You are on page 1of 2

3/28/2020 ETP

Select Language:

HOME CORPORATE PROFILE CORPORATE POLICIES PRODUCTS OPERATIONS EVENTS AND ACTIVITIES CAREER DOWNLOADS CONTACT

Content on this page requires a newer version of Adobe Flash Player.

Effluent Treatment Plant (ETP)


Menu Events and Activities
CSR 2020
Corporate Profile
CSR 2020
04 March 2020
Corporate Policies

Products
Heimtextile January 2020
Operations Heimtextile Frankfurt Germany
Hall No. 10.3, Stand B-45 - 7th-
10th January...
Health Centre 15 November 2019

ETP World Quality Day 2019


World Quality Day 2019
Events And Activities Management of International
Textile Limited ...
14 November 2019
Downloads
Adult Literacy Program
Training Calendar Adult Literacy Program November
2019 International Textile
Career Limited...
12 November 2019
Contact

Web Mail

Contributing towards Green Environment

Our ETP plant has been designed to treat the effluent having BOD (Biological Oxygen Demand)
above 900 mg/liter which has to reduced to NEQ’S (National Environmental Quality Standards) equal
to 80 mg/liter and the COD (Chemical Oxygen Demand) to about 150 mg/liter. The effluent after
pH adjustment with Sulphuric acid goes to cooling tower to reduce the temperature from 70 degree.C
to 36 to 37 degree.C. then it comes to equalization tank to homogenize the effluent.

Afterwards it goes to Aeration Tank where complete process of aeration is installed and Urea and DAP
(Di ammonium phosphate) is being used for the bacterial colony to activate the sludge reducing the
BOD and COD, after about 30 hours retention time in aeration tank the over flow goes to clarifier tank
where the sludge has been settled into the bottom of clarifier tank. The sludge we used to recycle 50%
to back to aeration tank and the remaining 50% goes to filter press to dewatering and to make the
cake for proper disposal purposes.

Main Components of our ETP Plant

Aeration Tank.

Clarifier Tank.

www.internationaltextile.com/index.php/effluent-treatment-plan 1/2
3/28/2020 ETP
Equalization Tank.

Sludge Tank.

Cooling Tower.

Air Blowers.

Chemical Dosage Pumps.

Plant Treat Capacity (ETP)


1200 Cubic meter per day. i.e.: 50Cubic meter per hour.

Waste Water Analytical report by SGS


Dated: 28-Feb-2014

Download Test Report PDF

Waste Water Test Report by SGS


Download Test Report PDF

Chemical Analysis Test Report by GEL PVT. LTD


Download Test Report PDF