3.

Main Software Install Process

COM 1

PC

RS-232
2 2 0 V A C
S
M
P
S
Main PCB
D S R 9 5 0 0A

Fig. 3-1

ΠPrepare PC and DSR9500A as above Figure.


´ Open DSR.TRM file while executing HYPERTERMINAL of PC.
Port : Select to COM 1 port currently used.
Baudrate : 115200
ˇ As Vol-up key of Front PCB presses, POWER(PLUG) ON.
◆ SRF-00903A : Samsung Brand FTA Model
Loader version x. x
◆ SRF-02903A : Samsung Brand CI Model
Loader version x. x
◆ SRV-20903A : Samsung Brand EM VIACCESS Model
Loader version x. x
◆ SRV-22903A : Samsung Brand CI+VIACCESS Model
Loader version x. x
¨ Send a file at Download ROM image. ( PROTOCOL : 1K XMODEM )
ˆ Select Main Program (C:\main\DSR9500A_FINAL.bin) by each kinds as selecting the File Send of
Transfer or Hyperterminal.
Ø Check if the normal message appears.