
L sypass vawves
a sores