tk Maximum Demand Meter Data choot No: MOWION DESCRIPTION ‘Maximum Demand meter is used for monitoring thermal loading in Power Distribution systems, Networks, [Machines ote indicates maximum loading curent over a period. Short-perod current peaks aro no rogistored but long averioads are registro, Inthe Maximum Demand meter the measuring currant flows through the bimetal spiral whichis temperature ‘anata Tha frae ant ofthe furl ie sonnets tn lark massing peintar Tha moving system fe actatod by heat generated by the current flowing through the spiral. The insttument fs provided with an addtional red save poner wih 2 higher cian, which makes to remain ais maximum pasion, which determenes the ‘maximum average leading curen. The high torque of metalic movement drags the fed pointer along withthe black porter. The red pointer remains stationary atthe maximum value reached. This can be reset by rotating the knob provided on font facia. To prevent fase indication due fo fluctuations in ambiont tomparature, an _éitonalbimetalic spiralis wound in opposite ciroction, which Is mounted on the same spinle Io compensate ‘aration in temperature from 10 to +55 degroes Centigrade Frequently there's 2 need to measure Instantaneous Curent simultaneously & hence moving fron movement hhaving the same range Is incorporated in te same meter. FEATURES 4+ RMS measurement of maximum current Long current peaks ar registered (Red pointer to indeste mayimum curent reached 4 Analogue lncation, + 20% overioed cepacty. ‘Instantaneous current measurement (3 Pointer) Sturdy movement ELECTRICAL SPECIFICATIONS * TPE @) BIMETALLIC. b) BIMETALLIC & ANALOGUE ANMETER, OPERATING CURRENT ‘Amo or 5Amo | FREQUENCY 40~ 65H + ACCURACY + 394 for roctiable red poinior (Bimota). +.5% inslanlaneous value porter (Meng Iron) + THERMALLAG [SETTING TIME): 15 minutes (standard) & 8 minutos (on specal request) *VABURDEN ‘Approx. 3.5VA for Bimealic Ammneters & ‘Approx. 4VA for Bimetalic And Moving kon Ammer + INSULATION RESISTANCE {Greater than 20M ohms at S0OV DC + DIELECTRIC TEST 2kV rms for 1 minuto, + OPERATING TEMP. “10°C to 55°C (for Analogue Instrument) 4 STORAGE TEMP, 2rCt0 706 © HUMIDITY Upto 95% RH Pointer Deflection / Time 89 g 8 fas BI ‘min. Thermal lag = | a5 45min. Thermal lag le 2 | 15 Blo, ee “Time in minute Maximum Demand Meter m MECHANICAL SPECIFICATIONS * PRESENTLY UNDER PROCESS. Ordering information 1) Tye 2)Model__—_ 3) Operating Curent 4)CTR. 5) Thormallag Soting Time

You might also like