Servo control 85 with foot pedal to contro! hydraulic hammer 300
and cylinder / stone crusher 305
(located on the left hand side on the cab floor)
Added control valve block 116 with integrated contro! spool 117
and primary pressure relief valve 122, 135 and secondary
pressure relief valve 136.
Switch 93 ( 833 ), installed in servo line of installation kit AHS 5
on connection a1 of control valve block 116.
‘See section 16.50 “Flow Reduction”
Senennung/Description/Dénaminaion yp "gpage 16
LIEBHERR Medel rou
‘Abvtromia partir de
Hydr. Installation Ki
AHS5
DatumieditionDate
07.93 BlatuPagerreuillo
16.44.0420
30
40
a
50
56
70
n
R
B
76
81
85,
90
92
Hydraulic tank
Var. displacement double pump
Gear pump /Servo control
Test point /Pump P2
Test point/Pump P1
Servo oil unit
Solenoid valve / Servo control (Y3*)
Distributor block
Two way check valve
Two way check valve
‘Two way check valve
Two way check valve ( only on R 900-922)
from right servo control 4-way
Servo control / 2- way with foot pedals
Switch / Servo control ( B30* )
‘Switch/ Travel (B32* )
* Positions in electr. schematic in section 8.
Different location
when electronic switch 93 ( B33 ) is installed
93. Switch/ flow reduction/ Hydr. Installation Kit
(833*)
94 Switch /Servo control (B22* - only on R932
and R942)
100 Compact control valve block / 7- way
115 Distributor valve
116 Added control valve block / 1-way
117 Spool / Hammer 300 and cylinder 305,
120 Primary pressure relief valve / Pump P2
121 Primary pressure relief valve
122 Primary pressure relief valve / Pump P1
135. Primary pressure relief valve / hammer
operation and retract cylinder
136 Secondary pressure relief valve - extend cylinder
305
300 Hydraulic hammer
305 Hydraulic cylinder / Rock crusher
320 Shutoff valve
For schematic for R 932 and R 942,
see reverse page 16.44.05R900-R922
jenennuns 1/Description/Dénomination
LIEBHERR
Hydr. Installation Kit
AHS5
‘Abstrom/ partirde
DatumveditionDate
BlatuPagerFeuille,
07.93
16.44.05R932-R 9421. Use
In order to operate an additional hydraulic installation,
such as an hydraulic hammer at full load / at max. engine
RPM, but with reduced pump flow (since these hydraulic
installations require less oil), it is necessary to install and
adjust components which reduce pump flow in Litronic
machines.
2. Principle
When the appropriate installation is actuated via switch
B33, an electrical signal is forwarded via the electronic
control to circuit board 4 (fig. 1).
A limit signal corresponding to the adjustment of the two
potentiometers P1 and P2, which are integrated in the
Circuit board, is forwarded to the electronic horsepower
control
For description, see sub group 8.71
This causes the pumps to return to a certain selected pump
angle (flow)
Location of switch B33
= On R912
in the control line of the installation kit, on distributor
block 70.
+ OnR 902, R932 and R942
in the control line of the installation kit, on the control
pressure connection of the added control valve block 116
Benennung/Description’Dénomination
LIEBHERR
Datum/Edition/Date
04.91
‘otrol reso
95}
Special Installation
Flow Reduction
yp See pa
20 page 16
Model
‘Sub Group Index
Type °
‘Abitrom/a partir ae
16.50.01Versions of circuit board Ad for flow reduction
+ Version 1, installed up to Dec. 1990
In this version, potentiometers R15 / R16 for pump angle limitation of pumps P1 / P2 are adjustable multi
position switches, see fig. 4
Version 2, installed from January 1991
‘The potentiometers R15 / R16 for pumps P1 / P2_ are rotating potentiometers, which are adjustable to
any desired intermediate value, see fig. 5.
3. Adjustment
3.1. Adjustment of reduced pump flow with circuit board Ad “Version 1"
Reduced pump flow is adjusted by turning adjustment washer 1 on potentiometer P1 or P2, until
the slot of the washer is straight above the preselected notch.
Example
‘An R912 Litronic machine is to be supplied with max. flow of 140 I/min by pump P1.
‘The max. flow without reduction on this machine is 200 l/min per pump.
The necessary reduction of 30% is obtained when the adjustment washer of the potentiometer for
pump P1 (marked ” P1 “on plate) movesinto notch 5 ( equals 68% of max. flow, or 136 l/min)
oO
bhitithre
12345678
ship!
1650013.2 Test and
board Aa
3.24
3.22
LIEBHERR
Datumeaition/Date
04.91
jjustment of reduced pump flow with circuit
fersion 2"
Adjustment Guidelines
The potentiometer R15/R16 may only be checked
and adjusted if the electrical current (mA) is checked
at the same time.
Connect test fitting (Tool No. 33/ Id.-No. 6001232)
or test box with adapter cable (Tool No. 30-32 Id.-
No. 6002698 and 9357555 / 9357556 ) in connection
with a multimeter to check the amperage to regula-
ting solenoids Y4/Y5 of pump P1/P2, see fig. 6 or 7.
Adjust the potentiometer only when the Diese!
engine is running at max. RPM.
At the same time actuate the corresponding pilot
control valve
To adjust potentiometer R 15/R 16
see fig. 4,5,6and 7
Connect test adaptor or test box with multimeter,
see fig. 60r7.
Determine the adjustable amperage of the
regulating solenoid via the required flow quantity (
Qred. in min) from diagram 8,
Run the Diesel engine at max. RPM.
‘Actuate the corresponding pilot control valve for
the added installation and measure the electrical
current
Turn potentiometer R 15 or R 16, see fig. 5, until the
correct amperage (mA ) shows on the multimeter.
Note:
Potentiometers R15 / R16 are adjustable over the
total range from 250 to 750 mA, which means the
pumps can be adjusted to any value between Qmax
and Qmin.
enennung/Description/Dénomination
Flow Reduction
eo:
Oa
" Hom "Ig
(ey'> I)
2 Oe
5
re gun
Gacy ||
K TEAS Biba
Hee dah
To check current with test adapter
Test box Horsepower control
No. 6202698 pow
‘Adapter cable
ta-No: 9357556,
. Adapter cable
do. 9357355]
Cable to circuit hoard At
To check current with test box 7
Typ See page 16
Model “Sub group
Index
Type
‘Abyfromia partic de
BlatuPagerreuile
16.50.02Turn to the right to reduce oil flow with smaller amperage.
Turn to the left to reduce oil flow with larger amperage.
After correct adjustment of pump flow for this special installation, remove the test box or adapter cable
and reestablish electrical connections as before.
3.2.3 Example, see diagram 8:
A hydraulic hammer installed on a R 912 Litronic is supplied by pump P1 with maximum flow of
140 l/min
‘According to the diagram, the amperage on the regulating solenoid Y4 of pump Pt is 600 mA.
Current Value’
Amperage
(may Diagram 8
7 (pvo64 tPvd75: |: LPvD 100 | LPVD 125: Pvp 140:
750 *
7 =F
4 fed
4 \
* 1
600 — ce
‘ {
500
‘ '
+ 1
4 1
4 Lol
: { '
+ poche
¥ t 1
en)
1 '
i 1
peceeeed Quantity @
costco, eat
° sominal a
° L
i
Pump flow mini Pump flow maxi
‘at pump angle min, ‘atpumpangle max.
1650.024. Retrofit of "Flow reduction” installation
Connect switch B33 with hose 5 and fitting 6 between distributor block 70 or added control valve block 116
(on R932 and R 942 and pressure hose 79 of the installation kit.
Install circuit board A4 to bracket 1 and screw complete panel into box 26
On R 932 and R 942, which are fitted with A13 circuit board (circuit board for special installations), bracket 1 is
not required. In this case, circuit board Ad is installed directly on circuit board A13 with spacers.
Connect connector cable 2 between circuit board A4 (Plug X70) and circuit board At (plugs X13 and X12)
Connect cable 3:
~ Short part 3.1 with 2 pole Sure-Seal plug to switch B 33.
~ Long part 3.2 with 2 pole Sure-Seal plug to reserve plug 27 of main cable kit - engine 28 (besides main
fuses in battery box)
~ Wire with cable shoe 3.3 to ground screw on swing platform
Connect the 3 pole plug X72 of the main cable kit - engine (in box 26) into plug X72 on circuit board Ad
R902-R912
R902, 932- R942
yp See page 16
Mode! “subgfoup index"
Type
Benennung/Description/Dénomination
LIEBHERR
Flow Reduction
‘Abitrom partir de
DatumfEditionDate
BlatvPaaerreuille
16.50.03
09.911 =
Sern 15"
xp ean
(isa)
Al
2 Cable/ Circuit board At - Circuit board Ad F3 Fuse 15A
3 Cable for switch 833 R1__Potentiometer / Pump angle reduction
27 Sure -Seal Plug am main cable kit - engine (optional installation)
Al Circuit board X12 Plug A1/2 pole
X13 Plug A1/9 pole
X70 Plug A4/9 pole
Aa Circuit board / Flow reduction
13 Circuit board / Added installation
(only on R932 - R942) X71 PlugA4/9 pole
833 Switch/ Flow reduction X72 Plug A4/3 pole
165003use
In order to operate an additional hydraulic installation, such as an
hydraulic hammer at full load, max. engine RPM, with reduced
pump flow (less oll requirement), the installation and adjustment
‘of components to reduce pump flow in Litronic machines is
necessary.
When the appropriate installation is actuated via an integrated
switch, an electrical signal is forwarded via the electronic control to
print plate AZ
Two potentiometers R 15 / R16, integrated in print plate A2,
reduce electrical current to the regulating solenoids ¥4/ Y5 for
pumps P1/ P2 to the adjusted value.
This causes the pumps to work at a certain pump angle (flow),
which is in proportion to the regulating current
Description of flow reduction installation, see fig. 1-3
1. The standard print plate A2 - installed in the instrument panel
to the left next the operator's seat above print plate Al -
contains both adjustable potentiometers R 15 and R 16.
For diagram and description of print plate A2, see electrical
system, section 8.40.
2. To reduce pump flow, electrical current to regulating solenoids
Y4 and Y5 on variable displacement double pump is reduced to
acertain value by adjusting potentiometers R15/ R16
For construction and function of regulating solenoids and
pump adjustment, see variable displacement double pump,
section 7.10,
3. Switch 93 ( B33 ) is installed in servo control line of the
appropriate installation
Every time the added installation is actuated, a signal is
forwarded to the electronic horsepower control. In this
electronic control, the signal is processed and potentiometer
RIS/ R16 actuated
Note:
‘Switch shown in fig. 3 is installed in front of the added control
valve block 116 in servoline b1
Benennung/Descripton/Dénomination
LIEBHERR
Flow Reduction
in A - Model Machines
Datumedionibate
05.90
Typ seePage 16
Model “Sud Group index
Type
‘Abitrom/a partirde
BlatuPage Feuile
16.51.01Regulating solenoid
Pump
Plug blue
=
fa
id'No. 6001232
\
\
cable AX s.r
{oregulating soleng tee tage
wa 4
|
wa.
To check voltage with Test adapter
Testbox
td-No: 6202698
Horsepower control
‘Adapter cable
{dno 9357556
(er cable
fo.9357555|
Cable to Print plate At
5 | Tocheck voltage with Test box
To check and adjust reduced pump flow
1. Adjustment Guidelines
1.1. The potentiometer RIS/R16 may only be checked and
adjusted if the electrical current (mA is checked at
the same time.
Connect test fitting (Tool No. 33, Id.-No. 6001232) or
test box with adapter cable (Tool No. 30 - 32, Id.-No.
{6002698 and 9357555/ 9357556) in connection with a
multimeter to check the current between the electr.
connection of the regulator solenoids ¥4/ Y5 of pump
P1P2, see fig. 4 or 5.
1.2. Adjust the potentiometer only when the Diesel
engine is running at max. RPM.
At the same time actuate the appropriate servo
control valve.
1.3 Switch 93 ( 833 ) must be functioning properly , this is
a prerequisite for proper function of the adjusted
flow (Qred.)
2. Toadjust potentiometer R15/R 16, see fig. 4,5, 6 and 7
2.1. Connect test fitting or test box with multimeter, see
paragraph 1.3 and fig. 4orS.
22 The adjusted electrical current of the regulator
solenoid is determined by the necessary flow ( Q red,
in min ) from the diagram (comparison chart) on
reverse page, see example, fig. 7.
2.3. Bring Diesel engine to max. RPM.
Actuate the appropriate servo control for the added
installation and check the electrical current,
2.4 Turn potentiometer R 15 or R 16 with a screw driver,
see fig. 6, until the determined value (mA) shows on
the multimeter.
Note:
The adjustment range of the potentiometer R 15/R 16
equals a current of 750 - 530 mA, which results in a
hydraulic flow from pump P1 /P2 of 200-112 limin.Turn clockwise = to reduce current
Turn counterclockwise = toincrease current ia
25. After correct adjustment of pump flow for the additional |.
hydraulic installation remove test box and/or adapter
cable and reconnect electrical connections.
Example, see fig. 7:
The manufacturer of the added hydraulic installation, as |
the hydraulic hammer, specifies a max. pump flow of 170!
Fein’
Using the chart, this results in a current on the regulator
solenoid Y4/Y5 of pump PI /P2 of 670 mA,
|
Current Comparison Chart
Current - Pump Flow
to -
1 750 ‘
BEAIREEEPA SO PF hes eae peed das
! ae Fondo :
—— 530
fT a Peper poy :
tapers ob | ;
25 112140 160 180 200 gpimpps
(in ymin)
Intermediate value for installation (in l/min)
Senennung/Desrption/Dénomiation Typ SeePoge ve
LIEBHERR Mooel Sub grove
Flow Reduction ‘Abtromia part de
Datum iEaition/Date
BlatuPagerFeuille
0290 16.51.02Connection of Switch 93 ( B 33)
on Print plate A2
Print plate A2
83
oF
138
TDooo
=] SS Ge 2
Eee) x95) x7
a8 135 an
Oo Bt x60 Yaa] ES) sy]
=] fn
xe3 | 33 K56 Tr pe) xa[o<
336
«
7 K62
730
B33
See also electrical system (schematic A2) in section 8.40